HAPRO Luxura V6, Luxura V8 User Manual

USER
MANUAL
2
3
Congratulations on the purchase of your Hapro appliance. Your new appliance has been manufactured with the utmost care and attention and consists of high-quality parts. All Hapro appliances have been developed to give you the best possible tan, whilst complying with the strictest applicable European standards. (original instructions )
Lamp information............................................4
Operation ..................................................5
Symbols ...................................................14
Warranty policy.............................................15
Declaration of Confirmity .....................................16
Contents
This manual provides the required information on warnings, instructions and assembly. You should use this manual for more than just the necessary appliance assembly and/or maintenance instructions; you need to familiarize yourself with all of the information provided. Persons who use the tanning appliance need to be informed and supervised, and it is your duty to make sure they receive proper assistance. Digital version at www.hapro.com.
4
Model : XXXXX Type : XXXXXXXX Serial number : XXXXXXXXXX / 3 Rated voltage : XXXXXXXX Rated power input : XXX W
Manufactured by: Hapro International B.V. PO Box 73 4420 AC Kapelle, Netherlands
XXXXX_XX
UV type 3 (Total Erythema output limited at 0,3W/m3)
48 x maxlight XL 120W-R CE III 120-R-(27-36)/(2,8-3,8)
Ballast: 200W
Lamp information
The lamps listed below are those that are installed as standard equipment at the factory. These standard lamps have been selected for optimal tanning results and to match the UV classi cation of your tanning unit. We recommend that when you replace a lamp you only use lamps of the type currently installed in your tanning unit and which are listed in the table below and on the identi cation plate. If you choose to install a di erent type of lamp, you must only use lamps that are marked with an equivalent code which indicates that the UV component falls within the equivalence range listed on the identi cation plate
Note: • The equivalent code is only applicable to low-pressure  uorescent lamps.
• The total erythema is limited to 0.3 W/m².
Example:
On the example identifi cation plate the equivalent codes for the installed lamps are circled.
The equivalent code for the canopy is 120-R-(27-36)/(2,8-3,8) 120 = the wattage of the lamp R = the re ector type (27-36) = the equivalence range for the total e ective erythema (2,8-3,8) = the equivalence range for the NMSC ratio
If you intend to install a new lamp, the wattage and re ector type must always match the equivalent code on the identi cation plate. The e ective erythema and NMSC ratio must also match the speci ed range.
You may only use a lamp other than the recommended type if all of these criteria are met. You must also be aware that: a. The tanning unit is likely to be less e ective in terms of tanning performance. b. The circuit protection for your tanning unit must be adapted because the electrical current consumption will have changed. c. The UV classi cation no longer matches the original classi cation shown on the identi cation plate. d. We will not necessarily honour warranty claims arising from the use of lamps other than those we recommend, because the technical operation of your tanning unit might be a ected.
LAMPS ART NR EQUIVALENT CODES UV TYPE (EU) UV TYPE (NON EU)
Maxlight XL 180W-R CE III 12818 180-R-(21-28)/(2-2,6) 3 2
Maxlight XL 180W-R High Intensive 12821 180-R-(86-114)/(6,7-9,1) 5 5
Maxlight XL 200W-R High Intensive S 18525 200-R-(83-111)/(6,8-9,2) 5 5
Maxlight XL 180W-R CE III S 18067 180-R-(21-28)/(1,7-2,3) 3 2
Maxlight XL 180W-R CE III E 27353 180-R-(26-34)/(2-2,8) 3 2
Maxlight XL 180W-R High Intensive E 27354 180-R-(106-141)/(6,9-9,3) 5 5
Maxlight XL 200W-R Ultra Intensive E 27355 180-R-(138-184)/(8,8-12) 5 5
2
3
4
5
6
7
8
9
10
1
1
2
3
4
5
6
7
8
9
10
Operation
5
Display
Start/ Stop
Plus
Min
Bodycooling
Volume
Chanal
Switch song
Xsens
Qsens
Control functions
+
6
STARTING THE APPLIANCE IN STANDALONE MODE
Press start/stop The display shows the maximum tanning time.
The LEDs above plus/minus ash red. Set the desired time.
Press start/stop to conrm the set time. The tanning lamps now switch on. The timer counts down.
STARTING THE APPLIANCE WITH AN EXTERNAL TIMER OR COINBOX
The appliance will be started automatically if there is no ‘remote start’ present on the external timer or coinbox. If this is present, the LED above the start/stop button will ash green. The tanning session begins as soon as the start/stop button is pressed. The timer counts up.
PAUSE MODE
Press start/stop. The lamps are switched o. NOTE! The session time continues counting. Press start/stop again to restart the tanning session.
In stand-alone mode the session can be ended at any time by holding the start/stop button for three seconds.
The appliance is set up for standard use with an external timer or a coinbox. If the appliance must function without the external timer or coinbox, i.e. with an internal timer, the required tanning time will have to be adjusted according to the following procedure.
Note: If an external timer or coinbox does not have a ‘remote start’ function and instead the appliance must be started with
the start/stop button, this can be congured by your dealer.