Hatco FS2HAC-4PT Part Manual

®
FLAV-R-SAVOR
Heated Air Curtain Cabinets
FS2HAC Series
Installation and Operating Manual
I&W #07.05.205.00
Do not operate this equipment unless you have read and understood the contents of this manual! Failure to follow the instructions contained in this manual may result in serious injury or death. This manual contains important safety information concerning the maintenance, use, and operation of this product. If you’re unable to understand the contents of this manual, please bring it to the attention of your supervisor. Keep this manual in a safe location for future reference.
No opere este equipo al menos que haya leído ycomprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte. Este manual contiene importante información sobre seguridad concerniente al mantenimiento, uso y operación de este producto. Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor. Almacenar este manual en una localización segura para la referencia futura.
© 2008 Hatco Corporation
NOTICE
CAUTION
WARNING
CONTENTS
Important Owner Information...............................i
Introduction...........................................................i
Important Safety Information..............................1
Model Designation...............................................2
Model Description................................................2
All Models........................................................2
Specifications.......................................................3
Plug Configurations .........................................3
Electrical Rating Chart.....................................3
Dimensions......................................................4
Installation............................................................5
General............................................................5
Operation..............................................................6
Maintenance .........................................................8
Troubleshooting Guide........................................9
Accessories........................................................11
Hatco Limited Warranty.....................................13
Authorized Parts Distributors...........Back Cover
IMPORTANT OWNER INFORMATION
Record the model number, serial number (located on the top of the unit), voltage, and purchase date of your Flav-R-Savor®Heated Air Curtain Cabinet in the spaces below. Please have this information available when contacting Hatco for service assistance.
Model No. ________________________________ Serial No. ________________________________ Voltage __________________________________ Date of Purchase __________________________
Business 8:00 a.m. to 5:00 p.m. Hours: Central Standard Time
Telephone: (800) 558-0607; (414) 671-6350 Fax: (800) 690-2966 (Parts and Service)
Leg Assembly ..................................................5
General............................................................6
Serving Instructions.........................................7
General............................................................8
Cleaning...........................................................8
(Summer Hours: June to September – 8:00 a.m. to 5:00 p.m. C.S.T. Monday through Thursday 8:00 a.m. to 2:30 p.m. C.S.T. Friday)
(414) 671-3976 (International)
24 Hour 7 Day Parts and Service
Assistance available in the United States and Canada by calling (800) 558-0607.
INTRODUCTION
The patented Hatco Flav-R-Savor Heated Air Curtain Cabinets are designed to hold prepared foods for prolonged periods of time while maintaining that “just-made” quality. Warm air is forced downward through ducts in front of the cabinet opening, creating and maintaining ideal holding temperatures without the use of doors. The heated air is slowly drawn to the center and sides of the cabinet, warming the food as it flows to the perforations on the cabinet walls. The Heated Air Curtain cabinet allows for immediate access to food products and provides the best environment for wrapped or unwrapped sheet pan foods.
Hatco Flav-R-Savor HeatedAir Curtain Cabinetsare products of extensive research and field testing. The materials used were selected for maximum durability, attractive appearance, and optimum performance. Every unit is inspected and tested thoroughly prior to shipment.
Additional information can be found by visiting our web site at www.hatcocorp.com.
This manual provides the installation, safety, and operating instructions for Flav-R-Savor Heated Air Curtain Cabinets. Hatco recommends all installation, operating, and safety instructions appearing in this manual be read prior to installation or operation of a Heated Air Curtain Cabinet
Safety information that appears in this manual is identified by the following signal word panels:
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to personal injury.
i
Form No. FS2HACM-0608
IMPORTANT SAFETY INFORMATION
WARNING
NOTICE
CAUTION
WARNING
Read the following important safety information before using this equipment to avoid serious injury or death and to avoid damage to equipment or property.
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical outlet of the correct voltage, size, and plug configuration. If the plug and receptacle do not match, contact a qualified electrician to determine and install the proper voltage and size electrical outlet.
• Units supplied without an electrical plug require field installation of the proper plug. Plug must be properly grounded and of the correct voltage, size, and configuration for the electrical specifications of the unit. Contact a qualified electrician to determine and install the proper electrical plug.
• Turn the power switch OFF, unplug the power cord, and allow the unit to cool before performing any maintenance or cleaning.
• DO NOT submerge or saturate with water. Unit is not waterproof. Do not operate if unit has been submerged or saturated with water.
• Unit is not weatherproof. Locate the unit indoors where the ambient air temperature is a minimum of 70°F (21°C).
• This unit is not “jet-proof” construction. Do not use jet-clean spray to clean this unit.
• Do not steam clean or use excessive water on the unit.
• Do not pull unit by power cord.
• Discontinue use if power cord is frayed or worn.
• Do not attempt to repair or replace a damaged power cord. The cord must be replaced by Hatco, an Authorized Hatco Service Agent, or a person with similar qualifications.
• Use only Genuine Hatco Replacement Parts when service is required. Failure to use Genuine Hatco Replacement Parts may subject operators of the equipment to hazardous electrical voltage, resulting in electrical shock or burn. Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used. Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment.
FIRE HAZARD: Locate the unit a minimum of 1″ (25 mm) from combustible walls and materials. If safe distances are not maintained, discoloration or combustion could occur.
This unit has no “user-serviceable” parts. If service is required on this unit, contact an Authorized Hatco Service Agent or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966; or International fax 414-671-3976.
BURN HAZARD: Some exterior surfaces on the unit will get hot. Use caution when touching these areas.
Locate the unit at the proper counter height in an area that is convenient for use. The location should be level to prevent the unit or its contents from falling accidentally and strong enough to support the weight of the unit and its contents.
The National Sanitation Foundation (NSF) requires that units over 36″ (914 mm) in length or weighing more than 80 lbs. (36 kg) either be sealed to or raised above the installation surface. If this unit cannot be sealed at the point of use, 4″ (102 mm) legs are included to allow for proper cleaning access below the unit.
Use non-abrasive cleaners only. Abrasive cleaners could scratch the finish of your unit, marring its appearance and making it susceptible to soil accumulation.
Do not lay unit on the side with the control panel or damage to the unit could occur.
Form No. FS2HACM-0608
1
MODEL DESIGNATION
F S 2 H A C - X P T
Flav-R-Savor
Style
Heated
Air
Curtain
Full-Size Pan Capacity
Pass-Through
MODEL DESCRIPTION
Figure 1. Model Designation
All Models
Flav-R-Savor HeatedAir Curtain Cabinets consist of an easy to clean stainless steel front panel and black powdercoat painted body. Features include easy-to-use digital controls, a lighted ON/OFF switch, a metal sheathed heating element, and a 6' (1829 mm) power cord with plug (FS2HAC-4PT CE export models come equipped with a 6' [1829 m] power cord, but may not have a plug, depending on the configuration). The temperature range of the Flav-R-Savor Heated Air Curtain Cabinets is 80°-200°F (27°-93°C).
FS2HAC-2PT Model
The FS2HAC-2PT is a two-pan, pass-through style unit that allows for food product access from either side. The unit is capable of holding two full-size sheet pans.
FS2HAC-4PT Model
The FS2HAC-4PT is a four-pan, pass-through style unit that allows for food product access from either side. The unit is capable of holding four full-size sheet pans.
Figure 3. FS2HAC-4PT Model
Figure 2. FS2HAC-2PT Model
2
Form No. FS2HACM-0608
Plug Configurations
WARNING
NEMA L14-20P
CEE 7/7 Schuko BS-1363
NEMA 6-15P
NEMA 6-20P
Units are supplied from the factory with an electrical cord and plug installed (plugs are supplied according to the applications). Some export units may require field installation of the proper plug.
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical outlet of the correct voltage, size, and plug configuration. If the plug and receptacle do not match, contact a qualified electrician to determine and install the proper voltage and size electrical outlet.
• Units supplied without an electrical plug require field installation of the proper plug. Plug must be properly grounded and of the correct voltage, size, and configuration for the electrical specifications of the unit. Contact a qualified electrician to determine and install the proper electrical plug.
SPECIFICATIONS
Figure 4. Plug Configurations
NOTE: Receptacle not supplied by Hatco.
Electrical Rating Chart
Model Voltage Hertz Watts Amps Plug Configuration Shipping Weight
FS2HAC-2PT 120/208 60 2978 12.4 NEMA L14-20P 165 lbs. (75 kg)
120/240 60 2978 12.4 NEMA L14-20P 165 lbs. (75 kg)
220 60 2924 13.3 NEMA6-15P 165 lbs. (75 kg)
240 60 2948 12.3 NEMA6-15P 165 lbs. (75 kg) 220-230 (CE) 50 2924–3196 13.3–13.9 CEE 7/7 Schuko 165 lbs. (75 kg) 230-240 (CE) 50 2708–2948 11.8–12.3 BS-1363 165 lbs. (75 kg)
FS2HAC-4PT 120/208 60 3378 14.1 NEMA L14-20P 190 lbs. (86 kg)
120/240 60 3378 14.1 NEMA L14-20P 190 lbs. (86 kg)
220 60 3324 15.1 NEMA6-20P 190 lbs. (86 kg)
240 60 3348 14.0 NEMA6-20P 190 lbs. (86 kg) 220-230 (CE) 50 3324–3632 15.1–15.8 CEE 7/7 Schuko 190 lbs. (86 kg) 230-240 (CE) 50 3076–3348 13.4–14.0 None 190 lbs. (86 kg)
The shaded areas contain electrical information for Export models only.
NOTE: Shipping weight includes packaging.
Form No. FS2HACM-0608