Hanyoung RT9 Instruction Manual

RT9
INSTRUCTION MANUAL
Thank you for the purchase of HANYOUNG product. Please read this manual carefully.
Recorder & Temperature Controller
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
Contents
1. SAFETY INFORMATION
2. INSTRUCTION
3. ORDERING INFORMATION
4. SPECIFICATION
5. DIMENSIONS & PANEL CUTOUT
6. TERMINAL ARRANGEMENT
7 NAME & FUNCTION
8. TABLE OF SETTING ITEMS
10. SETTING METHOD
20. GROUP SETTING
21. FUNCTION
4
6
6
7
11
11
12
13
15
16
23
2
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
RT9
Zoom function
Various Alarms
Universal Input Output
Interface (RS485)
Free scale
PID Auto tuning
Record and Temperature
control
Universal Input
Output / Small-sized Recorder &
Temperature controller (
0.3 class high accuracy)
3
Features
Model : RT9
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
SAFETY INFORMATION
4
1
Before using, please read this (SAFETY INFORMATION) It is most important that the instructions in this manual are followed when using this instrument. Please keep this manual for future reference. Precautions are classified as WARNING and CAUTION.
WARNING
1. Caution on wiring
Use an external protection circuit if a fault in the control loop could possibly lead to a serious problem. This instrument does not have a switch for power and a fuse, so please install them if reguired. (Fuse rating 250V, 0.5A)
2. Power supply
Use a rated voltage to prevent damage or trouble. To avoid electrical shock or damage, do not turn ON the power until the wiring is completed.
3. Prohibit use in gas atmosphere
Do not use it at a place exposed to combustible or explosive gas.
4. Handling of unit
To avoid malfunction, electrical shock or fire, this unit must not be disassembled or repaired. Do not touch the terminals to avoid electrical shock or malfunction.
5. Caution on maintenance
Turn OFF the power before mounting or removing the instrument. To ensure continuous and safe operation of the instrument, periodical maintenance is recommended. Some parts are limited in life. The warranty period is 1 year only if using in the correct way.
CAUTION
1. Caution on handling
Do not install the instrument under any of the following condltions.
The ambient temperature exceeds 0 ~ 50 The ambient humidity exceeds 20 ~ 90%RH. A place where temperature changes suddenly or icing occurs. A place exposed to corrosive gas or combustible gas. Vibration or shock is likely to be transmitted to the instrument. A place exposed to water, oil, chemicals, steam, sunlight. A place exposed to much dust, salt or iron. A place with much inductive disturbance, static electricity, magnetism noise. A place where heat such as radiant heat stays.
WARNING
CAUTION
There is a possibility of death or heavy injury when handling in wrong way.
There is a possibility of injury or physical damage when handling in wrong way.
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
2. Installation
Attach the brackets (2 units) on the fixed halls and tighten with a screwdriver. Fixing torque is about 14.7N. cm (1.5kg.cm). (Care should be taken not to tighten forcedly.)
Indoor use.
Altitude up to 2000m use.
Mains supply voltage fluctuations not to exceed 10 of the normal voltage.
Installation Categories
Pollution degree 2
3. Caution on terminal connections
Use a compensating cable with thermocouple.
For R.T.D input use a cable which is a small lead wire resistance and without resistance
difference to 3wires.
To avoid inductive noise to input wires separate from the power and output wires.
Keep input wires away from output wires and use shielded wires to earth.
If the wiring has noise, use the following step: connect a surge absorber to the conductor coil
side if the conductors are connected to the load output, such as the relay contact output.
Use an insulating transformer with a noise filter when the power suppy has much noise.
Noise filter should be mounted on a panel which has been earthed and the wiring between the
noise filter output and the instrument power terminals should be shorten.
It is effective to use a twisted cable for power supply against noise.
The heater power supply and the instrument power supply should be connected using the
same power suppy when a heater break alarm.
Time for preparation of contact output is required at power ON. When the output signal is used
for an extenal interlock circuit, connect a delay relay.
4. For load circuit connection
Use an extra relay when the frequency of operation is rather high. In this case, SSR output type
is Recommended.
Electromagnetic switch : Proportional cycle time is Min. 30 sec
SSR : Proportional cycle time is Min. 2 sec
Contact output life : Mechanical : Min. 10 million times (no load)
Electrical : Min. 100 thousand times (rated load)
SSR drive pulse voltage, DC 4~20mA are not insulated with internal circuit. Use non-grounded sensor to R.T.D and thermocouple.
5. Caution on key operation / trouble
If alarm function is not set correctly, alarm output can not operate correctly a trouble. Be sure to check the alarm operation.
If the input cable is disconnected, the display shows “ ”. When replacing the sensor, please turn OFF the power supply.
6. Other
Do not use organic solvents such as alcohol, benzine when cleaning. (Use neutral detergent)
5
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
ORDERING INFORMATION
6
INSTRUCTION
2
3
Control output
0 1 2 3
RT9 - 1
Relay (ON / OFF control)
SSR
SCR (4 ~ 20 mA DC)
Relay (P.I.D control)
This instrument has process-value (PV) and set-value (SV) each 4 digits with 7 segment FND. This instrument is divided either Recorder and Recorder with Controller.
Function and feature
: Group P.I.D, Universal-input (19 types), Universal-output (Relay, SSR, SCR), Auto-tuning 2
types (standard type, low PV type), Communication (RS485), 20 types of alarm, Sampling cycle 250ms,
0.3 of FS high accuracy. And there are Zoom function, Graphic or Text printing selectable function, List printing function, Feed function, Free scale function. RT9 is the smallest Recorder with controller.
Recorder &
Temperature Controller
Control Output
Output code
RT9 -
96
96 mm
Recorder
Recorder & Temperature Controller
Others
None
Alarm 1
Alarm 1, 2
RS485
RS485 / Alarm 1
RS485 / Alarm 1, Alarm 2
0 1
0 1
0 1 2 3 4 5
Description
Suffix code
Model
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
7
SPECIFICATION
4
INPUT
OUTPUT
Input
Sampling time
Input resolution
Input impedance
Lead wire tolerable
resistance
Input tolerable voltage
Noise removal rate
Standard
Standard junction temp.
compensation tolerance
Burn-out
Accuracy
Input range
Thermocouple : K, J, E, T, R, S, B, L, N, U, WRe 5-26, PL­R.T.D : Pt 100 , KPt 100 Direct voltage: 1 ~ 5 V, -10 ~ 20 mV, 0 ~ 100 mV (Free scale type) 250 mS Below decimal point of measurement range T/C and mV input : 1
min., V DC : 1
R.T.D : 10 max. / wire
10 V (T/C, R.T.D, Voltage : mV DC), 20 V (Voltage : V DC) NMRR(normal mode) : 40 dB min. CMRR(common mode) : 120 dB min. (50/60 Hz
1 %)
T/C, R.T.D: KS, IEC, DIN
1.5 (15 ~ 35 ), 2.0 (0 ~ 50 )
T/C : OFF, Up/Down selectable R.T.D : Up scale (Detection current : 50 mA)
0.3 % (Full scale) Refer to “Input signal and Measurement range” T/C and R.T.D are changeable within range of input signal and measurement range. Voltage: min. voltage and max. voltage are available within range of
measurement. Scaling available.
CONTROL OUTPUT
Relay
contact output
SSR drive
voltage output
Current output
(4 ~ 20 mA DC)
Contact capacity : 240 V AC 3 A, 30 V DC 3 A (resistive load), Contact : 1 C Output operation : P.I.D control, ON/OFF Proportional cycle : 1 ~ 1,000 sec. Output limit : 0.0 ~ 100.0 % range, higher limit(OH) or lower limit(OL)
selectable (valid when AT) ON/OFF hysteresis : 0 ~ 100 %(Full scale) Time resolution : 0.1 % or 10 mS ON voltage : 24 V DC min.(resistive load 600
min., 30 mA limit when short) OFF voltage : 0.1 V DC max. Proportional cycle : 1 ~ 1,000 sec. Output operation : P.I.D control Output limit : 0.0 ~ 100.0 % range, higher limit(OH) or lower limit(OL)
selectable (valid when AT) Time resolution : 0.1 % or 10 mS Current output range : 4 ~ 20 mA DC, Resistive load : 600
max.
Accuracy :
0.5 % of full scale (4 ~ 20 mA range), Resolution : Approx. 3,000 Output ripple : 0.3 %(P-P) of max. scale (150 Hz) Sampling time : 250 mS Output operation : P.I.D control Output limit : -5.0 ~ 105.0 % range, higher limit(OH) or lower limit(OL)
selectable (valid when AT)
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
8
FUNCTION
OPERATING ENVIRONMENT
Relay
contact output
Contact capacity : 240 V AC 1 A, 30 V DC 1 A(resistive load) Contact: 1 a Output points: 2 Points (AL1,AL2)
ALARM
Input correction (Bias): -100.0 ~ 100.0 % for instrument range Scaling : According to SH, SL of measurement range Filter : OFF, 1 ~ 120 sec. 3 settings (SV1, SV2 and SV3) and P.I.D setting each Auto tuning : According to set value (Standard type, Low PV type) Proportional Band : 0.1 ~ 999.9 % (Max. range) Integral Time : OFF, 1 ~ 6000 sec. Derivative Time : OFF, 1 ~ 6000 sec. ON/OFF control : By selecting output code (OT) “ 0 ” P.I.D selection : Zone PID/Auto 1,2,3, selectable Manual Reset : -5.0 ~ 105.0 % of output (valid when I=OFF) Direct / Reverse action : Changeable by parameter Preset output limit : -5.0 ~ 105.0 % of output value ON/OFF hysteresis (HYS) : 0.0 ~ 100.0% of instrument range (valid when ON/OFF control) A.R.W(Anti Reset Wind-up) : AUTO, 50.0 ~ 200.0 % Fuzzy : selection ON or OFF by parameter Ramp function Set point : 2 Points Multi-alarm : High/Low process alarm, High/Low deviation alarm, Hold function of alarm, Heater break alarm (H.B.A) Setting range : Process alarm
0 ~ 100 % of instrument range
Deviation alarm
-100 ~ 100 % of instrument range Measuring point : 1 Response time : According to chart speed Record type : Thermal line, 203 dpi(8.0 dots/mm) 384 dots / 1 line Record speed : 24 mm/h ~ 900 mm/h Paper : Width 57.5 mm, Length 16 m
Measurement input
Control
Alarm output
Record
Installation environment
Normal operation
condition
Influence of ambient
temperature
Continuous vibration (5~14Hz): Forward width 1.2 mm max.
(4~150Hz): 4.9
(0.5 G) max.
Vibration : 14.7
, 15 sec. max. (each 3 direction)
Shock : 147
(15 G), 11 msec max. (6 direction each 3 times) Panel cutout: Refer to page 11 Ambient temperature : 0 ~ 50 Ambient humidity : 35 ~ 85 % RH (no condensation) Influence of magnetic : 400 AT/m max. Warm-up time: 30 min. min. T/C, Voltage input :
1 V/ or 0.01 %/ of max. range
R.T.D input :
0.05 / max.
Analog output :
0.05 %/ max. (continuous output)
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
9
Under process Under process
Safety standard
EMC standard
100 ~ 240 V AC (90 ~ 264 V AC) 50/60 Hz
6.0 W max., 10 VA max. Between primary terminal and secondary terminal : 500 V DC, 20
min.
Between primary terminal and ground : 500 V DC, 20
min.
Between ground and secondary terminal : 500 V DC, 20
min. Between primary terminal and secondary terminal : 2,300V AC 50/60 Hz for 1 min. Between primary terminal and ground : 2,300 V AC 50/60 Hz for 1 min. Between F
G and secondary terminal : 1,500 V AC 50/60 Hz for 1 min.
Power supply
Frequency
Power consumption
Insulation resistance
Dielectric strength
Standard
Communication address
Communication method
Synchronization
Communication sequence
Communication distance
Communication speed
Start bit Data bit
Parity bit
Stop bit
Communication protocol
Response time
EIA RS485 Max. 31 (1 ~ 99 setting available) 2 wire half duplex or 4 wire half duplex Start-stop synchronous mode None
1.2 Km max. 600, 1200, 2400, 4800, 9600 BPS (Speed is changeable by parameter) 1 BIT 7 or 8 BIT None, even numbers, odd numbers 1 or 2 BIT PC LINK WITHOUT SUM(0), PC LINK WITH SUM(1) Reception treatment time + (Response time
10 mS)
POWER SUPPLY
INTERFACE
SAFETY AND EMC STANDARD
External Dimension
96(W)
96(H) 100(D) mm
MODEL
RT9
Weight
530 g
Material
Plastic case(ABS)
STRUCTURE
STORAGE CONDITION
Storage temperature
Storage humidity
Shock
-25 ~ 70 5 ~ 95 % RH (no condensation) 1 m max. in packing condition
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
10
Thermo
-couple (T.C)
R.T.D
Direct voltage (V DC /
mV DC)
Direct
Current
Remarks
Accuracy
Range(
)
Range (
)
Input code
Input type (Input signal)
K K
J E T R B S L N U
W
Platinel
KSPt 100 Pt 100 1 ~ 5 V DC 0 ~ 10 V DC
-10 ~ 20 mV DC 0 ~ 100 mV DC
4 ~ 20 mA DC
0.3 % of F.S 1 digit
0.3 % of F.S 1 digit
0.3 % of F.S 1 digit
1.0 % of F.S 1 digit
0.3 % of F.S 1 digit
0.3 % of F.S 1 digit
-300~2500 0~2300
-300~2300
-300~1800
-300~750 32~3100 32~3300 32~3100
-300~1300
-300~2400
-300~750 32~4200 32~2500
-199.9~999.9
-300~1180
1 2 3 4 5 6 7 8
9 10 11 12 13 20 21 30 31 32 33
30
2 2 2 2 2 2 1
2
2
3 3
-200~1370
-199.9~999.9
-199.9~999.9
-199.9~999.9
-199.9~400.0 0~1700 0~1800 0~1700
-199.9~900.0
-200~1300
-199.9~400.0 0~2300 0~1390
-199.9~500.0
-199.9~640.0
F.S is maxium value ~ minimum value of each RANGE. Digit is minimum value of display
1
0 ~ 400
: 10 %
of F.S
1 digit
2
0
and below :
1.0 % of F.S 1 digit
3
-150.0~150.0
range :
1.0 % of F.S 1
digit
20 KPt 100 21 DPt 100
1 ~ 5 V
0 ~ 10 V DC
-10 ~ 20 mV 0 ~ 100 mV
When using current input, use the resistor 250
0.1 % on input
terminal.
INPUT SIGNAL and MEASUREMENT RANGE
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
DIMENSIONS & PANEL CUTOUT
5
11
TERMINAL ARRANGEMENT
6
Relay(Terminal no. ) SSR / SCR (Termina no. ) 100 - 240 V AC 50/60 Hz. (Termina no. ) Termocouple:
+, R.T.D: A, B Direct Voltage :
+, Alarm1 (Terminal no. ) Alarm2 (Terminal no. ) Sending data ( ) Receiving data ( ) Earth for signal( )
Control Output
POWER
Input
AL1 / AL2
Communication
RS 485
(Unit : mm)
RT9 (96 96 mm)
Terminal structure
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
Functions
Functions No paper Recording in progress Alarm 1 ON Alarm 2 ON Displays set value and various parameters.(RT9-0 : Displays input type) Displays the process value. When setting, displays various modes. Flickers when the auto tuning operates. Lights when the control output is ON. Model name Manufacturer
Used to change mode.
Used to increase set-value.
Used to decrease set-value.
Used to select digit for changing.
Name P.END RUN AL1 AL2 Set-value(SV) Process-value(PV) AT OUT RT9 HANYOUNG
Key
NAME & FUNCTION
12
7
Front
Displays
Control keys
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
13
TABLE OF SETTING ITEMS
8
Power ON
Operation Menu screen
3 sec.
Operation display status.
Set value changeable
Set a number
Output volume display
Recorder only (RT9-0): Control group Alarm group (Optional) Communication group (Optional) Input group Time setting group will be displayed.
Parameter structure
Group
Control
Group
Autotuning
Group P.I.D
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
14
Group
Alarm
Group
Communication
Group
Output
Group
Input
Group
Time setting
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
After completion of wiring, apply power ON. Management version indicated as below and then present PV and SV will be indicated.
(Record exclusiue use : Input type and PV will be indicated)
For setting a level, press button for 3 sec. to enter setting mode.(Initial value : ) In the condition, press button to enter group control.
SETTING METHOD
15
9
For 3 sec
Group Control
Group Auto tuning
Group PID
Group Alarm
Group Communication
Group Output
Group Input
Group Time setting
Group Control
Group Alarm
Group Communication
Group Input
Group Time setting
Recorder
(Model:RT9-0)
Recorder& Controller
(Model:RT9-1)
Parameter shift
Power ON
How to operate RECORDER
RUN
Press buttons simultaneously (RUN lamp will be ON)
Stop
Press buttons simultaneously
(RUN lamp will be OFF) Graphic or Text printing selection
In condition of printing, press
button for 3 sec.(Graphic
Text Graphic ...)
List printing
In condition of printing, press
button for 3 sec.
Feed paper
While holding down the button,
press button to feed paper.
Recorder
: Displays input type and PV
Recorder & controller
: Displays SV and PV
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
This controller has 3 different levels of setting, thereby restricting operator access if so desired.
InitialConditionDescriptionNameSignal
Control group display
Zone selection 1
Fuzzy function
Initial increasing temperature
Initial decreasing temperature
Time unit
Set speed of transmission
Zoom
Set a control mode
OFF / ON
OFF / ON
OFF / EUS (0~100 %)
OFF / EUS (0~100 %)
HOUR / MIN
24 ~ 900 mm/hour
OFF / ON
Always
Except ON/OFF
Always
Always
Always
Always
Always
Always
OFF
OFF
OFF
OFF
HOUR
60
OFF
16
GROUP SETTING
10
InitialConditionDescriptionDisplay NameSignal
Display level setting
Divide display levels into 3 stages (1~3)
3
Always
Control group setting
Display level setting
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
Auto-tuning
The Auto tuning function automatically measures, computes and set the optimum P.I.D value.
Note After setting all group, select AUTO in Auto tuning group.
Auto-tuning type This controller has two types of auto tuning as STD (standard type) and Low. (Low PV type : SV-10%)
Auto-tuning start stop
Auto tuning start : 1~ 3 selection
(After auto tuning , P.I.D value will be stored at a selected number)
Selection
When setting a value on 1.RP and 2.RP, it is stored in group 1,2,3 automatically
Auto tuning stop : Select OFF
17
STD
OFF
InitialConditionDescriptionName
Signal
Auto tuning group
Auto tuning type
Auto tuning start
Indicates Auto-turing
/
OFF / 1~3 /
RT9-1
ABS
ABS
P.I.D group
Anti Reset Wind-up
P.I.D group selection
n.Proportional band (P)
n.Integral time (I)
n.Derivative time (D)
n.Manual reset
n.Zone position
RT9-1
Except
ON/OFF
Always
P.I.D group
P.I.D group
P.I.D group
Integral time
: OFF
ZONE : ON
Auto
0
5.0 %
240 sec
60 sec
50.0 %
EU
(100.0 %)
Auto tuning group setting (Model: RT9-1)
P.I.D Group setting (Model: RT9-1)
Set P.I.D mode
Auto / 50.0 ~ 200.0 %
0 / 1 ~ 3
0.1 ~ 999.9 %
OFF / 1 ~ 6000 sec
OFF / 1 ~ 6000 sec
-5.0 ~ 105.0 %
EU(0) < 1.RP < 2.RP < EU(100.0 %)
InitialConditionDescriptionNameSignal
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
When checking P.I.D. values or setting SV in manual mode, this can be done in P.I.D. Group. Press key to get Anti Reset Wind value by auto or manual and then press once more to be indicated P.I.D mode which is selectable 3 types of P.I.D group (0~3). Example, “0” is no P.I.D mode and after seleting “1” using or and pressing , it is available to change P.I.D value in zone “1”. (“2” and “3” are same as “1”) When integral time is OFF, manual reset mode is indicated and then you could set reset value to remove off set. (range: -5 % ~ 105.0 % of proportional band). You could set 3 zones by selecting zone mode ON.
18
Alarm group setting (Optional)
Time
Zone 3
Set point of Zone 2 (2,RP)
Set point of Zone 1 (1,RP)
Maximum Range (Eu:100%)
Minimum (Eu: 0%)
Zone 2
Zone 1
There are 2 alarm outputs available per controller. In Alarm Group, setting are made for mode, dead band and value of each alarm. Refer to the next page for the 20 different types of alarm functions.
Initial valueConditionDescriptionNameSignal
1
2
EUS(0.5%)
EU(100.0%)
EU(0.0%)
Optional
Always
Always
Always
Set alarm mode
OFF / 1 ~ 22
Refer to
Alarm type and code
EUS ( 0.0 ~ 100.0 % )
PV alarm, Deviation alarm:
EU ( -100.0 ~ 100.0 % )
Alarm group
Type of Alarm 1
Type of Alarm 2
Dead band of Alarm 1
Dead band of Alarm 2
Set value of Alarm 1
Set value of Alarm 2
Reference : Display lamp will be OFF when output ON in inverted type.
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
19
( : Set point , : Minus Alarm set point , : Alarm set point )
Code
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
High absolute value
Low absolute value
High deviation value
Low deviation value
High deviation value (inverted)
Low deviation value (inverted)
High
Low deviation value
High
Low band
High absolute (inverted)
Low absolute (inverted)
High absolute with hold function
Low absolute with hold function
High deviation with hold function
Low deviation with hold function
High deviation with hold function (inverted) Low deviation with hold function (inverted) High
Low deviation with hold
function
High
Low band with hold function
High absolute value with hold function (inverted) Low absolute value with hold function (inverted)
Function
ALARM TYPE AND CODE
Alarm type
Hysteresis
(Notice) : Display lamp will be ON when output OFF in inverted type.
Marked alarms are not available in RT9-0
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
Initial valueConditionDescriptionNameSignal Communication group RS485/RS422 Protocol Communication rate (B.P.S)
Parity check
Stop bit
Data length
Address
Response time
Set communication mode
PC.LINK(Set value:0) / PC.LINK SUM (Set value:1) 600(SV:0) / 1200(SV:1) / 2400(SV:2) 4800(SV:3) / 9600(SV:4)
NONE(SV:0) / EVEN(SV:1) / ODD(SV:2)
1bit (SV:1) / 2bit (SV:2)
7bit (SV:7) / 8bit (SV:8) (Except PC LINK :8)
1 ~ 99, maximum 31 devices
0 ~ 10. response time = (handling time + response time) X 10 ms
Optional
0
4
1
1
8
1
0
20
Communication group setting (Optional)
Output group setting (Model : RT9-1)
RT9 series is equipped with 4 wire /2 wire half-duplex the RS485 / RS422 communication interfaces. Using the interfaces, communications are available with maximum 31 devices.
Output group
Output signal
Output operation
Cycle time
Hysteresis
Output volume when input disconnection Output (Out)
Maximum value of output
Minimum value of output
Model:RT9-1
Always
Always
Relay / SSR
ON/OFF
Control
Always
Except
ON/OFF
Except
ON/OFF
3
REV
30 sec
0
0.0 %
100.0 %
0.0 %
Initial value
ConditionDescriptionNameSignal
Output type and mode selection
Refor to type of control output
REV: Reverse DIR: Direct action
1 ~ 1000 sec
EUS(0.0 ~ 100.0 %)
-5.0 ~ 105.0 %
OL-L + 1 Digit ~ 105.0 %
-0.5 % ~ OL-H-1 Digit
When setting, Input type selection number must be selected in the input type selection mode and also
Output type selection number must be selected in the output type selection
mode before moving to other mode. If not, data of other group will be changed to prior value.
CAUTION
Output is selectable among Relay, SSR and Current(4 ~ 20 mA DC). For Recorder & Controller, output code 0 ~ 3 are available for your use.
Optional
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
Input type selection After power ON and when PV is indicating, press key for 3 sec to be displayed at PV and 3 at SV. (If it is not indicated 3, set again in the level setting mode) Control group is indicated when press key once more. At the time, input group is indicated when press key and then
Input type and range selection is shown at SV when press .
At this time the input and range is selected by or key. Press key to confirm
Maximum and Minimum range Press key to set Maximum and Minimum range using ,
or key. Press key once more to finish.
Decimal point Parameter is not indicated in T.C and R.T.D input, but when selecting voltage input
Decimal
point
mode is indicated. (set 1 : 0.0, set 2 : 0.00, set 3 : 0.000)
Maximum and Minimum on scale It is the same function as Maximum and Minimum Range setting when R.T.D or thermocouple input. This mode is indicated when voltage input ( 30, 31, 32, 33 )
Selection
NO.1
1370
-200
1
100.0
0.0
OFF
EUS(0.0 %)
UP
Initial valueConditionDescriptionNameSignal
Input group
Input signal selection
High limit
Low limit
Decimal point (on voltage input) Maximum on scale (on voltage input) Minimum on scale (on voltage input)
PV filter
PV bias
Burn-out
Input type and mode selection
Refer to input signal and range
Refer to input signal and range ( Notice : FR-H > FR-L )
Thermocouple or R.T.D : Not available DC Voltage : 0~3
-1999~9999 Notice : SL-H
SL-L
Deimal point : according to DP-P
OFF/1~120sec
EUS (-100.0~100.0%)
OFF / UP / DOWN
Always
Always
Always
Always
On voltage
input (mV,V)
On voltage
input (mV,V)
Always
Always
Always
21
Input group setting
When setting, Input type selection number must be selected in the input type selection mode and also
Output type selection number must be selected in the output type selection
mode before moving to other mode. If not, data of other group will be changed to prior value.
CAUTION
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
22
Time group
Set Year
Set Month
Set Day
Set Hour
Set Minute
Set Second
Set Y, M, D, T.
2000 ~ 2099
1 ~ 12
1 ~ 31
0 ~ 23
0 ~ 59
0 ~ 59
Always
Always
Always
Always
Always
Always
Always
Present value
Present value
Present value
Present value
Present value
Present value
Time group setting
PV filter When PV value becomes unstable due to effects of noise, the filter helps suppress the unstable status. (Range: OFF or 1 ~ 120 sec. initial value: OFF)
PV bias Use this function to adjust PV value in cases where it is necessary for PV value to agree with another recorder or indicator, or when the sensor cannot be mounted in correct location. (Range : -100.0 ~ 100.0 % of SPAN, lnitial value : 0.0 %) Setting a value using , or key and press key to finish.
Initial valueConditionDescriptionNameSignal
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
RAMP FUNCTION
It is a rate of set value to arrive to set value according to setting temperature and time. ex)Present temp. 20
, set value 100 , 20
per min. Initial uprising set value(up,rt) : 100 Unit time : Minute (min)
100
Time/Min
1234
80
60
40
Present
temp 20
23
FUNCTION
11
ZOOM FUNCTION
When you choose Zoom function ON in Group control, you can see a temperature with zooming as soon as you select ON. The temperature will be in the center of paper. ex) Scale : 0.0 ~ 100.0
Zoom ON : ZOOM IN PV : 25.5 at the
center
AUTO TUNING
STANDARD TYPE AUTO-TUNING
Temperature
Set point
value (SV)
Process
value (PV)
Control
output
ON ON ON
Time (t)
Time (t)
PID control
ON/OFF operation
AT started
AT finished
AT finished
Under AT
OFF OFF
LOW PV TYPE AUTO-TUNING
The Auto tuning function automatically measures, computes and sets the optimum Proportional band(P), Integral time(I), and Derivative time(D). When Auto-tuning, the controller performs ON/OFF control and determine proper P.I and D. (Limit cycle type) RT9-1 series have two types of Auto-tuning as below.
Standard type auto-tuning :
This type is based on set point value (SV)
Low PV type auto-tuning :
This type is based on the value 10 % lower than the set point value (SV)
Auto-tuning in Zone PID
Zone PID automatically sets PID group in accordance with a measured value. In Zone PID, auto-tuning sets the proper PID value by recognizing a mid-value of reference point as set point value.
Temperature
Set point
value (SV)
Process
value (PV)
Control
output
ON ON ON
Time (t)
SV-10%
Time (t)
PID control
ON/OFF operation
AT started
Under AT
OFF OFF
max. value of measuriag range (SV)
Reference
point 2
Reference
point 1
min. value of measuring range
PID 1
PID 2
PID 3
Time (t)
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
Graphic Text
List printing : You can check and keep an
important data which is set in each parameter.
24
FUZZY CONTROL
Fuzzy control eliminates overshoot using Fuzzy Logic. Employing Fuzzy control and Auto­tuning, the controller effectively control as below.
When the controller starts control at the position which has a big gap between SV and PV. When reducing warming up time When the load is fluctuating extreamly When changing a set point value frequently
Target set value
Set point value
Subsidary target value
measured value
Fuzzy Logic start
Time (t)
Control output is set in high and low limit as operating range. Output limit is -5 ~ 105 % of output.
OUTPUT LIMIT
20 mA
Output signal
12 mA
4 mA
OL-H
Output limit (%)
OL-L setting range
105 %50 %-5 %
When A/D error or input disconnection occur in auto mode, PID output is cut and than Pre-set output is operated. (PO Output)
Emergency output
Hold function
Hold function : None
(Picture 1)
HOLD FUNCTION
Without hold function, Low limit alarm will be ON when increasing temperature. (Picture 1)
SV
(low limit alarm)
Power ON
Alarm output
ON OFF ON OFF
PV
(Picture 2)
SV
(low limit alarm)
Power ON
Alarm output OFF OFF ON OFF
PV
RECORDER
Run/Stop : You can record or stop when you
need. Feed : Paper can be transmitted forcedly. Graphic or Text selectable
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
MEMO
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
MA01E50110
#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) 876-4697 FAX:(82-32) 876-4696 http://www.hynux.com E-mail: sdt@hyelec.co.kr
هرﮐ ﮓﻧﺎﯾﻧﺎھ تﻻوﺻﺣﻣ یرﺎﺻﺣﻧا هدﻧﯾﺎﻣﻧ ناوﯾﺳ تﮐرﺷ
www.sivancarno.com
Loading...