Upblast Roof Ventilator – Series 61 (Direct Drive), Series 63 (Belt Drive)
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5
Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6
Upblast Roof Ventilator – Series 69 & 69S (Belt Drive, Motor Out of Airstream)
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11
Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12
Upblast Roof Ventilator – Series 69H Smoke Ventilator
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 14
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 15
Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16
Hooded Roof Ventilator – Series 15 (Direct Drive), Series 16 (Belt Drive), Series 17 (Reversible)
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 17
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 18
Direct Drive Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19
Belt Drive Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 20
Reversible Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 21
Filtered Unit Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 22
Filtered Unit Performance – Direct Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 23
Filtered Unit Performance – Belt Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 24
Hoodjet Roof Ventilators – Series 71J, 73J & 75J
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 25
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 25
Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26
Recirculating Roof Ventilators – Series 26 & 27
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 27 & 29
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 28 & 30
Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 28 & 30
Roof Ventilator Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 33 & 34
Index
2
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Page 3
This bulletin lists Hartzell’s line of Power Roof Ventilators and accessories. More than 70 Hartzell offices can provide specific performance and installation data to meet your requirements. Call your Hartzell representative for assistance. Visit our website (www.hartzellfan.com) or call toll-free for the name of your Hartzell representative…
1-800-336-3267
Certified Ratings for Sound and Air Performance
Hartzell Fan, Inc. certifies that the Belt Drive Upblast Roof Ventilator, Series 69, on pages 9, 11, 12 and 13 and Belt Drive Upblast Smoke Ventilator, Series 69H, on pages 14-16, are licensed to bear the AMCA Seal for air and sound. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Sound performance data is available upon request. Please contact the factory and ask for Engineering Publication #SD-157 for Series 69 and #SD-159 for Series 69H.
Power Roof Ventilator Selection
The Hartzell Power Roof Ventilator performances on the following pages are based on standard air conditions (sea level, 70°F., and 29.92 inches barometric pressure). Performance data does include drive losses on belt drive units.
When placing your order, be sure to specify the Hartzell Model Code.The following example demonstrates our coding system. The illustrated Series Number specifies a Hartzell Series 61 Fan.
Be sure to include fan model, performance requirements, operating temperature, motor data (enclosure, voltage, mounting position, etc.) and a list of required accessory items. (See pages 22 and 23.)
Refer to pages 31 and 32 for more detailed information on Roof Ventilator Application. For upblast ventilators, refer to CFM limitations on pages 8 and 13.
Contact your local Hartzell Sales Representative for assistance.
Motor RPM/Phase
3 Phase
2 = 3450 3 = 1750 4 = 1140 5 = 870 6 = 690 7 = 575
1 Phase
B = 3450 C = 1750 D = 1140 E = 870 F = 690 G= 575
A61–G–363–L–––S TAOG4
Type
A – Production Item S – Stock Item
Q – Special Quote Product Series Duty (G or H) Size (nominal wheel diameter, inches) No. of Blades Wheel Code Blade Angle, no decimal (applies to adjustable pitch fans only) Material of Construction Motor Enclosure Motor Horsepower Motor RPM/Phase
Hartzell Model Explanation
How To Use Model Code Index:
Example – Assume a needed performance of 8,400 CFM at 0" S.P.W.G. at standard conditions is required for an exhaust application. Reading the
rating table on page five; a 24", series 61, direct drive upblast roof ventilator operating at 8380 CFM at 0" SP. It is also determined from the rating table the ventilator will consist of the following: standard construction, 1140 RPM totally enclosed air over motor, and a three blade lo-noise propeller. Knowing this the model code can be constructed as follows: the fan is a direct drive upblast roof ventilator, therefore, the series is “61”, “G” (General Industrial) Duty construction; the size is “24”; the propeller is a lo-noise, therefore, blade is “L”; the construction is standard, therefore, material is “ST”, the motor is a totally enclosed air over, therefore, the enclosure is “AO”, the horsepower required is .68 BHP, therefore, the horsepower code is “G”, and the motor RPM is 1140, therefore, the RPM code is “4”.
Note: 1) All other informational fields must be filled with hyphens/dashes (–) if they are not applicable to the fan being considered.
Motor Horsepower
Horsepower
1
/41/31/23/4 111/2 23571/2 10 15 20 25 30 40 50 60
Code Letter D E F G H I J K L M N O P Q R S T U
3
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Certificates of Design Assessment are issued by the American Bureau of Shipping. The assessment is a representation by the Bureau as to
the degree of compliance the design
exhibits with applicable sections of the Rules. The certificates, by itself, do not reflect that the products are
Type Approved.
Page 4
4
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Upblast (Direct Drive & Belted)
Series 61 – Direct Drive
The Series 61 upblast ventilator meets the need for an economical, yet efficient upblast roof ventilator. The Series 61 unit combines the Hartzell ring fan concept with a windband and butterfly damper.Dampers open automatically when the fan goes on, close weathertight when the fan is shut down. When the unit is in operation, the force of the discharge air effectively prevents the entry of rain or snow.
Series 63 – Belted
The belted upblast ventilator, Series 63, offers the same design and efficient performance as the direct drive model, along with the added dividend of an economical approach to a low speed, quiet upblast roof ventilator. The belted arrangement eliminates the need for costly, low-speed motors for direct drive operation. Since the drive assembly is in the ventilator’s airstream, the unit should not be used to handle high temperatures or dirt-laden air.
Features:
Sizes Direct Drive (Series 61) – 12"-72"… performance from
1,390 to 88,000 CFM at free air. Belted (Series 63) – 24"- 84"… performance from 5,080 to 124,500 CFM at free air.
Construction – steel construction is standard; aluminum
construction is available for “H” Duty only. Sizes through 60" include painted, galvannealed weather exposed components.
Series 61
“G” Duty Shown
Series 63
“H” Duty Shown
On sizes 66" and larger, windband and panel are painted hot rolled steel with industrial grade enamel. Motor base is heavy gauge plate, welded to solid steel rod frame.
Motor Mount – “G” (General Industrial) Duty construction
features an adjustable steel motor base and tubular steel frame, which are over-sized to provide structurally rugged construction. “G” Duty is available as Series 61 and 63 in sizes 18" to 48" and will be limited by HP and RPM on certain sizes. Please reference the performance rating tables, the shaded models are those models offered as “G” Duty.
“H” (Heavy Industrial) Duty construction features solid rolled rod supports, welded to the fan panel and motor mounts to provide support for the motor. The steel motor base and solid steel support rods are oversized to provide structurally rugged construction. “H” Duty is available in all sizes and models.
Propellers – cast aluminum airfoil type. SERIES 61 – DIRECT DRIVE –
Sizes: 12" - 44" – 6-blade, Type P
12" - 14" – 4-blade, Type O 16" - 40" – 4-blade, Type W 20" - 60" – 3-blade, lo-noise, Type L 20" - 60" – 2-blade, Type N 48" - 72" – 4-blade adjustable, Type A 60" – 4-blade adjustable, Type AW 60" – 4-blade adjustable, Type BA
SERIES 63 – BELTED –
Sizes: 24" - 60" – 3-blade lo-noise, Type L
54" - 60" – 6-blade adjustable, Type AW 66" – 4-blade adjustable, Type BA 72" - 84" – 4- and 6-blade adjustable, Type A
Note: The above adjustable blades are merely a
representative group of blades available. Many other adjustable blades and blade angles can be furnished. Contact your Hartzell representative for assistance.
Motors – totally enclosed fan cooled motors are standard. Special motors are available upon request.
Drive Assembly Belted Only – drives are constant speed and are sized to handle 20% or more horsepower than the cat­alog motor is rated.
Orifice Panel – sizes 12"- 60"… features painted galvannealed steel venturi panel. Sizes 66"- 84"… formed steel panel with angle ring orifice.
Windband – rolled, welded construction. Windband effectively prevents wind resistance against the operation of the ventilator. A rolled angle on top and bottom of the windband is standard to provide additional support. Removable windband for ease of maintenance of motor and drive assembly is standard through 60".
Dampers – semicircular lids at the base of the windband are mounted on corrosive resistant stainless steel rods which turn in plastic bearings. Bearings will not rust or stick, and require no lubrication. Lids open automatically when the fan turns on, closes weathertight when the fan shuts off. Damper lids on all sizes are constructed of galvanized steel as standard. Aluminum and fiberglass damper lids are also available. See Page 7 for CFM Limitations for Damper Lid Operation.
Coatings – special coatings are available upon request.
Extended Lube Tubes – will be provided from the motor on direct drive units and from the bearings and motor on belt drive and belted units to the exterior of the housing only when the motor is designed for external lubrication fittings (relubricable versus sealed motor bearings).
Pre-Assembled Units – 12" to 60" shipped in one piece. 66" through 84", the stack cap is shipped separately.
Options and Accessories – see pages 33 and 34.
ABS Certificate
of Design Assessment
Received
Page 5
F max
Max Motor Weight (less motor
Frame Size and options)
61 63 61 63 61 63
Fan
ABDE
“G” “H” “G” “H”
G
JK
“G” “H” “G” “H”
Galv Alum Galv Alum
Size Duty Duty Duty Duty
Galv Alum Galv Alum
Duty Duty Duty Duty
12 18 22 12 143⁄4 -- 12 -- -- 2 14 0.125 20 0.064 -- 56 -- -- 44 33 -- -- 14 20 24 12 143⁄4 -- 12 -- -- 2 14 0.125 20 0.064 -- 56 -- -- 50 37 -- -- 16 22 26 12 143⁄4 -- 12 -- -- 2 14 0.125 20 0.064 -- 56 -- -- 51 38 -- -- 18 24 28 20 223⁄4 101⁄2 12 -- -- 2 14 0.125 20 0.064 56 56 -- -- 77 57 -- -- 20 26 30 20 223⁄4 101⁄2 12 -- -- 2 14 0.125 20 0.064 143T 56 -- -- 85 63 -- -- 24 30 36 20 231⁄2 101⁄2 111⁄2 121⁄2 151⁄8 23⁄4 14 0.125 20 0.064 145T 184T 56 145T 124 93 117 88 28 34 42 20 231⁄2 123⁄4 11 121⁄2 161⁄4 23⁄4 14 0.125 20 0.064 145T 184T 56 145T 135 101 124 93 32 38 42 26 291⁄2 14 11 121⁄2 181⁄4 23⁄4 14 0.125 20 0.064 184T 184T 145T 184T 169 126 210 157 36 44 48 26 291⁄2 151⁄2 141⁄2 151⁄2 177⁄8 23⁄4 14 0.125 20 0.064 213T 215T 145T 184T 175 126 191 143 40 48 50 26 291⁄2 151⁄2 195⁄8 151⁄2 181⁄4 23⁄4 14 0.125 20 0.064 215T 256T 182T 184T 227 170 241 181 44 52 54 38 411⁄2 18 195⁄8 141⁄2 225⁄8 23⁄4 14 0.125 16 0.100 254T 256T 184T 215T 275 165 217 163 48 56 60 38 421⁄2 18 185⁄8 141⁄2 215⁄8 33⁄4 14 0.125 16 0.100 254T 256T 184T 215T 409 263 291 218 54 62 641⁄4 38 421⁄2 -- 211⁄8 -- 211⁄2 33⁄4 14 0.125 16 0.100 -- 286T -- 256T 628 432 586 440 60 68 701⁄4 38 421⁄2 -- 211⁄8 -- 211⁄2 33⁄4 14 0.125 14 0.100 -- 286T -- 256T 640 437 486 364 66 761⁄2 793⁄4 365⁄8 405⁄8 -- 28 -- 44 4
1
4 0.375 10 0.190 -- 326T -- 256T 484 363 532 399
72 821⁄2 853⁄4 365⁄8 405⁄8 -- 291⁄2 -- 44 4
1
4 0.375 10 0.190 -- 365T -- 286T 1150 862.5 966 724.5
84 95 981⁄4 425⁄8 465⁄8 -- -- -- 49 4
1
4 0.375 10 0.190 -- -- -- 324T -- --
1447.7 1085.78
TUBES (OPTIONAL)
EXTERNAL LUBE
Dimensions
NOTE: Dimensions and specifications are subject to change. Certified prints are available.
Maximum installation weight less motor and any optional equipment.
Principal Dimensions – Series 61 and 63 (Inches)
Series 63
Series 61
5
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
EXTERNAL LUBE TUBES (OPTIONAL)
-GA. WINDBAND
MAX.
RUBBER "U" MOLD (NOT SHOWN)
AIRFLOW
GA.
I.D.
SQUARE INSIDE
ROLLED FLANGE BOTH ENDS
3/4
-GA. WINDBAND I.D.
ROLLED FLANGE BOTH ENDS
RUBBER "U" MOLD (NOT SHOWN)
AIRFLOW
MAX.
GA.
SQUARE INSIDE
3/4
Page 6
Blade
Motor
Peak Fan
Size Model Code Angle HP RPM BHP
12"
A61---126-P---STFCD2
1
/4 3450 0.22 1832 1725 1615 1400 1155 55
A61---124-O---STFCD3
1
/4 1725 0.10 1390 1177 60
14"
A61---146-P---STFCD3
1
/4 1725 0.08 1705 1440 60
A61---144-O---STFCD3
1
/4 1725 0.17 2110 1820 66
16"
A61---166-P---STFCD3
1
/4 1725 0.17 2520 2250 60
A61---164-W---STFCD3
1
/4 1725 0.27 3040 2780 2500 67
A61---188-Q---STFCD3
1
/4 1725 0.26 3240 2945 2490 87
18"
A61---184WB---STFCE3
1
/3 1725 0.37 3850 3520 3225 91
A61---184WA---STFCF3
1
/2 1740 0.35 4055 3750 3475 95
A61---184WA---STFCD4
1
/4 1185 0.12 2765 82
20"
A61---203-L---STFCF3
1
/2 1725 0.47 4665 4290 3975 3490 103
A61---204-W---STFCG3
3
/4 1725 0.74 5900 5540 5200 4800 119
A61---242NA---STFCD3
1
/4 1725 0.28 5120 4150 123
A61---242NB---STFCF3
1
/2 1725 0.56 6630 5830 4980 131
A61---242NC---STFCG3
3
/4 1725 0.80 7400 6740 6000 5000 139
24"
A61---246PA---STFCH3 1 1750 1.12 8100 7680 7230 6770 6310 155 A61---246PB---STFCI3 11/2 1750 1.50 9060 8700 8300 7850 7250 163 A61---244-W---STFCJ3 2 1750 2.06 10380 9960 9550 9100 8630 167 A61---243-L---STFCE4
1
/3 1140 0.30 5375 4750 150
A61---244-W---STFCF4
1
/2 1140 0.57 6800 6140 5400 163
A61---282NA---STFCF3
1
/2 1725 0.45 7420 6320 138
A61---282NB---STFCG3
3
/4 1725 0.72 9280 8350 7300 5930 138
A61---282NC---STFCH3 1 1750 1.00 9850 8990 8050 7000 150
28" A61---286PB---STFCI3 11/2 1750 1.52 10300 9830 9360 8850 8300 174
A61---286PA---STFCJ3 2 1750 2.03 12080 11600 11100 10560 10000 178 A61---283-L---STFCG4
3
/4 1140 0.68 8380 7680 6900 5900 165 A61---284-W---STFCH4 1 1160 1.11 10400 9670 8920 8170 158 A61---322NB---STFCH3 1 1750 1.00 11820 10620 9330 7650 201 A61---322NA---STFCJ3 2 1750 2.02 15320 14370 13330 12250 11000 213
32"
A61---322NA---STFCF4
1
/2 1140 0.55 9930 8400 189 A61---323-L---STFCI4 11/2 1160 1.53 12630 11750 10900 9930 7900 241 A61---324-W---STFCJ4 2 1160 2.20 15170 14370 13550 12800 11700 249 A61---324-W---STFCH5 1 870 0.93 11410 10270 9100 229 A61---362NC---STFCJ3 2 1750 2.01 17270 15910 14470 12900 10970 222 A61---362NB---STFCK3 3 1750 2.82 20020 18850 17600 16600 15250 250 A61---366PA---STFCL3 5 1750 4.82 22650 22000 21300 20500 19550 282 A61---362NA---STFCH4 1 1160 1.12 14800 13500 11800 226
36" A61---363-L---STFCJ4 2 1160 2.33 17700 16830 15900 14930 13800 248
A61---366PB---STFCK4 3 1160 2.43 18600 17750 16500 15200 13700 382 A61---364-W---STFCL4 5 1160 3.83 22000 21150 20250 19400 18200 322 A61---363-L---STFCH5 1 870 0.98 13400 12250 10900 278 A61---364-W---STFCI5 11/2 870 1.64 16610 15370 13970 11950 290 A61---402NA---STFCJ4 2 1160 2.25 20630 19000 17200 15150 312 A61---406PA---STFCK4 3 1160 2.90 22200 20950 19600 18150 16300 356 A61---406PB---STFCL4 5 1160 4.90 25900 25000 24100 23050 21850 381
40"
A61---402NA---STFCH5 1 870 0.94 15550 13270 292 A61---406PA---STFCI5 11/2 870 1.25 16650 14900 12850 260 A61---403-L---STFCJ5 2 870 1.90 19230 18000 16630 15050 12000 340 A61---404-W---STFCK5 3 870 3.47 23380 22150 20700 19000 364 A61---404-W---STFCI6 11/2 690 1.67 18300 16600 14650 378 A61---442NB---STFCJ4 2 1160 2.17 23070 20800 18400 15050 341 A61---442NA---STFCK4 3 1160 3.50 27050 25150 23150 21200 18900 377 A61---446-P---STFCL4 5 1160 5.20 29600 28500 27300 26000 24650 389 A61---442NB---STFCH5 1 870 0.98 17730 14600 345
44" A61---442NA---STFCI5 11/2 870 1.53 20410 17970 15200 353
A61---446-P---STFCJ5 2 870 2.16 21900 20300 18600 16600 359 A61---443-L---STFCK5 3 870 3.20 24850 23550 22100 20600 18750 385 A61---444-W---STFCL5 5 870 5.10 30770 29450 27800 26150 24400 421 A61---443-L---STFCI6 11/2 690 1.49 19380 17700 15650 365 A61---482NC---STFCJ4 2 1160 2.15 25500 23200 20700 17750 419 A61---482NB---STFCK4 3 1160 3.12 28950 26600 24200 21400 18000 431 A61---482NA---STFCL4 5 1160 5.37 34350 32500 30400 28100 25550 447
48"
A61---484AA200STFCN4 20° 10 1160 9.32 40803 38834 36932 34978 32980 596 A61---482NA---STFCJ5 2 870 2.18 25450 22900 19750 455 A61---483-L---STFCL5 5 870 4.42 31250 29600 27850 26100 24100 543 A61---484AA230STFCK6 23° 3 690 2.31 25989 22881 19451 15714 539 A61---486AA245STFCL6 24.5° 5 690 3.34 29028 26276 23742 20778 17755 546
6
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Performance
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Net Inst.
Wt. #
Rating Table – Series 61 – Direct Drive
CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
Page 7
Blade
Motor
Peak Fan Fan
Size Model Code Angle HP RPM BHP RPM
24"
A63---243-L---STFCE3 1750 0.33 1071 5080 4380 139 A63---243-L---STFCF3 1750 0.52 1220 5780 5170 4500 139 A63---283-L---STFCE3 1750 0.32 883 6400 5410 151
28" A63---283-L---STFCF3 1750 0.52 1035 7500 6680 5780 151
A63---283-L---STFCG3 1750 0.76 1165 8470 7740 6960 6000 155 A63---323-L---STFCF3 1750 0.51 825 8850 7620 213 A63---323-L---STFCG3 1750 0.75 945 10100 9090 7940 217
32" A63---323-L---STFCH3 1 1750 1.02 1045 11180 10280 9250 8050 225
A63---323-L---STFCI3 1750 1.51 1190 12710 11900 11050 10140 8850 245 A63---323-L---STFCJ3 1750 1.98 1305 13940 13200 12430 11630 10770 245 A63---363-L---STFCG3 1750 0.77 764 11640 10300 238
36"
A63---363-L---STFCH3 1750 1.07 837 12760 11520 10080 262 A63---363-L---STFCI3 1750 1.68 980 14930 13930 12800 11350 266 A63---363-L---STFCJ3 2 1750 2.08 1050 16000 15080 14030 12820 11140 266 A63---403-L---STFCH3 1 1750 1.17 690 15280 13680 11600 312
40"
A63---403-L---STFCI3 1750 1.67 780 17230 15820 14220 11600 320 A63---403-L---STFCJ3 2 1750 2.31 870 19200 17900 16500 14870 332 A63---403-L---STFCK3 3 1750 3.30 980 21610 20500 19260 17980 16400 356 A63---443-L---STFCI3 1750 1.53 680 19440 17750 15420 385
44"
A63---443-L---STFCJ3 2 1750 2.00 738 21070 19550 17600 15150 389 A63---443-L---STFCK3 3 1750 3.02 853 24300 23000 21500 19750 17650 401 A63---443-L---STFCL3 5 1750 4.95 1010 28800 27700 26600 25150 23530 417 A63---483-L---STFCH3 1 1750 0.98 525 19000 455
48"
A63---483-L---STFCJ3 2 1750 2.02 660 23600 21600 19100 459 A63---483-L---STFCK3 3 1750 2.93 740 26400 24550 22500 20100 475 A63---483-L---STFCL3 5 1750 5.06 895 31930 30400 28800 27100 25250 491
Blade
Motor
Peak Fan
Size Model Code Angle HP RPM BHP
A61---542NB---STFCK4 3 1160 2.85 31950 28900 25500 580 A61---542NA---STFCL4 5 1160 5.04 40000 37500 34750 31900 28700 612 A61---542NC---STFCM4 71/2 1160 7.12 44700 42300 39800 37000 34150 640 A61---542NC---STFCK5 3 870 3.15 33550 30300 26550 21600 604
54" A61---544BA110STFCL5 11° 5 870 5.50 35950 33400 28500 22050 652
A61---544BA165STFCM5 16.5° 71/2 870 8.20 43100 40800 38100 33000 23250 692 A61---546BA175STFCN5 17.5° 10 870 11.00 47900 45750 43350 39500 32000 715 A61---544BA140STFCK6 14° 3 690 3.35 31550 28350 684 A61---546BA175STFCL6 17.5° 5 690 5.50 38100 35150 30600 20900 776 A61---602ND---STFCK4 3 1160 3.80 38000 32750 27700 625 A61---602NB---STFCL4 5 1160 5.15 44200 41600 37800 33500 29300 649 A61---602NC---STFCM4 71/2 1160 7.20 50700 47900 44500 41250 36800 685 A61---602NA---STFCN4 10 1160 10 57000 53800 49800 44950 40500 721 A61---602NC---STFCK5 3 870 3 38200 33800 28700 649 A61---602BA150STFCL5 15° 5 870 5.6 45630 42100 38150 33300 26650 677
60" A61---604BA130STFCM5 13° 71/2 870 8.4 50400 48250 45700 42850 39350 777
A61---604BA165STFCN5 16.5° 10 870 10.9 56750 54500 52050 49500 46800 905 A61---603-L---STFCO5 15 870 13.8 63000 61000 58900 56750 55000 929 A61---604BA100STFCK6 10° 3 690 3.3 35830 32100 28100 785 A61---604BA165STFCL6 16.5° 5 690 5.45 44970 41900 38900 34850 26600 797 A61---603-L---STFCM6 71/2 690 7 50000 47500 45000 42200 39000 829 A61---604AW250STFCN6 25° 10 690 10.9 59000 56600 54100 51500 48600 912 A61---664BA120STFCM5 12° 71/2 870 7.8 59300 55500 51700 48000 43800 730 A61---664BA160STFCN5 16° 10 870 11.25 68800 65300 61700 57800 53900 780
66"
A61---664BA200STFCO5 20 15 870 15 77500 74000 70500 67200 62600 830 A61---664BA100STFCK6 10° 3 690 3.15 43300 39300 34500 700 A61---664BA160STFCL6 16° 5 690 5.6 54600 50700 46900 42700 38400 730 A61---664BA210STFCM6 21° 71/2 690 8.15 63400 60000 55800 51700 47300 780 A61---724AA140STFCN5 14° 10 870 10.9 73200 68600 63000 57000 50000 1341 A61---724AA190STFCO5 19° 15 870 16.8 88000 83800 79000 73200 65500 1278
72" A61---724AA140STFCL6 14° 5 690 5.45 58700 52000 44300 1328
A61---724AA190STFCM6 19° 71/2 690 8.4 69700 63800 57600 46700 38000 1349 A61---724AA230STFCN6 23° 10 690 11.2 77300 72100 66300 54500 42200 1400
Rating Table – Series 61 – Direct Drive (Cont’d.)
Rating Table – Series 63 – Belted
CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. All belt drive fan ratings include transmission losses.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
7
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Net Inst.
Wt. #
CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Net Inst.
Wt. #
Page 8
8
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Rating Table – Series 63 – Belted (Cont’d.)
Fan Size
CFM 121416182024 2832364044485460667284
Minimum 1110 1490 1930 2425 2980 4255 5760 7490 9445 11630 14040 16680 21255 26170 30885 36755 50030 Maximum 2725 3670 4750 5975 7335 10475 14175 18435 23250 28630 34560 41055 52315 64410 76025 90480 123150
CFM Limitations for Damper Lids Operation Series 61 and 63
Minimum CFM to open lids Maximum CFM to prevent lid damage
Blade
Motor
Peak Fan Fan
Size Model Code Angle HP RPM BHP RPM
A63---543-L---STFCJ3 2 1750 1.87 497 26050 22950 564 A63---543-L---STFCK3 3 1750 3.00 573 30000 27400 24000 584
54"
A63---543-L---STFCL3 5 1750 4.86 671 35150 33050 30600 27300 604 A63---543-L---STFCM3 71/2 1750 7.83 786 41200 39350 37400 35250 32500 632 A63---544AW220STFCL3 22° 5 1750 5.31 645 38500 36400 33900 605 A63---544AW220STFCM3 22° 71/2 1750 8.02 737 42950 42200 40150 37950 655 A63---603-L---STFCK3 3 1750 3.00 496 35100 31750 27400 665 A63---603-L---STFCL3 5 1750 5.10 595 42000 39300 36300 32400 685 A63---603-L---STFCM3 71/2 1750 7.50 672 47500 45000 42400 39400 35700 745
60" A63---603-L---STFCN3 10 1750 10.00 747 52850 50700 48400 45750 53000 765
A63---603-L---STFCO3 15 1750 14.90 858 60750 58750 56700 54600 52400 832 A63---604AW250STFCM3 25° 71/2 1750 7.85 603 51200 48800 46000 42500 33500 745 A63---604AW250STFCN3 25° 10 1750 10.60 665 56400 54400 52000 49200 45600 765 A63---664BA220STFCK3 22° 3 1750 3.30 486 45800 40600 34200 688 A63---664BA220STFCL3 22° 5 1750 5.60 575 54400 50000 45300 39500 700
66" A63---664BA220STFCM3 22° 71/2 1750 8.20 652 61400 57800 53800 49400 43700 727
A63---664BA220STFCN3 22° 10 1750 11.00 720 68000 64500 61000 57300 53000 748 A63---664BA220STFCO3 22° 15 1750 16.06 818 74000 71300 67800 64500 795 A63---724AA220STFCL3 22° 5 1750 5.50 531 60300 53500 38000 1204 A63---724AA160STFCM3 16° 71/2 1750 7.81 690 64700 59300 52000 41500 1224
72"
A63---726AA225STFCM3 22.5° 7
1
/2 1750 8.15 531 67200 61700 54000 1244 A63---726AA160STFCN3 16° 10 1750 11.00 690 71300 67200 62000 55700 48500 1284 A63---726AA250STFCO3 25° 15 1750 16.80 637 85700 81300 76600 70800 1296 A63---726AA250STFCP3 25° 20 1750 21.40 690 88800 84500 79500 1351 A63---844BA160STFCL3 16° 5 1750 5.83 455 74300 66800 59000 1672 A63---844BA170STFCM3 17° 71/2 1750 8.30 500 84000 77500 70200 64500 53600 1806 A63---844BA210STFCN3 21° 10 1750 11.20 500 94500 88000 81500 73700 63600 1840
84" A63---846BA250STFCO3 25° 15 1750 16.23 455 105700 100000 94000 88000 80500 1978
A63---844BA270STFCP3 27° 20 1750 22.00 546 117700 112000 105800 99000 91000 1978 A63---846BN300STFCO3 30° 15 1750 16.23 364 110000 104500 98000 90600 2032 A63---844BN290STFCP3 29° 20 1750 21.73 455 118400 112500 106000 98000 2002
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Net Inst.
Wt. #
CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. All belt drive fan ratings include transmission losses.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
Page 9
Upblast (Belt Drive)
Features:
Sizes – 12" through 84"… performance from 1,455 to 117,000 CFM at free air.
Construction – sturdy, three-piece unit. Fan is heavy gauge painted hot rolled steel, as standard construction. Aluminum construction is available. Seams are continuously welded. Curb panel features a venturi orifice to provide minimal entry losses and permit efficient fan operation. Venturi panel is painted galvannealed steel. Panel and fan are bolted together for ease of installation and maintenance. Stack cap is constructed of galvannealed steel in sizes 12" through 60" with self formed flanges top and bottom for additional strength; painted hot rolled steel, size 66" and larger. Butterfly dampers open when the unit is on, close weathertight when the unit is off. Discharge airstream prevents entry of rain or snow during operation. A rolled angle ring on top of the windband is standard on sizes 44" and larger to provide additional support. Damper lids are constructed of galvanized steel for all sizes as standard; aluminum and fiberglass lids are available. Lifting eyes are standard.
Coatings – standard finish is an industrial grade enamel suitable for interior or exterior industrial applications. Other coat­ings are available upon request.
Propellers – cast aluminum airfoil type. Sizes: 18" - 48" – 6-blade, Type W Sizes: 54" - 60" – 3-blade lo-noise, Type L Size: 66" – 4-blade adjustable, Type BA Sizes: 72" - 84" – 4- and 6-blade adjustable, Type A
Note: The above blades are merely a representative group
of possible selections for these ventilators. Many other fixed and adjustable pitch blade selections can be furnished. Contact your Hartzell representative for assistance.
Pre-Assembled Units – 12" to 48" shipped in one piece. 54" through 84", stack cap is shipped separately.
Motors – open drip proof are standard. Special motors are available upon request. Motor covers and drive guards are avail­able. Motors are mounted out of the airstream.
Drive Assembly – variable pitch drives are standard on units up to 10 HP, enabling speed reduction of 20% from the maximum fan RPM setting. Drives are sized for continuous duty. Propeller shaft rotates in two ball-type bearings mounted on structural inner steel support.
Drive Protection – drive components (belts, sheave, shaft and bearings) are enclosed in an inner drum and protected from the airstream. This casing is positioned on the negative air pressure side of the propeller. Access to shaft and bearings is through a removable bearing cover. Shaft seal and cover plate are standard.
Lubrication Tubes – extended from the bearings through the belt tube to the exterior of the fan housing. This standard feature permits easy maintenance.
Options and Accessories – see pages 33 and 34.
The Series 69 roof ventilator meets the need for a heavy-duty belt drive, upblast ventilator with the motor out of the airstream. This unit features a belt drive duct fan mounted on a spun venturi panel with a stack cap backdraft damper. It is of sufficient height to ensure projection of air and exhaust fumes up and away from the roof of the building. The Series 69 upblast roof ventilator can be built with most of Hartzell’s tubeaxial fans.
NOTE: Many other selections not cataloged in this rating table are available. Contact your local Hartzell representative for selections and assistance.
Hartzell Fan, Inc. certifies that the Series 69, Belt Drive Upblast Roof Ventilator, shown hereon are licensed to bear the AMCA Seal for air and sound. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311, and comply with the requirements of the certified Ratings Program.
Sound performance data is available upon request. Please contact the factory and ask for Engineering Publication #SD-157.
Series 69
9
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Page 10
10
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Upblast (Belt Drive-Motor Out of Airstream)
Easy Access
Swingout construction provides easy, safe access to internal fan components for inspection, cleaning, maintenance or repair without removing the entire fan assembly or having personnel working directly over the roof opening.
Fan housing is split and swings out from the assembly on a heavy duty hinge. Fan motor, propeller, drive shaft, bearings and drive components all swing out for easy access.
Applications
– Pulp & Paper Mills – Paint Room Exhaust – Automotive – Weld Smoke – Any application conducive to particulate build-up on
airstream fan components.
– Applications requiring routine washdown.
Features
Performance – Fan sizes 12" through 60"… perform­ance from 1,465 to 64,075 CFM at free air. See performance tables on pages 12 & 13; for performance at other operating points contact your Hartzell representative.
Construction – Same as Series 69 (see preceding page) with heavy-duty hinge mounting of fan motor, propeller & drive components. Standard unit construction is painted steel; aluminum or stainless steel construction available as an option.
Accessories – In addition to standard accessories (see pages 33 & 34), swingout fans are available with an optional wheeled support jack for ease of opening/ closing fan housing and De-Sta-Co clamps for ease of closing/opening swing out door.
Dimension Note – See dimensions table on page 11. Note that an additional 10" must be added to overall unit height for swingout construction.
Series 69S – Swingout Construction
(OPTIONAL ALUMINUM HOUSING SHOWN)
Page 11
11
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Dimensions
Standard Series 69
Series 69S
(Available Sizes 12"-60")
12 127⁄8 155⁄8 145⁄8 22 12 2 18 379⁄16 12
1
8 14
1
8 20 .064 145T
14 147⁄8 175⁄8 165⁄8 24 12 2 20 383⁄16 12
1
8 14
1
8 20 .064 145T
16 167⁄8 195⁄8 185⁄8 26 12 2 22 413⁄16 12
1
8 14
1
8 20 .064 182T
18 187⁄8 215⁄8 205⁄8 28 20 2 24 495⁄16 12
1
8 14
1
8 20 .064 213T
20 207⁄8 235⁄8 223⁄8 30 20 2 26 553⁄16 12
1
8 14
1
8 20 .064 213T
24 247⁄8 291⁄8 267⁄8 36 201⁄2 23⁄4 30 5713⁄16 10 .190 14
1
8 20 .064 215T
28 287⁄8 331⁄8 307⁄8 42 201⁄2 23⁄4 34 585⁄16 10 .190 14
1
8 20 .064 215T
30 307⁄8 351⁄8 33 42 201⁄2 23⁄4 36 615⁄16 10 .190 14
1
8 20 .064 215T
32 33 371⁄4 35 42 261⁄2 23⁄4 38 675⁄16 10 .190 14
1
8 20 .064 215T
36 37 413⁄8 39 48 261⁄2 23⁄4 44 675⁄16 10 .190 14
1
8 20 .064 215T
40 41 453⁄8 431⁄2 50 261⁄2 23⁄4 48 755⁄16 10 .190 14
1
8 20 .064 215T
42 427⁄8 471⁄4 45 54 261⁄2 23⁄4 50 761⁄16 10 .190 14
1
8 20 .064 215T
44 45 493⁄8 471⁄2 54 381⁄2 23⁄4 52 881⁄8 10 .190 14
1
8 16 .100 215T
48 491⁄8 531⁄2 515⁄8 60 381⁄2 33⁄4 56 891⁄8 10 .190 14
1
8 16 .100 215T
54 553⁄8 605⁄8 575⁄8 641⁄4 381⁄2 33⁄4 62 893⁄8 10 .190 14
1
8 16 .100 286T
60 613⁄8 665⁄8 635⁄8 701⁄4 381⁄2 33⁄4 68 897⁄8 10 .190 14
1
8 14 .100 286T
66 67 731⁄4 711⁄2 793⁄4 363⁄8 376
1
2 823⁄8 10
3
16
1
4
3
8 10 .190 326T
72 73 791⁄4 763⁄4 82 363⁄8 382
1
2 823⁄8 10
3
16
1
4
3
8 10 .190 326T
84 851⁄4 915⁄8 883⁄4 981⁄4 423⁄8 33⁄4 95 883⁄8 10
3
16
1
4
3
8 10 .190 326T
MOTOR
FRAMES
MAX
STEEL ALUM. STEEL ALUM. STEEL ALUM.
FAN
SIZE
Principal Dimensions – Series 69
Note: Specifications and dimensions are subject to change. Certified prints are available. Sizes 66"-84" units are supplied with a flat curb panel.
*For swing-out design, add 10". Not available for 66" thru 84".
ABCDEFGH*
JK L
AIRFLO
W
.
.
GA. MAT'L.
*
AIRFLO
W
GA MAT'L.
INSIDE
I.D.
B.C.
LIFTING LUGS STA ND A RD
GA.
MAT'L.
PIVOT POINT
SUPPORT JACK (OPTIONAL)
SQ.
INSIDE
Page 12
12
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Performance
Rating Table – Series 69 – Belt Drive Upblast Ventilation
Performance certified is for installation Type A: free inlet/free outlet. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Power ratings (BHP) include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
Blade
Motor
Peak Fan Fan
Size Model Code Angle HP RPM BHP RPM
A69---126-W---STFCE3
1
/3 1750 0.33 2315 1456 1314 1148
12" A69---126-W---STFCF3
1
/2 1750 0.50 2650 1667 1544 1411 1245
A69---126-W---STFCG3
3
/4 1750 0.75 3030 1906 1800 1687 1563 1410
A69---146-W---STFCE3
1
/3 1750 0.33 1980 2015 1848 1655
14" A69---146-W---STFCF3
1
/2 1750 0.50 2270 2310 2167 2008 1827 1599
A69---146-W---STFCG3
3
/4 1750 0.75 2595 2641 2517 2383 2237 2076
A69---166-W---STFCD3
1
/2 1750 0.50 2010 2918 2691 2479 2224
16" A69---166-W---STFCF3
3
/4 1750 0.75 2300 3339 3140 2948 2765 2522 A69---166-W---STFCH3 1 1750 1.11 2610 3789 3613 3441 3278 3115 A69---186-W---STFCF3
1
/2 1750 0.50 1590 3427 3208 2919 2522
18"
A69---186-W---STFCG3
3
/4 1750 0.75 1820 3923 3736 3513 3222 2859 A69---186-W---STFCH3 1 1750 1.10 2065 4451 4289 4106 3886 3616 A69---186-W---STFCI3 11/2 1750 1.65 2365 5097 4958 4805 4636 4437 A69---206-W---STFCD3
1
/2 1750 0.50 1355 3805 3505 3173
20"
A69---206-W---STFCF3
3
/4 1750 0.77 1555 4366 4105 3833 3521 3118 A69---206-W---STFCH3 1 1750 1.13 1765 4956 4726 4493 4241 3956 A69---206-W---STFCI3 11/2 1750 1.69 2020 5672 5471 5270 5062 4837 A69---246-W---STFCD3
1
/2 1750 0.48 1025 5302 4731 A69---246-W---STFCF3
3
/4 1750 0.75 1185 6130 5647 5091
24"
A69---246-W---STFCH3 1 1750 1.10 1345 6957 6539 6075 5526 4681 A69---246-W---STFCI3 11/2 1750 1.65 1540 7966 7605 7214 6791 6288 A69---246-W---STFCJ3 2 1750 2.22 1700 8794 8469 8123 7754 7353 A69---246-W---STFCK3 3 1750 3.39 1950 10087 9805 9511 9201 8876 A69---286-W---STFCG3
3
/4 1750 0.73 905 7782 6992 6295 A69---286-W---STFCH3 1 1750 1.10 1030 8857 8146 7534 6852 5953
28" A69---286-W---STFCI3 11/2 1750 1.70 1190 10232 9608 9052 8529 7919
A69---286-W---STFCJ3 2 1750 2.32 1320 11350 10782 10258 9789 9310 A69---286-W---STFCK3 3 1750 3.58 1525 13113 12615 12148 11716 11311 A69---306-W---STFCH3 1 1750 1.10 865 9131 8370 7543 A69---306-W---STFCI3 11/2 1750 1.65 990 10451 9792 9101 8277 7039
30" A69---306-W---STFCJ3 2 1750 2.20 1090 11506 10911 10289 9633 8717
A69---306-W---STFCK3 3 1750 3.32 1250 13195 12679 12144 11597 11013 A69---306-W---STFCL3 5 1750 5.62 1490 15729 15296 14857 14403 13945 A69---326-W---STFCH3 1 1750 1.11 785 10346 9428 8403 A69---326-W---STFCI3 11/2 1750 1.64 895 11796 10999 10144 9181
32" A69---326-W---STFCJ3 2 1750 2.19 985 12982 12262 11501 10676 9736
A69---326-W---STFCK3 3 1750 3.31 1130 14893 14269 13619 12940 12208 A69---326-W---STFCL3 5 1750 5.70 1355 17858 17340 16810 16262 15698 A69---366-W---STFCH3 1 1750 1.10 670 12289 11012 9509 A69---366-W---STFCI3 11/2 1750 1.65 765 14032 12940 11651 10353
36"
A69---366-W---STFCJ3 2 1750 2.18 840 15407 14423 13300 12084 10876 A69---366-W---STFCK3 3 1750 3.36 970 17792 16947 16038 15005 13955 A69---366-W---STFCL3 5 1750 5.82 1165 21369 20669 19946 19167 18311 A69---366-W---STFCM3 71/2 1750 7.45 1265 22558 21902 21209 20454 A69---406-W---STFCI3 11/2 1750 1.62 660 15507 14436 13202 A69---406-W---STFCJ3 2 1750 2.21 730 17152 16193 15129 13884 12290
40" A69---406-W---STFCK3 3 1750 3.43 845 19854 19034 18157 17192 16095
A69---406-W---STFCL3 5 1750 6.03 1020 23966 23289 22592 21852 21061 A69---406-W---STFCM3 71/2 1750 9.33 1180 27725 27140 26549 25934 25290 A69---426-W---STFCI3 11/2 1750 1.57 605 16494 15110 13620 A69---426-W---STFCJ3 2 1750 2.21 670 18266 17023 15711 14300
42"
A69---426-W---STFCK3 3 1750 3.45 775 21129 20059 18952 17788 A69---426-W---STFCL3 5 1750 5.97 930 25355 24463 23562 22630 21663 A69---426-W---STFCM3 71/2 1750 9.22 1075 29308 28534 27764 26975 26165 A69---426-W---STFCN3 10 1750 11.43 1155 31489 30767 30054 29325 28580 A69---446-W---STFCJ3 2 1750 2.19 655 20143 18818 17348 15589 A69---446-W---STFCK3 3 1750 3.42 760 23372 22240 21034 19702 18155
44" A69---446-W---STFCL3 5 1750 5.98 915 28138 27201 26240 25218 24123
A69---446-W---STFCM3 71/2 1750 9.29 1060 32598 31785 30974 30126 29238 A69---446-W---STFCN3 10 1750 10.96 1120 34443 33671 32909 32116 31290
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Page 13
13
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Rating Table – Series 69 – Belt Drive Upblast Ventilation (Cont’d.)
Fan Size
CFM 121416182024 2832364044485460667284
Minimum 1110 1490 1930 2425 2980 4255 5760 7490 9445 11630 14040 16680 21255 26170 30885 36755 50030 Maximum 2725 3670 4750 5975 7335 10475 14175 18435 23250 28630 34560 41055 52315 64410 76025 90480 123150
CFM Limitations for Damper Lids Operation Series 69
Minimum CFM to open lids Maximum CFM to prevent lid damage
Blade
Motor
Peak Fan Fan
Size Model Code Angle HP RPM BHP RPM
A69---486-W---STFCJ3 2 1750 2.16 585 22422 20506 18635 A69---486-W---STFCK3 3 1750 3.31 670 25680 23997 22358 20694 18653
48'' A69---486-W---STFCL3 5 1750 5.84 810 31046 29639 28280 26928 25572
A69---486-W---STFCM3 71⁄2 1750 8.99 935 35837 34603 33427 32249 31080 A69---486-W---STFCN3 10 1750 12.37 1040 39862 38740 37683 36624 35565 A69---543-L---STFCK3 3 1750 3.24 590 33447 29987 26925 23233 A69---543-L---STFCL3 5 1750 5.73 710 40250 37266 34698 32105 29043
54'' A69---543-L---STFCM3 71⁄2 1750 8.82 820 46486 43828 41527 39350 37084
A69---543-L---STFCN3 10 1750 11.86 905 51304 48843 46710 44719 42740 A69---543-L---STFCO3 15 1750 12.46 920 52155 49724 47622 45655 43711 A69---603-L---STFCL3 5 1750 5.60 595 45934 41950 38156 34237 30062
60''
A69---603-L---STFCM3 7
1
2 1750 8.63 685 52882 49344 46092 42750 39333 A69---603-L---STFCN3 10 1750 11.79 760 58672 55414 52504 49530 46492 A69---603-L---STFCO3 15 1750 15.36 830 64076 61024 58374 55676 52926 A69---664BA130STFCL3 13° 5 1750 4.55 650 45649 38488
66''
A69---664BA190STFCM3 19° 7
1
2 1750 7.69 650 56675 50911 42838 31254 A69---664BA220STFCN3 22° 10 1750 9.86 650 62048 56701 49245 34950 A69---664BA310STFCO3 31° 15 1750 15.75 650 71790 66057 58838 A69---724AA160STFCL3 16° 5 1750 4.36 584 54643 47850 A69---724AA160STFCM3 16° 71⁄2 1750 7.19 690 64561 59150 51379 40528
72'' A69---724AA190STFCN3 19° 10 1750 9.20 690 71910 66454 60183 49212 39191
A69---726AA250STFCO3 25° 15 1750 14.45 620 83603 79270 74138 67553 A69---726AA310STFCP3 31° 20 1750 19.65 620 87043 81395 74329 A69---844BA160STFCM3 16° 71⁄2 1750 7.23 500 81675 74956 67976 60485 A69---844BA220STFCN3 22° 10 1750 11.44 500 97242 91015 84133 76404 66999
84'' A69---844BA280STFCO3 28° 15 1750 16.76 500 110639 104313 97194 88955 78624
A69---846BA220STFCP3 22° 20 1750 21.56 546 116282 111959 107402 102569 97405 A69---846BA250STFCQ3 25° 25 1750 26.06 546 121895 116866 111692 106318
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Performance certified is for installation Type A: free inlet/free outlet. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Power ratings (BHP) include transmission losses. Performance ratings do not include the effects of appurtenances (accessories)
Page 14
14
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Upblast (Belt Drive) Smoke Ventilator
Series 69H
Hartzell Fan, Inc. originally pioneered the development of the first powered smoke ventilator. Today, the Hartzell Series 69H Upblast Smoke Ventilator meets or exceeds rigid I.R.I. (Industrial Risk Insurers) Guidelines for Heat and Smoke Venting, No. IM.2.1.4 (supersedes Guideline No. p.2.6).
An increasing number of insurance companies, local code bodies, and business and building owners are requiring these designated purpose ventilators to be installed, both in existing buildings and new structures.
The advantages of a properly designed powered smoke ventilator approach to the effective removal of hot gases and smoke include:
– the provision of early access into the building by firefighters. – reduce burden on the sprinkler system. – reduced risk of personal injury and property loss.
Installing roof mounted gravity vents alone may be inadequate. Variables such as inside and outside air temperature, wind velocity and location of sprinklers can seriously affect the performance of gravity vents. The Hartzell Series 69H Upblast Smoke Ventilator is pre-engineered and designed to be used as a high temperature powered roof ventilator. It is self-contained, ready to install, wire, and put into service. Moreover, the Series 69H is a multi-use product. It is designed to be used on a daily basis as a power roof ventilator (special independent electrical connections may be required), and as a gravity type roof ventilator in the event of a power failure. Other specific features and advantages of the Hartzell Series 69H follow.
Features:
Designed for continuous operation at 500°F exhaust air temperature, with ambient air drawn through belt tube.
Size 18" - 60"... performance from 3220 CFM to 64,035 CFM at free air.
Heavy gauge, all ferrous steel construction – includes Hartzell's tested and proven belt drive duct fan design with stack cap and curb panel for a complete vertical discharge roof ventilator. Stack cap lids open automatically when the unit is operating, close weather tight when the fan stops. On the inlet side of the smoke vent, a curved inlet orifice increases the efficiency and the performance of the ventilator. The curb panel provides a convenient method of curb mounting the smoke ventilator. The heavy gauge steel construction ensures the unit's ability to withstand high temperatures and provides a durable and rugged unit.
Welded steel propeller – three (3) bladed design with split taper bushing for easy removal from shaft. Reinforcements at the blade roots ensure stability and high stress characteristics. The welded steel propeller offers similar efficiency to the Hartzell cast aluminum lo-noise type propeller.
Open end, drip proof motors with 1.15 service factor. TEFC and other motor enclosures are available upon request.
Combination motor cover and belt guard – this standard feature provides weather protection and guards drive assembly. Cover is vented and removable.
Belt drive arrangement – motor is mounted exterior to the fan housing. Belts, bearings, pulleys and shaft are enclosed and protected from the air stream. The drive assembly is located on the negative side of the propeller; fan design provides for the draft of ambient air from outside the ventilator in and over the belts and bearings.
Belts – are heat resistant per I.R.I. standards. Drives feature two (2) belts minimum.
Bearings – regreasable roller bearing type, supplied with high temperature grease, designed for minimum four hours at 500°F. Copper bearing lubrication tubes are extended from the bearings through the belt tube to the exterior of the fan housing, allowing ease of maintenance.
Heat slinger – reduces heat conduction from the propeller to the shaft and helps draw air through the belt and bearing tube.
Heat sinks – Aluminum plates dissipate radiant heat between motor and duct housing, disconnect switch and mounting bracket, and bearings and bearing base.
Fusible link – spring operated, positive lid opener. When the temperature through the smoke vent exceeds 165°F, the fusible link allows the spring operated lid opener to lock the stack cap lids in the upright, open position. Provides gravity ventilation in case electricity to the power ventilator is interrupted.
Disconnect switch – non-fused, rain tight, NEMA 3R enclosure mounted on the curb panel and wired to the fan motor provides safety during maintenance.
Safety coating – standard finish is high temperature black enamel coating.
Accessories
Coatings – special coatings for corrosion resistance are available upon request.
Pre-fabricated roof curb – 18 gauge galvanized construction features full metal air stream liner. Available for flat, slope, or peaked roofs. Available in 8" or 12" height.
Guard – inlet guard is constructed of expanded metal and woven wire mesh. Outlet guard is spiral, ring type. (Can also be used as a bird screen.)
Hartzell Fan, Inc., certifies that the Series 69H Upblast (Belt Drive) Smoke Ventilator shown hereon is licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Sound performance data is available upon request. Please contact the factory and ask for Engineering Publication #SD-159.
Page 15
15
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
MOTOR
FAN FRAMES
SIZE ABCDEFGHJKLMNMAX.
18 187/8 215/8 205/8 28 221⁄16 224
515/16 12 GA 12 GA 20 GA 26 GA 25 213T
24 247/8 291/8 267/8 36 229⁄16 23/4 30 5913/16 10 GA 12 GA 20 GA 26 GA 31 215T
30 307/8 351/8 33 42 229⁄16 23/4 36 635/16 10 GA 12 GA 20 GA 26 GA 34 215T
36 37 413/8 39 48 289⁄16 23/4 44 695/16 10 GA 12 GA 20 GA 26 GA 34 215T
42 427/8 471/4 45 54 289⁄16 23/4 50 781/16 10 GA 12 GA 20 GA 26 GA 42 215T
48 491/8 531/2 515/8 60 411⁄8 33/4 56 915/8 10 GA 12 GA 16 GA 20 GA 42 215T
54 553/8 605/8 575/8 641/4 411⁄8 33/4 62 917/8 10 GA 12 GA 16 GA 20 GA 42 254T
60 613/8 665/8 635/8 701/4 411⁄8 33/4 68 923/8 10 GA 12 GA 14 GA 20 GA 42 254T
Dimensions
Principal Dimensions (Inches)
Note: Specifications and dimensions are subject to change. Certified prints are available.
AIRFLOW
M
GA.
G
INSIDE
GA.
L
HEAT DEFLECTOR
SHIELD
STANDARD
E
FUSIBLE LINK
STANDARD
HEAT SLINGER
STANDARD
H
N
HEAT SINK
(BRG. BLOCK)
STANDARD
J
GA.
LIFTING LUGS
STANDARD
K
GA.
I.D. OF DUCT FAN
A
C
B
SQ. INSIDE
D
B.C.
F
MOTOR COVER
STANDARD
Page 16
16
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Performance certified is for installation Type A: free inlet, free outlet. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Performance ratings do not include the effects of appurtenances (accessories). Power ratings (BHP) include transmission losses.
Performance
Rating Table – Series 69H
Motor
Peak Fan Fan
Size Model Code HP RPM BHP RPM
A69H--183-S---STFCF3
1
/2 1750 0.50 1730 3220 2925 2635
18"
A69H--183-S---STFCG3
3
/4 1750 0.75 1980 3685 3425 3175 2905 2490 A69H--183-S---STFCH3 1 1750 1.10 2250 4190 3960 3735 3515 3265 A69H--183-S---STFCI3 11/2 1750 1.64 2575 4795 4595 4395 4200 4010 A69H--243-S---STFCF3
1
/2 1750 0.49 950 5230 A69H--243-S---STFCG3
3
/4 1750 0.75 1095 6030 5285
24"
A69H--243-S---STFCH3 1 1750 1.10 1245 6855 6200 5525 A69H--243-S---STFCI3 11/2 1750 1.65 1425 7845 7275 6705 6015 A69H--243-S---STFCJ3 2 1750 2.20 1570 8645 8125 7610 7075 6160 A69H--243-S---STFCK3 3 1750 3.29 1795 9880 9430 8975 8525 8050 A69H--303-S---STFCH3 1 1750 1.09 830 7830 6705 A69H--303-S---STFCI3 11/2 1750 1.66 1020 9625 8730 7715
30" A69H--303-S---STFCJ3 2 1750 2.19 1120 10570 9755 8885 7670
A69H--303-S---STFCK3 3 1750 3.31 1285 12125 11420 10690 9875 8705 A69H--303-S---STFCL3 5 1750 5.51 1525 14390 13790 13195 12565 11885 A69H--363-S---STFCH3 1 1750 1.37 720 12300 10235 A69H--363-S---STFCI3 11/2 1750 1.79 830 14180 12335 10260
36"
A69H--363-S---STFCJ3 2 1750 2.20 910 15545 13835 12235 A69H--363-S---STFCK3 3 1750 3.28 1040 17765 16230 14900 13205 A69H--363-S---STFCL3 5 1750 5.49 1235 21100 19775 18595 17490 16115 A69H--363-S---STFCM3 71/2 1750 7.30 1360 23235 22025 20915 19915 18870 A69H--423-S---STFCI3 11/2 1750 1.41 555 16490 13650 A69H--423-S---STFCJ3 2 1750 2.35 645 19155 16725 14245
42"
A69H--423-S---STFCK3 3 1750 3.31 740 21975 19860 17750 15130 A69H--423-S---STFCL3 5 1750 5.46 875 25980 24180 22415 20645 18555 A69H--423-S---STFCM3 71/2 1750 8.22 1005 29845 28255 26725 25170 23650 A69H--423-S---STFCN3 10 1750 9.59 1060 31475 29965 28530 27055 25580 A69H--483-S---STFCJ3 2 1750 2.60 550 24205 20485 A69H--483-S---STFCK3 3 1750 3.31 630 27730 24420 21195
48" A69H--483-S---STFCL3 5 1750 5.46 745 32790 29930 27315 24395 19045
A69H--483-S---STFCM3 71/2 1750 8.23 855 37630 35080 32765 30495 27860 A69H--483-S---STFCN3 10 1750 10.47 930 40930 38570 36415 34355 32150 A69H--543-S---STFCK3 3 1750 3.31 490 32400 27960 23235 A69H--543-S---STFCL3 5 1750 5.56 600 39670 36005 32425 28445
54" A69H--543-S---STFCM3 71/2 1750 8.24 685 45290 42000 38940 35690 32150
A69H--543-S---STFCN3 10 1750 10.91 755 49920 46910 44130 41295 38285 A69H--543-S---STFCO3 15 1750 12.42 790 52235 49330 46685 43990 41135 A69H--603-S---STFCL3 5 1750 5.45 520 45615 42320 37000 31660
60"
A69H--603-S---STFCM3 7
1
/2 1750 8.37 600 52635 50015 46025 41130 36490 A69H--603-S---STFCN3 10 1750 10.82 655 57460 55230 51820 47395 43230 A69H--603-S---STFCO3 15 1750 14.70 730 64035 62250 59320 55845 51705
CFM @ SP
Free Air 1/8" 1/4" 3/8" 1/2"
Page 17
17
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Hooded Roof Ventilator
low-speed motors as in direct drive operations. Since the drive assembly is in the airstream, Series 16 ventilators are designed for clean air operation. Sizes 24" through 84", performance from 4,080 to 131,000 CFM at free air on intake; from 3,700 to 116,500 CFM at free air on exhaust. Also available as a Series 19I, 19E, or 19F, with motor out of the airstream. See drawing on next page.
SERIES 17 (Direct Drive) and 17B (Belted)
Truly reversible airfoil fans offer 100% air delivery for both intake and exhaust flows. Ratings vary slightly due to the difference in pressure drops in the intake and exhaust modes. This unit is ideal for applications where varying conditions call for intake (supply air) for some operations, and exhaust flow for others. Series 17 ventilators utilize the Hartzell reversible ring fan incorporating two curved orifice rings welded back-to-back with a reversible airfoil section propeller to provide efficient performance when operating in either direction. Sizes 18" through 72"… performance from 3,220 to 96,700 CFM at free air on intake; from 2,970 to 88,200 CFM at free air on exhaust.
Features:
Construction – ventilator hood and base are galvannealed steel, painted with an industrial air dry enamel coating to provide maximum protection from the elements. Aluminum construction is also available for “H” Duty only. The fan frame is painted mild steel. The hood is hinged on units through size 36". This allows for the hood to be rotated to the side or removed for access to the fan assembly. Sizes 42" through 84" feature split hoods which are removable for access to the fan. These larger sizes are available with Hartzell’s unique slide-rail access package to allow easy separation of the hood halves for inspection and maintenance (see page 22).
Standard construction on these units accommodates a 60 mph maximum wind load. Higher wind load construction features are available as an option.
All hoods, size 36" and larger, are shipped separately from the base and are to be mounted in the field. Lifting eyes and hardware required for securing the hood to the base are furnished as standard.
Motor Mount – “G” (General Industrial) Duty construction features an adjustable steel motor base and tubular steel frame, which are over-sized to provide structurally rugged construction. “G” Duty is available as Series 15I, 15E, 15F, 16I, 16E, and 16F in sizes 18" to 48" and will be limited by HP and RPM on certain sizes. Please reference the performance rating tables, the shaded models are those models offered as “G” Duty.
“H” (Heavy Industrial) Duty construction features solid rolled rod supports, welded to the fan panel and motor mounts to provide support for the motor. The steel motor base and solid steel support rods are oversized to provide structurally rugged construction. “H” Duty is available in all sizes and models.
Access Door – standard on all units.
Motors – totally enclosed fan cooled, foot mounted, T-frame motors are standard. Special motors are available upon request. See Motor Frame Size and Installation Weight Table for maximum motor frame sizes. Belted units, Series 16, are standard with adjustable motor slides for belt tightening.
Propellers – cast aluminum airfoil type. Several configurations are available to accommodate maximum flow for a given size and horsepower configuration. Typically, Hartzell 2, 3, 4 and 6 blade assemblies are used. They include the Hartzell Types N, P, L, W, A, AW and BA designs for standard flow. The Type R and Type AR blades are used for reversible type applications. Some designs are fixed pitch; others are adjustable pitch.
Series 15 (Direct Drive)
The hooded roof ventilator design provides complete protection from the elements for either exhaust or supply ventilation. The unit’s large hood surface reduces the air velocities through the ventilator. This feature minimizes pressure drop through the hood and eliminates the entrainment of rain into supply units. The fan assembly is placed in the upper section of the base, blades fac­ing down, with the motor, drives, etc. located above the fan assembly, for ease of maintenance.
The Hartzell hooded roof ventilators are designed with basic function in mind; they facilitate mounting of optional items. Hartzell has designed the Series 15 and 16 so that permanent or disposable filters may be added to the hood as an accessory item. Please refer to the separate rating table for filtered performance, beginning on page 23.
NOTE: This catalog incorporates merely a representative group of Hartzell blades that are available. Many other adjustable blades and blade angles can be furnished. Contact your Hartzell representative for additional informa­tion and assistance.
SERIES 15I (Intake) and 15E (Exhaust) – Direct Drive
An efficient, high performance ventilator. Best suited for applications where the unit is in a difficult location for servicing. Sizes 18" through 72", performance from 2,350 to 90,300 CFM at free air on intake; from 2,050 to 78,500 CFM at free air on exhaust.
SERIES 16I (Intake) and 16E (Exhaust) – Belted
Particularly suited for applications where noise is a factor. The belted arrangement prevents the necessity of using costly,
“G” Duty Shown
ABS Certificate
of Design Assessment
Received
Page 18
Max Motor Weight (less motor
Frame Size and options)
Fan
ABCDEFG
HJ
“G” “H”
Galv Alum
Size Galv Alum Galv Alum Duty Duty
18 221⁄4 301⁄4 441⁄4 341⁄4 595⁄8 311⁄2 123⁄4 14 GA. 0.090 18 GA. 0.063 56 56 212 93 24 281⁄4 361⁄4 537⁄8 405⁄8 72 381⁄8 153⁄4 14 GA. 0.090 18 GA. 0.063 145T 145T 305 134 30 351⁄4 431⁄4 555⁄8 451⁄8 80 381⁄8 171⁄2 14 GA. 0.090 18 GA. 0.063 184T 184T 370 163 36 421⁄4 501⁄4 577⁄8 505⁄8 90 381⁄8 193⁄4 14 GA. 0.090 18 GA. 0.063 213T 215T 448 196 42 481⁄4 561⁄4 645⁄8 541⁄8 96 435⁄8 21 14 GA. 0.090 18 GA. 0.063 215T 254T 560 246 48 541⁄4 621⁄4 721⁄2 675⁄8 120 461⁄4 261⁄4 14 GA. 0.090 18 GA. 0.063 254T 254T 947 374 54 601⁄4 681⁄4 773⁄8 787⁄8 140 463⁄4 305⁄8 14 GA. 0.090 18 GA. 0.063 -- 284T 1203 508 60 661⁄4 741⁄4 803⁄4 843⁄4 1505⁄8 473⁄4 33 14 GA. 0.090 18 GA. 0.063 -- 286T 1363 575 72 811⁄4 931⁄4 903⁄8 811⁄4 184 505⁄8 393⁄4 12 GA. 0.125 16 GA. 0.090 -- 286T 2339 1950 84 941⁄4 1061⁄4 903⁄8 941⁄4 200 505⁄8 393⁄4 12 GA. 0.125 16 GA. 0.090 -- 286T 3450 2800
FAN
CF
SIZE
24 633⁄8 477⁄8
30 671⁄8 495⁄8
36 743⁄8 545⁄8
42 915⁄8 705⁄8
48 967⁄8 705⁄8
54 1011⁄4 705⁄8
60 1035⁄8 705⁄8
72 1113⁄4 72
84 119
3
4 80
18
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
NOTE: The drawings show Series 15, direct drive, intake flow. Dimensions given below apply for Series 15, 16 and 17, direct or belt drive, intake, exhaust or reversible flow.
Principal Dimensions – Series 19I, 19E, 19F
4 3/8
4
6
3 1/2
13 1/2
BIRD SCREEN
OPTIONAL
LIFTING LUG FOR
LIFTING HOOD ONLY
POSITION
NOTE: HOOD IN OPEN ROTATED
HOLE IN GUSSET
FOR LIFTING BASE ONLY
OPTIONAL
DISCONNECT SWITCH
MOTOR LUBE TUBES
BELT GUARD
OPTIONAL GUARD
OPTIONAL SHUTTER
ACCESS DOOR
MAX.
G
D
E
SQUARE OUTSIDE
F
MAX.
MAX.
(REF.)
C
SQUARE INSIDE
SQUARE INSIDE
L
C
H
B
A
2 1/4
Dimensions
Sizes 18"– 36" Sizes 42"– 84"
Sizes 24"– 36" Sizes
42
"– 84"
NOTE: Dimensions and specifications are subject to change. Certified prints are available. Maximum installation weight less motor and any optional equipment. Additional hood dimension shown for filtered units.
Principal Dimensions – Series 15I, 15E, 15F, 16I, 16E, 16F, 17 and 17B
SQUARE OUTSIDE
E
4 3/8
(REF.)
C
OPTIONAL GUARD
G
2 1/4
F
OPTIONAL
MOTOR LUBE TUBES
OPTIONAL
DISCONNECT SWITCH
OPTIONAL SHUTTER
J
AIRFLOW
C
L
6
4
H
D
SQUARE INSIDE
A
SQUARE INSIDE
B
4
13 1/2
3 1/2
HOLE IN GUSSET
FOR LIFTING BASE ONLY
ACCESS DOOR
LIFTING LUG FOR
LIFTING HOOD ONLY
NOTE: HOOD IN OPEN ROTATED POSITION
OPTIONAL
BIRD SCREEN
SQUARE OUTSIDE
E
4 3/8
G
(REF.)
2 1/4
C
MOTOR LUBE TUBES
F
OPTIONAL GUARD
OPTIONAL
OPTIONAL
DISCONNECT SWITCH
OPTIONAL SHUTTER
C
L
H
J
AIRFLOW
6
4
D
A
B
SQUARE INSIDE
SQUARE INSIDE
13 1/2
3 1/2
HOLE IN GUSSET
FOR LIFTING BASE ONLY
ACCESS DOOR
LIFTING LUG FOR
LIFTING HOOD ONLY
OPTIONAL BIRD SCREEN
4 3/8
J
G
(REF.)
2 1/4
MAX.
C
F
MAX.
OPTIONAL
BEARING LUBE TUBES
BELT GUARD
DISCONNECT SWITCH
E
D
SQUARE OUTSIDE
LIFTING LUG FOR
LIFTING HOOD ONLY
OPTIONAL BIRD SCREEN
OPTIONAL GUARD
OPTIONAL SHUTTER
C
L
6
4
H
SQUARE INSIDE
A
SQUARE INSIDE
B
13 1/2
3 1/2
HOLE IN GUSSET
FOR LIFTING BASE ONLY
ACCESS DOOR
Page 19
19
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Performance
CFM @ SP – INTAKE
0" 1/8" 1/4" 3/8" 1/2"
Inst.
Wt. #
CFM @ SP – EXHAUST
0" 1/8" 1/4" 3/8" 1/2"
Rating Table – Series 15I or E – Direct Drive Hooded Ventilator
CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
Blade
Motor
Peak Fan
Size Model Code Angle HP RPM BHP
A_ _ _ _-182NA---STFCD3
1
4
1725 0.09 2350 1690 2050 1450 228
A_ _ _ _-188-Q---STFCD3
1
4
1725 0.28 3235 2940 2480 1900 1500 2950 2610 2160 1760 228
18" A_ _ _ _-183-L---STFCE3
1
3
1725 0.35 3510 3200 2855 1800 980 3175 2880 2420 1400 940 236
A_ _ _ _-184WB---STFCE3
1
3
1725 0.37 3845 3520 3220 3430 3170 236
A_ _ _ _-184WA---STFCF3
1
2
1725 0.55 4480 4170 3840 3375 3940 3660 234
A_ _ _ _-242NB---STFCF3
1
2
1725 0.56 6600 5810 4950 3350 5700 5050 4250 2850 327
A_ _ _ _-242NC---STFCG3
3
4
1725 0.86 7325 6700 6000 5000 6400 5800 5100 3400 331
A_ _ _ _-246PA---STFCH3 1 1750 1.07 8080 7670 7220 6770 6300 7280 6910 6550 6130 5550 335
24" A_ _ _ _-246PB---STFCI3 11⁄2
1750 1.50 9040 8670 8275 7830 7200 8175 7800 7340 6800 6150 340
A_ _ _ _-243-L---STFCE4
1
3
1140 0.34 5360 4750 4000 4860 4300 3150 329
A_ _ _ _-246PC---STFCF4
1
2
1140 0.52 6540 5950 5150 5810 5180 331
A_ _ _ _-243-L---STFCD5
1
4
870 0.14 4020 3070 3600 2600 334
A_ _ _ _-302-N---STFCI3 11⁄2
1750 1.55 14050 13000 12000 10800 9450 13100 12150 11150 10050 8775 405 A_ _ _ _-306PB---STFCK3 3 1750 2.30 13900 13200 12550 11800 10950 13325 12700 12000 11250 10500 434 A_ _ _ _-306PA---STFCL3 5 1725 4.90 19700 19175 18650 18200 17750 18900 18400 18000 17550 17050 448
30"
A_ _ _ _-306PB---STFCG4
3
4
1140 0.74 9280 8250 7120 5650 4200 8850 7900 6810 5400 4100 400 A_ _ _ _-303-L---STFCI4 11⁄2
1160 1.25 11425 10575 9650 8520 4980 10860 10050 9150 8000 4625 442 A_ _ _ _-304-W---STFCJ4 2 1160 1.75 13750 13000 12190 11275 13040 12300 11475 10575 453 A_ _ _ _-303-L---STFCF5
1
2
850 0.45 8350 7250 7950 6750 400
A_ _ _ _-306PA---STFCG5
3
4
870 0.65 10190 9050 7600 3875 3000 9700 8600 7010 3800 2950 405 A_ _ _ _-362ND---STFCH3 1 1750 1.08 14270 12500 10430 7900 12400 10870 8970 478 A_ _ _ _-362NC---STFCJ3 2 1750 2.00 17540 16200 14670 13120 11100 15280 14170 12880 11350 9600 483 A_ _ _ _-362NB---STFCK3 3 1750 2.82 20350 19100 17900 16800 15470 17700 16850 15850 14750 13500 520 A_ _ _ _-362NA---STFCH4 1 1160 1.12 15000 13500 11750 9250 13170 11870 10200 7450 483 A_ _ _ _-366PA---STFCI4 11⁄2
1160 1.40 15200 14070 12700 11100 9200 13600 12430 11150 9750 8200 520
36" A_ _ _ _-366PB---STFCK4 3 1160 2.43 18800 18000 16800 15500 14000 16800 15800 14750 13400 11200 531
A_ _ _ _-363-L---STFCJ4 2 1160 2.40 17910 17000 16050 15100 14000 16280 15500 14620 13650 12500 531 A_ _ _ _-364-W---STFCL4 5 1160 3.83 22350 21450 20600 19600 18500 19950 19100 18200 17050 15600 590 A_ _ _ _-363-L---STFCH5 1 870 1.03 13530 12350 11050 9350 12300 11250 10000 7500 520 A_ _ _ _-364-W---STFCI5 11⁄2
870 1.64 16850 15150 13800 11800 14900 13700 12200 531 A_ _ _ _-363-L---STFCF6
1
2
690 0.52 10730 9100 6800 5450 9700 8500 5550 483 A_ _ _ _-422NB---STFCJ4 2 1160 1.80 22000 19500 16900 12600 8300 19050 17000 14700 11400 7600 643 A_ _ _ _-422NA---STFCK4 3 1160 2.90 25850 23900 21600 19450 17000 22400 20750 19100 17200 13600 679 A_ _ _ _-426-P---STFCL4 5 1160 4.34 27600 26450 25300 24000 22300 25325 24200 23050 22800 20400 702
42"
A_ _ _ _-422NB---STFCH5 1 850 0.85 16800 13700 8900 3600 14575 11775 7400 3375 632 A_ _ _ _-422NA---STFCI5 11⁄2
850 1.25 19400 16700 13825 6600 3500 16900 14750 11950 6200 3200 643 A_ _ _ _-426-P---STFCJ5 2 850 1.87 20400 18750 17050 15100 12200 18650 17150 15550 11100 9400 679 A_ _ _ _-423-L---STFCK5 3 850 2.70 23300 21900 20400 18750 16800 21250 20000 18500 16900 15000 702 A_ _ _ _-426-P---STFCH6 1 690 0.95 16400 14250 11750 7700 5500 14850 2950 10500 7310 5400 643 A_ _ _ _-482NC---STFCJ4 2 1160 2.15 25970 23500 21000 17950 14400 23100 21000 18670 16000 12800 1030 A_ _ _ _-482NB---STFCK4 3 1160 3.12 29400 27100 24550 21650 18200 25900 23850 21600 19000 15600 1066 A_ _ _ _-482NA---STFCL4 5 1160 5.37 34850 33000 30950 28650 26000 30800 29050 27100 25000 22400 1089
48" A_ _ _ _-482NA---STFCJ5 2 870 2.18 25800 23300 20050 15750 22950 20330 17350 13150 1066
A_ _ _ _-482NA---STFCH6 1 690 1.12 20700 17300 11600 18300 15000 9400 1030 A_ _ _ _-483-L---STFCL5 5 870 4.45 31550 30000 28200 26400 24500 28600 27200 25600 23900 21800 1151 A_ _ _ _-484AA200STFCM4 20º 71⁄2
1160 8.48 41800 40300 38700 37000 35250 37070 35750 34250 32600 30800 1151 A_ _ _ _-542NA---STFCL4 5 1160 5.04 40300 38150 35250 32350 29000 35900 33650 31250 28700 25800 1345 A_ _ _ _-542NA---STFCJ5 2 870 2.13 30600 27000 22800 17300 27000 23800 20200 14600 1322 A_ _ _ _-542NC---STFCK5 3 870 3.13 34000 30900 27000 22300 30000 26900 23500 18400 1345
54" A_ _ _ _-543-L---STFCM5 71⁄2
870 8.40 46500 44700 42800 40900 39000 42000 40600 38900 37000 34800 1413 A_ _ _ _-546BA175STFCN5 17.5º 10 870 11.00 48700 46500 44200 40800 34000 42600 39900 36000 30800 26150 1493 A_ _ _ _-544BA140STFCK6 14º 3 690 3.35 32000 28650 20700 28400 23800 17200 1407 A_ _ _ _-546BA175STFCL6 17.5º 5 690 5.50 38700 35900 31600 21350 33800 29900 23400 18100 1413 A_ _ _ _-603-L---STFCO5 15 870 14.10 63800 61900 59700 57600 55300 57600 55900 54300 52500 49500 1678 A_ _ _ _-602BA150STFCL5 15º 5 870 5.57 46250 42700 38750 34100 27800 40800 37600 33900 29750 22000 1567 A_ _ _ _-604BA100STFCK6 10º 3 690 3.30 36150 32500 28500 22150 32650 29500 25300 19700 1567
60" A_ _ _ _-604BA165STFCL6 16.5º 5 690 5.45 45500 42400 39200 35500 27800 40900 38300 35000 30000 22800 1573
A_ _ _ _-604BA130STFCM5 13º 71⁄2
870 8.35 51000 48650 46300 43500 40000 46400 44200 41500 38500 34800 1573 A_ _ _ _-604BA165STFCN5 16.5º 10 870 10.90 57500 55000 52700 50100 47500 51700 49500 47350 44900 41500 1653 A_ _ _ _-606BA175STFCO5 17.5º 15 870 16.30 64250 62800 61100 59300 57100 59000 57100 55250 53100 50700 1678 A_ _ _ _-724AA140STFCN5 14º 10 870 10.90 75500 71000 65000 59000 51500 66000 61500 56000 50500 45500 2157 A_ _ _ _-724AA190STFCO5 19º 15 870 16.80 90300 87000 82000 77000 69000 78500 74000 68500 62500 56500 2204
72" A_ _ _ _-724AA140STFCL6 14º 5 690 5.45 60400 53600 45500 36600 28700 52300 46200 39700 32500 2109
A_ _ _ _-724AA190STFCM6 19º 71⁄2
690 8.40 71900 66200 60000 49000 39000 62000 56700 48800 41300 35000 2137 A_ _ _ _-724AA230STFCN6 23º 10 690 11.20 79900 74500 68600 60000 43300 68700 63300 54300 44700 38900 2157
Page 20
Blade
Motor
Peak Fan Fan
Size Model Code Angle HP RPM BHP RPM
A_ _ _ _-243-L---STFCD3
1
4
1750 0.27 960
4540 3800 2000 4110 3430 1700 900
333
24" A_ _ _ _-243-L---STFCE3
1
3 1750 0.36 1071
5070 4400 3400 4590 3980 2660 1520
340
A_ _ _ _-243-L---STFCF3
1
2 1750 0.54 1220
5770 5200 4530 3100 1700 5210 4700 4060 2500 1660
338
A_ _ _ _-303-L---STFCF3
1
2 1750 0.55 885
8600 7500 5850 2650 8200 7100 5300 2600
408
A_ _ _ _-303-L---STFCG3
3
4
1750 0.82 1010
9760 8820 7750 5900 3390 9300 8440 7320 5400 3290
412
30" A_ _ _ _-303-L---STFCH3 1 1750 1.10 1150
11325 10450 9550 8500 5200 10775 9900 9100 7900 4700
416
A_ _ _ _-303-L---STFCI3 11⁄2 1750 1.62 1340
12800 12100 11290 10470 9500 12160 11400 10600 9900 8750
421
A_ _ _ _-303-L---STFCJ3 2 1750 2.20 1480
14200 13510 12950 12100 11500 13600 12950 12350 11630 10860
421
A_ _ _ _-363-L---STFCF3
1
2 1750 0.56 666
10250 8700 4700 9360 7830 4250
485
A_ _ _ _-363-L---STFCG3
3
4
1750 0.82 764
11770 10400 8600 4100 10720 9430 7400 3950
489
36" A_ _ _ _-363-L---STFCH3 1 1750 1.10 837
12900 11680 10170 7200 4000 11750 10620 9100 5870 3900
493
A_ _ _ _-363-L---STFCI3 11⁄2 1750 1.70 980
15100 14100 12920 11480 8640 13740 12800 11600 9920 7200
498
A_ _ _ _-363-L---STFCJ3 2 1750 2.09 1050
16180 15240 14170 12960 11350 14730 13830 12810 11500 9350
498
A_ _ _ _-423-L---STFCH3 1 1750 1.10 595
15700 13580 9980 4200 2670 14400 12320 8520 4100 2770
613
A_ _ _ _-423-L---STFCI3 11⁄2 1750 1.65 703
18540 16580 14400 10550 5230 17800 15190 13130 9370 5150
618
42" A_ _ _ _-423-L---STFCJ3 2 1750 2.20 760
20200 18740 16780 13690 8750 18740 17100 15040 12100 8035
618
A_ _ _ _-423-L---STFCK3 3 1750 3.30 930
24400 22000 20500 19050 16500 22700 21200 19500 17300 16800
655
A_ _ _ _-423-L---STFCL3 5 1750 5.50 1100
28800 27100 26000 24500 21850 26600 25300 24000 22500 20800
666
A_ _ _ _-483-L---STFCH3 1 1750 1.08 525
19100 16200 11100 17200 14800 8900
1022
48"
A_ _ _ _-483-L---STFCJ3 2 1750 2.20 660
23730 21680 19300 15100 8600 21550 19700 17150 11800 8200
1027
A_ _ _ _-483-L---STFCK3 3 1750 3.00 740
26600 24750 22670 20340 15600 24070 22450 20470 17800 12800
1064
A_ _ _ _-483-L---STFCL3 5 1750 5.17 895
32260 30700 29100 27300 25530 29250 27950 26400 24730 22400
1075
A_ _ _ _-543-L---STFCJ3 2 1750 2.02 497
26400 23400 15400 23900 20900 12900
1296
A_ _ _ _-543-L---STFCK3 3 1750 3.03 573
30300 27800 24750 14300 27650 25150 20200 12800
1333
54"
A_ _ _ _-543-L---STFCL3 5 1750 5.05 671
35550 33500 31100 28000 18000 32450 30450 27750 22600 15400
1344
A_ _ _ _-543-L---STFCM3 71⁄2 1750 7.93 786
41650 39800 37850 35750 33200 37950 36300 34350 31800 27000
1380
A_ _ _ _-544AW220STFCL3 22° 5 1750 5.40 645
38900 36800 34500 31400 35150 33100 30000
1344
A_ _ _ _-544AW220STFCM3 22° 71⁄2 1750 8.10 737
44400 42700 41800 38500 35600 40300 38500 36500
1380
A_ _ _ _-603-L---STFCJ3 2 1750 2.29 437
31949 27952 21808 10464 30627 26862 18515 10335 6383
1485
A_ _ _ _-603-L---STFCK3 3 1750 3.14 496
36262 32773 28757 16274 11331 34762 31549 27371 16058 11173
1522
A_ _ _ _-603-L---STFCL3 5 1750 5.13 595
43500 40601 37600 34000 26260 41700 39100 36100 32298 21026
1533
60" A_ _ _ _-604AW220STFCM3 22° 71⁄2 1750 7.46 603
49532 46659 43823 40804 35407 47206 44721 42058 38853
1569
A_ _ _ _-604AW220STFCN3 22° 10 1750 10.00 665
54625 52003 49465 46812 43753 52060 49836 47420 44895 41429
1592
A_ _ _ _-604AW220STFCO3 22° 15 1750 14.85 761
62511 60204 57988 55734 53402 59575 57656 55574 53471 51198
1654
A_ _ _ _-606AW250STFCO3 25° 15 1750 14.52 683
62348 60771 59174 57583 55810 60299 58868 57319 55644 53548
1654
A_ _ _ _-724AA160STFCM3 16° 71⁄2 1750 7.70 690
66600 61000 53700 51500 34000 58000 52200 44700 37000
2444
72"
A_ _ _ _-726BA130STFCM3 13° 7
1
2 1750 8.00 531
61400 58000 54000 50000 46000 56500 53500 49700 46000 42300
2444
A_ _ _ _-726BA175STFCN3 17.5° 10 1750 11.20 531
70000 66700 63000 59000 55000 64000 61000 57500 54000 50000
2464
A_ _ _ _-726BA240STFCO3 24° 15 1750 16.80 531
84800 81600 77700 74000 70000 76000 73000 70000 66500 62500
2511
A_ _ _ _-844BA160STFCL3 16° 5 1750 5.83 455
76000 68500 60500 51500 67700 61500 54500 45000
3527
A_ _ _ _-844BA135STFCM3 13.5° 71⁄2 1750 8.10 546
83300 77000 70000 63300 55000 75000 69500 64000 57000 50000
3555
84"
A_ _ _ _-844BA210STFCN3 21° 10 1750 11.20 500
97300 90500 83700 76000 66000 85500 80000 74000 66000
3575
A_ _ _ _-846BA250STFCO3 25° 15 1750 16.00 455
108000 103000 96200 90000 83000 95700 90700 85700 85700
3622
A_ _ _ _-846BA250STFCP3 25° 20 1750 21.40 500
118700 114300 108000 102500 96000 105300 100500 96000 90500 84500
3642
A_ _ _ _-844BT222STFCQ3 22.2° 25 1750 27.50 500
122800 118000 113000 108000 102000 109000 105200 100000 95500 90000
3705
A_ _ _ _-846BN270STFCQ3 27° 25 1750 27.13 455
131000 126500 122000 117000 112000 116500 113000 108000 103500 98000
3705
20
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Rating Table – Series 16I or E – Belted Hooded Roof Ventilator
– Series 19I or E – Belt Drive Hooded Roof Ventilator
CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power ratings (BHP) include transmission losses.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
CFM @ SP – INTAKE
0" 1/8" 1/4" 3/8" 1/2"
Inst.
Wt. #
CFM @ SP – EXHAUST
0" 1/8" 1/4" 3/8" 1/2"
Page 21
21
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Rating Table – Series 17 – Direct Drive Hooded Reversible Roof Ventilator
Series 17B – Belted Hooded Reversible Roof Ventilator
CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power ratings (BHP) include transmission losses.
Blade
Motor
Peak Fan
Size Model Code Angle HP RPM BHP
18"
A_ _ _ _-186RB---STFCI2 1
1
2 3450 1.53 5185 5050 4900 4750 4610 4820 4700 4570 4430 4290 254
A_ _ _ _-186RA---STFCD3
1
4 1750 0.26 3220 2960 2650 2170 1690 2970 2710 2360 1975 1555 240
24"
A_ _ _ _-246RB---STFCH3 1 1750 1.25 7510 7110 6750 6400 6000 6850 6370 6240 5860 5440 358 A_ _ _ _-246RA---STFCI3 11⁄2 1750 1.73 8470 8150 7770 7400 6980 7750 7430 7100 6650 6170 363
30"
A_ _ _ _-306RA---STFCH4 1 1160 1.20 9650 9000 8400 7600 6650 9130 8550 7900 7150 6150 440 A_ _ _ _-306RB---STFCI4 11⁄2 1160 1.60 11350 10750 10150 9300 8400 10600 10050 9350 8600 7600 477 A_ _ _ _-362-R---STFCJ3 2 1750 1.92 16450 14770 13030 11430 9500 14120 12840 11600 10160 7900 528 A_ _ _ _-364-R---STFCH4 1 1140 1.09 13150 11600 10000 8150 11700 10450 9070 6940 528
36" A_ _ _ _-366RA---STFCJ4 2 1160 2.20 14800 14050 13140 12350 11800 13770 13000 12300 11790 11140 576
A_ _ _ _-366RB---STFCK4 3 1160 3.40 18250 17470 16750 16000 15100 16750 16150 15500 14750 13650 612 A_ _ _ _-366RA---STFCH5 1 870 1.20 11030 10050 9000 7880 6030 10260 9370 8470 7300 5520 565
42"
A_ _ _ _-426-R---STFCK5 3 870 3.50 22600 21350 20100 19050 17950 20900 19800 18900 17800 734 A_ _ _ _-426-R---STFCI6 11⁄2 690 1.75 17850 16300 14950 16500 15300 14000 734 A_ _ _ _-484AR200STFCL4 20° 5 1160 5.30 30900 29600 28300 27000 25600 28700 27400 26300 25000 23700 1154 A_ _ _ _-484AR235STFCM4 23.5° 71⁄2 1160 7.70 35700 34500 33300 32000 30700 32900 31800 30700 29600 28400 1216
48" A_ _ _ _-484AR160STFCI5 16° 11⁄2 870 1.65 18230 16750 15000 13250 10500 17200 15750 14200 12400 1095
A_ _ _ _-484AR220STFCK5 22° 3 870 3.10 25200 23600 21900 20000 17550 23300 21800 20250 17400 15700 1154 A_ _ _ _-486AR220STFCJ6 22° 2 690 2.30 21500 19900 18200 16250 13200 20100 18700 17100 15000 11800 1154 A_ _ _ _-544AR170STFCK5 17° 3 870 3.20 27900 26000 23900 21800 19700 26000 24300 22600 20600 18400 1420 A_ _ _ _-544AR220STFCL5 22° 5 870 5.30 36000 34200 32200 30000 27800 33100 31600 29700 27800 25500 1482
54" A_ _ _ _-546AR250STFCM5 25° 71⁄2 870 8.10 43300 41800 40300 38600 37000 40000 38600 37300 35800 34300 1488
A_ _ _ _-546AR280STFCN5 28° 10 870 10.90 48100 46500 45100 43500 41700 44100 42600 41200 39700 38200 1568 A_ _ _ _-546AR220STFCK6 22° 3 690 3.40 30800 28900 27000 25000 22700 28800 27300 25500 23300 1482 A_ _ _ _-604AR180STFCL5 18° 5 870 5.60 40600 38400 36400 34600 32000 37900 36000 34100 32600 30000 1657 A_ _ _ _-604AR220STFCM5 22° 71⁄2 870 8.60 49400 47400 45200 43500 40700 45600 43800 41900 40300 37700 1663
60"
A_ _ _ _-604AR250STFCN5 25° 10 870 11.65 55600 53700 51700 49900 47300 51000 49000 47300 45900 43500 1743 A_ _ _ _-606AR28-STFCO5 28° 15 870 17.20 66100 64600 62900 61200 59500 60700 59100 57600 55800 1768 A_ _ _ _-604AR160STFCJ6 16° 2 690 2.35 29400 25900 23200 20000 26800 24500 22000 19000 1595 A_ _ _ _-604AR190STFCK6 19° 3 690 3.45 34200 31400 28700 25800 22000 31700 29300 26800 24000 1657 A_ _ _ _-724AR160STFCN5 16° 10 870 10.60 62200 59600 57200 54800 52400 58400 56200 54000 51800 49500 2304 A_ _ _ _-724AR225STFCP5 22.5° 20 870 21.70 87400 85000 82600 80200 77700 80500 78300 76200 73800 71600 2371
72" A_ _ _ _-724AR250STFCQ5 25° 25 870 27.70 96700 94000 91700 89300 86600 88200 86000 83800 81600 79400 2434
A_ _ _ _-724AR220STFCN6 22° 10 690 10.90 67700 64500 61400 58000 54500 62500 59800 56600 53500 50200 2304 A_ _ _ _-724AR260STFCO6 26° 15 690 16.00 78200 75200 72300 69000 66000 71800 69000 66400 63500 60300 1929
CFM @ SP – INTAKE
0" 1/8" 1/4" 3/8" 1/2"
Inst.
Wt. #
CFM @ SP – EXHAUST
0" 1/8" 1/4" 3/8" 1/2"
Page 22
22
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Optional Filtered Hooded Ventilator
The Hartzell Series 15F (direct drive) and 16F (belted) hooded roof ventilators are available with an optional filter rack, designed to accept standard sized filters. Permanent, washable filters and disposable filters are both available. This optional filter rack must be installed at the factory. As described on Page 18, the ventilator hood on sizes 18" through 36" is one piece. On size 42" through 84", the ventilator hood is in two pieces. Filters are accessible by removing retainer clips in the filter rack for ease of filter installation and maintenance.
When you specify the filter option, other options and features are still available, including the slide rail package for split ventilator heads shown in the illustration above.
On the pages that follow, actual filtered supply performance ratings are provided for both the Series 15F and 16F hooded ventilators.
Features:
Sizes – Series 15F – Direct Drive – size 18" through 72" performance from 1,375 to 88,000 CFM at free air.
Series 16F – Belted and Series 19F – Belt Drive – size 24" through 84"… performance from 3,990 to 128,000 CFM at free air.
Construction and Dimensions – are identical to the standard Series 15F and 16F units. Please refer to Pages 17 and 18, “G” (General Industrial) Duty and “H” (Heavy Industrial) Duty construction available. Refer to Rating Tables on Pages 23 and 24. The filter rack adds an additional 2
1
4" to the overall vertical dimension of the ventilator hood, but does not increase the overall unit height.
Filters – permanent, washable filters are provided as standard and the performance ratings that follow are based on losses through permanent filters. Resistance through disposable filters tends to be higher. Please refer to the resistance curve for disposable filters on this page. Use of disposable filters will cause the fan performance to change.
Other Options and Accessories – are available. Please see Pages 33 and 34.
Series 15F, Size 30", with
permanent filters
Series 15F, Size 42", with permanent
filters and optional slide rail package
ABS Certificate
of Design Assessment
Received
HOODED VENTILATOR RESISTANCE CURVES (VEL. VS. S.P.)
1 .900
.800
.700
.600
.500
.400
.300
.250
.200
.150
(1) DISPOSABLE FILTERS (2) PERMANENT FILTERS (3) DAMPER
(1)
(2)
(3)
.100 .090
S.P. (IN. W.G.)
.080
.070
.060
.050
.040
.030
.025
.020
.015
.010
VELOCITY (FPM X 100)
CFM
VELOCITY =
AREA (SQ. FT.)
FILTER
HOOD NET FREE AREA
SIZE
13.9
18
24.8
24
29.4
30
32.2
36
34.2
42
62.5
48
91.0
54
105.6
60
148.4
72
213.5
84
AREA
23.6
27.6
31.6
33.2
60.0
86.0
101.2
143.8
176.0
DAMPER
AREA
2.5
7.2
4.34
7.11
10.56
14.06
18.06
22.56
27.56
42.25
57.5
32.521.5198765432.521.51
Page 23
Blade
Motor
Peak Fan
Size Model Code Angle HP RPM BHP
A15F_-188-Q---STFCD3
1
/4 1725 0.28 3175 2870 2400 1860 1490 256
A15F_-183-L---STFCE3
1
/3 1725 0.34 3430 3145 2765 1660 1175 264
18" A15F_-184WB---STFCE3
1
/3 1725 0.37 3730 3430 3115 264
A15F_-184WA---STFCF3
1
/2 1725 0.55 4340 4090 3710 262
A15F_-184WA---STFCD4
1
/4 1140 0.16 2790 2410 257
A15F_-242NM---STFCF3
1
/2 1725 0.56 6700 5630 4770 3100 377
A15F_-242NC---STFCG3
3
/4 1725 0.79 7130 6475 5760 381
24"
A15F_-246PA---STFCH3 1 1750 1.13 7870 7470 7030 6580 6110 385 A15F_-246PB---STFCI3 11/2 1750 1.50 8820 8450 8070 7580 6990 390 A15F_-243-L---STFCE4
1
/3 1140 0.33 5230 4640 3860 379
A15F_-246PC---STFCF4
1
/2 1140 0.52 6350 5770 4940 381 A15F_-302-N---STFCI3 11/2 1750 1.60 13525 12575 11550 10400 9100 463 A15F_-306PB---STFCJ3 2 1750 2.10 13600 12925 12250 11575 10700 463 A15F_-306PA---STFCL3 5 1750 5.25 17800 17275 16800 16200 15600 506 A15F_-306PB---STFCG4
3
/4 1140 0.71 9080 8100 6990 5520 4150 458
30" A15F_-303-L---STFCH4 1 1160 1.15 11025 10175 9300 8200 459
A15F_-303-L---STFCI4 11/2 1160 1.20 11125 10300 9400 8300 4800 500 A15F_-304-W---STFCJ4 2 1160 1.75 13360 12600 11790 10875 511 A15F_-302-N---STFCD5
1
/4 850 0.18 6520 4200 457 A15F_-306PA---STFCF5
1
/2 850 0.48 8650 7500 4350 2875 2050 458 A15F_-366PA---STFCI4 11/2 1160 1.40 14700 13600 12200 10750 8800 586 A15F_-366PB---STFCJ4 2 1160 2.42 18400 17400 16200 15000 13200 597
36" A15F_-364-W---STFCL4 5 1160 3.85 21700 20900 20000 19000 17900 656
A15F_-363-L---STFCH5 1 870 1.03 13250 12100 10800 8800 586 A15F_-364-W---STFCI5 11/2 870 1.64 16350 15150 13750 11650 597 A15F_-422NB---STFCJ4 2 1160 1.80 19850 17700 15400 12050 7700 714 A15F_-422NA---STFCK4 3 1160 2.92 23250 21425 19650 17825 14450 750 A15F_-426-P---STFCL4 5 1160 4.60 25850 24800 23600 22350 20900 773
42" A15F_-422NA---STFCI5 11/2 850 1.25 17450 15225 12400 6300 3250 714
A15F_-426-P---STFCJ5 2 850 1.82 19100 17600 15950 14000 10800 750 A15F_-423-L---STFCK5 3 850 2.68 21850 20450 19000 17400 15400 844 A15F_-426-P---STFCH6 1 690 1.00 15325 13300 10725 7400 5400 714 A15F_-482NA---STFCL4 5 1160 5.37 33800 32000 29900 27700 25000 1216 A15F_-482NA---STFCJ5 2 870 2.19 25150 22700 19400 15000 1193
48"
A15F_-482NA---STFCH6 1 690 1.12 20150 16550 10800 1157 A15F_-484AA190STFCI6 19° 11/2 690 1.63 23400 20800 17300 1193 A15F_-484AA190STFCK5 19° 3 870 3.26 29500 27500 25200 22300 1216 A15F_-484AA200STFCM4 20° 71/2 1160 8.48 41200 39000 37500 35800 34000 1278 A15F_-542NA---STFCL4 5 1160 5.04 39500 36900 34200 31300 28200 1508 A15F_-542NA---STFCJ5 2 870 2.13 29700 26200 22200 16700 1485
54" A15F_-542NC---STFCK5 3 870 3.15 33000 29800 26000 21400 1508
A15F_-543-L---STFCM5 71/2 870 8.30 45250 43500 41600 39900 38000 1576 A15F_-546BA175STFCN5 17.5° 10 870 11.00 47200 45000 42500 38500 30800 1656 A15F_-604BA100STFCK6 10° 3 690 3.31 35500 31900 28000 21500 1740 A15F_-602BA150STFCL5 15° 5 870 5.57 44900 41300 37500 32700 26100 1740
60" A15F_-604BA130STFCM5 13° 71/2 870 8.40 49750 47500 45100 42200 38800 1746
A15F_-604BA165STFCN5 16.5° 10 870 10.90 55900 53600 51300 48800 46100 1826 A15F_-606BA175STFCO5 17.5° 15 870 16.30 63000 61400 59800 57800 55500 1851 A15F_-724AA140STFCN5 14° 10 870 11.00 73200 68500 63000 57000 50000 2443 A15F_-724AA190STFCO5 19° 15 870 16.80 88000 84000 79000 73300 65500 2490
72" A15F_-724AA140STFCL6 14° 5 690 5.50 58700 52000 44000 35300 2395
A15F_-724AA190STFCM6 19° 71/2 690 8.40 69700 63800 57500 46600 37500 2423 A15F_-724AA230STFCN6 23° 10 690 11.20 77300 72000 66000 54000 42000 2443
23
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Performance
Rating Table – Series 15F – Filtered Hooded Ventilator – Direct Drive
Performance certified includes resistance through filters. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Net Inst.
Wt. #
Page 24
24
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Rating Table – Series 16F – Filtered Hooded Ventilator – Belted
Series 19F – Filtered Hooded Ventilator – Belt Drive
Performance certified includes resistance through filters. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75 Power ratings (BHP) include transmission losses.
“G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models.
Blade
Motor
Peak Fan Fan
Size Model Code Angle HP RPM BHP RPM
A_ _ _ _-243-L---STFCD3
1
4 1750 0.18 862 3990 3100 383
24"
A_ _ _ _-243-L---STFCD3
1
4 1750 0.27 960 4420 3660 1990 383
A_ _ _ _-243-L---STFCE3
1
3 1750 0.36 1071 4940 4270 3170 390
A_ _ _ _-243-L---STFCF3
1
2 1750 0.54 1220 5610 5030 4380 2900 388
A_ _ _ _-303-L---STFCF3
1
2 1750 0.55 900 8520 7450 5750 2500 466
A_ _ _ _-303-L---STFCG3
3
4 1750 0.82 1030 9710 8820 7680 5710 3330 470
30" A_ _ _ _-303-L---STFCH3 1 1750 1.10 1150 11025 10175 9300 8200 4900 474
A_ _ _ _-303-L---STFCI3 11⁄2 1750 1.62 1340 12460 11840 11070 10250 9330 479 A_ _ _ _-303-L---STFCJ3 2 1750 2.20 1480 15300 14800 12700 11890 10750 479 A_ _ _ _-363-L---STFCF3
1
2 1750 0.56 666 10050 8500 4650 551
A_ _ _ _-363-L---STFCG3
3
4 1750 0.81 764 11550 10200 8450 4100 555
36" A_ _ _ _-363-L---STFCH3 1 1750 1.10 837 12630 11470 9950 6850 4000 559
A_ _ _ _-363-L---STFCI3 11⁄2 1750 1.70 980 14770 13800 12670 11200 8300 630 A_ _ _ _-363-L---STFCJ3 2 1750 2.08 1050 15820 14900 13900 12700 10950 630 A_ _ _ _-423-L---STFCH3 1 1750 1.10 595 14920 12600 8740 4100 2020 684 A_ _ _ _-423-L---STFCI3 11⁄2 1750 1.65 725 18220 16650 14700 11740 7640 689
42" A_ _ _ _-423-L---STFCJ3 2 1750 2.20 815 20400 19100 17700 16090 13650 689
A_ _ _ _-423-L---STFCK3 3 1750 3.30 930 23200 21700 20000 17850 17350 726 A_ _ _ _-423-L---STFCL3 5 1750 5.50 1100 27100 26000 23500 22900 21400 737 A_ _ _ _-483-L---STFCH3 1 1750 1.08 525 18700 16000 10600 1149
48"
A_ _ _ _-483-L---STFCJ3 2 1750 2.07 660 23250 21200 18900 14800 1154 A_ _ _ _-483-L---STFCK3 3 1750 3.00 740 26000 24200 22200 19750 15200 1191 A_ _ _ _-483-L---STFCL3 5 1750 5.10 895 31500 30000 28400 26800 24800 1202 A_ _ _ _-543-L---STFCJ3 2 1750 2.01 497 25750 23800 14800 1459 A_ _ _ _-543-L---STFCK3 3 1750 3.00 573 29650 27150 23700 13800 1496
54"
A_ _ _ _-543-L---STFCL3 5 1750 5.03 671 34700 32700 30250 26800 17000 1507 A_ _ _ _-543-L---STFCM3 71⁄2 1750 7.88 786 40650 38900 36950 34800 31800 1543 A_ _ _ _-544AW220STFCL3 22° 5 1750 5.30 645 38000 36000 33500 1507 A_ _ _ _-544AW220STFCM3 22° 71⁄2 1750 8.07 737 43400 41600 39700 37300 1543 A_ _ _ _-603-L---STFCJ3 2 1750 2.00 437 30600 26700 21200 1658 A_ _ _ _-603-L---STFCL3 5 1750 5.15 595 41500 38800 35750 32000 24900 1706 A_ _ _ _-603-L---STFCM3 71⁄2 1750 7.50 672 46900 44500 41800 38800 35200 1741
60"
A_ _ _ _-603-L---STFCO3 15 1750 14.95 858 60000 58050 56000 53900 51800 1827 A_ _ _ _-604AW250STFCK3 25° 3 1750 2.95 436 36600 32800 26600 1695 A_ _ _ _-604AW250STFCM3 25° 71⁄2 1750 7.86 603 50400 48000 45200 41600 32000 1742 A_ _ _ _-604AW250STFCN3 25° 10 1750 10.60 665 55600 53500 51100 48200 44400 1765 A_ _ _ _-604AW250STFCO3 25° 15 1750 15.80 761 63600 61700 59800 57400 55000 1737 A_ _ _ _-724AA220STFCL3 22° 5 1750 5.50 531 60500 53500 38000 2694 A_ _ _ _-724AA160STFCM3 16° 71⁄2 1750 7.70 690 64800 59000 52000 42000 33000 2730
72"
A_ _ _ _-724AA200STFCN3 20° 10 1750 11.00 690 74000 69000 62000 52000 41300 2750 A_ _ _ _-726BA215STFCO3 21.5° 15 1750 16.50 690 85000 80500 76500 70500 61500 2797 A_ _ _ _-726BA250STFCP3 25° 20 1750 21.50 690 93300 88700 85000 80000 2800 A_ _ _ _-726BA235STFCQ3 23.5° 25 1750 27.70 637 98000 95000 92500 89500 86500 2880 A_ _ _ _-844BA160STFCL3 16° 5 1750 5.83 455 74300 67000 59500 50700 3877 A_ _ _ _-844BA250STFCN3 25° 10 1750 11.00 455 93800 87000 79500 70000 3925 A_ _ _ _-844BA170STFCM3 17° 71⁄2 1750 8.25 500 84000 77700 70700 63500 54000 3905
84"
A_ _ _ _-844BA265STFCO3 26.5° 15 1750 16.20 500 106300 100000 93500 85700 76000 3972 A_ _ _ _-844BA270STFCP3 27° 20 1750 21.80 546 118000 112000 106000 99300 91300 3992 A_ _ _ _-846BA280STFCR3 28° 30 1750 33.00 546 135500 130000 125500 121000 115000 4097 A_ _ _ _-844BA290STFCP3 29° 20 1750 21.73 455 124500 118400 112500 106000 98000 3992 A_ _ _ _-846BN270STFCQ3 27° 25 1750 26.92 455 128000 124000 119000 114500 109500 4072
CFM @ SP
0" 1/8" 1/4" 3/8" 1/2"
Net Inst.
Wt. #
Page 25
MATERIAL
NOM.
GAUGE
SIZE
BCDD1D
2
FGH
HEAD BASE
28 413/4 331/4 181/2 28 34 207/8 66 34 20 14 32 441/2 361/4 181/2 28 34 231/2 72 37 20 14 36 503/4 421/4 181/2 28 34 263/4 84 43 20 14 44 601/4 513/4 213/4 28 34 325/8 103 521/2 18 14 48 65 561/2 231/2 28 34 351/2 112 571/2 18 14 54 731/4 641/2 253/8 28 34 40 126 651/2 18 14 60 79
1
/4 701/2 29 28 37 455/8 143 713/4 18 14
25
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Features
Construction – galvanized steel base and hood; painted steel orifice panel and fan frame. The hood is hinged to swing back for easy access to the fan assembly. The airflow splitter in the hood allows for the same high efficiency in either direction. The aerodynamically designed hood provides a compact, low profile. Hooded ventilators are also available in painted steel and aluminum construction.
Motors – belted units (Series 73J) feature close-coupled drive and totally enclosed fan cooled motors. Direct drive units (Series 71J and 75J) feature totally enclosed air over motors.
Propellers – cast aluminum and airfoil type.
Options and Accessories
Shutters – automatic, motor, or manually operated shutters can be mounted in either the throat of the unit or below the roof line.
Access Door – hinged door with quick release latches for access to the interior of the hoodjet.
Bird Screen – half-inch square opening wire mesh, constructed of either galvanized steel or aluminum.
Disconnect Switch – NEMA watertight enclosure available as an option.
Hoodjet Ventilator
Series 71 J (Direct Drive)
Series 73J (Belted)
Series 75J (Reversible)
Extended Lube Tubes – will be provided from the motor on direct drive units and from the bearings and motor on belt drive and belted units to the exterior of the housing only when the motor is designed for external lubrication fittings (relubricable versus sealed motor bearings).
Hartzell Hoodjet Ventilators are available in three styles: (1) air intake; (2) air exhaust; (3) reversible…combination intake and exhaust.
Direct Drive – Series 71J
An efficient, high performance ventilator, best suited for applications where the unit is in a difficult location for servicing and maintenance.
Sizes: 28" – 60" Performance from 5,480 to 36,500 CFM at free air intake; from 5,480 to 60,600 CFM at free air exhaust.
Propellers: 28" – 60" 2-blade, Type N
28" – 60" 3-blade, Type L 28" – 44" 4-blade, Type W 28" – 44" 6-blade, Type P 48" – 60" 4-blade and 6-blade adjustable, Type A
Belted – Series 73J
The Series 73J is close-coupled, belt driven, with the motor in the airstream. This ventilator utilizes Hartzell’s exclusive "L" propeller which is designed to provide high volume airflow at low tip speeds and relatively low noise levels.
Drive shafts are ground and polished, keyed at both ends. Bearings are heavy duty, self-aligning, deep-row, radial ball type, shielded and mechanically sealed in cast iron or malleable housing; relubricable type for continuous service. Belts are oil, heat and static resistant type, over-sized for continuous duty.
Sizes: 28" – 60" Performance from 5,870 to 40,550 CFM at free air on intake; from 5,870 to 51,000 CFM at free air exhaust.
Propellers: 28" – 60" 3 blade lo-noise, Type L.
Reversible – Direct Drive – Series 75J
An ideal unit for applications where varying conditions may call for intake during some periods and exhaust during others. The Series 75J ventilator utilizes the Hartzell reversible ring fan incorporating two-curved orifice rings welded back-to-back with a fully reversible airfoil section propeller to provide the same efficient performance when operating in either direction.
Sizes: 28" – 60" Performance from 6,800 to 44,700 CFM at free air.
Propellers: 28" – 60" 2-, 4-, and 6-blade reversible, Type R.
Principal Dimensions – Series 71J, 73J and 75J
Specifications and dimensions are subject to change. Certified prints are available.
NOTES:
1. *“D” dimension is for all ventilators without shutters in throat, and for exhaust vents with throat mounted auto or manual shutters.
2. *“D1” dimension is for intake or exhaust vents using motor operated shutters.
3. *“D2” dimension is for reversible vents using motor operated shutters.
4. Stutters are optional, and must be specified on order along with locations.
5. With “B” or “C” type bases, the “G” dimension may be lengthwise (L) – perpendicular to slope or slopewise (S) parallel to slope. If slope exceeds 6 inches per foot, the “G” dimension must be perpendicular (“L” type) to the slope when using “B” base.
6. When using either “B” or “C” base, the direction of the “G” dimension must be specified as “BS”, “BL”, “CS” or “CL”.
7. Lube tubes extended to the outside of the base is optional.
BIRD SCREEN OPTIONAL
INTAKE EXHAUST
AIRFLOWAIRFLOW
AIRFLOW AIRFLOW
G
AIRFLOW
REVERSIBLE
AIRFLOW
LATCH CHAIN
H
F
ANCHOR STRAPS (4) FURNISHED ON 36 INCH SIZE AND LARGER
SHUTTERS
*
D OR D1
ROOF
STANDARD SHUTTER LOCATION LOCATION (TYPICAL)
OPTIONAL THROAT MOUNTED SHUTTER LOCATION. INCLUDES ACCESS DOOR
SHUTTERS
ROOF
*
D
* D OR D2
4
SHUTTERS
MAXIMUM CURB
4
5
TYPE "B", SLOPE BASE
= SLOPE
M
12 12
TYPE "A" (CURB BASE)
C
B
INSIDE VENT CURB
TYPICAL
D MINIMUM
CUSTOMER TO SUPPLY
SLOPE IN INCHES PER FOOT
HINGE
M
TYPE "C", PEAK BASE
5
Page 26
Max.
CFM @ SP
Size Model Code HP BHP RPM 0" 1/8" 1/4"
A75J--282-R---STFCF31⁄2 0.55 1725 6800 5750 4600
28" A75J--284-R---STFCH3 1 1.10 1750 8450 7750 7130
A75J--284-R---STFCE41⁄3 0.32 1140 5570 4560 2790 A75J--362-R---STFCJ3 2 1.90 1750 14480 13050 11730
36"
A75J--364-R---STFCH4 1 1.10 1160 11870 10580 9200 A75J--366-R---STFCK4 3 3.20 1160 18000 16300 15650 A75J--362-R---STFCF41⁄2 0.60 1140 9600 7570 4400 A75J--446-R---STFCL4 6 5.60 1160 26400 25300 24000
44" A75J--446-R---STFCJ5 2 2.30 870 19800 18150 16470
A75J--446-R---STFCH6 1 1.20 690 15400 13430 11770
44" A75J--482-R---STFCK4 3 3.40 1160 25670 23200 20700 54" A75J--542-R---STFCK4 3 2.90 1160 29200 26800 24000
A75J--602-R---STFCM4 71⁄2 6.50 1160 37000 34300 31500
60" A75J--602-R---STFCN4 10 9.40 1160 44700 42100 39500
A75J--602-R---STFCL5 5 3.90 870 33550 30050 26000
Max.
CFM @ SP
Size Model Code HP BHP RPM 0" 1/8" 1/4"
A73J--283-L---STFCE31⁄3 0.36 883 5870 5010 2800
28" A73J--283-L---STFCF31⁄2 0.54 1035 6870 6160 5200
A73J--283-L---STFCG33⁄4 0.74 1165 7750 7130 6430 A73J--323-L---STFCF31⁄2 0.53 825 8100 7050 4500 A73J--323-L---STFCG33⁄4 0.76 945 9270 8360 7200
32" A73J--323-L---STFCH3 1 1.00 1045 10280 9460 8510
A73J--323-L---STFCI3 11⁄2 1.50 1190 11690 10980 10190 A73J--323-L---STFCJ3 2 1.90 1305 12820 12170 11490 A73J--363-L---STFCF31⁄2 0.57 666 9520 8000 4470 A73J--363-L---STFCG33⁄4 0.81 764 10900 9600 7640
36" A73J--363-L---STFCH3 1 1.10 837 11930 10820 9300
A73J--363-L---STFCI3 11⁄2 1.70 980 14000 13030 11880 A73J--363-L---STFCJ3 2 2.00 1050 15000 14090 13100 A73J--443-L---STFCI3 11⁄2 1.50 680 18800 17000 14850
44"
A73J--443-L---STFCJ3 2 1.90 738 20400 18950 16930 A73J--443-L---STFCK3 3 3.00 853 23500 22220 20630 A73J--443-L---STFCL3 5 4.80 1010 27850 26900 25600 A73J--483-L---STFCJ3 2 2.00 660 22730 20750 18250
48" A73J--483-L---STFCK3 3 2.90 740 25400 23650 21650
A73J--483-L---STFCL3 5 4.90 895 30700 29350 27800 A73J--543-L---STFCJ3 2 2.00 497 25150 22170 14000
54"
A73J--543-L---STFCK3 3 3.00 573 28970 26500 22600 A73J--543-L---STFCL3 5 4.80 671 33950 31900 29500 A73J--543-L---STFCM3 71⁄2 7.50 786 39700 37970 36100 A73J--603-L---STFCK3 3 3.00 496 33800 30500 26400
60"
A73J--603-L---STFCL3 5 5.00 595 40550 37900 34900 A73J--603-L---STFCM3 71⁄2 7.30 672 45750 43400 40700 A73J--603-L---STFCN3 10 9.70 747 51000 49000 46700
Max.
CFM @ SP
Size Model Code HP BHP RPM 0" 1/8" 1/4"
A71J--282-N---STFCD31⁄4 0.28 1725 5480 4160 2450 A71J--282-N---STFCF31⁄2 0.45 1725 6630 5700 4600 A71J--282-N---STFCG33⁄4 0.71 1725 8230 7430 6450 A71J--282-N---STFCH3 1 0.99 1750 8740 8000 7170
28"
A71J--286-P---STFCI3 1
1
2 1.50 1750 9580 9140 8680 A71J--286-P---STFCJ3 2 2.00 1750 11100 10670 10180 A71J--282-N---STFCD41⁄4 0.27 1140 5690 4400 A71J--283-L---STFCG43⁄4 0.68 1140 7710 7080 6340 A71J--284-W---STFCH4 1 1.10 1160 9370 8760 8120 A71J--284-W---STFCF51⁄2 0.43 850 6870 6010 A71J--322-N---STFCH3 1 1.00 1750 10590 9590 8390 A71J--322-N---STFCJ3 2 2.00 1750 13620 12800 11870 A71J--322-N---STFCF41⁄2 0.55 1140 8850 7460
32"
A71J--326-P---STFCH4 1 0.83 1160 9520 8630 7450 A71J--323-L---STFCI4 11⁄2 1.50 1160 11580 10750 10050 A71J--324-W---STFCJ4 2 2.20 1160 13730 13100 12370 A71J--323-L---STFCF51⁄2 0.60 850 8500 7400 5000 A71J--324-W---STFCH5 1 0.93 870 10300 9430 A71J--362-N---STFCH3 1 1.10 1750 12700 11160 9200 A71J--362-N---STFCJ3 2 2.00 1750 15650 14500 13270 A71J--362-N---STFCK3 3 2.80 1750 18100 17180 16200 A71J--362-N---STFCF41⁄2 0.54 1140 10180 8220 5400
36"
A71J--362-N---STFCH4 1 1.10 1160 13460 12080 10500 A71J--363-L---STFCJ4 2 2.30 1160 16530 15750 14870 A71J--364-W---STFCL4 5 3.80 1160 20300 19460 18540 A71J--362-N---STFCF51⁄2 0.43 850 9790 7680 A71J--363-L---STFCH5 1 1.00 870 12510 11450 10220 A71J--364-W---STFCI5 11⁄2 1.60 870 15230 14100 12650 A71J--442-N---STFCH4 1 0.97 1160 16640 14350 11270 A71J--442-N---STFCJ4 2 2.20 1160 21880 19800 17600 A71J--442-N---STFCK4 3 3.50 1160 25600 23950 22200 A71J--446-P---STFCL4 5 5.10 1160 28500 27450 26300
44" A71J--442-N---STFCH5 1 0.98 870 16830 13840 9600
A71J--442-N---STFCI5 11⁄2 1.50 870 19300 17100 14450 A71J--446-P---STFCJ5 2 2.10 870 21100 19600 17900 A71J--443-O---STFCK5 3 3.10 870 24000 22700 21300 A71J--444-W---STFCL5 5 5.00 870 29450 27930 26400 A71J--482-N---STFCJ4 2 2.20 1160 24450 22230 19900 A71J--482-N---STFCK4 3 3.10 1160 27530 25400 23050 A71J--482-N---STFCL4 5 5.40 1160 32800 31000 29050
48" A71J--482-N---STFCJ5 2 2.20 870 24450 21850 18700
A71J--484-A---STFCK5 3 3.30 870 28570 26650 24350 A71J--483-L---STFCL5 5 4.30 870 30100 28550 26900 A71J--484-A---STFCJ6 2 2.20 690 25230 22650 19300 A71J--542-N---STFCK4 3 2.90 1160 30500 27650 24450 A71J--542-N---STFCL4 5 5.00 1160 38200 35750 33200 A71J--542-N---STFCM4 71⁄2 7.10 1160 42500 40200 37750
54"
A71J--542-N---STFCK5 3 3.20 870 31900 28800 25300 A71J--544-A---STFCL5 5 5.50 870 34400 31500 25750 A71J--544-A---STFCM5 71⁄2 8.20 870 41050 38800 35700 A71J--544-A---STFCK6 3 3.35 690 30100 26800 18400 A71J--546-A---STFCL6 5 5.50 690 36200 33100 26700 A71J--602-N---STFCK4 3 3.80 1160 36000 32250 28300 A71J--602-N---STFCL4 5 5.20 1160 42650 39700 36000 A71J--602-B---STFCM4 71⁄2 7.40 1160 48500 45600 42650 A71J--602-N---STFCN4 10 9.90 1160 54000 50400 46000 A71J--602-N---STFCK5 3 3.00 870 36500 32200 27250
60"
A71J--602-A---STFCL5 5 5.60 870 45650 42000 38280 A71J--604-A---STFCM5 71⁄2 8.40 870 48600 46350 13850 A71J--604-A---STFCN5 10 10.90 870 54400 52200 19950 A71J--603-L---STFCO5 15 13.50 870 60600 58750 56600 A71J--604-A---STFCK6 3 3.30 690 34370 30900 26930 A71J--604-A---STFCL6 5 5.50 690 43050 40250 37270 A71J--603-L---STFCM6 7
1
2 6.80 690 48100 45700 43200
26
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Series 71J - Direct Drive Hoodjet Ventilator Rating Table
Series 75J - Reversible Hoodjet Ventilator Rating Table
Series 73J - Belted Hoodjet Ventilator Ventilator Rating Table
All belted fan ratings include transmission losses.
NOTE: Shaded ratings not recommended for intake use. When specifying, be sure to include SERIES, SIZE, and TYPE.
Page 27
27
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
The Series 26 unit, equipped with reversible airfoil propeller, provides exhaust ventilation in warm weather and recirculation of warm ceiling air down to floor level in cool weather.
Standard Features
Sizes – 24", 30", 36", 42", 48", 54" and 60" Performance from 7,500 to 54,761 CFM at free air.
Construction – a removable galvannealed windband on sizes through 54". On 60" size, material shall be constructed of painted mild steel. Dampers open automatically when unit is used for exhaust, closes weather-tight when unit is used for recirculation. During exhaust operation, discharge air effectively prevents the entry of rain. The recirc section is constructed of 12 ga. hot rolled steel, painted. Aluminum recirc ventilators are available; entire unit is constructed of aluminum with stainless steel hardware.
Propellers – one-piece cast aluminum reversible airfoil propeller in a direct drive reversible panel fan in the recirc section of the housing.
Sizes – 24" to 42" – 6 blade – Type R Sizes – 48" to 60" – 6-blade adjustable – Type AAR
Fan Assembly – consists of two curved orifices welded together face-to-face. The same efficient performance exists for either exhaust or recirc operation.
Hinged Access Door – equipped with two flush head, button-type latches providing easy access to motor, shutters and controls.
Shutters – two automatic shutters constructed of aluminum are built into each unit located in the lower section of the housing.
Motors – totally enclosed, fan cooled motors are standard. Special motors are available upon request.
Lifting lugs – welded at two opposite (diagonal) inside corners of the plenum section furnished as standard for ease in handling this section during installation.
Unit Installation – lower recirc section (containing fan and shutters, factory installed) and upper ventilation housing are shipped separately for assembly at job site. Recirc section drops through the roof for ease of installation.
Accessories
Coatings – special coatings are available upon request.
Diffusers – 2-and 4-way diffusers are available for all sizes.
Birdscreen – for installation in throat section. Fabricated of 1/2" wire mesh.
Controls – for reversing the motor are the only ones required for unit operation. Reversal may be manual or automatic. Units available with or without controls. Units ordered without controls provided less damper actuators.
Adapter Bases – slope or peak adapter bases available as an option. Specify slope per foot.
Prefabricated Curbs – available for flat, slope or peak roof mounting. Curbs are designed for metal, concrete or wood roof decks that are not surface insulated. Available either 8" or 12" high of galvanized or aluminum construction. See Page 34.
Recirculating Roof Ventilator
Series 26
ABS Certificate
of Design Assessment
Received
Page 28
Motor
Peak
CFM@Static Pressure
Approx.
Blade Fan Net Install.
Size Model Code Angle HP RPM BHP 0" 1/8" 1/4" 3/8" Wt. #
24"
A26---246RB250STFCH3 25° 1 1750 1.13 7530 7100 6740 6400 425 A26---246RA290STFCI3 29° 11⁄2 1750 1.61 8500 8150 7800 7400 435
30"
A26---306RA250STFCH4 25° 1 1160 1.09 9650 8970 8230 7260 624 A26---306RB290STFCI4 29° 11⁄2 1160 1.57 10650 10000 9325 8400 629
36"
A26---366RA240STFCJ4 24° 2 1160 2.33 14700 13950 13070 12300 745 A26---366RB280STFCK4 28° 3 1160 3.29 15550 14600 13850 13200 770
42" A26---426-R290STFCK5 29° 3 870 3.35 22100 20900 19700 18600 1012
48"
A26---486AR215STFCK5 21.5° 3 870 3.40 26250 25000 23700 22200 1199 A26---486AR270STFCL5 27° 5 870 5.45 32100 30800 29400 27900 1254 A26---546AR220STFCK6 22° 3 690 3.35 30500 28700 26800 24750 1462 A26---546AR280STFCL6 28° 5 690 5.62 37700 35850 33800 31600 1577
54" A26---546AR200STFCL5 20° 5 870 5.10 34900 33500 32000 30500 1422
A26---546AR250STFCM5 25° 71⁄2 870 7.90 42800 41300 39750 38250 1476 A26---546AR280STFCN5 28° 10 870 10.55 47550 46100 44650 43100 1532 A26---606AR225STFCL6 22.5° 5 690 5.48 42911 40907 38800 36796 1750 A26---606AR265STFCM6 26.5° 71⁄2 690 7.40 48565 46376 44188 41687 1800
60"
A26---606AR280STFCN6 28° 10 690 8.40 51800 49750 47500 45350 1860 A26---606AR165STFCL5 16.5° 5 870 5.48 39412 37918 36321 34879 1600 A26---606AR205STFCM5 20.5° 71⁄2 870 7.94 47556 46089 44361 42947 1650 A26---606AR230STFCN4 23° 10 870 10.50 54761 53051 51600 49735 1710
28
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
FAN
SIZE ABCDGHJM
24 243⁄16 281⁄2 54 36 351⁄4 13 167⁄8 13H x 25W
30 303⁄16 351⁄2 581⁄2 42 411⁄4 16 183⁄8 16H x 32W
36 363⁄16 421⁄2 623⁄4 48 471⁄4 19 195⁄8 19H x 39W
42 423⁄16 481⁄2 671⁄4 54 531⁄4 22 211⁄8 22H x 45W
48 483⁄16 541⁄2 701⁄4 641⁄4 631⁄2 25 211⁄8 25H x 51W
54 543⁄16 601⁄2 733⁄4 701⁄4 691⁄2 28 215⁄8 28H x 57W
60 603⁄16 661⁄2 881⁄8 793⁄4 79 31 33 31H x 63W
Principal Dimensions (Inches) – Series 26
Rating Table – Series 26
NOTE: Performance includes resistance through ventilator and shutters. RPM shown is nominal and performance is based on actual speed of test.
O.D. FLANGE
G
DROP THRU SECTION
LIDS
24*
AIRFLOW
ACCESS
24
OPENING
PREFAB. CURB
C
ACCESS OPENING
H
ACCESS
DOOR
SHUTTER OPENING
M
H x W
D
SQ. I.D.
J
I.D.
REVERSIBLE
PANEL FAN
A
O.D.
B
Page 29
29
www.hartzellfan.com
1 (800) 336-3267
A dual purpose ventilator offering a simple, economical approach to energy conservation in lieu of complicated and costly heat recovery systems. The Series 27 provides roof ventilation, either exhaust or intake, plus the option of recirculating ceiling air and, if desired, mixing of ceiling air with ambient outside air.
Standard Features
Sizes – 24", 30", 36", 42", 48", 54" and 60" Performance from 7,350 to 53,755 CFM (intake); 7,220 to 52,316 CFM (exhaust).
Construction – roof hood and base are constructed of painted galvannealed steel as standard. The recirc section is 12 ga. hot rolled steel, painted. Also available in aluminum construction upon request.
Propellers – one-piece cast aluminum reversible airfoil propeller in a direct drive reversible panel fan in the recirc section of the housing.
Sizes – 24" to 42" – 6-blade – Type R Sizes – 48" to 60" – 6-blade adjustable – Type AAR
Hinged Access Doors – two access doors are furnished as standard. Provide easy access to the motor operated shutter as well as the fan assembly.
Shutters – heavy duty, center pivoted motor operated type. Louvers constructed of 16 ga. galvanized steel. One motor operator controls two shutters located in the lower recirc section.
Motors – totally enclosed, fan cooled motors are standard. Special motors are available upon request.
Control Mode Package (NEMA 1) – specify mode package required.
Mode #1 – INTAKE-RECIRC – provides intake ventilation plus the
capability of recirculating ceiling air. Mode #2 – INTAKE-EXHAUST-RECIRC – for intake or exhaust operation,
recirc shutter is closed; inlet-outlet shutter is fully open. For recirculation operation, fan pulls ceiling air through recirc shutter; inlet-outlet shutter is fully closed.
Mode #3 – INTAKE-RECIRC-MIX – mix mode is used when a mixture of ambient outside air and warm ceiling air is required. Recirc shutter and intake shutter modulate to provide exact air mixture.
Mode #4 – INTAKE-RECIRC-MIX-EXHAUST – provides intake or exhaust roof ventilation; also, recirculation of ceiling air; or a combination of ambient outside air and ceiling air.
Starters – Each control mode package listed above is available with any of the following starters. Specify type required.
TYPE A – starter only TYPE B – combination starter, non-fused disconnect. TYPE C – combination starter, fusible disconnect. (Modes 2 and 4 use
reversing starters.)
Control Installation – customer must supply wiring between the starter, remote control station, and the unit. Controls are shipped separately for mounting and wiring at job site. Units ordered without controls provided less damper actuators.
Lifting Lugs – welded to the top of the plenum section furnished as standard for ease in handling this section during installation.
Unit Installation – lower recirc section (containing fan and shutters, factory installed) and upper ventilator housing (base and hood), are shipped separately for assembly at job site. Recirc section drops through the roof for ease of installation.
Accessories
Coatings – special protective coatings available upon request.
Diffusers – 2-and 4-way diffusers are available for all sizes.
Birdscreen – for installation in hood or throat section. Fabricated of 1/2" wire mesh.
Adapter Bases – slope or peak bases available. Specify slope per foot.
Prefabricated Curbs – available for flat, slope or peak roof mounting. Curbs are designed for metal, concrete or wood roof decks that are not surface insulated. Available either 8" or 12" high of galvanized or aluminum construction. See Page 34.
Recirculating Hooded Roof Ventilator
Series 27
Bulletin A-157-L
ABS Certificate
of Design Assessment
Received
Page 30
30
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
I.D.
SQ.
2 1/4
16 5/8
4 3/8
SQ. OUTSIDE
D
G
B
A
J
J
L
7 GA.
K
C
H
F
E
18 GA. GALV.
LIFTING LUGS
OPTIONAL–FILTER RAILS OPTIONAL–DISPOSIBLE OR PERMANENT FILTERS
CENTER PIVOTED MOTOR OPERATED SHUTTER
ACCESS DOORS
TEMPERATURE CONTROLLER
REVERSIBLE PANEL FAN SHOWN
* 24" IS STANDARD DIMENSION CUSTOMER TO CHECK AND MAKE SURE SHUTTER ACCESS DOOR CLEARS ALL CEILING STRUCTURES
SQ. I. D. BASE
14 GA. GALV.
*24 REF.
12 GA.
H. R. S.
SHUTTER OPENING
24
OPENING
ACCESS OPENING
DIFFUSER I. D.
12
4
SQ. O. D. FLANGE
OPTIONAL BIRD SCREEN
(SHOWN IN THROAT)
LIFTING HOOKS (2) REQíD
LOCATED IN DIAGONALLY
OPPOSITE CORNERS
SHUTTER MOTOR
AND LINKAGE
CENTER PIVOTED
MOTOR OPERATED
SHUTTER
OPTIONAL
DIFFUSER
FAN
SIZE ABCDEFGHJKL
24 241⁄4 281⁄4 70 361⁄4 153⁄4 72 36 13 1613⁄16 1027⁄16 13
30 311⁄4 351⁄4 741⁄2 431⁄4 171⁄2 80 43 16 185⁄16 10811⁄16 16
36 381⁄4 421⁄4 783⁄4 501⁄4 193⁄4 90 50 19 199⁄16 1153⁄16 19
42 441⁄4 481⁄4 831⁄4 561⁄4 21 96 56 22 211⁄16 12015⁄16 22
48 501⁄4 541⁄4 861⁄4 621⁄4 261⁄4 120 62 25 211⁄16 1293⁄16 25
54 561⁄4 601⁄4 893⁄4 681⁄4 305⁄8 140 68 28 219⁄16 1371⁄16 28
60 621⁄4 661⁄4 933⁄4 741⁄4 33 1505⁄8 74 31 229⁄16 1437⁄16 31
Principal Dimensions – Series 27
NOTE: Performance includes resistance through ventilator and shutters. RPM shown is nominal and performance is based on actual speed of test.
Rating Table – Series 27
Motor
Peak
CRM@S.P. Intake CRM@S.P. Exhaust
Approx.
Blade Fan Net Install.
Size Model Code Angle HP RPM BHP 0" 1/8" 1/4" 3/8" 0" 1/8" 1/4" 3/8" Wt. #
24"
A27---246RB250STFCH3 25° 1 1750 1.12 7350 7000 6650 6300 7220 6875 6510 6180 742 A27---246RA290STFCI3 29° 11⁄21750 1.59 8300 8000 7650 7250 8200 7850 7500 7125 752
30"
A27---306RA250STFCH4 25° 1 1160 1.15 9400 8800 8050 7100 8820 8250 7450 6500 1027 A27---306RB290STFCI4 29° 11⁄21160 1.50 10450 9800 9100 8100 9750 9120 8300 7300 1032
36"
A27---366RA240STFCJ4 24° 2 1160 2.10 14550 13800 12975 12250 13300 12625 12100 11600 1256 A27---366RB280STFCK4 28° 3 1160 2.45 15500 14750 14000 13300 14250 13600 13000 12350 1283
42" A27---426-R290STFCK5 29° 3 870 3.60 21000 19950 19000 18000 20180 19250 18600 17200 1451
48"
A27---486AR22STFCK5 22° 3 870 3.40 26600 25300 24250 23000 25750 24650 23500 22250 1871 A27---486AR270STFCL5 27° 5 870 5.60 32000 31000 29450 28000 31000 29750 28400 26800 1926 A27---546AR220STFCK6 22° 3 690 3.20 30250 28500 26750 25000 29300 27750 26000 24000 2295 A27---546AR280STFCL6 28° 5 690 5.40 37400 35500 33500 31500 36350 34400 32500 30350 2410
54" A27---546AR200STFCL5 20° 5 870 4.80 34250 33000 31600 30200 33500 32250 31000 29500 2255
A27---546AR250STFCM5 25° 71⁄
2
870 7.60 42600 41000 3950 38000 41300 40000 38300 36800 2305 A27---546AR280STFCN5 28° 10 870 10.00 47300 46000 44250 42600 45900 44350 42600 41250 2365 A27---606AR220STFCL6 22° 5 690 5.30 41400 39300 37400 35500 40200 38700 36500 34500 2740 A27---606AR265STFCM6 26.5° 71⁄
2
690 7.71 48148 45855 43510 41270 46533 44292 42208 39915 2800
60"
A27---606AR280STFCN6 28° 10 690 8.90 51100 49000 47000 44500 49400 47350 45200 43000 2860 A27---606AR160STFCL5 16° 5 870 5.30 38100 36750 35200 33800 37300 36000 34650 33000 2590 A27---606AR195STFCM5 19.5° 71⁄
2
870 7.96 46454 45065 43470 41670 45374 43882 42390 40949 2645 A27---606AR225STFCN5 22.5° 10 870 10.76 53755 52162 50620 49130 52316 50774 49335 47793 2700
Page 31
31
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Industrial, commercial, and residential spaces need proper ventilation to facilitate a healthy and protective environment for people, inventory, machinery, and structures. Ventilation itself may be affected in a variety of ways, beginning with opening windows and doors.
Typical industrial processes generate heat; people generate heat; and building structures pass solar heat gains. Warm air rises and can be trapped if not properly allowed to escape causing stratification of air layers and contaminated conditions. Power roof ventilators are an effective and efficient alternative to ventilation by convection. The proper application and use of power ventilators allows better control of air patterns and air distribution.
Good, general ventilation practice and design ensures proper dilution ventilation, heat load control, contaminated air exhaust, and fresh air supply. As a result, operating personnel will be more comfortable and efficient; manufacturing equipment and process­es will be able to function more properly.
Selection of Power Roof Ventilators
Circulating Air Volume
The rate of air change is the most frequently used method for cal­culating air volumes for general conditions. It is based on the the­ory that a complete air change must be within a certain interval. Listed below is a recommended guide for average air changes for general ventilation.
Roof Ventilator Application
Rate of Air Change Method
The rate of air change will vary with the type of structure, but a generally accepted rate is one air change every 5 minutes.
Air volume is found be determining the plant volume in cubic feet to be ventilated and then dividing the cubic feet by the desired rate of air change.
EXAMPLE: Ventilated area 120' x 50' x 20' = 120,000 cu. ft. Air Exchange Rate - change every 5 minutes.
120,000 cu. ft.
5 min
= 24,000 CFM
Plant Layout
The usual method of designing plant ventilation layout is to first determine the amount of CFM required (see above). Secondly, determine the size and number of units needed to meet require­ments. The units are generally symmetrically spaced.
EXAMPLE: Ventilated area 120' x 50' x 20'. Air Exchange Rate - one change every 5 minutes.
120,000 cu. ft.
5 min.
= 24,000 CFM required
Determine number of ventilators required: Divide 24,000 CFM (system requirement) by number of units
desired – in this case 2. Capacity requirement for each ventilator – 12,000 CFM.
Symmetrical spacing should be used whenever possible; how­ever, care must be taken to adequately ventilate particularly trou­blesome areas and that the roof ventilator air supply is not short cycled by open windows, air supply unit or wall louvers.
40'
25'
50'
120'
Minutes
Per Change
Assembly Halls . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Auditoriums . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Bakeries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Boiler Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Bowling Alleys . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Churches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-15
Dairies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Dance Halls . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Dry Cleaners . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Engine Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Factories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Forge Shops . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Foundries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Garages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Generator Rooms . . . . . . . . . . . . . . . . . . . . . . . .2-5
Gymnasiums . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Kitchens – Hospital . . . . . . . . . . . . . . . . . . . . . . .2-5
Kitchens – Restaurant . . . . . . . . . . . . . . . . . . . . .1-3
Laboratories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Laundries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Machine Shop . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Markets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Mills . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Packing Houses . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Plating Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Printing Plants . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Toilets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
Transformer Rooms . . . . . . . . . . . . . . . . . . . . . . .1-5
Warehouses . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10
Page 32
32
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Exhaust and Supply
Proper ventilation design is not limited to exhaust only. Any volume of air that is exhausted from a space must be made up by supply air in some fashion. Exhaust air will be made up to a space either naturally, by entering through building cracks, open doors, etc., or by proper ventilation design. Therefore, air supply, in addition to air exhaust, should be considered. In cooler climates tempered make-up air should be considered. To effect proper sweeps and flows through the area to be ventilated, supply air may be introduced through the side walls or the roof. Contact your local Hartzell representative for additional information on wall ventilators and make-up air units.
In many cases it may be necessary to filter the supply air. Please see page 22.
There are basically two power roof ventilator configurations. Upblast units are available for exhaust applications. They are designed to throw the exhaust air volume up and away from the building. When properly designed, exhaust air flow in operation prevents the entry of weather; backdraft dampers close securely to prevent air return and leakage when a unit is not in operation. Hooded roof ventilators are available for exhaust or supply. In the supply mode, hooded roof ventilators can be fitted with permanent or disposable filters. When properly designed, the ventilator hood accommodates low air velocities so as to minimize static pressure losses through the hood and prevent entrainment of weather when used in the supply mode.
In addition, Hartzell offers a complete line of 100 percent reversible roof ventilators when periodic operation in either mode may be required.
Recirculating power roof ventilators which are designed to intake fresh air, exhaust plant air, or recirculate clean plant air are also available. Your Hartzell sales representative can provide more information on these standard units.
Ambient Conditions
The ambient air temperature and air quality require attention when power roof ventilators are being selected. Extreme heat or cold may require special motor insulation (see the table that follows) or bearings, lubricants, belts, and materials of construction.
Application Considerations
When a need for power roof ventilation has been identified and your initial design and selections made, you should consider the following items to ensure a proper, functional, and satisfactory selection:
Maintenance – power roof ventilators are available in direct- and belt-drive. Air quality, air temperature, and maintenance require­ments for belts and bearings should be considered. Accessibility for maintenance of the ventilator and accessory items is an important issue.
Installation – power roof ventilator weights and sizes should be considered for lifting methods and mounting on the roof. Proper roof opening sizing, and free area in the opening are essential. Power roof ventilators should be secured to the building structure properly by means of attachment to a permanent structure or a pre-fabricated roof curb (see page 34).
Power Supply – care should be taken to specify proper volt­age, phase and cycle for the power roof ventilator motor as well as accessories and controls.
Wind – care should be taken to ensure that exhaust and sup­ply fan layout on the roof works with, rather than against, the prevailing winds. For example, when power roof exhaust and supply units are both used on the same roof, exhaust fans should be positioned down wind of supply fans.
In addition, wind loads should be considered and standard units modified or reinforced to operate properly in high-wind condi­tions (see page 34).
Options – see pages 33 and 34 for typical standard options and accessories. Hartzell Fan, Inc. is able to modify standard products and accessories to meet your special requirements.
Furthermore, for variable exhaust and supply requirements, your Hartzell sales representative can assist you in the proper application of AC speed controls with power roof ventilators.
Design assistance for proper plant ventilation is available through recommended practices in industrial publications. However, your Hartzell representative can provide you with selection and application assistance based on experience with a variety of solutions to general and process ventilation problems. Contact your authorized Hartzell sales representa­tive today.
Typical Application – Series 26
The Series 26, Recirculating Roof Ventilators and Series 27, Recirculating Hooded Roof Ventilators provide roof ventilation during the summer months and heat recovery in winter by recirculating warm air from the ceiling down to floor level.
During the summer months not much can be done with hot ceiling air but to exhaust it out of the plant by use of ventilators and exhaust fans.
The huge reservoir of heated air resting at ceiling level can be recirculated for comfort heating during the cold winter months, providing the ceiling air is relatively clean and fume-free. In this age of rising fuel costs, it doesn’t make "economic sense" to exhaust warm ceiling air from a plant, then spend money for fuel to heat cool air for worker comfort and efficiency.
Hartzell’s Recirculating Roof Ventilators were designed to economically solve both summer ventilation and winter heat recovery problems. More than 70 Hartzell offices can provide specific perform­ance and installation data to meet your requirements. Call your Hartzell representative for technical assistance.
Motor Insulation Maximum Ambient Temperature
Standard 105°F
Class F 140°F
Class H 176°F
Class HH 212°F
Note: For extreme heat or cold, contact your Hartzell Sales Representative.
Corrosive fumes or dust in the air stream may require special materials of construction or coatings. For some extreme corrosive applications, Hartzell offers a complete line of upblast and hooded fiberglass roof ventilators. Contact your Hartzell sales representative for more information on the availability and application of these products.
Noise
Power roof ventilators generate sound at different levels depending on their power, efficiency, operating speed, and overall design. This sound may be air borne or structure borne and should be considered in accordance with industrial safety and hygiene regulations. Slow-speed, high-volume, belted roof ventilators (Series 16) are typically well suited for these applications. In severe cases, attenuating devices and materials may be applied.
In addition to in-plant requirements, sound power levels at the property line should also be considered.
WARM AIR
RISING
RECIRCULATING AIR
WINTER ONLY
EXHAUST AIR SUMMER ONLY
WARM
AIR
WARM AIR
RISING
Page 33
33
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Bird Screen
Half-inch square opening wire mesh, 19 ga. galvanized steel available for all ventilators. Aluminum bird screen also available. Special coating may require heavier gauge.
Inspection Door – Series 69
Series 69 is available with a hinged inspection door.
Disconnect Switch
NEMA watertight enclosure available mounted and wired, provides safety during maintenance.
Guard
Painted steel guard protects floor area from falling debris and the ventilator from vandalism.
Combination Motor Cover and Belt Guard
Series 69 upblast ventilator only. Provides weather protection as well as guarding of the drive sheave and belts. Covers are vented.
Extended Lube Tubes
Extended Lube Tubes will be provided from the motor on direct drive units and from the bearings and motor on belt drive and belted units to the exterior of the housing only when the motor is designed for external lubrication fittings (relubricable versus sealed motor bearings).
Coatings
Non-standard coatings are available. A catalyzed coal tar epoxy offers excellent resistance to weather. Also available is an air dry epoxy offering a corrosive resistant ventilator. Other types of non­standard coatings can be furnished. Standard paint is industrial grade enamel suitable for interior or exterior industrial applica­tions. Contact your Hartzell representative for further information.
Swing-Out Fan Construction
Fan casing is split and hinged. Section containing fan, drive assembly and propeller swings open and away from installed ventilator. Provides service access to propeller and drive components. See pages 10 and 11.
Stack Cap Options
Fiberglass Damper Lids
Fiberglass lids in place of standard galvanized construction offers increased durability and longer lid life. An additional dividend is fiberglass insulation qualities resulting in less heat loss when the unit is idle during winter months. Series 61, 63 and 69 units only.
Fusible Link
Spring operated, positive lid opener for Series 61, 63 and 69 models. When the temperature through the ventilator exceeds 165°F, the fusible link allows the spring-operated lid opener to lock the stack cap lids in the upright position. Provides gravity ventilation in case electricity to the ventilator is interrupted during a fire.
Magnetic Latches
For positive lid closure when unit is not in operation. Prevents lid flutter when positive pressure exists in building. Series 61, 63 and 69 units only.
Options and Accessories
SAFETY ACCESSORIES, APPLICATION AND USE WARNING
The safe application and use of equipment supplied by Hartzell Fan, Inc. is the responsibility of the installer, the user, the owner, and the employer. Since the application and use of its equipment can vary greatly, Hartzell Fan, Inc. offers various product types, optional safety accessories, and sound performance data per laboratory tests. Hartzell Fan, Inc. sells its equipment with and without safety accessories, and accordingly, it can supply such safety accessories only upon receipt of an order. The need for safety accessories will frequently depend upon the type of system, fan location and operating procedures being employed. The proper protective safety accessories to meet company standards, local codes, and the requirements of the Occupational Safety and Health Act must be determined by the user since safety requirements vary depending on the location and use of the equipment. If applicable local conditions, standards, codes or OSHA rules require the addition of the safety accessories, the user should specify and obtain the required safety accessories from Hartzell Fan, Inc. and should not allow the operation of the equipment without them.
Owners, employers, users and installers should read “RECOMMENDED SAFETY PRACTICES FOR USERS AND INSTALLERS OF INDUSTRIAL AND COMMERCIAL FANS” published by the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, Illinois 60004. A copy of this publication is enclosed with each fan shipped from Hartzell Fan, Inc., and is available upon request at Hartzell’s office in Piqua, Ohio 45356.
Please contact Hartzell Fan, Inc. or your local Hartzell representative for more information on product types, safety accessories, and sound performance estimates.
Remember, the selection of safety accessories and the safe application and use of equipment supplied by Hartzell Fan, Inc. is your responsibility.
Bird Screen
Series 15, 16 and 17
Page 34
Curb Adapter Base
All models available for flat, slope or peak base and are suitable for high wind loads due to tubular construction.
Prefabricated Curb
The IRC-1 prefabricated curb is for flat roof installation of Hartzell roof ventilators. The curb is designed for metal, concrete or wood roof decks that are not surface insulated.The curb is available either 8" or 12" high. Sizes 12" - 60" only. For larger sized curbs, contact your Hartzell representative for assistance.
Prefabricated curbs are designed to support the weight of the fans catalogued herein, and attachments not exceeding over 100 addi­tional pounds in a 40 mph wind. Non-standard curb construction is available.
Features:
Nailer Strip – built-in cant strip facilitates fastening the ventila­tor to the curb.
Glass Fiber Insulation – a rigid 1 1/2" thick 3 lbs. density liner eliminates condensation problems.
Neoprene Sealer – 1/4" strip.
Construction – galvanized steel (18 ga.) or aluminum (.063).
Welded Seams.
34
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Hooded Roof Ventilator Options
High Wind Load Construction
Series 15, 16, 17 and 19 hooded ventilators are designed to withstand wind loads up to 60 mph. For wind loads between 60 mph and 90 mph, specify high wind load construction, which includes guy wires to secure hood to roof structure.
Hood Roller Slide Rail
Slide rail design is available in sizes 42" – 84". They consist of roller wheels, guide rails, and rigid supports for stability. This package allows the hood halves to be unbolted and rolled apart providing 100% accessibility to the fan assembly without having to remove either of the hood halves from the unit.
Fan
Size1214161820242832364042485460
A211/4 231/4 251/4 271/4 291/4 351/4 411/4 411/4 471/4 491/4 531/4 571/2 631/4 691/2 B291/4 311/4 331/4 351/4 371/4 431/4 491/4 491/4 551/4 571/4 611/4 651/2 711/2 771/2
Access door showing mounting position for backdraft dampers.
12"
12"
M
M
SLOPE
PEAK
Fan
Size12141618202428303236404244485460
A211/4 231/4 251/4 271/4 291/4 351/4 411/4 411/4 411/4 471/4 491/4 531/4 531/4 571/2 631/2 691/2 B291/4 311/4 331/4 351/4 371/4 431/4 491/4 491/4 491/4 551/4 571/4 611/4 611/4 651/2 711/2 771/2
Principal Dimensions for Series 69
Principal Dimensions for Series 61 and 63
Fan
Size1824303642485460
A29
1
/2 351/2 421/2 491/2 551/2 611/2 671/2 731/2
B37
1
/2 431/2 501/2 571/2 631/2 691/2 751/2 811/2
Principal Dimensions for Series 15, 16 and 17
Specifications and dimensions are subject to change. Certified prints are available.
Series 15, with optional filters
and slide rail package
Backdraft Dampers
Available in galvanized steel, aluminum or coated construction, automatic, manual or motor operated configuration, factory installed. The damper is mounted in the base section of the ventilator. Access to the dampers is provided through a hinged type door with quick release latches. This door allows easy removal of dampers in fully open position.
Fan Size 24 30 36 42 48 54 60
A35
1
/2 421/2 491/2 551/2 611/2 671/2 731/2
B43
1
/2 501/2 571/2 631/2 691/2 751/2 811/2
Principal Dimensions for Prefabricated Curbs – Series 27
Fan Size 24 30 36 42 48 54 60
A35
1
/4 411/4 471/4 531/4 631/2 691/2 79
B43
1
/4 491/4 551/4 611/4 711/2 771/2 87
Principal Dimensions for Prefabricated Curbs – Series 26
8" or 12" available
SQ.
1-1/2"
NEOPRENE SEALER
SQ.
Page 35
HartKool Cooling Fans Sizes: 18" to 36" 4236 to 13,450 CFM at free air Request Bulletin A-120
Gas Fired Econo Units Heating capacities from 950,000 to 2,900,000 BTU/ HR Request Bulletin A-125
Gas Fired Door Heaters Heating capacities from 700,000 to 990,000 input BTU Request Bulletin A-125
35
Bulletin A-157-L
www.hartzellfan.com
1 (800) 336-3267
Stationary or Portable Utility Fans Sizes: 20" to 36" 4168 to 18,770 CFM at free air Request Bulletin A-120
Portable Pedestal Fans Sizes: 20" to 48" 4168 to 32,700 CFM at free air Request Bulletin A-120
Cool Blast Fans
Cool blast fans are ideal for cooling personnel or equipment, smoke diffusion, product cooling and insect dissipation.
Stationary Pedestal Fans Sizes: 20" to 48" 4168 to 32,700 CFM at free air Request Bulletin A-120
Reversible Ring Fans Sizes: 18" to 60" 3350 to 49,800 CFM at free air Request Bulletin A-109
Belted High Volume Ring Fans Sizes: 72" to 144" 63,000 to 327,000 CFM at free air Request Bulletin A-109
Propeller Fans and Wall Ventilators
Propeller fans and wall ventilators are designed for general ventilation, fume removal, cooling, air supply or exhaust applications.
Standard and Lo-Noise Ring Fans Sizes: 12" to 120" 1475 to 229,000 CFM at free air Request Bulletin A-109
Standard and Lo-Noise Panel Fans Sizes: 12" to 60" 1475 to 66,850 CFM at free air Request Bulletin A-109
Gas Fired Equipment
Steam Unit Heaters With 1- or 2-row coils Heating capacities from 31,000 to 524,000 BTU/ HR Request Bulletin A-121
Gas Fired Make-up Air Units 3,000 to 100,000 CFM Units 300,000 to 10,000,000 BTU/ HR Axial or Centrifugal
Fan Sections. Request Bulletin A-125.
Steam Fired Makeup Air Units With Propeller Fan Assembly Heating capacities from 536,000 to 5,362,000 BTU/ HR Request Bulletin A-128
Steam Fired Face and Bypass Units Axial or Centrifugal Assemblies Heating capacities from 740,000 to 4,000,000 BTU/ HR Request Bulletin A-128
Steam Fired Equipment
Steam Fired Makeup Air Units With Centrifugal Fan Assembly Heating capacities from 740,000 to 3,826,000 BTU/ HR Request Bulletin A-128
Hartzell gas and steam fired make-up air equipment can be used to supply tempered make-up air or as a total fresh air heating system. Make-up air is needed in a plant to eliminate negative pressure in a building and the “sick building syndrome” associated with this problem. Hartzell also manufactures door heaters and unit heaters to complete plant heating requirements.
In addition to Power Roof Ventilators, a complete solution for your general ventilation needs...
Page 36
Hartzell Warranty
Rev. Warranty 5/1/11
LIMITED WARRANTIES
Hartzell represents to Buyer that any goods to be delivered hereunder will be produced in compliance with the requirements of the Fair Labor Standards Act of 1938 as amended.
Hartzell also warrants to Buyer its goods to be free from defects in workmanship and material under normal use and service for one (1) year after tender of delivery by Hartzell, plus six months allowance for shipment to approved stocking dealers and distributors. No warranty extends to future performance of goods and any claims for breach of warranty or otherwise accrues upon tender of delivery.
The foregoing constitute Hartzell’s sole and exclusive warranties and are in lieu of all other warranties, whether written, oral, express, implied or statutory.
LIMITATION OF LIABILITY FOR BREACH OF WARRANTY
Hartzell’s obligation for any breach of warranty is limited to repairing or replacing, at its option, without cost to Buyer at its factory any goods which shall, within such a warranty period, be returned to it with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been defective. Any request for repair or replacement should be directed to Hartzell Fan, Inc., P.O. Box 919, Piqua, Ohio 45356. Hartzell will not pay for any repairs made outside its factory without its prior written consent. This does not apply to any such Hartzell goods which have failed as a result of faulty installation or abuse, or incorrect electrical connections or alterations, made by others, or use under abnormal operating conditions or misapplication of the goods.
LIMITATION OF LIABILITY
To the extent the above limitation of liability for breach of warranty is not applicable, the liability of Hartzell on any claim of any kind, including negligence, for any loss or damage arising out of or connected with, or resulting from the sale and purchase of the goods or services covered by these Terms and Conditions of Sale or from the performance or breach of any contract pertaining to such sale or purchase or from the design manufacture, sale, delivery, resale, installation, technical direction installation, inspection repair, operation or use of any goods or services covered by these Terms and Conditions shall, in no case exceed the price allocable to the goods or services which gave rise to the claim and shall terminate one year after tender of delivery of said goods or services, plus six months allowance for shipment to approved stocking dealers and distributors. In no event will Hartzell be responsible or liable for any labor or other incidental costs associated with the removal or replacement of defective products or materials.
In no event whether as a result of breach of contract, or warranty or alleged negligence, defects, incorrect advice or other causes, shall Hartzell be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of the equipment or any associated equipment, cost of substitute equipment, facilities or services, down time costs, or claims of customers of the Buyer for such damages. Hartzell neither assumes nor authorizes any person to assume for it any other liability in connection with the sale of its goods or services.
NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
HARTZELL DOES NOT WARRANT THAT SAID GOODS ARE OF MERCHANTABLE QUALITY OR THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE. THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY AND THERE IS NO IMPLIED WARRANTY OF FITNESS.
www.hartzellfan.com
Propeller Fans
Vaneaxial Blowers
Heating Equipment –
Gas & Steam
Hartzell Fan, Inc., Piqua, Ohio 45356 • Plants in Piqua, Ohio and Portland, Indiana.
Cooling Tower &
Heat Exchanger Fans
Cool Blast & Utility Fans
Fiberglass
Axial Flow Fans
Duct Fans
Steel Centrifugal Blowers
Fiberglass Centrifugal
Blowers
Duct Axial Fans
Roof Ventilators – Steel & Fiberglass
Marine –
Mine Duty Blowers
Litho in U.S.A. A-157-L 4/08
Loading...