Harbor Breeze E-BE44AN5C, E-BE44MWW5C, E-BE44PPW5C, E-BE44AB5CS, E-BE44ABZ5C Installation Manual

ITEM #0096879
0096950 0096982 0205233
SOS ITEM #0018035
Harbor Breeze® is a registered trademark of LF, LLC. All Rights Reserved.
BELLEVUE CEILING FAN
MODEL #E-BE44ABZ5C
E-BE44AN5C
E-BE44MWW5C
E-BE44PPW5C
E-BE44AB5CS
Federal regulations require ceiling fans with light kits manufactured or imported after January 1, 2009, to limit total wattage consumed by the light kit to 190W. Therefore, this fan is equipped with a wattage limiting device.
ATTACH YOUR RECEIPT HERE
Serial Number
Questions, problems, missing parts? Before returning to your retailer, call or contact our customer service department at 1-800-527-1292, 8:30 a.m. - 5:00 p.m., CST, Monday - Friday.
E124404
Purchase Date
1
TABLE OF CONTENTS
Safety Information .....................................………………………………………………...…
….....
Product Overview ...........................................................................................................................4
2 - 3
Package Contents .....……………………………………………………………..….
Hardware Contents ...................................................................................................................
….
.........
......
......
Preparation ...............….…………………..……………………….…………….……………….......6
Initial Installation ............….……………..……………………….……….
…..….
.............................7 - 8
Downrod Style Fan Mounting ............................................................................................8 - 10
Closemount Style Fan Mounting
.
...........................................................................................10 - 11
Wiring .................................……………………........................................…………...........12 - 13
Final Installation ….…………….……………………….…………….……..........
Operation Instructions ............................................................……………………
Care and Maintenance …
….…
…………………………………………………..….......
Troubleshooting .............………...………………………….……………..………....
Warranty ……………………………….…………………………………………..…
.....….......
………............
..............
…........18 - 19
….
.........
14 - 16
16 - 18
18
........
20
5 6
Replacement Parts List ...........................................................................................
.........
...................
21
SAFETY INFORMATION
READ AND SAVE THESE INSTRUCTIONS Please read and understand this entire manual before attempting to assemble, install or operate the product. If you have any questions regarding the product, please call customer service at 1-800-527-1292, 8:30 a.m. - 5:00 p.m., CST, Monday - Friday.
• Do not discard fan carton or foam inserts. Should this fan need to be returned to the factory for repairs, it must be shipped in its original packaging to ensure proper protection against damage that might exceed the initial cause for return.
Make sure that all electrical connections comply with local codes, ordinances, the National Electrical
Code and ANSI/NFPA 70-1999. Hire a qualified electrician or consult a do-it-yourself wiring handbook (available at Lowe's) if you are unfamiliar with installing electrical wiring.
Make sure the installation site you choose allows a minimum clearance of 7 feet from the blades to
the floor and at least 30 in. from the end of the blades to any obstruction.
After you install the fan, make sure that all connections are secure to prevent the fan from falling.
• The net weight of this fan including the light kit is: 14 lbs. (6.35 kg).
2
SAFETY INFORMATION
WARNINGS
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box
marked "ACCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
When mounting fan to a ceiling outlet box, use a METAL octagonal outlet box. Secure the outlet box directly to the building structure. The outlet box and its support must be able to support the moving weight of the fan (at least 35 lbs.). Do NOT use a plastic outlet box.
To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.
To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only one 12-gauge house wire and two lead wires from the fan. If your house wire is larger than 12-gauge or there is more than one house wire to connect to the two fan lead wires, consult an electrician for the proper size wire connectors to use.
To reduce the risk of fire or electrical shock, do not use the fan with any solid state speed control device or control fan speed with a full range dimmer switch.
To reduce the risk of fire, electrical shock, or personal injury, do not bend the blade arms when installing them, balancing the blades, or cleaning the fan. Do not insert objects between the rotating fan blades.
To reduce the risk of personal injury, use only parts provided with this fan. The use of parts
OTHER than those provided with this fan will void the warranty.
CAUTIONS
Before proceeding, be sure to shut off electricity at main switch or circuit breaker in order to avoid electrical shock.
Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
3
PRODUCT OVERVIEW
Congratulations on your purchase of this Harbor Breeze® Ceiling Fan! This product has been specifically designed to give you all the performance you’ll ever need. Harbor Breeze® is the perfect fusion of smart innovation and beautiful style. Designed for more than just air movement, our products are built to function flawlessly... day after day. Expect showroom quality at an exceptional price with Harbor Breeze® - available exclusively at Lowe’s.
Harbor Breeze® is a registered trademark of LF, LLC. All Rights Reserved.
Determining how you want your ceiling fan to look and operate is an important step prior to installation. You can save installation time by deciding which options are best suited for your needs before beginning the steps outlined in this manual.
Your fan can be installed with or without a downrod.
• Downrod-style mounting is best suited for ceilings 8 ft. (2.44 m) high or higher. For taller ceillings you may want to use a longer downrod (sold separately) than the one provided.
• Angle-style mounting is best suited for angled or vaulted ceilings. A longer downrod is sometimes necessary to ensure proper blade clearance.
• Closemount-style mounting is more suitable for ceilings lower than 8 ft. (2.44 m) high. Your fan also has multiple wiring options available, including:
• Fan and light controlled by pull chain.
• Fan controlled by pull chain, light controlled by wall switch.
• Fan and light controlled by two separate wall switches. Your fan is remote control adaptable (remote control sold separately).
4
PACKAGE CONTENTS
Q
D
C
O
R
A
P
B
E
N
S
M
G
H
F
L
PART DESCRIPTION QUANTITY
A Downrod B C D
Canopy 1 Mounting Bracket
Motor Housing 1 E Yoke Cover F Light Kit Fitter G
Blade 5
H Blade Arm 5
1
1
1 1
I Glass Shade 3 J
IMPORTANT REMINDER: You must
Candelabra Base Bulb 3
use the parts provided with this fan for proper installation and safety.
I
J
K
PART DESCRIPTION QUANTITY
K Pull Chain Extension 2
L Socket Ring (preassembled) 3
M Motor Screw 10 (preassembled)
N Lock Washer 10 (preassembled)
O Canopy Mounting Screw 4 (preassembled)
P
Pin (preassembled) 1 Q Clip (preassembled) 1 R
Star Washer
4
(preassembled) S Fitter Plate Screw 3
(preassembled)
5
HARDWARE CONTENTS (shown actual size)
AA
Blade Screw
Qty. 15
BB CC
Fiber Blade Washer
E3 Wire Connector
Qty. 15
Qty. 4
PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package
contents list and hardware contents above. If any part is missing or damaged, do not attempt to assemble, the product. Contact customer service for replacement parts.
Estimated Assembly Time: 120 minutes
Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers
Helpful Tools (not included): AC Tester Light, Tape Measure, Do-It-Yourself-Wiring Handbook (available at Lowe’s) and Wire Cutters
Bulbs Required (included): 3 candelabra-base 60-watt max. bulbs
DANGER: When using an existing outlet box, make sure the outlet box is securely attached to
the building structure and can support the full weight of the fan. Failure to do this can result in serious injury or death. The stability of the outlet box is essential in minimizing wobble and noise in the fan after installation is complete.
CAUTION: Be sure outlet box is properly grounded and that a ground wire (green or bare) is present.
After opening top of carton, remove mounting hardware package from foam inserts. Remove motor from packing and place on carpet or on foam to avoid damage to nish.
CAUTION: Carefully check all screws, bolts and nuts on fan motor assembly to ensure that they are secured.
6
INITIAL INSTALLATION
1.
Turn off circuit breakers and wall switch to the fan supply line leads. (Fig. 1)
DANGER: Failure to disconnect power supply prior to installation may result in serious injury or death.
Determine mounting method to use. (Fig. 2)
2. A. Downrod mount (normal or angled ceiling) B. Closemount (normal ceiling only) Important: If using the angle mount, check to make sure the ceiling angle is not steeper than 19°.
1
2
ON
ON
OFF
OFF
Check to make sure blades (G) are at least 30 in.
3. from any obstruction. Check downrod (A) length to ensure blades (G) are at least 7 ft. above the floor. (Fig. 3)
3
G
A
B
30 in.
min.
7 ft. min.
7
INITIAL INSTALLATION
Secure mounting bracket (C) to outlet box using
4. screws, spring washers, and flat washers provided with the outlet box. (Fig. 4) *NOTE: It is very important that you use the
proper hardware when installing the mounting bracket (C) as this will support the fan.
4
IMPORTANT: If using the angle mount, make
sure open end of mounting bracket (C) is installed facing the higher point of the ceiling.
5.
Remove motor screws (M) and lock washers (N) from underside of motor housing (D). Note: Use opening in fitter plate for easy access to motor screws (M). [If there are plastic motor blocks installed with the motor screws (M) and lock washers (N), discard the plastic motor blocks.] (Fig. 5)
Follow mounting instructions on pages 8 - 10 for “Downrod Style Fan Mounting” or proceed to pages 10 and 11 for “Closemount Style Fan Mounting”, depending on mounting method (A or B) chosen in Step 2 on previous page.
5
2
C
M
N
Fitter Plate
DOWNROD STYLE FAN MOUNTING
Remove pin (P) and clip (Q) from downrod (A).
1. (Fig. 1A)
Partially loosen set screws in motor housing yoke at top of motor housing (D). (Fig. 1B)
*Helpful Hint: Downrod style mounting is best suited for ceilings 8 ft. (2.44 m) high or higher. For taller ceilings you may want to use a longer downrod (sold separately) than the one provided. Angle style mounting is best suited for angled or vaulted ceilings. A longer downrod is sometimes necessary to ensure proper blade clearance.
D
1A 1B
2
A
Q
P
Set Screw
D
8
DOWNROD STYLE FAN MOUNTING
2.
Insert downrod (A) through canopy (B) and yoke cover (E). Thread wires from motor housing (D) through downrod (A). (Fig. 2)
3.
Slip downrod (A) into motor housing yoke, align holes and re-install pin (P) and clip (Q). Re-tighten set screws in motor housing yoke and then tighten nuts. Slide yoke cover (E) down until it rests on top of motor housing (D). (Fig. 3)
2
A
B
E
3
E
Depending on the length of downrod (A) you use,
4. you may need to cut the lead wires back to simplify the wiring. If you decide to cut back the lead wires, it is suggested that you do so in the following manner:
Take the lead wires and make sure that you have pulled them all the way through the top of the downrod (A). Start at the TOP of the ball on the downrod (A) and measure 8 in. of lead wire, and then cut the excess wire off with wire cutters. (Fig. 4)
4
Q
A
P
D
Ball
A
Note: If you do not cut back the lead wires,
Steps 4 and 5 are not necessary and you may proceed to Step 6 instead.
9
DOWNROD STYLE FAN MOUNTING
5.
If you decided to cut back the lead wires in Step 4, strip 1/2 in. of insulation from end of white wire. Twist stripped ends of each strand of wire within the insulation with pliers. (Fig. 5) Repeat Step 5 for black, blue (if applicable) and green wires.
6.
Install ball end of downrod (A) into mounting bracket (C) opening. Align slot in ball with tab in mounting bracket (C). (Fig. 6)
5
6
DANGER: Failure to align slot in ball with tab may result in serious injury or death.
Continue to “Wiring” instructions on page 12.
CLOSEMOUNT STYLE FAN MOUNTING
Remove canopy cover from bottom of canopy (B).
1. [Note: It may be necessary to use the handle end of a screwdriver to remove the canopy cover by tapping on the canopy cover from the inside of the canopy.] (Fig. 1)
*Helpful Hint: Close style mounting is more suitable for ceilings lower than 8 ft. (2.44 m) high. The downrod (A), hanging ball, yoke cover (E), and canopy cover are not used in this type of installation.
1
A
C
Tab
Hanging Ball Slot
B
Canopy Cover
10
CLOSEMOUNT STYLE FAN MOUNTING
If necessary, remove every other screw and lock
2. washer from top of motor housing (D). (If there are only three screws and lock washers in top of motor housing (D), the other three screws and lock washers will be located in one of the hardware packs.) (Fig. 2)
3.
Pull wires through hole in the middle of the canopy (B) and attach canopy (B) to motor housing (D) using the three screws and three lock washers refered to in Step 2 above. (Fig. 3)
2
D
3
B
4.
Hang motor housing (D) on the tab on the mounting bracket (C) using one of the non-slotted holes in the canopy (B). (Fig. 4)
D
4
B
Tab
C
D
11
WIRING
WARNING: To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only one 12-gauge house wire and two lead wires from the fan. If your house wire is larger than 12-gauge or there is more than one house wire to connect to the two fan lead wires, consult an electrician for the proper size wire connectors to use.
CAUTION: Be sure outlet box is properly grounded and that a ground (green or bare) wire is present.
WARNING: If house wires are different colors than referred to in the following steps, stop immediately. A professional electrician is recommended to determine wiring.
Choose wiring diagram (Fig. 1A, Fig. 1B or Fig. 1C)
1. that fits your situation and make appropriate wiring
connections as follows: [NOTE: For each wire connection below, use one of the wire connectors (CC) provided, making sure to screw wire connector (CC) on in a clockwise direction.]
FAN AND LIGHT CONTROLLED BY PULL CHAINS
1A
120 V Power
FROM
CEILING
BLACK
WHITE GROUND/GREEN (BARE)
1A. FAN AND LIGHT CONTROLLED BY PULL CHAINS: Connect BLACK and BLUE wire from
fan to BLACK wire from ceiling. Connect WHITE wire from fan to WHITE wire from ceiling. Connect all GROUND (GREEN) wires together from fan (on downrod (A) and mounting bracket (C)) to BARE/GREEN wire from ceiling. (Fig. 1A)
1B. FAN CONTROLLED BY PULL CHAIN, LIGHT BY WALL SWITCH: If you intend to control the fan light with a separate wall switch, connect BLACK wire from fan to BLACK wire from ceiling. Connect BLUE wire from fan to the BLACK wire from the independent wall switch for the light. Connect WHITE wire from fan to WHITE wire from ceiling. Connect all GROUND (GREEN) wires together from fan (on downrod (A) and mounting bracket (C)) to BARE/GREEN wire from ceiling. (Fig. 1B)
WHITE
GREEN
BLACK
FAN
GREEN
FAN CONTROLLED BY PULL CHAIN, LIGHT BY WALL SWITCH
1B
120 V Power
FROM
CEILING
BLUE
BLACK
BLUE
WHITE
FROM FAN
BLACK
BLACK (WALL SWITCH)
WHITE
GROUND/GREEN (BARE)
WHITE
GREEN
12
FAN
GREEN
FROM FAN
WHITE
WIRING
1C. FAN AND LIGHT CONTROLLED BY TWO WALL SWITCHES: If you intend to
control the fan and light with separate wall switches, connect BLACK wire from fan to BLACK wire from the independent wall switch for the fan. Connect BLUE wire from fan to the BLACK wire from the other independent wall switch for the light. Connect WHITE wire from fan to WHITE wire from ceiling. Connect all GROUND (GREEN) wires together from fan (on downrod (A) and mounting bracket (C)) to
BARE/GREEN wire from ceiling. (Fig. 1C)
NOTE: Black wire is hot power for fan. Blue wire
is hot power for light kit. White wire is common for fan and light kit. Green or bare wire is ground.
Wrap electrical tape around each individual wire
2. connector (CC) down to the wire as shown in Fig. 2.
FAN AND LIGHT CONTROLLED BY TWO WALL SWITCHES
1C
120 V Power
FROM
CEILING
BLACK
FAN
GREEN
BLACK (WALL SWITCH)
BLACK (WALL SWITCH FOR LIGHT)
WHITE
GROUND/GREEN (BARE)
BLUE
GREEN
FROM FAN
WHITE
WHITE
2
WARNING: Make sure no bare wire or wire strands are visible after making connections. Place green and white connections on opposite side of box from the black and blue (if applicable) connections.
Turn spliced/taped wires upward and gently push wires and wire connectors (CC) into outlet box.
Hardware Used
CC
E3 Wire Connector x4
3.
IMPORTANT: Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan. To reduce the risk of fire or electrical shock, do NOT use a full range dimmer switch to control fan speed. (Fig. 3)
3
CC
CC
3 2
1
CC
CC
13
Dimmer Switch
Speed Switch
For illustrative purposes only--not
intended to cover all types of controls
Loading...