Harris Home Fires FERVA CORSAIR Installation And Operating Instructions Manual

1
Issued: March 2012 V1.2
Harris Home Fires 41 Braddon St Addington Christchurch 8024 New Zealand Email sales@hhf.co.nz
Proudly Manufactured By:
P O Box 4043 Christchurch 8140 New Zealand
Phone 03 366 1796 Freephone 0800 3661796 Fax 03 366 1795
CORSAIR
Specifications, Installation and
Operating Instructions for the
FERVA Corsair Solid Fuel Burner
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
USB
2
Contents
PAGE
Testing and Certification 2
Dimensions 3
Clearances & Hearth 4
Installation Instructions 5
Minimum Flue Height 6
Flue Installation Details 6
HeatSaver Flue Kit Installation Instructions 6
Operation Instructions Wood 7 & 8
Caring for your Fire 9
Consumables 10
Creosote Formation 10
Storage of Fuel 11
Useful Tips 11
TEG Operating Instructions 12
Trouble Shooting 13 & 14
Warranty Details 15
Testing and Certification
MODEL
AS/NZS
2918:2001
AS/NZ
2918:2001, APP E
AS/NZS
4012:1999
AS/NZS
4013:1999
ECan Cert
Number
Corsair Complies N/A 71% 0.65g/kg 121490
3
Dimensions
4
Minimum Safe Installation Clearances
to COMBUSTIBLE Materials
Important Information
Clearances are with the 900mm
high factory flue shield fitted
Minimum floor protector material is
8mm tiles or thermal equivalent
Dimensions are in mm
5
Installation Instructions
This appliance should only be installed by a trained and NZHHA qualified installer.
Warning: the appliance and flue system shall be installed in accordance with AS/NZS 2918 and the appropriate requirements of
relevant building code/codes.
Warning: appliances installed in accordance with this standard shall comply with the requirements of AS/NZS 4013 where required by the regulatory authority, i.e. the appliance shall be identifiable by a compliance plate with the marking “Tested to AS/NZS 4013”.
Any modification of the appliance that has not been approved in writing by the testing authority is considered to be in breach of the approval granted for compliance with AS/NZS 4013.
Caution: mixing of appliance or flue system components from different sources or modifying the dimensional specification of com­ponents may result in hazardous conditions. Where such action is considered, the manufacturer should be consulted in the first in­stance.
Caution: cracked and broken components e.g. glass panels or ceramic tiles, may render the installation unsafe.
Maintain a clearance of at least 1 metre between front of the appliance and building structure or any other substantial im-
movable object.
Your appliance shall be seismically restrained, including the floor protector using the provided holes or brackets. The re-
straints should be sufficient enough to resist a seismic loading equal to 0.4 times the mass of the appliance. We recommend a minimum of 8mm dynabolts on concrete floors and 8mm coach screws for wooden floors of appropriate length.
Minimum Flue Height
The top of the flue system should be at least 600mm above the highest point of the roof ridgeline, if the point of intersection of the flue system and the roofline is less than 3 metres from the ridgeline horizon­tally.
If the point of intersection of the flue system and the roofline is greater than 3 metres horizontally, the top of the flue system shall be at least 1 me­tre above the point of intersection with the roof­line. (refer FIG 3)
These are considered to be minimum dimensions, and depending on local conditions,
taller flue system heights may be required for satisfactory performance.
Flue Installation Detail
Your Woodsman appliance should be installed with a HeatSaver Flue System.
A HeatSaver Flue System is available from all authorised Woodsman dealers throughout New Zealand.
The HeatSaver Flue System contains a complete installation drawing and correct clearances from the ceil­ing level up. Minimum clearances from the appliance to nearby combustible surfaces are given in FIGS 1 &
2.
Use of a flue system other than a genuine HeatSaver Flue System may affect the safety of the installa­tion, and may affect your warranty.
Insist on a genuine HeatSaver Flue System.