Harvard Apparatus Pump 11 Elite OEM, Pico Plus Elite OEM User Manual

Pump 11 Elite OEM Module Series
USER’S MANUAL
Harvard Apparatus Pump 11 Elite OEM Module Series
Publication 5420-007 Rev B
phone 800.272.2775 email bioscience@harvardapparatus.com
www.harvardapparatus.com
Pump 11 Elite OEM Module USER’S MANUAL
Table of Contents
SUBJECT PAGE NO.
General Information ........................................................................................................ 4
Safety Information .................................................................................................4
Warranty and Repair Information ...........................................................................5
Manual Description .....................................................................................5
Warranty .....................................................................................................5
Repair Facilities and Parts ...........................................................................5
Serial Numbers ...........................................................................................5
Calibrations .................................................................................................5
Specifications .........................................................................................................6
Product Overview ............................................................................................................. 8
Pump Models ........................................................................................................8
Table of Contents
2
Operating Instructions ...........................................................................................9
Power Connections ...............................................................................................9
Syringe Loading ...................................................................................................10
External Pump Control .........................................................................................11
Setting up HyperTerminal .........................................................................11
Pump Chain Commands ......................................................................................12
Using the Pump 11 Elite Series Pump Chain Commands ........................12
Error Messages ........................................................................................13
Command Errors .......................................................................................13
Argument Errors .......................................................................................13
System Commands ..................................................................................13
Run Commands ........................................................................................15
Rate Commands .......................................................................................15
Volume Commands ..................................................................................16
Time Commands ......................................................................................17
Digital I/O Commands ...............................................................................18
Internal Commands ..................................................................................18
Serial Command Notes .............................................................................18
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
SUBJECT PAGE NO.
Appendices ....................................................................................................................... 19
Appendix A: Syringe Volume/Diameter Reference Table ....................................19
Appendix B: Min/Max Flow Rates .......................................................................20
Appendix C: External Connections ......................................................................22
User I/O Connector Specifications ............................................................22
Utilizing USB Interface ..............................................................................23
RS-485 ......................................................................................................25
Legacy RJ-11 Option ................................................................................26
Appendix D: Maintenance ...................................................................................27
Maintenance .............................................................................................27
Upgrading Pump 11 Elite Series Software ...............................................28
Troubleshooting ........................................................................................29
Appendix E: Ordering Information .......................................................................30
Table of Contents
3
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
General Information
SAFETY INFORMATION
Please read the following safety precautions to ensure proper use of your syringe pump. If the equipment is used in a manner not specified, the protection provided by the equipment may be impaired.
To Prevent Hazard or Injury:
USE PROPER POWER SUPPLY
The pump is supplied with an approved power supply and line cord. To maintain the safety integrity of the device, use only the following power supplies:
Cui Inc. Globtek Inc. Model: 3A – 242DB24 Model: GT–41062–T3
Output: 24V – 1.0A Output: 24V – 0.75A Input: 100–240V~50–60 Hz 0.8A Input: 100–240V~50–60 Hz 0.6A
USE PROPER LINE CORD
Use only the specified line cord for this product and make sure line cord is certified for country of use. The operating voltage range for the Pump 11 Elite Series is 12-30 VDC. The universal power supply operating voltage range is 100-240 VAC, 50-60 Hz.
Table of Contents
4
GROUND THE PRODUCT
This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making any connections to the input or output terminals of the product, ensure that the product is properly grounded.
MAKE PROPER CONNECTIONS
Make sure all connections are made properly and securely. Any signal wire connections to the unit must be no longer than 3 meters.
OBSERVE ALL TERMINAL RATINGS
Review the operating manual to learn the ratings on all connections.
AVOID EXPOSED CIRCUITRY
Do not touch any electronic circuitry inside of the product.
AVOID PINCH HAZARD
A pinch hazard may exist between the pusher block and end blocks. Avoid placing fingers between these points while the pump is running.
DO NOT OPERATE WITH SUSPECTED FAILURES
If damage is suspected on or to the product do not operate the product. Contact qualified service personnel to perform inspection.
ORIENT THE EQUIPMENT PROPERLY
Do not orient the equipment so that it is difficult to operate the disconnection device.
PLACE PRODUCT IN PROPER ENVIRONMENT
Review the operating manual for guidelines for proper operating environments.
OBSERVE ALL WARNING LABELS ON PRODUCT
Read all labels on product to ensure proper usage.
CAUTION Refer to Manual
!
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
Protective Ground Terminal
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
WARRANTY AND REPAIR INFORMATION
CAUTION: REFER TO SAFETY INFORMATION AND SETTING UP THE
HARVARD APPARATUS PUMP 11 ELITE SERIES BEFORE PLUGGING
!
IN THE PUMP.
Manual Description
This manual is designed to provide all operational and Method information required to operate and maintain the Pump 11 Elite Syringe Pumps. The functions and features are described in the Technical Specifications section.
Warranty
Harvard Apparatus warranties this instrument for a period of two years from date of purchase. At its option, Harvard Apparatus will repair or replace the unit if it is found to be defective as to workmanship or materials. This warranty does not extend to damage resulting from misuse, neglect or abuse, normal wear and tear, or accident. This warranty extends only to the original consumer purchaser.
IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some states
do not allow this limitation on an implied warranty, so the above limitation may not apply to you.
If a defect arises within the warranty period, promptly contact Harvard Apparatus, 84 October Hill Road, Holliston, Massachusetts 01746 using out toll free number 1-800-272-2775 or outside the US call 1–508-893-
8999. Email address is bioscience@harvardapparatus.com. Goods will not be accepted for return unless an RMA (returned materials authorization) number has been issued by our customer service department. The customer is responsible for shipping charges for non-warranty repairs. Please allow a reasonable period of time for completion of repairs or replacement. If the unit is replaced, the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device.
This warranty gives you specific rights, and you may also have other rights which vary from state to state.
General Information
5
Repair Facilities and Parts
Harvard Apparatus stocks replacement and repair parts. When ordering, please describe parts as completely as possible, preferably using a part number obtained from our Technical Support department. If practical, enclose a sample part or sketch. We offer a complete reconditioning service.
Serial Numbers
All inquiries concerning our product should refer to the serial number of the unit, located on the rear panel.
Calibrations
All electrical apparatus are calibrated at rated voltage and frequency. While the flow and volume will stay calibrated, the peak pressure may vary. Harvard Apparatus recommends an annual calibration of the pump.
CAUTION: FOR RESEARCH USE ONLY. NOT FOR CLINICAL USE ON PATIENTS.
!
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
Specications Pump 11 Elite OEM Pico Plus Elite OEM
Accuracy
Reproducibility
Syringes (Min./Max.)
Flow Rate:
Minimum (0.5 µl syringe)
Maximum (10 ml syringe)
Maximum (60 ml syringe)
Display
Non-Volatile Memory
Connectors:
RS-485
USB
I/O & TTL
Footswitch
RS-232 (option)
Linear Force (Max)
Drive Motor
Motor Drive Control
Number of Microsteps per one rev. of Lead Screw
Step Resolution
Step Rate:
Minimum
Maximum
Pusher Travel Rate:
Minimum
Maximum
Input Power
Input Power Connection
Power Supply
Dimensions 24.13 x 17.15 x 10.67 cm (9.5 x 6.75 x 4.2 in) 24.13 x 17.15 x 10.67 cm (9.5 x 6.75 x 4.2 in)
Weight
General Information
± 0.5% ± 0.35%
± 0.05% ± 0.05%
0.5 µl / 60 ml (10 ml dual) 0.5 µl / 10 ml
1.26 pl/min 0.54 pl/min
26.02 ml/min 11.70 ml/min
88.40 ml/min N/A
None None
Stores all settings Stores all settings
IEEE-1394, 6 pos IEEE-1394, 6 pos
Type B Type B
15 pin D-Sub Connector 15 pin D-Sub Connector
Mini phono jack Mini phono jack
RJ-11 RJ-11
16 kg (35 lbs) @ 100% Force Selection 16 kg (35 lbs) @ 100% Force Selection
0.9° Stepper Motor 0.9° Stepper Motor
Microprocessor with 1/16 microstepping Microprocessor with 1/16 microstepping
15,360 20,480
0.069 µm/µstep 0.031 µm/µstep
27.5 sec/µstep 27.5 sec/µstep
26 µsec/µstep 26 µsec/µstep
0.15 µm/min 0.068 µm/min
159.00 mm/min 71.55 mm/min
12-30 VDC (24V recommended) 12-30 VDC (24V recommended)
2.5mm ID x 5.5mm OD male plug 2.5mm ID x 5.5mm OD male plug
100-240 VAC, 50-60 Hz, 8 Watts Universal Power Supply, Use Only a Harvard Apparatus Approved Power Supply and Line Cord
2.3 kg (5.08 lbs) 2.3 kg (5.08 lbs)
100-240 VAC, 50-60 Hz, 8 Watts Universal Power Supply, Use Only a Harvard Apparatus Approved Power Supply and Line Cord
6
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
Specifications Pump 11 Elite OEM Pico Plus Elite OEM
Atmospheric Specifications:
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Method of Operation
Classification
Pollution Degree
Installation Category
Supplier Name
Supplier Address
Supplier Phone Number
Regulatory Certifications
Safety Declarations
General Information
4°C to 40°C (40°F to 104°F) 4°C to 40°C (40°F to 104°F)
-10°C to 70°C (14°F to 158°F) -10°C to 70°C (14°F to 158°F)
See Chart Below See Chart Below
20% to 80% RH, non condensing 20% to 80% RH, non condensing
Continuous Continuous
Class I Class I
1 1
II II
Harvard Apparatus Harvard Apparatus
84 October Hill Rd., Holliston, MA 01746 84 October Hill Rd., Holliston, MA 01746
(508) 893-8999 (508) 893-8999
CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme CE, ETL (UL, CSA), WEEE, EU RoHS & CB Scheme
ANSI/UL 61010-1 ED. 3 ; CAN/CSA C22.2 No. 61010-1Ed 3 ; IEC 61010-1 Ed 3 ; CENELEC EN 61010-1 ; CB Scheme
ANSI/UL 61010-1 ED. 3 ; CAN/CSA C22.2 No. 61010-1Ed 3 ; IEC 61010-1 Ed 3 ; CENELEC EN 61010-1 ; CB Scheme
7
EMC Declaration
FCC 47CFR 15B Class A; EN61326-1 FCC 47CFR 15B Class A; EN61326-1
phone 508.893.8999 fax 508.429.5732 e-mail techsupport@harvardapparatus.com
web www.harvardapparatus.com
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
Product Overview
Product Overview
8
The Harvard Apparatus Pump 11 Elite Series is the next generation of syringe pumps.
A green led light on the front panel makes it easy to see if the pump is running.
The pumps are versatile and can be interconnected through the RS-485 interface. Pump 11 Elite Series models can be mixed and matched in the daisy chain offering maximum flexibility. Up to 99 pumps can be linked together through the RS-485 interface provided each pump is assigned its own unique pump address.
Flow performance is optimized with a small step angle stepping motor that drives a precision lead screw and pusher block. The syringe mechanism is easy to use and securely holds the syringes for smooth flow performance.
Advanced microstepping techniques are employed to further reduce the step angle to eliminate flow pulsation. The accuracy is 0.5% (0.35% for Pico Plus Elite). A wide dynamic flow range from 1.26 pl/min to
88.40 ml/min (0.54 pl/min to 11.70 ml/min for the Pico Plus Elite) can be programmed into the pump. Flow rates are selectable with user selected engineering units from ml, µl, nl, pl, and hours, minutes and seconds.
Up to 16 kg (35 lbs) of linear force is available. This force is user adjustable to ensure the right force is applied for the various syringe sizes.
Easy external connections to a computer or other control devices are made through USB interface. Simple ASCII commands make communication with the pump easy. For direct control of the pump, the user can use the I/O interface (15pin Dsub). One trigger output and a trigger input in for external events such as a process parameter are available. The footswitch input will allow the control of the pump through an external device. The unit also has an output for run indication allowing connection to a remote LED.
The 11 Elite OEM Pumps are available with single and dual syringe options. Complete flexibility is offered with the ability to use most manufacturers syringes ranging from 0.5 µl to 60 ml single syringe and 5 µl to 10 ml dual syringe.
Pump Models
Single Syringe Infuse/Withdraw Programmable
Dual Syringe Infuse/Withdraw Programmable
Pico Plus (dual) Infuse/Withdraw Programmable
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
OPERATING INSTRUCTIONS
I/O Connector
Product Overview
9
DC Power Input
Main Switch
Foot Switch
USB Serial Input
(Type B)
RS-485 Connection
(Pump to Pump)
*Power Source -
When powering a pump in a chain through an RS­485 cable, toggle switch to RS-485. Only one pump can be powered from master through RS-485
POWER CONNECTIONS
1. Plug the power cord in. The Pump 11 Elite Series has a DC power input connector on the rear of the unit. The operating range for the Pump 11 Elite Series series is 12-30 Vdc.
2. Turn on the main power switch.
CAUTION: DO NOT CONNECT TO FIREWIRE PORTS ON A COMPUTER.
Best performance guaranteed when using 24V power supply.
!
DAMAGE MAY OCCUR TO THE PUMP OR COMPUTER.
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B
Pump 11 Elite OEM Module USER’S MANUAL
SYRINGE LOADING
12
Product Overview
10
2 4 5 3
6
7
1
9
The Pump 11 Elite Series can accommodate up to two syringes. Depending on the mechanism, any type of syringe, glass, plastic or stainless steel can be used. The Pump 11 Elite OEM Module can accommodate from 0.5 µl to 60 ml single syringe and 0.5 µl to 10 ml dual syringe. The syringe barrel clamp should be flipped for syringes larger than 30 ml.
1. Press the release button (1) and move the pusher block (2) to the approximate length of the syringe.
2. Unscrew the bracket clamping knobs (7,8) to loosen the retaining brackets (4,5) on the pusher block (2) and the Syringe holder block (3).
3. Unscrew the syringe barrel clamp by unscrewing the syringe barrel clamp knob (6).
4. Place the syringe on the syringe holder block (3). Ensure the barrel flange is with in the syringe holder’s block’s retaining bracket (5) and the plunger flange is in the pusher block’s retaining bracket.
*The Pico Plus Elite can accomodate from 0.5 µl
to 10 ml.
5. Screw down the syringe clamp knob (6)
> 30 cc syringes
11
10
8
until the syringe barrel clamp (10) is tight against the syringe barrel. Do not overtighten, especially when using glass syringes.
6. Secure the syringe flanges by pushing the retaining brackets (4,5) tightly against the syringe flanges using the bracket clamping knobs (7,8). The syringe plunger should be secured by the pusher block retaining bracket and the flange of the syringe should be secured by the syringe holder block retaining bracket.
7. Tighten the mechanical stop collars (9) using allen wrench (12) to prevent excess travel of the pusher block.
The syringe barrel clamp (10) may need to be flipped depending on your syringe size. To do so, completely unscrew and remove the syringe barrel clamp knob from the syringe block. Then remove lock nut (11). Flip the bracket and reassemble.
phone 508.893.8999 fax 508.429.5732 e-mail bioscience@harvardapparatus.com
web www.harvardapparatus.com
< 30 cc syringes
CAUTION: BE SURE MECHANICAL STOP COLLARS ARE POSITIONED
!
PROPERLY TO PREVENT THE PLUNGER FROM BOTTOMING OUT ON GLASS SYRINGES.
Pump 11 Elite OEM Module Series User’s ManualPublication 5420-007 Rev B