GE Series Gas Detector with Battery Backup Design
Introduction
GE series Gas leak alarm is a kind of wall-hung household gas alarm designed to detect the concentration of combustible and toxic gases or vapors. It provide a visual and audible signals when the gas concentration reaches presetting level, remind you take prompt favorable action, you may start up other link equipment, ventilate gas or shut off gas supply to avoid Fire, explosion, suffocation, and other evil accident. The alarms are available for liquefied petroleum gas (LPG), natural gas (Methane), propane, Hydrogen, town gas, smoke, etc. They are not only installed at home, but also used at any other potentially hazardous areas.
MCU control, Reliable without false alarming Locale sound and light alarming,Drive Long-distance Alarming System Ventilate good air circulation or shut off gas supply link equipment
Technical Conditions
Operating Voltage AC220±10% / AC110v ±10% or DC12V Power Consumption:≤3W Size Operating Time : -10℃~50℃ Hum:<95RH
Model Detecting Gas Response time Alarming Preset Level (Optional) GE - 201 LPG
20S 10%LEL ±30%
GE - 221 Combustible gas
20S 10%LEL ±10%
GE - 401 Natural Gas
20S 5000ppmCH
4
±30%
GE - 601 Combustible gas
20S 2000ppm LPG ±30%
GE - 501 Coal Gas
20S 1000ppm Coal Gas ±30%
GE - 701 CO
2.5min 150ppm CO ±30%
GE- 801 Hydrogen ≤20S 1000ppm H2 ±30% GE - 901 CO+Combustible gas
2.5min 150ppm CO/1000ppmLPG ±30%
Automatic Resume Can be specified
Optional Function: Gas Shut Off VALVE Output pulse 10Hz DC8V/Max200mA, When alarming appears; Relay Output N.O Max AC220V 3A Battery Backup4 hours lasting without other power supply
Operating Manual
1
Fix gas alarm on the wall or Roof near the gas cooker or other sources within 2-4m interval. according to gas sources
Character, Choose alarm location as follows:
·LPGFix it within 0.3 meters above the ground (LPG is heavier than Air)
·Coal Gas, Natural Gas Fix it within 0.3 meters below the Roof ( Combustible gas is lighter than Air)
·Avoid such installation Windows with strong wind, Exit、water fog and drop placeeasy polluted or high tem
environment near Oven, covering around
2Connect the Power supply, (If need ventilate fan, electrovalve other link equipment, please connect corresponding
circuit firstly.) Preheat the alarm 1 min, the alarm without detecting function.1 MIN later, the alarm enter into detecting status.
3If the flammable gas in the air reaches the preset alarming concentration, the alarm enter into alarming status, the
Alarm red LED light or flash, the buzzer give sound alarming, drive the relay or valve shut off gas supply, If the alarm connect the ventilation fan or other relative electronics, it also open automatically, ; At the same time, please cut off gas supp ly promptly, open the window, ask professional worker to remove the fault, The alarm with gas cut off valve type shall output one close pulse signal.