The copyright of this document belongs to Qingdao Hantek Electronics Co., Ltd.
Statement
Qingdao Hantek Electronics Co., Ltd. reserves the right to modify this document without notice.
Qingdao Hantek Electronics Co., Ltd. promises that the information provided is correct and reliable
but does not guarantee that this document is error-free. Before using this product, please make sure
that the relevant technical document is the latest and valid version. If your company uses the
documents or products of Qingdao Hantek Electronics Co., Ltd. and requires the cooperation of a
third party's products, patents or works, your company shall be responsible for obtaining the consent
and authorization of the third party. The above consent and authorization are not the responsibility of
the Hantek.
Product certification
Hantek certifies HT360 series leeb hardness tester to meet China national industry standards, has
passed the CE certification, and will further complete the certification of other national standards.
Contact us
If you have any questions when using the products of Qingdao Hantek Electronics Co., Ltd., you can
obtain services and support through the following ways:
Mail box: service@hantek.com , support@hantek.com
Website: http://www.hantek.com
Page 3
EN
Catalog
Catalog............................................................................................................................................. I
Illustrations List ............................................................................................................................ IV
List of Tables .................................................................................................................................. I
4.6.1 Front panel ........................................................................................................................................ 16
4.6.2 Side panel ......................................................................................................................................... 18
4.6.3 Top panel .......................................................................................................................................... 18
4.6.4 User interface ................................................................................................................................... 18
5.4 Save ............................................................................................................................................ 25
5.5 Information ................................................................................................................................. 26
Read the following safety precautions carefully to avoid injury and to prevent damage to
this product or any product connected to this product. To avoid possible hazards, be
sure to use this product as prescribed.
Only professionally authorized personnel should perform maintenance.
Check all terminal ratings.
To avoid fire or shock from excessive current, check all ratings and symbols on the
product. Consult the product manual for rating details before connecting the
product.
Do not operate with the cover open.
Do not run the product with the outer cover or panel open.
Do not operate the product when you suspect it is faulty.
If you suspect this product has been damaged, ask a qualified repairman to
inspect it.
Maintain proper ventilation.
Do not operate in a humid environment.
Do not operate in a flammable or explosive environment.
Please keep the product surface clean and dry.
Antistatic protection.
Static electricity may cause damage to the instrument. Test in an anti-static area
as far as possible. Before connecting the cable to the instrument, the inner and
outer conductors should be grounded briefly to release static electricity.
Use the batteries properly.
If batteries are provided, do not expose the batteries to high temperature or fire.
Keep batteries away from children. Replacing the battery incorrectly can cause an
explosion (warning: lithium-ion batteries). Only use batteries specified for this
product.
106 °F ~ 122 °F (+41 °C~45 °C): relative humidity ≤ 60%
The surrounding environment is free of vibration, strong magnetic field, corrosive
medium and serious dust.
Warning:
To avoid the risk of short circuit or electric shock in the internal circuit, do not
operate in a humid environment.
Altitude
When operating and not operating: 3000m (10000 feet).
Random vibration: 0.31 g RMS at 50Hz to 500Hz, 10 minutes per axial direction.
When not operating: 2.46g RMS from 5Hz to 500Hz, 10 minutes per axial direction.
Installation (overvoltage) category
This product is powered by a main power supply conforming to installation (overvoltage)
category II.
Warning:
Ensure that no over-voltage (such as lightning) reaches the product. Otherwise,
operators may be exposed to electric shock.
Definition of install (overvoltage) category
Installation (overvoltage) class I is the signal level that applies to the measuring
terminal of the device connected to the source circuit, where measures have been
taken to limit the instantaneous voltage to a correspondingly low level.
Installation (overvoltage) class II refers to the local distribution level, which is applicable
to devices connected to the mains (AC power supply).
Degree of pollution
2 class
Definition of pollution level
Pollution Level 1: No pollution, or only dry non-conductive pollution. This level of
contamination has no effect. Examples: clean rooms or office with air conditioning.
Pollution level 2: Generally only dry non-conductive pollution occurs. Temporary
conduction due to condensation may sometimes occur. Examples: general indoor
Pollution level 3: Conductive pollution occurs, or dry non-conductive pollution
becomes conductive due to condensation. Examples: sheltered outdoor
environment.
Pollution Level 4: Permanent conductive contamination through conductive dust,
rain or snow. Examples: outdoor sites.
Security level
Level 1 - Grounded product
1.4 Maintenance and cleaning
Maintenance:
Do not expose the LCD to direct sunlight for a long time when storing or placing the
hardness tester.
Cleaning:
Check the instrument frequently according to the requirements of operating conditions,
and clean the external surface according to the following steps:
1) Use a lint free rag to remove the floating dust on the outside of the hardness tester.
Be careful to avoid scratching the bright filter material of the display.
2) Clean the hardness tester with a soft cloth soaked in water. For more thorough
cleaning, use a 75% isopropyl alcohol water solvent.
Note:
To avoid damaging the surface of the instrument, do not use any corrosive reagents or
chemical cleaning reagents.
Warning:
Before reenergizing, please make sure that the instrument is dry to avoid electrical
short circuit or personal injury caused by moisture.
The following symbols indicate that this product complies with the requirements of
WEEE Directive 2002/96/EC.
Equipment recycling:
The production of this equipment requires the extraction and use of natural resources. If
the product is discarded improperly, some substances contained in the equipment may
be harmful to the environment or human health. In order to avoid releasing harmful
substances into the environment and reduce the use of natural resources, it is
recommended to adopt appropriate methods to recycle this product to ensure that most
materials can be reused correctly.
Apply Leeb hardness measurement principle to measure various metal materials,
including steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile
iron, cast aluminum alloy, copper zinc alloy, copper tin alloy, pure copper, forged
steel, etc;
Realize the mutual conversion between seven kinds of hardness scales: Leeb
(HL), Brinell (HB), Rockwell B (HRB), Rockwell C (HRC), Rockwell A (HRA),
Vickers (HV) and Shore (HS);
Support tests in 5 different directions, including vertical downward, oblique
downward, horizontal, oblique upward and vertical upward;
Equipped with D-type impact device, which supports DC, DL, D+15, G and other
types of impact devices;
Support Windows connection, equipped with USB Type-C interface, which can
easily and quickly exchange data with PC;
Adopt 2.8-inch color display which can provide informative and intuitive content;
The instrument is powered by rechargeable lithium battery, which can work
continuously for no less than 80 hours. The long-life and environmentally-friendly
battery has power saving functions such as backlight time adjustment and
automatic shutdown;
Chinese and English display, which is simple and convenient;
Large capacity memory, which can store 500 data of single measurement value of
the host, including measurement value, average value, measurement date, impact
direction, times, materials, hardness system and other information;
Applicable to quality control of heat treated workpieces, rapid inspection of
workpieces with small test space such as installed mechanical or permanent
assembly parts and mold cavities, rapid inspection of multiple parts of large
workpieces, failure analysis of pressure vessels, steam turbine generators and
other equipment, the material differentiation of bearing and other parts production
lines, metal material warehouses, production line of bearing and other
components, material differentiation of metal material warehouse, and hardness
testing of machine tool guides and automobile chassis.
HT360 series portable hardness tester adopts Leeb hardness measurement principle to
detect metal hardness, which can measure various metal materials including steel and
cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum
alloy, copper zinc alloy, copper tin alloy, pure copper, forged steel, etc; Realize the
mutual conversion between seven hardness scale, including Leeb (HL), Brinell (HB),
Rockwell B (HRB), Rockwell C (HRC), Rockwell A (HRA), Vickers (HV) and Shore (HS).
Adopt streamlined ergonomic structure design, equip with a support, and adopt 2.8 inch
high-definition display screen, which can display rich and intuitive information; Equip
with a large capacity memory, which can store up to 500 data. Support the optional
Bluetooth printer, which is convenient for users to output test results; Support Windows
program control connection to facilitate the storage, export and printing of computer
data.
This document is used to guide users to quickly understand the front panel, side panel,
user interface and basic operation methods of HT360 series Leeb hardness tester.
Tips:
The latest version of this manual can be accessed at (http://www.hantek.com).
Software version:
Software upgrade may change or add product features. Please follow the Hantek
website for the latest version.
Document format convention:
Key
Use icons to represent the front panel buttons. For example, represents the
"Scale" button.
1 Menu
Use "menu text (bold)+color (blue)" to indicate a menu option. For example, Measure
means clicking the "Measure" option on the current operation interface to enter function
configuration menu of “Measure”.
2 Operating Steps
Use the arrow ">" to indicate the next operation. For example, Print>Connect means
click Print and then click Connect.
Document content convention:
HT360 series Leeb hardness tester includes the following models. Unless otherwise
specified, this manual takes HT360C as an example to explain HT360 series and its
basic operation.
After receiving the hardness tester, users should check the equipment according to the
following steps: check whether there is any damage caused by transportation: if the
packaging carton or foam plastic protective pad is seriously damaged, please keep it
until the whole machine and accessories pass the electrical and mechanical tests.
Check the accessories
The details of the accessories provided are described in "Appendix A: Accessories and
Options" at the end of this manual. If the accessories are found missing or damaged,
please contact the dealer responsible for this business.
Check the whole machine
If the appearance of the instrument is damaged, the instrument does not work properly,
or fails to pass the performance test, please contact the dealer in charge of this
business.
under the effect of elastic force, and calculate the hardness value with the ratio of the
rebound speed and impact speed of the punch at a distance of 1mm from the sample
surface. The calculation formula is as follows:
HL=1000 * VB/VA
Where: HL - Leeb hardness value
VB -- Rebound speed of impact body
VA - Impact velocity of impact body
The output signal of the impact device is shown in the following diagram:
This series of hardness tester meets the following standards
1. GB/T 17394. 1-2014 Leeb Hardness Test for Metallic Materials Part 1: Test Method
2. GB/T 17394. 2-2012 Leeb Hardness Test for Metallic Materials Part 2: Verification and Calibration of Hardness Tester
11
Page 20
Quick Start
EN
3. GB/T 17394.3-2012 Leeb Hardness Test for Metallic Materials Part 4: Calibration of
Standard Hardness Blocks
4. GB/T 17394. 4-2014 Leeb Hardness Test for Metallic Materials Part 4: Standard
Value Conversion Table
5. Design basis and standard: Technical Conditions for Leeb Hardness Tester JB/T
9378-2001
4.5 Preparation before use
Preparation of sample surface
When preparing the sample surface, the influence of heating and cold working on the
sample surface hardness shall be avoided as far as possible.
If the measured surface is too rough, measurement error will be caused. Therefore, the
tested surface must show metallic luster and be flat, smooth and free of oil stain.
Curved surface: The test surface is better to be flat. When the curvature radius R of the
tested surface is less than 30mm (type D, DC, D+15, C, E, DL impact devices) and less
than 50mm (type G impact devices), small support rings or profiled support rings should
be used for testing.
Figure 4 Curved sample face
Support of sample
1. No support is required for heavy samples;
2. For medium-sized samples, they must be placed on a flat and firm plane. The
samples should be placed stably without any shaking;
3. The sample shall have sufficient thickness, and the minimum thickness of the sample
shall comply with Table 3;
4. For the samples with surface hardening layer, the depth of hardening layer shall
comply with Table 3.
Coupling
1. For the light sample, it must be tightly coupled with the solid support, the two
coupling surfaces must be flat and smooth, the amount of coupling agent must not be
too much, and the test direction must be perpendicular to the coupling plane;
2. When the sample is a large area plate, long rod or bending piece, if the weight and
thickness are too large, it may cause distortion and instability of the sample, leading to
inaccurate test values, so it should be reinforced or supported at the back of the test
point;
3. The magnetism of the sample should be less than 30 Gauss.
4.5.1 Measurement
Before measurement, random hardness block can be used to inspect the
instrument, and its display error and repeatability shall not be greater than those
specified in Table 4.1.
1. Booting
a. Insert the impact device plug into the impact device socket on the upper side of the
instrument;
b. Press the key. When the power is on, the instrument enters the measurement
state.
2. Loading
Figure 4 Loading
Push the loading sleeve downward to lock the impact body; For DC-type impact
device, place the loading bar on the test surface, insert the DC-type impact device
into the loading bar until its stop position, and then the loading is completed.
Press the support ring of the impact device tightly on the surface of the sample, and the
impact direction should be perpendicular to the test surface.
3. Measuring
Press the release button on the upper part of the impact device to measure. At this
time, the sample, impact device and operator shall be stable, and the force
direction shall pass through the axis of the impact device;
The distance between
two indentation centers
is not less than (mm)
The distance between the
indentation center and the sample
edge is not less than (mm)
D、DC
3 5 DL 3 5
D+15
3
5
G 4 8
E 3 5
C 2 4
EN
Each measuring part of the sample is generally tested for five times. The data
dispersion shall not exceed ± 15HL of the average value;
The distance between any two indentations or the distance from the center of any
indentation to the edge of the sample shall comply with Table 4.2
For a specific material, in order to convert the Leeb hardness value to other
hardness values more accurately, a comparison test must be conducted to obtain
the corresponding conversion relationship. The method is: use qualified Leeb
hardness tester and corresponding hardness tester to test on the same sample
respectively. For each hardness value, measure five Leeb hardness values evenly
around more than three hardness indentations that need to be converted. Use the
average Leeb hardness value and the average corresponding hardness value as
the corresponding values, and make a hardness comparison curve. The
comparison curve shall include at least three groups of corresponding data.
Table 4 Measurement
4. Read the measured value
Take average value of several valid test points as one Leeb hardness test data.
Display the hardness value in front of the Leeb hardness symbol HL. The HL
values measured by different types of impact devices are different.
4.5.2 Adjusting the support
When using the instrument, the user can open the standing foot as a support to tilt the
instrument upward for easy operation and observation. When the instrument is not in
use, the user can close the support to facilitate placing or moving.
If the power key is pressed but the instrument does not respond, the battery may
be depleted.
You can charge the instrument as follows:
Method 1: Charge the instrument through the power adapter
Connect the instrument to the power socket through the standard power adapter (5V/2A)
and Type-C data cable for charging.
Method 2: Charge the instrument through Type-C interface
Connect the instrument to the computer or other equipment (5V/500mA) through Type-C
data cable for charging.
Charging state description:
When the battery is installed during charging, the indicator light of the power key is red,
and the battery box at the upper right corner of the instrument screen displays the
change of power. If the battery is not installed, the power key indicator will flash red,
and the battery box on the instrument screen will flash.
When the battery is fully charged, the instrument will automatically stop charging and
the power key indicator will be turned off.
When the battery box at the upper right corner of the screen is displayed as a red box,
it indicates that the battery is about to run out.
4.5.4 Set System Language
This product supports multiple languages. You can click System>Language> to
This chapter describes the front and rear panels and user interface of the instrument.
4.6.1 Front panel
Figure 4 Front Panel
1 Display screen
2.8 inch TFT LCD.
2 Menu keys
It corresponds to the four menus displayed below the LCD screen.
3 Material type key
Switch the measured material types, including steel and cast steel, alloy tool steel,
stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy,
copper tin alloy, pure copper and forged steel.
Switch the hardness system, including Leeb (HL), Brinell (HB), Rockwell B (HRB),
Rockwell C (HRC), Rockwell A (HRA), Vickers (HV) and Shore (HS).
6 Impact direction key
Switch the direction of impact.
7 Power key
Press the key when the machine is turned off, and the instrument will be turned on;
Press the key when the machine is turned on, and the instrument will be turned off.
8 Printing shortcut key
Quickly print the current measurement.
9 Direction key
Used to move cursor position and change settings.
10 Esc
When printing multiple groups of data, printing can be stopped before completed.
11 Measurement times key
Change the number of measurements from 1 to 32.
12 Delete key
During the measurement, press this key
to delete the current measurement value.
13 Confirm key
14 Next Page
In the main interface, press this key to turn to the next page.
15 Save key
When automatic storage is closed, after measuring a group of data, press this button to
save the current measured value. If the current data has not been measured, it cannot
be saved.
Press the System>Userbutton to enter the user system and
change the time. When the battery is removed, the time and
date will return to their original values.
Electricity
surplus
Prompt the remaining power. When the battery icon is red,
it indicates that the battery is low. Please charge the
instrument in time.
Charging power supply: 5V/2A; The charging time is about
6 hours;
The continuous working time shall not be less than 80
hours (25 ℃ without Bluetooth);
EN
1 Status display
Table 2 User Interface
2 Functional area
The function area is displayed when the machine is turned on.
3 Menu area
Press to select the corresponding menu.
4.7 Battery
4.7.1 Battery storage
Lithium ion batteries can be stored in clean, dry and ventilated rooms. Avoid contact
with corrosive substances and keep away from fire and heat sources.
If the instrument is not used for a long time (more than 6 months), the battery should be
taken out of the instrument and stored in a dry and cool environment with 50% ~70% of
the power.
If the lithium battery is damaged, rusted, leaking, swollen, etc., it shall be taken out
immediately and scrapped.
4.7.2 Battery replacement
The battery can be recharged repeatedly, but it is a consumable. If the standby time is
greatly reduced, the battery needs to be replaced. The battery specification is 18650
lithium battery, 3.7V, 2600mAh.
Please refer to the following steps for replacement:
Pay attention to the positive and negative pole of the battery when replacing the
battery.
4.8 Safety lockhole
A safety lockhole is reserved on the back shell of the instrument, and users need to
purchase a safety lock by themselves. Wrap one end of the safety lock around an
object that is difficult to move, insert the other end into the safety lock hole, turn the key
After the instrument is started, it will enter the measurement interface. If it is in any
other interface, just press to enter the measurement interface;
Each time the material is switched, the hardness scale is changed to Leeb, so the
material should be set first and then the hardness scale;
Under normal conditions, the current measured value cannot be stored when the set
number of impacts is not reached;
The measurement interface mainly displays the measuring impact device, measuring
material, current measured value, measuring times and average value. When the
measurement times reach the set number, the average value changes from white to
green. The display page is as follows:
Figure 5 Measurement Interface
1 Impact device
The instrument supports 5 types of impact devices, namely D, DC, DL, D+15 and G,
which are automatically identified during replacement, and no calibration is required.
2 Measuring direction
It supports vertical downward, oblique downward, horizontal, oblique upward and
vertical upward.
3 Measuring average
4 Measuring materials
The measured materials include steel and cast steel, alloy tool steel, stainless steel,
gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy (brass), copper tin
alloy (bronze), pure copper and forged steel.
Set the average number of times. When the
number of measurements reaches the
EN
Switch the hardness scale, including Leeb (HL), Brinell (HB), Rockwell B (HRB),
Rockwell C (HRC), Rockwell A (HRA), Vickers (HV) and Shore (HS).
6 Current measured value
7 Times of measurement/total times of measurement
When the number of measurements reaches the set number, the average value
changes from white to green.
5.2 System settings
After the instrument is started and enter the<Main Interface>, press the System button
to enter the<System>.
On the System page, language, sound, backlight brightness, backlight time, automatic
shutdown, date and time can be set.
5.3 Measurement
Select Measure in the main interface to enter the<Measure>interface.
average number, the average value is
displayed in green. Continue measuring will
result in recount.
Material
(Cast)Steel
CWT. steel
Stainless steel
Grey cast iron
Ductile iron
Cast aluminum alloy
Copper zinc alloy
Copper tin alloy
Pure copper
Forged steel
Switch the type of material being
measured.
Scale
HL
HB
HRB
HRC
HRA
HV
HS
Change the hardness scale
Function
Settings
Description
Auto Save
ON
OFF
When automatic storage is on, the measured values
will be automatically stored in the selected storage
group after each measurement, and each storage
group can store 50 data. When the current storage
group is full, the instrument will remind you to switch to
the next storage group.
When the automatic storage is off, after a
measurement is completed, press to save the
measured value, otherwise the measured value will not
be saved.
Store Set
1-10
After each measurement, the data is stored in this
storage group.
Browse Set
1-10
Select a group to browse data.
Delete Set
1-10
Select a group to delete data.
EN
Table 51 Measurement menu functions
5.4 Save
Select Save in the main interface to enter the <Save> interface.
There are 10 storage groups in total. Each storage group can store 50 data, and a
In the main interface, Pgdn > Info to enter the<Information>interface.
Display the instrument model, serial number, hardware version, software version and
whether Bluetooth printing is supported.
5.6 Calibration
In the main interface, Pgdn >Cal to enter the<Calibrate>interface.
If the instrument is used for the first time or not used for a long time, the instrument and
impact device must be calibrated with a random Leeb hardness block. The number of
measurements is 5, and the displayed value is the average value. Press to
adjust.
Press theSave key to complete the calibration, and press theBack key to cancel the
calibration. The calibration range is ± 15HL.
Displays the connection status between the instrument and
the printer.
Curr Value
Print the current measured value. If the current measurement
is not completed, prompt "Measurement is not completed" and
no printing will be performed.
Group Set
Press to select one of the 10 groups.
Value Set
Select some values to print in some print groups.
Print All
Print all the values in all print groups selected
EN
Figure5 Printing Paper
1 Printer: Press the power on key , and the indicator will flash blue.
2 Hardness tester: Main interface > Print > Connect, the instrument displays
"Connecting the printer...". At this time, the instrument cannot be operated. After about
one minute, when the printer successfully connects to the device, the printer blue light
is off, printing can be performed.
During printing of multiple measured values, press to stop the current printing.
Table 5 Print menu functions
5.8 Firmware upgrade
1. Download and install the burning tool "DfuSe Demo v3.0.5". Download the upgrade
package (* * *. dfu).
2. In the shutdown state, insert the USB cable into the Type C port of the instrument,
and the instrument is connected to the computer. Keep holding down the key,
gently press the power key and release it. At this time, the indicator light in the lower
right corner starts flashing red and green, indicating that the instrument has entered the
Dfu mode. Release F1 key.
Users can download the application software of the instrument on the official
website of Hantek:
http://hantek.com/products/detail/18195
You can also scan the QR code on the back of the instrument for downloading.
Open the "HT360" application and use it directly without installing it.
Press the power key to turn on the instrument.
Connect the instrument to a Windows computer using a USB cable to communicate via
USB.
After selecting a group of measured values to load, the specific value of a measured
number is represented by a histogram.
2. Loading details
The measured data, including material, impact angle, hardness scale, impact device,
impact times, specific value, maximum value, minimum value, average value and test
date, shall be displayed as a whole.
3. Connection status
When the device connection is successful, "Device connected" is displayed. The
previous time is the time when the device was connected. When the device is
disconnected, "Device disconnected" is displayed. The previous time is the time when
the device was disconnected.
4. Control area
Load: load the data of the above selected group.
Save as CSV: Export the load group data, including material, impact angle,
hardness scale, impact device, impact number, specific value, maximum value,
minimum value, average value and test date, as a CSV file.
Save as PDF: Export the histogram to a PDF file.
Print Preview
Print: Print the currently loaded group data.
Qingdao Hantek Electronics Co., Ltd. (hereinafter referred to as Hantek) promises that
the mainframe and accessories of its production instruments will be free from any
material and process defects within the product warranty period.
During the warranty period, if the product is proved to be defective, Hantek will repair or
replace it for free. For detailed warranty regulations, please refer to Hantek's official
website or product warranty card. For the full text of the repair service or warranty
instructions, please contact the Hantek repair center or local offices.
Except for the warranty provided in this summary or other applicable warranty cards,
Hantek does not provide any other express or implied warranty, including but not limited
to any implied warranty on the product's tradability and applicability for special
purposes. In no event shall Hantek be liable for indirect, special or consequential
losses.