Harbor Freight Tools 63402, 63401 Owner's Manual

Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
63402
Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference. 17j
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright© 2016 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
To ol s re q u ir e d f o r a s s e mb l y a n d s e r vi c e m a y n o t b e in c l ud e d .
Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.
Page 2 For technical questions, please call 1-888-866-5797. Item 63401 63402
Before start-up, note the following:
The pump must be connected to a GFCI protected plug which has been installed according
to regulations. The plug must have a supply voltage of 120 VAC at 60 Hz.
CAUTION
This pump has been evaluated for use with fresh water only.
WARNING
IMPORTANT! For your own safety – before starting to run the pump, please have the following items checked by an expert:
1. Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
2. Risk of electric shock – This pump has not been investigated for use in swimming pool areas.
3. The electrical connections must be protected from moisture.
4. If there is danger of flooding, the electrical connections must be taken to higher ground.
5. Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
6. The pump must be protected from frost.
7. The pump must be protected from running dry.
8. Access by children should also be prevented with appropriate measures.
9. To reduce the risk of electric shock, use only on portable self-contained fountains.
10. POSITION OF PUMP:
To avoid the possibility of the pump plug or receptacle getting wet, position pump to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug. The user should arrange a “drip loop” in the cord connecting the pump to a receptacle.
Pump
The “drip loop” is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water traveling along the cord and coming in contact with the receptacle.
11. To prevent death from electric shock,
pump must be connected only to a GFCI protected outlet.
12. Do not use an extension cord with this item.
13. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
14. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
Fluid Type
The Pump is designed for use with fresh water with a maximum temperature of 95° F (35°C) — do not use for
heated liquids. Do not use the Pump for other fluids, especially not fuels, cleaning fluids, or other chemical products. Do not use to pump salt water, highly chlorinated water, or water with a high pH level.
Page 3For technical questions, please call 1-888-866-5797.Item 63401 63402
Specifications
63401 63402 Electrical Rating 120 VAC / 60 Hz / 1.3 A 120 VAC / 60 Hz / 2.45 A Power Cord Length 16' 16' Maximum Flow @ 0' 2500 GPH 4500 GPH Maximum Head lift @ 0 Flow 19' 23' Discharge Port 1/2" NPT Thread 2" NPT Thread
Installation
The submersible motor pump must be installed in a stationary position with either:
a. A fixed pipeline or
b. A flexible hose pipe.
6 FT. minimum
6 IN. minimum
1. Submerge the pump under water to prevent the pump from taking in air.
2. The pond must be at least 6 feet away from the receptacle.
3. To reduce wear on the pump, place the pump on a platform above mud, sand, small rocks, and other debris.
4. If running with fountain jets, the pump must be
mounted firmly and horizontally on a platform.
5. Connect a discharge hose (not included) to the Hose Adapter (3).
6. Connect the free end of the discharge hose to a waterfall basin, or similar device (none included).
Please note!
1. Do not install the pump by suspending it unsupported from its delivery pipe or power cord. The pump must be suspended from the handle or be placed on the bottom of the basin. To ensure that the pump works properly, keep the bottom free from sludge and dirt of all kinds.
2. If the water level sinks too low, any sludge in the basin will dry out and stop the pump from starting. To help ensure the pump will start as required, check the pump regularly with start-up tests.
Power Supply
1. The Pump is equipped with a shock­proof plug according to regulations. The Pump is designed to be connected to a
120 VAC, 60 Hz GFCI protected socket.
2. Make sure that the socket is sufficiently secured and is in excellent condition.
3. When the plug is inserted into the socket, the pump will be on standby.
4. WARNING: To prevent death from electric
shock, pump must be connected only to a GFCI protected outlet.
WARNING! If the power cord or plug is damaged,
do not use the pump. The power cord or plug may only be repaired by a certified electrician.
WARNING! Pump must be positioned with a drip loop, as discussed under WARNING.
Areas of use
1. This pump is designed to pump fresh water only.
2. This pump is designed to be used for:
An area not used for swimming.