![](/html/9c/9c08/9c08bc15c812b4d17d5d5bb77333dea1ec74f4cdc5d5207aa9e508a96efb88f3/bg1.png)
P-K MACH® C1500H-C2000H
Outdoor Boiler Kit
Rev. 1.0 (08/7/2012)
1004905966
C.S.A Design-Certified
Complies with ANSI Z21.13/CSA 4.9
Gas-Fired Low Pressure Steam and Hot Water Boilers
ASME Code, Section IV
Certified by Harsco Industrial, Patterson-Kelley
C.S.A Design-Certified
Complies with ANSI Z21.13/CSA 4.9
Gas-Fired Low Pressure Steam and Hot Water Boilers
P-K MACH® GAS-FIRED BOILER
C1500H – C2000H
OUTDOOR BOILER KIT GUIDE
This manual is to be used in conjunction with the
P-K MACH® C1500H-C4000 Installation & Owner’s
Manual (latest edition).
Model #:_______ Serial #:_____________________
Installation Date: ___________________________________
Harsco Industrial, Patterson-Kelley
155 Burson Street, East Stroudsburg, PA 18301
Telephone: 570.476.7261
Toll Free: 877.728.5351
Facsimile: 570.476.7247
www.harscopk.com
© 2012 Harsco Corporation
Printed: 3/7/2014
![](/html/9c/9c08/9c08bc15c812b4d17d5d5bb77333dea1ec74f4cdc5d5207aa9e508a96efb88f3/bg2.png)
P-K MACH® C1500H-C2000H Outdoor Boiler Kit
Table of Contents
1.0 INTRODUCTION...................................................................................................................... 5
1.1 COMPLETED P-K MACH
2.0 INSTALLATION ....................................................................................................................... 6
2.1 REQUIRED TOOLS AND PARTS ............................................................................................. 6
2.1.1 Tools ............................................................................................................................... 6
2.1.2 Parts ............................................................................................................................... 6
2.2 AIR INLET BOX COVER INSTALLATION ................................................................................... 7
2.3 EXHAUST VENT SYTSTEM INSTALLATION ................................................................................ 8
2.4 ELECTRICAL CONNECTIONS ............................................................................................... 10
3.0 MAINTENANCE..................................................................................................................... 11
4.0 ASSEMBLY DRAWINGS ...................................................................................................... 12
4.1 ASSEMBLY DRAWING C1500H/C2000H ............................................................................. 12
®
C1500H/C2000H OUTDOOR BOILER KIT ...................................... 5
2
![](/html/9c/9c08/9c08bc15c812b4d17d5d5bb77333dea1ec74f4cdc5d5207aa9e508a96efb88f3/bg3.png)
The information contained in this document is subject to change without notice from Harsco Industrial,
Patterson Kelley.
The following words are used in this manual to denote the degree of seriousness of the individual hazards.
P-K MACH® C1500H-C2000H Outdoor Boiler Kit
Used to indicate an imminently hazardous situation which, if not avoided, will result in
death or serious injury. This signal word is to be limited to the most extreme conditions.
Indicates a potentially hazardous situation which, if not avoided, could result in death
or serious injury.
Used to indicate a potentially hazardous situation which, if not avoided, may result in
minor or moderate injury. It may also be used to alert against unsafe practices.
NOTICE/NOTE - NOTICE is the preferred signal word to address practices not related to personal injury.
The safety alert symbol is not used with this signal word.
Extensive safety information is contained in the P-K MACH® C1500H-C2000H
Installation & Owner’s Manual (latest edition) as well as warnings, installation requirements and diagrams.
3
![](/html/9c/9c08/9c08bc15c812b4d17d5d5bb77333dea1ec74f4cdc5d5207aa9e508a96efb88f3/bg4.png)
The P-K MACH® C1500H-C4000 Installation & Owner’s Manual (latest edition) must be used in conjunction
with this manual for safe and proper installation of this boiler. The boiler and these instructions are for
outdoor installation. Incorrect installation may result in injury or death.
P-K MACH® C1500H-C2000H Outdoor Boiler Kit
Shut off and lockout / tagout all utilities which may be hazardous, including electricity, gas, water, etc. before
installing the P-K MACH® Outdoor Boiler kit. Improper use or failure to lockout / tagout hazards may result in
injury.
The boiler and these instructions are for outdoor installation. Do not install in any
enclosure without proper venting. All exhaust venting must be outdoors. All installations of venting systems
should be done only by qualified venting systems personnel. Venting must be installed in accordance with
vent system manufacturer’s installation instructions and this manual. Installing a boiler or vent system using
improper installation methods or materials can result in serious injury or death due to fire or asphyxiation
from carbon monoxide or other poisonous gases. Breathing exhaust fumes may cause serious personal
injury or death.