Harman Conquest Owner's Manual

Installation & Operating Manual
The Harman FireLuxe Direct Vent Gas Stove
With Top Cooking Burner System
WARNING: If the information in these
instructions is not followed exactly, a re or
explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
Report # 135-S-15-5
This appliance may be installed in
an aftermarket, permanently located
manufactured home (USA only) or in a mobile
home, where not prohibited by local codes.
This appliance is for use only with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases,
unless a certied conversion kit is used.
Ce manual est disponsible en Français sur demande.
R6
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d’essence ni
d’autres vapeurs ou liquides inammables dans
le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas
vous servir des téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre
fournisseur de gaz depuis un voisin. Suivezles instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incindie.
- L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien
qualié ou par le fournisseur de gaz.
Cet appareil peut être installé dans une maison
préfabriquée (mobile) déjà installée à demeure si kes règlements locaux le permettent.
Cet appareil doit être uniquement avec las type de gaz indiqué sur la plaque signalétique. Cet appareil ne peut être converti à d’autres gaz,
sauf si une trousse de conversion est utilisée.
Ne pas utiliser cet appareils’il a été plongé, meme partiellement, dans l’eau. Appeler un
technician qualié pour inspecter l’appareail et remplacer toute partie du système de commande et toute commande qui a été plongée dans /’eau.
Attention. Au moment de l’entretien des
commandes, étiquetez tous les ls avant de les débrancher. Des erreurs de la câblage peuvent entraîner un fonctionnement inadequate et
dangereux.
S’assurer que l’appareil fonctionne adéquatement
une fois l’entretien terminé.
AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place,
est craqué ou brisé. Conez le remplacement du panneau à un technician agree.
INSTALLATEUR: Laissez cette notice avec l’appareil.
COMSOMMATEUR: Conservez cette notice pour consultation ultérieur.
Table Of Contents
IMPORTANT SAFETY INFORMATION 4
SPECIFICATIONS 5
INSTALLATION 6
MASSACHUSETTS REQUIREMENTS 7
VENTING 8
ASSEMBLY 14
LIGHTING AND OPERATION 23
REMOTE CONTROL HANDSET OPERATION & PROGRAMMING 26
MAINTENANCE 28
WARRANTY 30
3
Important Safety Information
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Canadian Installation Code, CAN/CGA B149.
A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/BCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5kPa).
The installation must provide for adequate ventilation air to the appliance.
This gas appliance must not be connected to a chimney ue serving a separate solid-fuel burning appliance.
The appliance, when installed, must be electrically grounded in accordance with local codes, or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22. 1.
When the appliance is installed directly on carpeting or non-ceramic tile or other combustible material other
than wood ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. A commercially available hearth pad meets this requirement.
The appliance area must be kept clear and free from combustible materials, gasoline and other ammable vapors and liquids.
The ow of combustion and ventilation air must not be obstructed.
Do not use this appliance if any part has been under water. Immediately call a qualifed service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Due to high temperatures, the appliance should be located out of trafc and away from furniture and
draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other ammable material should not be placed on or near the appliance.
Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
Installation and repair should be done by a qualied service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartments,
burners and circulating air passageways of the appliance be kept clean.
WARNING: Do not operate the appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a qualied service person.
WARNING: Use only replacement glass, part number 3-40-21001500 and glass gasket, part number 3-44-00539. Do not use substitute materials. Do not strike or slam the glass front. Do not use abrasive cleaners. Do not clean when hot.
4
Specications
MAIN BURNER Natural Gas Propane (LP) Input Rating-Btu/hr 36000 36000 Min. Input-Btu/hr 23000 23000 Orice-DMS #34 #50
COOKING BURNER
Input Rating-Btu/hr 12000 12000 Min. Input-Btu/hr 3500 3500 Orice-DMS #52 #58
GAS SUPPLY
Manifold Pressure 4.5”w.c./1.1kPa 10.0”w.c./2.5kPa Min. Supply Pressure 5.0”w.c./1.3kPa 11.0”w.c./2.8kPa Max. Supply Pressure 10.0”w.c./2.5kPa 13.0”w.c./3.3kPa Annual Fuel Utilization Efciency (AFUE) 72.7% 74.9% Steady State Efciency 73.4% 75.6%
It is recommended that the pilot ame be turned off if the appliance will not be in use for an extended pe-
riod of time.
This appliance is equipped for use with the fuel type indicated on the rating plate. Fuel conversion kits that
include the necessary parts and instructions are available from your installer, dealer or Harman Stove Co.
This appliance has been certied by OMNI-Test Laboratories, Inc. to ANSI Z21.88-2005 • CSA 2.33-2005 Vented Gas Fireplace Heaters and CAN1-2.17-M91, Gas-Fired Appliances for Use At High Altitudes.
The FireLuxe is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having jurisdiction for gas product installations to determine their specic requirements for
high altitude installations.
28” (71 cm)
20½” (52 cm)
30½” (77.5 cm)
5
23¼” (59 cm)
Installation
Several issues must be addressed when selecting a suitable location for your FireLuxe. The minimum clearances to combustible construction are listed below. In addition, access to the gas supply and electrical
supply must be considered. The location of the stove will also affect the venting requirements and you must be certain the location will allow compliance with the venting requirements shown on pages 8 – 13. You must also insure that your installation provides adequate accessibility clearance for servicing and proper
operation.
When the appliance is installed directly on carpeting or tile or other combustible material other than wood
ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the
appliance.
Installation and repair should be done by a qualied service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartments,
burners and circulating air passageways of the appliance be kept clean.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
Stove to Left Side Wall 6” (150mm) Stove to Corner Wall 6” (150mm) Stove to Right Side Wall 6” (150mm) Stove to Ceiling 30” (760mm) Stove to Rear Wall 6” (150mm) Stove to 10” Deep Mantel 30” (760mm) Max. Alcove Depth 24” (610mm)
A = 6” (150 mm) B = 6” (150 mm) C = 6” (150 mm) D = 24” (610 mm) Max. Alcove Depth
C
A
Sidewalls
E = 6” (150 mm)
E
F = 30” (760 mm) G = 30” (760 mm) H = 10” (250 mm) Max.
D
B
H
F
G
E
Corner
Ceiling
Mantel
6
Installation
NOTE: If you will be installing the optional warming shelves, make sure to plan for the additional width that they occupy. For the details, see the information included with the warming shelf kit. The gas stove is shipped with a exible connector that has a 1/2” NPT female connection. The gas supply piping should have a separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve.
The stove and its main control valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The stove must be isolated
from the gas supply piping system by closing the main control valve during any pressure testing of the
gas supply system at test pressures equal to or less than 1/2 psi (3.5 kPa). After the gas supply has been connected, apply a soapy water solution to all the ttings to check for gas leaks. Never use a ame to test for leaks.
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed plumber or gas tter when installed within the Commonwealth
of Massachusetts. If this appliance is installed in a dwelling, building or structure used in whole or in part for residential purposes and the installation includes a horizontal vent termination that is less than seven
(7) feet above the nished grade in the area of the venting, including but not limited to decks and porches, a hard-wired carbon monoxide detector with an alarm and battery back-up must be installed on the oor
level of the dwelling, building or structure where the appliance is to be installed.
Additionally, a hard-wired or battery operated carbon monoxide detector with an alarm must be installed on each additional level of the dwelling, building or structure served by the appliance. It shall be the
responsibility of the property owner to secure the services of qualied licensed professionals for the
installation of hard-wired carbon monoxide detectors.
In the event that the horizontally vented appliance is installed in a crawl space or attic, the hardwired
carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor level.
In the event that this requirement cannot be met at the time of completion of the installation of the appliance, the owner shall have a period of thirty (30) days to comply with the requirement. However, during said thirty (30) day period, a battery operated carbon monoxide detector with alarm must be installed.
Each carbon monoxide detector as required in accordance with the above provisions must comply with NFPA 720 and be ANSI/UL 2034 and IAS certied.
In addition, when the stove is horizontally vented and the vent termination is less than seven (7) feet above nished grade a metal or plastic identication plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS”.
A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH INCLUDE PARTS LISTS, AND/OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN WITH THE STOVE AT
THE COMPLETION OF THE INSTALLATION.
ATTENTION INSTALLERS: Mark below which venting system was used in the installation. These
instructions must remain with the FireLuxe Installation & Operation Manual.
Simpson DuraVent GS AmeriVent Direct Security Secure Vent Selkirk DT Excel Direct
7
Venting
The FireLuxe Gas Stove has been tested and listed for installation with 4” X 6 5/8” Simpson DuraVent GS, AmeriVent Direct, Security Secure Vent, ICC Excel Direct and Selkirk DT direct venting components. The total vent length may not exceed 40 feet, including vertical rise and horizontal run. The vent lengths are measured from the stove, not the oor. The minimum vertical rise required is 2 feet. The maximum allowed horizontal vent run is 20 feet when the venting includes at least 5 feet of vertical rise. The maximum allowed horizontal
vent run for vertical rises of less than 5 feet is shown in the venting charts. No more than three elbows may be used in any installation. The venting charts include the use of one elbow. For the second or third elbows that are included in the installation, add 4 feet to the actual horizontal run for each elbow to determine the
equivalent horizontal run for the installation.
The venting charts allow a simple way to determine the recommended initial settings for both the air inlet and exhaust restrictors. These settings have been determined by extensive testing and will be a good starting
point while setting up the stove. Small adjustments from these settings may be needed to account for specic installation variables. Please see the instructions on pages 21 - 22 for how to adjust the restrictors.
The letters (A-E) designate the position of the air inlet restrictor. When ½ is added to the letter designation, this indicates that the position is halfway between adjacent letters. The numbers (0-8) indicate the position of the exhaust restrictor. When ⅛, ¼, ⅜, ½, or ¾ is added to the number designation, this indicates that the position is fractionally between adjacent numbers. For example, 5¼ is one-fourth the way between 5 and 6.
To use the charts, determine the horizontal run length and vertical rise length (in feet) for your installation.
If more than one elbow is used, add 4 feet to the actual horizontal run length for each additional elbow to
get the equivalent horizontal run for the chart. Note: Remember that a maximum of three elbows is allowed. Select the venting chart for the fuel type (Natural Gas or Propane (LP) Gas) and nd the box on the chart that corresponds to the vertical rise and actual horizontal run (or equivalent horizontal run, if two or three elbows are used) and read the settings for the inlet air restrictor (A-E) and exhaust restrictor (0-8). Examples are shown below and on page 9.
The FireLuxe is shipped with a Simpson DuraVent GS starter section that is specically designed for the
FireLuxe. Regardless of the venting brand you chose, you must use the provided DuraVent starter section. All of the venting brands listed for use with the FireLuxe are compatible with the provided starter section. For venting system installation details, refer to the instructions provided with the venting system you have chosen.
Each brand has specic installation requirements that must be followed to insure a safe and functional venting
system for your FireLuxe.
Note: The FireLuxe is shipped from the factory with restrictor settings for 2 feet of vertical rise and 1 foot
of horizontal run and for the fuel type listed on the rating plate attached to the rear of the stove.
Example 1
Fuel = Propane (LP)
Vertical Rise = 15 feet Horizontal Run = 8 feet
Elbows = 1 (one) Equivalent Horizontal Run = 8 feet
Exhaust
Air Restrictor Setting = E½ Exhaust Restrictor Setting = 6¾
Inlet Air
8
Example 2
Fuel = Propane (LP)
Vertical Rise = 6 feet Horizontal Run = 8 feet
Elbows = 3 (three) Equivalent Horizontal Run = 16 feet (8+4+4)
Air Restrictor Setting = C
Exhaust Restrictor Setting = 3
Example 3
Venting
3
Exhaust
C
Inlet Air
Fuel = Natural Gas
Vertical Rise = 22 feet Horizontal Run = 0 feet Elbows = 0 (none) Equivalent Horizontal Run = 0 feet
Air Restrictor Setting = E½ Exhaust Restrictor Setting = 7⅜
Example 4
Fuel = Propane (LP) Vertical Rise = 12 feet
Horizontal Run = 4 feet
Elbows = 1 (one) Equivalent Horizontal Run = 4 feet
Exhaust
7⅜
Inlet Air
Exhaust
Air Restrictor Setting = E½ Exhaust Restrictor Setting = 6½
Inlet Air
9
Venting
Natural Gas Venting
IF YOUR VENTING CONFIGURATION
FALLS ABOVE THIS DOTTED LINE,
SEE PAGE 12
Horizontal Run - In Feet
Vertical Rise - In Feet
10