INSTALLATION INSTRUCTIONS
Quiet Ventilation Fan/
Light/Nightlight
Models QV50L/QV80L/QV110L/QV150L
READ AND SAVE THESE INSTRUCTIONS
Quiet Decorative Ventilation
Fan/Light/Nightlight
Models QDV70L/QDV80L/QDV90L/
QDV110L/QDV130L/QDV150L
TABLE OF CONTENTS
GENERAL SAFETY INFORMATION................................................ ................. ..........2......... ..................
DESCRIPTION...................................................................................................................................3
COMPONENT PARTS.........................................................................................................................3
DIMENSIONS....................................................................................................................................4
SPECIFICATIONS..............................................................................................................................4
INSTALLATION..................................................................................................................................5
CLEANING & MAINTENANCE..............................................................................................................7
TROUBLE SHOOTING GUIDE.............................................................................................................7
SERVICE PARTS................................................................................................................................8
WARRANTY......................................................................................................................................9
The Honeywell trademark is used under license from Honeywell Intellectual Properties Inc.
by Lonon Industry Company, Ltd.
Honeywell International Inc. makes no representations or warranties with respect to this product.
GENERAL SAFETY INFORMATION
1. Do not install this ventilating fan where air temperature may exceed 104 F (40 C).
2. Make sure that the electric service supply voltage is 120V, 60Hz.
3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation
Safety and Health Act (OSHA).
4. Always disconnect the power source before working on or near the fan, motor or junction box or light fixture.
5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
6. Do not kink the power cord.
7. This unit is approved for use over a bathtub or shower when installed in a GFCI protected branch circuit.
8. This unit must be grounded.
9. This unit is U.L. Listed. Type I.C. Inherently protected.
10. These models are UL listed for tub and shower enclosures.
11. Provide suction parts with proper ventilation.
12. Do not install the unit where ducts are configured as shown in Fig.A.
Fig.A
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
1. Use this unit only in the manner intended by . If you have questions, please contact
Lonon USA, LLC
2. Before servicing or cleaning unit, switch the power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and
safety standards, such as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, make sure not to damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the outdoors.
7. NEVER place a switch where it can be reached from a tub or shower.
8. Please note that solid state controls may cause harmonic distortion that can cause motor humming
noise.
9. To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
10. Not to be in a ceiling thermally insulated to a value greater than R40.
11. Fluorescent models only: Do not use a dimmer switch to control the light of this unit.
12. Motor and grille assembly must be installed with housing assembly that are marked (on their cartons) to
indicate the suitability with this model. Other housing assembly cannot be substituted.
13. To reduce the risk of fire use only these 18 watt fluorescent lamps and 4 watt maximum type C
incandescent lamp nightlight.
at the address or telephone number listed in the warranty.
Lonon USA, LLC
Page 2
GENERAL SAFETY INFORMATION ( Continued )
CAUTION:
1. For general ventilating use only.
hazardous or explosive materials and vapors.
2. This product is designed for ceiling installation only. This
product is designed for installation in ceilings up to a 12/12
pitch. Ductwork must point up. DO NOT MOUNT THIS
PRODUCT ON A WALL.
3. The light fixture assembly must be mounted to the fan
housing assembly included with this product. Do not mount
the fight fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and / or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
5. Please read specification label on product for further
information and requirements.
6. Not for use in cooking area (Fig. B).
Do not use to exhaust
(Cooking area)
Do not install above or
inside this area
45
Cooking
equipment
45
Fig.B
Floor
DESCRIPTION
Thank you for selecting this high quantity Honeywell ventilation fan. Honeywell ventilation fans were designed with
your comfort in mind. With many different features, Honeywell fans fit your needs whether your bathroom is big or
small, needs a light, no light or even a nightlight, Honeywell fans have the features you need.
Honeywell ceiling mounted ventilation fans use a high-capacity sirocco fan driven by a capacitor motor. The sirocco
fan reduces the noise level.
Honeywell ventilation fans incorporate a thermal cut off for safety.
The grille unit can be quickly detached from the main unit for cleaning.
A damper for preventing air backdraft is incorporated into every fan.
The motor is designed to have an extended service life with reduced energy consumption.
The light unit is an energy efficient lighting device which uses two 18W compact fluorescent lamps.
COMPONENT PARTS
Part name
Grille
Suspension
bracket A
(12.6inches/320mm)
Suspension
bracket B
(9.5inches/240mm)
Suspension
bracket C
(6.3inches/160mm)
QV110L/150L
not supplied
Suspension
bracket D
(2.95inches/75mm)
QV110L/150L
not supplied
Suspension
bracket E
(5.3inches/135mm)
QV50L/80L
not supplied
Picture
Quantity
1
1
1
1
1
1
Part name
Glass sub-1
( glass grille )
Grille sub-2
Screw A
ST4X30
Screw B
M4X10
18 W
fluorescent lamp
4 W
Night lamp
Screw E
M5X20
Picture
Quantity
1
1
8
2
2
1
4
Page 3
DIMENSIONS
A
B
C
D
Model No.
QV50L
QV80L
QV90L
QV110L
QV130L
QV150L
QDV70L
QDV80L
QDV90L
QDV110L
QDV130L
QDV150L
E
I
J
F
254-584mm
G
H
ABCDE
""" "
10 9/16
12 5/16
10 9/16
12 5/16
10 5 1/2 4 12 3/16
"
"
11 7/16 6 3/8
""" "
10 5 1/2 4 12 3/16
"
"
11 7/16 6 3/8
6
6
13 3/4¾
13 3/4¾
A
B
""""
""""
C
D
FG
"
13 3/4¾
"
13 3/4¾
"
"
12 3/16
12 3/16
F
3 1/2 ½
4 5/16
3 1/2 ½
4 5/16
E
HI
"
3 1/8
3 1/8
"
"
3 1/8
3 1/8
"
I
J
J
4 1/8
4 1/8
4 1/8
4 1/8
"
"
7 7/8
7 7/8 ½
7 7/8
7 7/8 ½
"
""
"
""
254-584mm
G
H
"
"
"
"
SPECIFICATIONS
Model
No.
QV50L
QV80L
QV90L
QV110L
QV130L
QV150L
QDV70L
QDV80L
QDV90L
QDV110L
QDV130L
QDV150L
Power
Supply
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
120V/60Hz
Power consumption*(W)
Fan
Unit
17.0
Light Unit
Light Night Light
36.0 4.0 50 <0.3
Air
Movement
0.1" WG
(CFM)
Noise
(sone)
21.0 36.0 4.0 80 0.3
24.0 36.0 4.0 90 0.5
33.0
36.0 4.0 110 0.9
36.0 36.0 4.0 130 0.8
39.0 36.0 4.0 150 0.9
21.0
36.0 4.0 70 <0.3
23.0 36.0 4.0 80 0.5
24.0 36.0 4.0 90 0.5
32.0
36.0 4.0 110 0.3
35.0 36.0 4.0 130 0.6
41.0 36.0 4.0 150 1.0
Duct
Diameter
(inch)
4
4
4
6
6
6
4
4
4
6
6
6
Weight
(lb.)
9.9
9.9
9.9
12.5
12.5
12.5
15.32
15.32
15.32
19.29
19.29
19.29
*At 0.0" Static pressure (Pa).
Specifications are based on HVI standard.
Page 4