Harvard Apparatus 11, 55-1199, 55-4154 User Manual

Model ‘11’ Single Syringe 55-1199
Model ‘11’ Dual Syringe 55-4154
Model ‘11’
Syringe Pump Series
User’s Manual
1
SUBJECT PAGE NO.
Table of Contents ........................................................................1
General Information - Warranty and Repairs..............................2
Introduction ................................................................................3
Theory of Operation..............................................................3
Features ................................................................................3
New Pump 11, Front and Rear Views ..................................4
Installation ..................................................................................5
Initial Setup & Location Requirements ................................5
Loading the Syringe ..............................................................5
Fuse Replacement ................................................................6
Operation ....................................................................................7
Getting Started ......................................................................7
Turn Pump ON................................................................7
Function Keys and Run Indicator ..................................7
Entering Syringe Size ....................................................8
Entering Flow Rate Range ..............................................8
Entering Flow Rate ........................................................8
Press Run ........................................................................8
Check Syringe ................................................................8
Advanced Features ................................................................9
Volume Mode ..................................................................9
Power Failure ..................................................................9
Display Intensity ............................................................9
Changing Rates ............................................................10
Maintenance..................................................................10
Protecting Small, Fragile Syringes ..............................10
Appendices ....................................................................................
A. Specifications ................................................................11
B. Table of Popular Syringe Diameters ..............................12
C. Table of Minimum and Maximum Flow Rates ..............13
Table of Contents
2
General Information
Serial Numbers
All inquires concerning our product should refer to the serial number of the unit. Serial numbers are located on the rear of the chassis.
Calibrations
All electrical apparatus is calibrated at rated voltage and frequency. While the flow will stay calibrated, the peak will vary.
Warranty
Harvard Apparatus warranties this instrument for a period of one year from date of purchase. At its option, Harvard Apparatus will repair or replace the unit if it is found to be defective as to workmanship or material.
This warranty does not extend to damage resulting from misuse, neglect or abuse, normal wear and tear, or accident.
This warranty extends only to the original customer purchaser.
IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCI­DENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow exclu-
sion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. THERE ARE NO IMPLIED WARRANTIES OF
MERCHANTABILITY, OR FITNESS FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some states do not allow this limitation on an implied
warranty, so the above limitation may not apply to you.
If a defect arises within the one-year warranty period, promptly contact H
arvard Apparatus, Inc. 84 October Hill Road, Building 7, Holliston, Massachusetts 01746-1388 using our toll free number 1-800-272-2775. Goods will not be
accepted for return unless an RMA (returned materials authorization) number has been issued by our customer service department. The customer is responsible for shipping charges. Please allow a reasonable period of time for completion of repairs, replacement and return. If the unit is replaced, the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device.
This warranty gives you specific rights, and you may also have other rights which vary from state to state.
Repair Facilities and Parts
Harvard Apparatus stocks replacement and repair parts. When ordering, please describe parts as completely as possible, preferably using our part numbers. If prac­tical, enclose a sample or drawing. We offer a complete reconditioning service.
CAUTION
This pump is not registered with the FDA and is not for clinical use on human patients.
3
Introduction
Theory of Operation:
The new Pump 11 is designed as a low cost, highly precise, single syringe infusion pump capable of low to moderate back pressures.
The pump comes in two versions; one to hold one syringe of any make from 0.5 µl to 60ml and a second to hold two syringes of any make from 0.5 µl to 10 ml. The diam­eter of the syringe(s) is entered via the keyboard and the internal microprocessor drives a precision stepper motor to produce accurate fluid flow.
Non-volatile memory stores the last syringe diameter and flow rate along with other configuration data.
The “Power Failure Mode” can be set to either turn the pump off in the event of power failure or to resume pumping when power resumes.
Features:
Bright Display and Easy-To-Use Interface
A new, two-line 16 character vacuum fluorescent display along with six membrane keys make this a most attractive but powerful, easy-to-use syringe pump. Only two entries required to start pumping; syringe Inside Diameter (mm) and pumping flow rates. The Flow rate can be changed while the Pump is running.
Two Modes of Operation, Constant Flow Rate and Volume Dispense
The new Pump 11 will operate continuously in RATE mode or accurately dispense a specific amount of fluid in VOLUME mode.
Smooth Flow
New micro-stepping pump profiles deliver very smooth and consistent flow.
Nonvolatile Memory
The pump remembers its last syringe size, flow rate used and configuration settings.
Universal Power Supply
No need to change AC line switches, fuses or wires, the new Pump 11 will operate on any AC line voltage from 90 VAC to 240VAC, either 50 or 60 Hz.
Power Fail Mode
In a power failure the Pump can either RESUME or STOP pumping when power is returned.
CE Mark Approved
The new Pump 11 meets all relevant European EMC and Safety requirements for lab­oratory equipment.