3 HP rated
Pump StageSingle
Air Outlet Size1/4” - 18 NPT
Shipping Weight152 Pounds
Power Cord10’ - Electrical Plug Sold Separately
SAVE THIS MANUAL
You will need this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures, parts list and assembly
diagram. Keep your invoice with this manual. Write the invoice number on the inside
of the front cover. Keep this manual and invoice in a safe and dry place for future reference.
GENERAL SAFETY WARNINGS AND PRECAUTIONS
KEEP WORK AREA CLEAN AND DRY. 1. Cluttered, damp, or wet work areas invite
injuries.
KEEP CHILDREN AWAY FROM WORK AREA. 2. Do not allow children to handle
this product.
STORE IDLE EQUIPMENT. 3. When not in use, tools and equipment should be
stored in a dry location to inhibit rust. Always lock up tools and equipment, and
keep out of reach of children.
DO NOT USE THIS PRODUCT IF UNDER THE INFLUENCE OF ALCOHOL OR 4.
DRUGS. Read warning labels on prescriptions to determine if your judgement or
reexes are impaired while taking drugs. If there is any doubt, do not attempt to
use this product.
USE EYE, HAND, AND HEARING PROTECTION. 5. Wear ANSI approved safety
impact goggles, hearing protection, and heavy-duty work gloves when using this
product.
DRESS SAFELY. 6. Do not wear loose clothing or jewelry, as they can become
caught in moving parts. Wear a protective hair covering to prevent long hair from
becoming caught in moving parts. If wearing a long-sleeve shirt, roll sleeves up
above elbows.
DO NOT OVERREACH.7. Keep proper footing and balance at all times to prevent
tripping, falling, back injury, etcetera.
REV 05j; 07f; 09a
SKU 93271 For technical questions, please call 1-800-444-3353. PAGE 2
INDUSTRIAL APPLICATIONS MUST FOLLOW OSHA REQUIREMENTS.8.
STAY ALERT.9. Watch what you are doing at all times. Use common sense. Do
not use this product when you are tired or distracted from the job at hand.
CHECK FOR DAMAGED PARTS.10. Before using this product, carefully check that
it will operate properly and perform its intended function. Check for damaged parts
and any other conditions that may affect the operation of this product. Replace or
repair damaged or worn parts immediately.
REPLACEMENT PARTS AND ACCESSORIES:11. When servicing, use only identi-
cal replacement parts. Only use accessories intended for use with this product.
Approved accessories are available from Harbor Freight Tools.
MAINTAIN THIS PRODUCT WITH CARE.12. Keep this product clean and dry for
better and safer performance.
MAINTENANCE:13. For your safety, service and maintenance should be performed
regularly by a qualied technician.
USE THE RIGHT TOOL FOR THE JOB.14. Do not attempt to force a small tool or
attachment to do the work of a larger industrial tool. There are certain applications
for which this tool was designed. It will do the job better and more safely at the
rate for which it was intended. Do not modify this tool, and do not use this tool for
a purpose for which it was not intended.
The warnings, precautions, and instructions discussed in this manual cannot cover 15.
all possible conditions and situations that may occur. The operator must under-
stand that common sense and caution are factors, which cannot be built into this
product, but must be supplied by the operator.
SPECIFIC PRODUCT WARNINGS AND PRECAUTIONS
CAUTION: 1. Fill the Air Compressor with a premium quality, 30-weight, non-deter-
gent oil before each use. Running the Air Compressor with no oil or low oil will
cause damage to the equipment.
Note: The oil reservoir has an optimal capacity of 30 ounces of oil.
MAKE SURE ALL TOOLS AND EQUIPMENT USED WITH THE AIR COMPRES-2.
SOR ARE RATED TO THE APPROPRIATE CAPACITY. Do not use any tool or
equipment that does not operate at or above the PSI that the compressor’s regula-
tor is set to.
DRAIN AIR COMPRESSOR EVERY DAY.3. Do not allow moisture to build up inside
the Air Compressor. (See“INSPECTION, MAINTENANCE, AND CLEANING”
section of this manual.)
MAINTAIN A SAFE WORKING ENVIRONMENT. 4. Keep the work area well lit.
Make sure there is adequate surrounding workspace. Always keep the work area
SKU 93271 For technical questions, please call 1-800-444-3353.PAGE 3
free of obstructions, grease, oil, trash, and other debris. Do not use the Air Com-
pressor in areas near ammable chemicals, dusts, and vapors.
AVOID INJURY:5. Never direct the pressurized air stream at people or animals.
DO NOT ALTER OR REMOVE THE FACTORY SEALED PRESSURE RELEASE 6.
VALVE (5A). (See Assy. Diagram A.)
DO NOT OPEN THE WATER DRAIN VALVE (10A) SO THAT 7. MORE THAN
FOUR THREADS ARE SHOWING. (See Assy. Diagram A.)
AN EXTENSION CORD MUST 8. NEVER BE USED WITH THIS ITEM. Connecting
this item to an outlet through an extension cord MAY CAUSE ELECTRICAL
DAMAGE TO THE MOTOR and could present a FIRE HAZARD. Longer air
hoses are typically safer and more effective than extension cords.
THIS UNIT REQUIRES A 230 V~, UL LISTED, TWISTLOCK PLUG (SOLD SEPA-9.
RATELY) TO BE INSTALLED BY A QUALIFIED ELECTRICIAN BEFORE SETUP
OR USE.
THIS COMPRESSOR MAY REQUIRE A DEDICATED ELECTRICAL CIRCUIT AS 10.
THE AMPERAGE DRAW UNDER FULL LOAD COMBINED WITH USE OF ANY
OTHER ITEM MAY OVERLOAD YOUR CIRCUIT.
WARNING: 11. This product contains or produces a chemical known to the State of
California to cause cancer and birth defects (or other reproductive harm).
(California Health & Safety Code § 25249.5, et seq.)
People with pacemakers should consult their physician(s) before use. Electromag-12.
netic elds in close proximity to heart pacemaker could cause pacemaker interfer-
ence or pacemaker failure.
REV 07f
SKU 93271 For technical questions, please call 1-800-444-3353. PAGE 4