Hantek LA5034 User Manual

User’s Guide
LA5034
Operation Manual
Content
General safety summary ................................................................................... I
Introduction ...................................................................................................... II
Chapter 1 Getting started ................................................................................. 1
System Requirements ....................................................................... 2
Installing Hardware ............................................................................ 3
Installing Software ............................................................................. 6
User Interface .................................................................................. 10
Chapter 2 Menu ............................................................................................. 1 1
File ................................................................................................... 12
View ................................................................................................. 13
Setup ............................................................................................... 14
Analyzer ........................................................................................... 15
Help ................................................................................................. 16
Chapter 3 Advanced ...................................................................................... 17
Clock Panel ..................................................................................... 18
Bus Panel ........................................................................................ 19
Waveform Panel .............................................................................. 22
Measurement Panel......................................................................... 24
Export Data ...................................................................................... 25
Chapter 4 Trigger ........................................................................................... 26
Base Trigger Setup .......................................................................... 27
Advance Trigger Setup .................................................................... 29
Chapter 5 Plug Manager ................................................................................ 30
Summary ......................................................................................... 31
Example ........................................................................................... 32
Appendix ........................................................................................................ 35
Hardware Specification .................................................................... 36
Channels ......................................................................................... 37
Block Diagram ................................................................................. 39
Cleaning and maintenance .............................................................. 40
LA5034
General safety summary
Understand the following safety precautions to avoid injuries and to prevent damage to the product or the product of any product link. To avoid possible dangers, be sure to use the product in accordance with the regulations.
Only qualified personnel to perform maintenance procedures.  Prevent fire and personal injury. Use the right power cord. Only the country in which the authorized use of
this product for the power line.
Correctly inserted. Probe or test voltage wire connected to the source,
please do not plug.
Products will be grounded. This product through the power of the
grounding wire grounding. To avoid electric shocks, grounding conductor must be connected to. In this connection the import or export of products before the end, be sure to correct grounding for this product.
Properly connected probe. Probe the ground with the same potential. Do
not connect high-voltage ground.
See all the terminals rating. To avoid excessive current fire and the
impact, see the product of all the ratings and tags; please connect products in the product manual inspection prior to understand the detailed ratings information.
Do not run the product if you open the cover or panel. Avoid the exposed circuit. Do not connect power after contact with the
exposed joints and components.
Suspected products to failure do not operate. If you suspect that this
product has been a failure, can be qualified maintenance personnel to be checked.
Maintain proper ventilation. Do not operate in the humid environment. Do not flammable and explosive environment operation. Please keep the product clean and dry surface.
LA5034 USB User’s Manual I
LA5034
LA5034 USB User’s Manual II
Introduction
The LA5034 is a sophisticated 500MHz, 34-channel logic analyzer used for testing, analysis, and troubleshooting of digital circuits. The LA5034 is equipped with features found only in more expensive bench type instruments The use of advanced large-scale integrated circuits, integrated USB 2.0, CPLD, FPGA, high-frequency digital circuitry, embedded systems, and other advanced technology, make the LA5034 to be portable, and easy-to-use, making the LA5034 your best choice in pc-based logic analyzers The LA5034 is very suitable for electronic measurement engineers, college students in scientific research and development and teaching assistants. The User’s Manual describes in detail the operation of the LA5034 as well as installation of the software. The LA5034 has a sufficient number of input channels and is capable of simultaneously observing a lot of information or data flow direction control information, and in some way of capturing narrow pulse interference. The LA5034 has the feature of delayed ability to capture the required observation points around the waveform, in a variety of digital information capture function. The LA5034 has adequate memory capacity to be both display error messages and to find faults in the source state. The LA5034 has intuitive and flexible displays to facilitate dynamic analysis, can transform the information, and the user can use the binary, decimal, hexadecimal or ASCII that information to facilitate the repair process and debug. The LA5034 can be triggered in a variety of ways, can display a very long data stream, on the basis of the analysis of that part of the information to make accurate positioning, and capture appropriate information for software analysis by using its tracking function trigger operation procedures. For hardware, trigger function can be detected in the system and that the interference and Burr. The LA5034 has reliable Burr detection ability. As competition in digital circuit, the signal crosstalk, interference and power coupling factors, often mixed with irregular signal in the burr, which will run from an incorrect circuit. The LA5034 can detect through special burr technology to capture and display.
LA5034
Chapter 1 Getting started
This chapter focuses on the following topics:
System Requirements Installing hardware Installing software Understanding of the user interface
LA5034 User’s Manual 1
LA5034
System Requirements
z Minimum System Requirements
Operating System
Windows NT/2000/XP/Vista
Memory
128MB
Graphic Card
Microsoft DirectX supported Screen resolution: 1024x768 Color depth: 16bit
z Recommended System Requirements
Operating System
Windows 2000/XP/Vista/Win 7
Memory
256MB
Graphic Card
Microsoft DirectX supported Screen resolution: 1024x768 Color depth: 16bit
LA5034 User’s Manual 2
LA5034
Installing Hardware
1. Connect the A-Type Plug of USB cable to your PC’s USB port.
2. Connect the B-Type Plug of USB cable to LA5034’s USB port.
3. New hardware is found.
4. New hardware search wizard starts.
LA5034 User’s Manual 3
LA5034
5. New hardware search wizard starts to search
6. New hardware wizard installs software
LA5034 User’s Manual 4
LA5034
7. Finish new hardware search wizard.
Caution:
Do not disconnect any device from the USB bus while the computer is communicating with the LA5034, or you may lose data and/or your ability to communicate with the LA5034. If the LED is illuminated but the turns off, the computer has lost communication with the LA5034.To restore communication, disconnect the USB cable from the computer, and then reconnect is. This should restore communication, and the LED should turn back on.
LA5034 User’s Manual 5
LA5034
Installing Software
1. While in Windows, insert the installation CD into the CD-ROM drive.
2. The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run "Setup.exe".
3. The LA5034 Installation is started. Click 'Next' to continue.
LA5034 User’s Manual 6
LA5034
4. Choose a destination directory. Click 'Next' to continue.
5. Check the setup information. Click Next to start copying of files.
LA5034 User’s Manual 7
LA5034
6. This Status dialog is displayed during copying of files.
7. Updating Your System Configuration.
LA5034 User’s Manual 8
LA5034
8. The installation is complete.
LA5034 User’s Manual 9
LA5034
User Interface
LA5034 provide users a simple and full-featured interface so that users do not have to spend a lot of time to learn. LA5034 provide clock panel, waveform panel, bus panel, measurement panel, trigger panel and plug manager.
LA5034 User’s Manual 10
Loading...