Hantek HT360C User guide

Page 1
HT360 Series
Leeb Hardness Tester
User Manual
2022.12
Page 2
Warranties and Representations
Copyright
The copyright of this document belongs to Qingdao Hantek Electronics Co., Ltd.
Statement
Qingdao Hantek Electronics Co., Ltd. reserves the right to modify this document without notice. Qingdao Hantek Electronics Co., Ltd. promises that the information provided is correct and reliable but does not guarantee that this document is error-free. Before using this product, please make sure that the relevant technical document is the latest and valid version. If your company uses the documents or products of Qingdao Hantek Electronics Co., Ltd. and requires the cooperation of a third party's products, patents or works, your company shall be responsible for obtaining the consent and authorization of the third party. The above consent and authorization are not the responsibility of the Hantek.
Product certification
Hantek certifies HT360 series leeb hardness tester to meet China national industry standards, has passed the CE certification, and will further complete the certification of other national standards.
Contact us
If you have any questions when using the products of Qingdao Hantek Electronics Co., Ltd., you can obtain services and support through the following ways: Mail box: service@hantek.com support@hantek.com Website: http://www.hantek.com
Page 3
EN
Catalog
Catalog............................................................................................................................................. I
Illustrations List ............................................................................................................................ IV
List of Tables .................................................................................................................................. I
1 Safety requirements ............................................................................................................. 1
1.1 General security issues .............................................................................................................1
1.2 Safety terms and symbols .........................................................................................................2
1.3 Working environment .................................................................................................................2
1.4 Maintenance and cleaning ........................................................................................................4
1.5 Environmental precautions .......................................................................................................5
2 Product features .................................................................................................................... 6
3 Document Overview ............................................................................................................. 8
4 Quick Start .............................................................................................................................. 9
4.1 General inspection ......................................................................................................................9
4.2 Appearance and dimension ......................................................................................................9
4.3 D-type impact device ............................................................................................................... 10
4.4 Profiled impact device ............................................................................................................. 10
4.5 Preparation before use ........................................................................................................... 12
4.5.1 Measurement ................................................................................................................................... 13
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
I
Page 4
EN
4.5.2 Adjusting the support ...................................................................................................................... 14
4.5.3 Charge ............................................................................................................................................... 15
4.5.4 Set System Language .................................................................................................................... 15
4.6 Product introduction ................................................................................................................. 16
4.6.1 Front panel ........................................................................................................................................ 16
4.6.2 Side panel ......................................................................................................................................... 18
4.6.3 Top panel .......................................................................................................................................... 18
4.6.4 User interface ................................................................................................................................... 18
4.7 Battery ......................................................................................................................................... 19
4.7.1 Battery storage ................................................................................................................................ 19
4.7.2 Battery replacement ....................................................................................................................... 19
4.8 Safety lockhole ......................................................................................................................... 21
5 Function introduction .......................................................................................................... 23
5.1 Measuring interface ................................................................................................................. 23
5.2 System settings ........................................................................................................................ 24
5.3 Measurement ............................................................................................................................ 24
5.4 Save ............................................................................................................................................ 25
5.5 Information ................................................................................................................................. 26
5.6 Calibration .................................................................................................................................. 26
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
II
Page 5
EN
5.7 Printing ........................................................................................................................................ 26
5.8 Firmware upgrade .................................................................................................................... 27
6 Windows software .............................................................................................................. 28
6.1 Software download and installation ..................................................................................... 28
6.1.1 Software function............................................................................................................................. 28
7 Troubleshooting .................................................................................................................. 30
8 Attached table ...................................................................................................................... 31
8.1 Attached table 1 ........................................................................................................................ 31
8.2 Attached table 2 ........................................................................................................................ 32
8.3 Attached table 3 ........................................................................................................................ 33
8.4 Attached table 4 ........................................................................................................................ 35
9 Appendix ............................................................................................................................... 36
9.1 Appendix A: Accessories and Options ................................................................................ 36
9.2 Appendix B: Warranty Summary .......................................................................................... 37
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
III
Page 6
EN
Illustrations List
Figure 3.1 Model .................................................................................................................... 8
Figure 4.1 Front view and side view ................................................................................. 9
Fig. 4.2 D-type impact device ........................................................................................... 10
Fig. 4.3 Profiled impact device ......................................................................................... 10
Fig. 4.4 Output signal of impact device .......................................................................... 11
Figure 4.5 Curved sample face ........................................................................................ 12
Figure 4.6 Loading .............................................................................................................. 13
Figure 4.7 Adjusting the support ...................................................................................... 15
Figure 4.8 Front Panel ....................................................................................................... 16
Figure 4.9 Side Panel ......................................................................................................... 18
Figure 4.10 Top panel ......................................................................................................... 18
Figure 4.11 User Interface ................................................................................................. 18
Figure 4.12 Opening the support ..................................................................................... 20
Figure 4.13 Installing the Battery ..................................................................................... 21
Figure 4.14 Safetyt Lockhole ............................................................................................ 22
Figure 5.1 Measurement Interface .................................................................................. 23
Figure 5.2 Printer ................................................................................................................. 26
Figure 5.3 Printing Paper ................................................................................................... 27
Figure. 6.1 Connection diagram ....................................................................................... 28
Figure. 6.2 Upper computer user interface .................................................................... 29
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
IV
Page 7
EN
List of Tables
Table 4.1 Display error and repeatability ....................................................................... 11
Table 4.2 Measurement ..................................................................................................... 14
Table 4.3 User Interface ..................................................................................................... 19
Table 5.1 System menu functions .................................................................................... 24
Table 5.2 Measurement menu functions ........................................................................ 25
Table 5.3 Storage menu functions ................................................................................... 26
Table 5.4 Print menu functions ......................................................................................... 27
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
I
Page 8
Page 9
Safety requirements
EN
1 Safety requirements
1.1 General security issues
Read the following safety precautions carefully to avoid injury and to prevent damage to this product or any product connected to this product. To avoid possible hazards, be sure to use this product as prescribed.
Only professionally authorized personnel should perform maintenance.
Check all terminal ratings.
To avoid fire or shock from excessive current, check all ratings and symbols on the product. Consult the product manual for rating details before connecting the product.
Do not operate with the cover open.
Do not run the product with the outer cover or panel open.
Do not operate the product when you suspect it is faulty.
If you suspect this product has been damaged, ask a qualified repairman to inspect it.
Maintain proper ventilation.
Do not operate in a humid environment.
Do not operate in a flammable or explosive environment.
Please keep the product surface clean and dry.
Antistatic protection.
Static electricity may cause damage to the instrument. Test in an anti-static area as far as possible. Before connecting the cable to the instrument, the inner and outer conductors should be grounded briefly to release static electricity.
Use the batteries properly.
If batteries are provided, do not expose the batteries to high temperature or fire. Keep batteries away from children. Replacing the battery incorrectly can cause an explosion (warning: lithium-ion batteries). Only use batteries specified for this product.
Warning:
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
1
Page 10
Safety requirements
Warning
EN
Devices that meet Class A requirements may not provide adequate protection for
broadcast services in the residential environment.
1.2 Safety terms and symbols
Safety terms in this manual:
Danger:
Indicate that you may cause immediate damage if you perform this operation.
Warning:
Indicate that it may not cause immediate damage to you if you perform this
operation.
Note:
Indicate that you may cause damage to this product or other properties if you
perform this operation.
Safety symbols on the product:
1.3 Working environment
Temperature
Operating temperature: 0 - 45 Storage temperature: -20 - 60
Humidity
≤+104 °F (≤+40 °C): relative humidity ≤ 90%
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
2
Page 11
Safety requirements
EN
106 °F ~ 122 °F (+41 °C~45 °C): relative humidity ≤ 60% The surrounding environment is free of vibration, strong magnetic field, corrosive medium and serious dust.
Warning:
To avoid the risk of short circuit or electric shock in the internal circuit, do not
operate in a humid environment.
Altitude
When operating and not operating: 3000m (10000 feet).
Random vibration: 0.31 g RMS at 50Hz to 500Hz, 10 minutes per axial direction. When not operating: 2.46g RMS from 5Hz to 500Hz, 10 minutes per axial direction.
Installation (overvoltage) category
This product is powered by a main power supply conforming to installation (overvoltage) category II.
Warning:
Ensure that no over-voltage (such as lightning) reaches the product. Otherwise,
operators may be exposed to electric shock.
Definition of install (overvoltage) category
Installation (overvoltage) class I is the signal level that applies to the measuring terminal of the device connected to the source circuit, where measures have been taken to limit the instantaneous voltage to a correspondingly low level. Installation (overvoltage) class II refers to the local distribution level, which is applicable to devices connected to the mains (AC power supply).
Degree of pollution
2 class
Definition of pollution level
Pollution Level 1: No pollution, or only dry non-conductive pollution. This level of
contamination has no effect. Examples: clean rooms or office with air conditioning.
Pollution level 2: Generally only dry non-conductive pollution occurs. Temporary
conduction due to condensation may sometimes occur. Examples: general indoor
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
3
Page 12
Safety requirements
EN
environments.
Pollution level 3: Conductive pollution occurs, or dry non-conductive pollution
becomes conductive due to condensation. Examples: sheltered outdoor
environment.
Pollution Level 4: Permanent conductive contamination through conductive dust,
rain or snow. Examples: outdoor sites.
Security level
Level 1 - Grounded product
1.4 Maintenance and cleaning
Maintenance:
Do not expose the LCD to direct sunlight for a long time when storing or placing the hardness tester.
Cleaning:
Check the instrument frequently according to the requirements of operating conditions, and clean the external surface according to the following steps:
1) Use a lint free rag to remove the floating dust on the outside of the hardness tester. Be careful to avoid scratching the bright filter material of the display.
2) Clean the hardness tester with a soft cloth soaked in water. For more thorough cleaning, use a 75% isopropyl alcohol water solvent.
Note:
To avoid damaging the surface of the instrument, do not use any corrosive reagents or chemical cleaning reagents.
Warning:
Before reenergizing, please make sure that the instrument is dry to avoid electrical
short circuit or personal injury caused by moisture.
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
4
Page 13
Safety requirements
EN
1.5 Environmental precautions
The following symbols indicate that this product complies with the requirements of WEEE Directive 2002/96/EC.
Equipment recycling:
The production of this equipment requires the extraction and use of natural resources. If the product is discarded improperly, some substances contained in the equipment may be harmful to the environment or human health. In order to avoid releasing harmful substances into the environment and reduce the use of natural resources, it is recommended to adopt appropriate methods to recycle this product to ensure that most materials can be reused correctly.
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
5
Page 14
Product features
EN
2 Product features
Product features
Apply Leeb hardness measurement principle to measure various metal materials,
including steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy, copper tin alloy, pure copper, forged steel, etc;
Realize the mutual conversion between seven kinds of hardness scales: Leeb
(HL), Brinell (HB), Rockwell B (HRB), Rockwell C (HRC), Rockwell A (HRA), Vickers (HV) and Shore (HS);
Support tests in 5 different directions, including vertical downward, oblique
downward, horizontal, oblique upward and vertical upward;
Equipped with D-type impact device, which supports DC, DL, D+15, G and other
types of impact devices;
Support Windows connection, equipped with USB Type-C interface, which can
easily and quickly exchange data with PC;
Adopt 2.8-inch color display which can provide informative and intuitive content;  The instrument is powered by rechargeable lithium battery, which can work
continuously for no less than 80 hours. The long-life and environmentally-friendly battery has power saving functions such as backlight time adjustment and automatic shutdown;
Chinese and English display, which is simple and convenient;  Large capacity memory, which can store 500 data of single measurement value of
the host, including measurement value, average value, measurement date, impact direction, times, materials, hardness system and other information;
Applicable to quality control of heat treated workpieces, rapid inspection of
workpieces with small test space such as installed mechanical or permanent assembly parts and mold cavities, rapid inspection of multiple parts of large workpieces, failure analysis of pressure vessels, steam turbine generators and other equipment, the material differentiation of bearing and other parts production lines, metal material warehouses, production line of bearing and other components, material differentiation of metal material warehouse, and hardness testing of machine tool guides and automobile chassis.
HT360 series portable hardness tester adopts Leeb hardness measurement principle to detect metal hardness, which can measure various metal materials including steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy, copper tin alloy, pure copper, forged steel, etc; Realize the mutual conversion between seven hardness scale, including Leeb (HL), Brinell (HB), Rockwell B (HRB), Rockwell C (HRC), Rockwell A (HRA), Vickers (HV) and Shore (HS). Adopt streamlined ergonomic structure design, equip with a support, and adopt 2.8 inch high-definition display screen, which can display rich and intuitive information; Equip with a large capacity memory, which can store up to 500 data. Support the optional
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
6
Page 15
Product features
EN
Bluetooth printer, which is convenient for users to output test results; Support Windows program control connection to facilitate the storage, export and printing of computer data.
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
7
Page 16
Document Overview
Model
Bluetooth
HT360
No
HT360C
Yes
EN
3 Document Overview
This document is used to guide users to quickly understand the front panel, side panel, user interface and basic operation methods of HT360 series Leeb hardness tester.
Tips:
The latest version of this manual can be accessed at (http://www.hantek.com).
Software version:
Software upgrade may change or add product features. Please follow the Hantek website for the latest version.
Document format convention:
Key
Use icons to represent the front panel buttons. For example, represents the "Scale" button.
1 Menu
Use "menu text (bold)+color (blue)" to indicate a menu option. For example, Measure means clicking the "Measure" option on the current operation interface to enter function configuration menu of “Measure”.
2 Operating Steps
Use the arrow ">" to indicate the next operation. For example, Print>Connect means click Print and then click Connect.
Document content convention:
HT360 series Leeb hardness tester includes the following models. Unless otherwise specified, this manual takes HT360C as an example to explain HT360 series and its basic operation.
Figure 1 Model
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
8
Page 17
Quick Start
EN
4 Quick Start
4.1 General inspection
Check the transport package
After receiving the hardness tester, users should check the equipment according to the following steps: check whether there is any damage caused by transportation: if the packaging carton or foam plastic protective pad is seriously damaged, please keep it until the whole machine and accessories pass the electrical and mechanical tests.
Check the accessories
The details of the accessories provided are described in "Appendix A: Accessories and
Options" at the end of this manual. If the accessories are found missing or damaged,
please contact the dealer responsible for this business.
Check the whole machine
If the appearance of the instrument is damaged, the instrument does not work properly, or fails to pass the performance test, please contact the dealer in charge of this business.
4.2 Appearance and dimension
Figure 41 Front view and side view
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
9
Page 18
Quick Start
1 Supporting ring
5 Conduit
2 Impact body
6 Loading set
3 Coil
7 Release button
4 Conductor
EN
4.3 D-type impact device
Fig. 2 D-type impact device
4.4 Profiled impact device
Fig. 43 Profiled impact device
Working principle
Impact the sample surface with an impact body with specified mass at a certain speed
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
10
Page 19
Quick Start
Serial No
Impact device type
Hardness value of standard Leeb hardness block
Indication error
Repeatability of indication
1
D
760±30HLD 530±40HLD
±6 HLD ±10 HLD
6 HLD 10 HLD
2
DC
760±30HLDC 530±40HLDC
±6 HLDC ±10 HLDC
6 HLD 10 HLD
3
DL
878±30HLDL 736±40HLDL
±12 HLDL
12 HLDL
4
D+15
766±30HLD+15 544±40HLD+15
±12 HLD+15
12 HLD+15
5
G
590±40HLG 500±40HLG
±12 HLG
12 HLG
6
E
725±30HLE 508±40HLE
±12 HLE
12 HLE
7
C
822±30HLC 590±40HLC
±12 HLC
12 HLC
EN
under the effect of elastic force, and calculate the hardness value with the ratio of the rebound speed and impact speed of the punch at a distance of 1mm from the sample surface. The calculation formula is as follows: HL=1000 * VB/VA Where: HL - Leeb hardness value VB -- Rebound speed of impact body VA - Impact velocity of impact body The output signal of the impact device is shown in the following diagram:
Fig. 4 Output signal of impact device
Technical characteristics
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
Table 41 Display error and repeatability
This series of hardness tester meets the following standards
1. GB/T 17394. 1-2014 Leeb Hardness Test for Metallic Materials Part 1: Test Method
2. GB/T 17394. 2-2012 Leeb Hardness Test for Metallic Materials Part 2: Verification and Calibration of Hardness Tester
11
Page 20
Quick Start
EN
3. GB/T 17394.3-2012 Leeb Hardness Test for Metallic Materials Part 4: Calibration of Standard Hardness Blocks
4. GB/T 17394. 4-2014 Leeb Hardness Test for Metallic Materials Part 4: Standard Value Conversion Table
5. Design basis and standard: Technical Conditions for Leeb Hardness Tester JB/T 9378-2001
4.5 Preparation before use
Preparation of sample surface
When preparing the sample surface, the influence of heating and cold working on the sample surface hardness shall be avoided as far as possible. If the measured surface is too rough, measurement error will be caused. Therefore, the tested surface must show metallic luster and be flat, smooth and free of oil stain. Curved surface: The test surface is better to be flat. When the curvature radius R of the tested surface is less than 30mm (type D, DC, D+15, C, E, DL impact devices) and less than 50mm (type G impact devices), small support rings or profiled support rings should be used for testing.
Figure 4 Curved sample face
Support of sample
1. No support is required for heavy samples;
2. For medium-sized samples, they must be placed on a flat and firm plane. The samples should be placed stably without any shaking;
3. The sample shall have sufficient thickness, and the minimum thickness of the sample shall comply with Table 3;
4. For the samples with surface hardening layer, the depth of hardening layer shall comply with Table 3.
Coupling
1. For the light sample, it must be tightly coupled with the solid support, the two coupling surfaces must be flat and smooth, the amount of coupling agent must not be too much, and the test direction must be perpendicular to the coupling plane;
2. When the sample is a large area plate, long rod or bending piece, if the weight and thickness are too large, it may cause distortion and instability of the sample, leading to
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
12
Page 21
Quick Start
EN
inaccurate test values, so it should be reinforced or supported at the back of the test point;
3. The magnetism of the sample should be less than 30 Gauss.
4.5.1 Measurement
Before measurement, random hardness block can be used to inspect the
instrument, and its display error and repeatability shall not be greater than those
specified in Table 4.1.
1. Booting
a. Insert the impact device plug into the impact device socket on the upper side of the instrument; b. Press the key. When the power is on, the instrument enters the measurement state.
2. Loading
Figure 4 Loading
Push the loading sleeve downward to lock the impact body; For DC-type impact
device, place the loading bar on the test surface, insert the DC-type impact device
into the loading bar until its stop position, and then the loading is completed.
Press the support ring of the impact device tightly on the surface of the sample, and the impact direction should be perpendicular to the test surface.
3. Measuring
Press the release button on the upper part of the impact device to measure. At this
time, the sample, impact device and operator shall be stable, and the force direction shall pass through the axis of the impact device;
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
13
Page 22
Quick Start
Impact device type
The distance between two indentation centers is not less than (mm)
The distance between the indentation center and the sample edge is not less than (mm)
DDC
3 5 DL 3 5
D+15
3
5
G 4 8
E 3 5
C 2 4
EN
Each measuring part of the sample is generally tested for five times. The data
dispersion shall not exceed ± 15HL of the average value;
The distance between any two indentations or the distance from the center of any
indentation to the edge of the sample shall comply with Table 4.2
For a specific material, in order to convert the Leeb hardness value to other
hardness values more accurately, a comparison test must be conducted to obtain the corresponding conversion relationship. The method is: use qualified Leeb hardness tester and corresponding hardness tester to test on the same sample respectively. For each hardness value, measure five Leeb hardness values evenly around more than three hardness indentations that need to be converted. Use the average Leeb hardness value and the average corresponding hardness value as the corresponding values, and make a hardness comparison curve. The comparison curve shall include at least three groups of corresponding data.
Table 4 Measurement
4. Read the measured value
Take average value of several valid test points as one Leeb hardness test data.  Display the hardness value in front of the Leeb hardness symbol HL. The HL
values measured by different types of impact devices are different.
4.5.2 Adjusting the support
When using the instrument, the user can open the standing foot as a support to tilt the instrument upward for easy operation and observation. When the instrument is not in use, the user can close the support to facilitate placing or moving.
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
14
Page 23
Quick Start
EN
Figure 45 Adjusting the support
4.5.3 Charge
If the power key is pressed but the instrument does not respond, the battery may be depleted.
You can charge the instrument as follows:
Method 1: Charge the instrument through the power adapter
Connect the instrument to the power socket through the standard power adapter (5V/2A) and Type-C data cable for charging.
Method 2: Charge the instrument through Type-C interface
Connect the instrument to the computer or other equipment (5V/500mA) through Type-C data cable for charging.
Charging state description:
When the battery is installed during charging, the indicator light of the power key is red, and the battery box at the upper right corner of the instrument screen displays the change of power. If the battery is not installed, the power key indicator will flash red, and the battery box on the instrument screen will flash. When the battery is fully charged, the instrument will automatically stop charging and the power key indicator will be turned off. When the battery box at the upper right corner of the screen is displayed as a red box, it indicates that the battery is about to run out.
4.5.4 Set System Language
This product supports multiple languages. You can click System>Language> to
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
15
Page 24
Quick Start
EN
set the system language.
4.6 Product introduction
This chapter describes the front and rear panels and user interface of the instrument.
4.6.1 Front panel
Figure 4 Front Panel
1 Display screen
2.8 inch TFT LCD.
2 Menu keys
It corresponds to the four menus displayed below the LCD screen.
3 Material type key
Switch the measured material types, including steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy, copper tin alloy, pure copper and forged steel.
4 Main interface key
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
16
Page 25
Quick Start
EN
Press this key to return to the main interface.
5 Hardness scale key
Switch the hardness system, including Leeb (HL), Brinell (HB), Rockwell B (HRB), Rockwell C (HRC), Rockwell A (HRA), Vickers (HV) and Shore (HS).
6 Impact direction key
Switch the direction of impact.
7 Power key
Press the key when the machine is turned off, and the instrument will be turned on; Press the key when the machine is turned on, and the instrument will be turned off.
8 Printing shortcut key
Quickly print the current measurement.
9 Direction key
Used to move cursor position and change settings.
10 Esc
When printing multiple groups of data, printing can be stopped before completed.
11 Measurement times key
Change the number of measurements from 1 to 32.
12 Delete key
During the measurement, press this key to delete the current measurement value.
13 Confirm key
14 Next Page
In the main interface, press this key to turn to the next page.
15 Save key
When automatic storage is closed, after measuring a group of data, press this button to save the current measured value. If the current data has not been measured, it cannot be saved.
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
17
Page 26
Quick Start
EN
4.6.2 Side panel
Figure 4 Side Panel
Type-C interface
Connect Type-C cable for charging and computer upgrading.
4.6.3 Top panel
Figure 46 Top panel
Impact device socket
Connect the impact device.
4.6.4 User interface
Figure 4 User Interface
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
18
Page 27
Quick Start
Status display
Sign
Description
Time
Instrument time
Press the System>User button to enter the user system and change the time. When the battery is removed, the time and date will return to their original values.
Electricity surplus
Prompt the remaining power. When the battery icon is red, it indicates that the battery is low. Please charge the instrument in time. Charging power supply: 5V/2A; The charging time is about 6 hours; The continuous working time shall not be less than 80 hours (25 without Bluetooth);
EN
1 Status display
Table 2 User Interface
2 Functional area The function area is displayed when the machine is turned on.
3 Menu area Press to select the corresponding menu.
4.7 Battery
4.7.1 Battery storage
Lithium ion batteries can be stored in clean, dry and ventilated rooms. Avoid contact with corrosive substances and keep away from fire and heat sources. If the instrument is not used for a long time (more than 6 months), the battery should be taken out of the instrument and stored in a dry and cool environment with 50% ~70% of the power. If the lithium battery is damaged, rusted, leaking, swollen, etc., it shall be taken out immediately and scrapped.
4.7.2 Battery replacement
The battery can be recharged repeatedly, but it is a consumable. If the standby time is greatly reduced, the battery needs to be replaced. The battery specification is 18650 lithium battery, 3.7V, 2600mAh.
Please refer to the following steps for replacement:
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
19
Page 28
Quick Start
EN
1 Open the support and you can see two screws. Remove the screws and remove
the battery cover to see the battery.
Figure 47 Opening the support
2 Please take out the battery from the negative pole, and take out the whole
battery after the negative pole leaves.
3 When installing the battery, make sure that the positive pole of the battery has an
insulating tube, otherwise, please refer to the following steps to install the
insulating heat shrink tube.
1) Prepare insulating heat shrink tube of the following sizes. Size: thickness 0.2~0.3mm, inner diameter 18~19mm, length 21mm.
2) Put it on the positive pole of the battery.
3) Use a hot air gun with the temperature of 270 ° to blow the tube for 5 seconds to
make the heat shrink tube stick to the battery.
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
20
Page 29
Quick Start
EN
4 Install the battery.
Figure 48 Installing the Battery
Note:
Pay attention to the positive and negative pole of the battery when replacing the
battery.
4.8 Safety lockhole
A safety lockhole is reserved on the back shell of the instrument, and users need to purchase a safety lock by themselves. Wrap one end of the safety lock around an object that is difficult to move, insert the other end into the safety lock hole, turn the key
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
21
Page 30
Quick Start
EN
clockwise to lock the instrument, and then pull out the key. In this way, the most basic anti-theft requirements can be met.
Figure 49 Safetyt Lockhole
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
22
Page 31
Function introduction
EN
5 Function introduction
5.1 Measuring interface
After the instrument is started, it will enter the measurement interface. If it is in any other interface, just press to enter the measurement interface; Each time the material is switched, the hardness scale is changed to Leeb, so the material should be set first and then the hardness scale; Under normal conditions, the current measured value cannot be stored when the set number of impacts is not reached; The measurement interface mainly displays the measuring impact device, measuring material, current measured value, measuring times and average value. When the measurement times reach the set number, the average value changes from white to green. The display page is as follows:
Figure 5 Measurement Interface
1 Impact device
The instrument supports 5 types of impact devices, namely D, DC, DL, D+15 and G, which are automatically identified during replacement, and no calibration is required.
2 Measuring direction
It supports vertical downward, oblique downward, horizontal, oblique upward and vertical upward.
3 Measuring average
4 Measuring materials
The measured materials include steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy (brass), copper tin alloy (bronze), pure copper and forged steel.
5 Hardness scale
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
23
Page 32
Function introduction
Function
Settings
Description
Language
Chinese English
Set the menu language.
Backlight
1-10
Set the screen backlight brightness.
BL time
30s 60s 90s 120s OFF
Set the backlight time of the screen. The screen backlight will be dimmed within a specified time if no key is operated.
APO Time
5min 10min 30min OFF
Set the automatic shutdown time. The instrument will automatically shut down within the specified time if no key is not operated.
Beeper
ON OFF
Turn key sound on or off.
Date Time
- -
When the battery is removed, the time and date will return to their original values.
Function
Settings
Description
Direction
Downward Inclined dowm Horizontal CLB climb Upward
Select the direction of impact. Times
1-32
Set the average number of times. When the number of measurements reaches the
EN
Switch the hardness scale, including Leeb (HL), Brinell (HB), Rockwell B (HRB), Rockwell C (HRC), Rockwell A (HRA), Vickers (HV) and Shore (HS).
6 Current measured value
7 Times of measurement/total times of measurement
When the number of measurements reaches the set number, the average value changes from white to green.
5.2 System settings
After the instrument is started and enter the<Main Interface>, press the System button to enter the<System>. On the System page, language, sound, backlight brightness, backlight time, automatic shutdown, date and time can be set.
5.3 Measurement
Select Measure in the main interface to enter the<Measure>interface.
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
24
Table 5 System menu functions
Page 33
Function introduction
Function
Settings
Description
average number, the average value is displayed in green. Continue measuring will result in recount.
Material
(CastSteel CWT. steel Stainless steel
Grey cast iron Ductile iron Cast aluminum alloy Copper zinc alloy Copper tin alloy Pure copper Forged steel
Switch the type of material being measured.
Scale
HL HB HRB HRC HRA HV HS
Change the hardness scale
Function
Settings
Description
Auto Save
ON OFF
When automatic storage is on, the measured values will be automatically stored in the selected storage group after each measurement, and each storage group can store 50 data. When the current storage group is full, the instrument will remind you to switch to the next storage group. When the automatic storage is off, after a measurement is completed, press to save the measured value, otherwise the measured value will not be saved.
Store Set
1-10
After each measurement, the data is stored in this storage group.
Browse Set
1-10
Select a group to browse data.
Delete Set
1-10
Select a group to delete data.
EN
Table 51 Measurement menu functions
5.4 Save
Select Save in the main interface to enter the <Save> interface.
There are 10 storage groups in total. Each storage group can store 50 data, and a
total of 500 data can be stored.
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
25
Page 34
Function introduction
Function
Settings
Description
Delete All
- -
Delete all data in ten groups.
EN
Table 52 Storage menu functions
5.5 Information
In the main interface, Pgdn > Info to enter the<Information>interface. Display the instrument model, serial number, hardware version, software version and whether Bluetooth printing is supported.
5.6 Calibration
In the main interface, Pgdn >Cal to enter the<Calibrate>interface. If the instrument is used for the first time or not used for a long time, the instrument and impact device must be calibrated with a random Leeb hardness block. The number of measurements is 5, and the displayed value is the average value. Press to adjust. Press the Save key to complete the calibration, and press the Back key to cancel the calibration. The calibration range is ± 15HL.
5.7 Printing
Only HT360C supports printing.
Figure 5 Printer
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
26
Page 35
Function introduction
Function
Description
Link State
Displays the connection status between the instrument and the printer.
Curr Value
Print the current measured value. If the current measurement is not completed, prompt "Measurement is not completed" and no printing will be performed.
Group Set
Press to select one of the 10 groups.
Value Set
Select some values to print in some print groups.
Print All
Print all the values in all print groups selected
EN
Figure5 Printing Paper
1 Printer: Press the power on key , and the indicator will flash blue. 2 Hardness tester: Main interface > Print > Connect, the instrument displays
"Connecting the printer...". At this time, the instrument cannot be operated. After about one minute, when the printer successfully connects to the device, the printer blue light is off, printing can be performed. During printing of multiple measured values, press to stop the current printing.
Table 5 Print menu functions
5.8 Firmware upgrade
1. Download and install the burning tool "DfuSe Demo v3.0.5". Download the upgrade
package (* * *. dfu).
2. In the shutdown state, insert the USB cable into the Type C port of the instrument,
and the instrument is connected to the computer. Keep holding down the key, gently press the power key and release it. At this time, the indicator light in the lower
right corner starts flashing red and green, indicating that the instrument has entered the Dfu mode. Release F1 key.
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
27
Page 36
Windows software
EN
6 Windows software
6.1 Software download and installation
Users can download the application software of the instrument on the official
website of Hantek:
http://hantek.com/products/detail/18195
You can also scan the QR code on the back of the instrument for downloading.
Open the "HT360" application and use it directly without installing it. Press the power key to turn on the instrument. Connect the instrument to a Windows computer using a USB cable to communicate via USB.
Figure. 6 Connection diagram
6.1.1 Software function
User interface
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
28
Page 37
Windows software
EN
Figure. 6 Upper computer user interface
1. Hardness value histogram
After selecting a group of measured values to load, the specific value of a measured number is represented by a histogram.
2. Loading details
The measured data, including material, impact angle, hardness scale, impact device, impact times, specific value, maximum value, minimum value, average value and test date, shall be displayed as a whole.
3. Connection status
When the device connection is successful, "Device connected" is displayed. The previous time is the time when the device was connected. When the device is disconnected, "Device disconnected" is displayed. The previous time is the time when the device was disconnected.
4. Control area
Load: load the data of the above selected group.  Save as CSV: Export the load group data, including material, impact angle,
hardness scale, impact device, impact number, specific value, maximum value, minimum value, average value and test date, as a CSV file.
Save as PDF: Export the histogram to a PDF file.  Print Preview  Print: Print the currently loaded group data.
5. Current date
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
29
Page 38
Troubleshooting
EN
7 Troubleshooting
1. If the power key is pressed, the screen is still black without any display.
1) Plug in the charger. If the instrument is on, the battery is dead or damaged. Charge
or replace the battery.
2) After the above check, restart the instrument.
3) If you still cannot use this product normally, please contact Hantek.
2. The screen display is too dark to see clearly
1) Check whether the brightness value of the LCD screen is too small. Press the
System > Backlight, press the direction keys to select the backlight, and
press to change the brightness of the LCD screen to an appropriate state.
2) Check the backlight time setting. Press System > Backlight, press the direction
keys to select the backlight time, and press to change the screen backlight time.
3. The instrument does not display the measured value
The sensor cable is faulty. Replace the sensor cable.
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
30
Page 39
Attached table
Material
Hardness system
Impact device
D/DC
D+15
C G E
DL
Steel and cast steel
HRC
17.9~68.5
19.3~67.9
20.0~69.5
22.4~70.7
20.6~68.2
HRB
59.6~99.6
47.7~99.9
37.0~99.9
HRA
59.1~85.8
61.7~88.0
HB
127~651
80~638
80~683
90~646
83~663
81~646
HV
83~976
80~937
80~996
84~1042
80~950
HS
32.2~99.5
33.3~99.3
31.8~102.1
35.8~102.6
30.6~96.8
Steel
HB
143~650
CWT ST
alloy tool steel
HRC
20.4~67.1
19.8~68.2
20.7~68.2
22.6~70.2
HV
80~898
80~935
100~941
82~1009
Stainless steel
HRB
46.5~101.7
HB
85~655
HV
85~802
GC. IRON
HRC
HB
93~334
92~326
HV
NC IRON
HRC
HB
131~387
127~364
HV
C.ALUM HB
19~164
23~210
32~168
HRB
23.8~84.6
22.7~85.0
23.8~85.5
BRASS HB
40~173
HRB
13.5~95.3
BRONZE
HB
60~290
Copper
HB
45~315
EN
8 Attached table
8.1 Attached table 1
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
31
Page 40
Attached table
Serial No
Material
Leeb hardness HLD
Strength σ
b
(MPa)
1
C mild steel
350~522
374~ 780
2
C high carbon steel
500~710
737~ 1670 3
Cr
500~730
707~ 1829
4
CrV
500~750
704~ 1980
5
CrNi
500~750
763~ 2007
6
CrMo
500~738
721~ 1875
7
CrNiMo
540~738
844~ 1933
8
CrMnSi
500~750
755~ 1993
9
SSST
630~800
1180~ 2652
10
SST
500~710
703~ 1676
EN
8.2 Attached table 2
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
32
Page 41
Attached table
Profiled impact device
DC (D) /DL
D+15
C
G
E (Import needed)
Impact energy Mass of impact body
11mJ
5. 5g/7.2g
11mJ
7.8g
2.7mJ
3.0g
90mJ
20.0g
11mJ
5.5g
Ball joint hardness: Ball joint diameter: Ball joint material:
1600HV 3mm Tungste n carbide
1600H V 3mm Tungst en carbide
1600H V 3mm Tungst en carbide
1600HV 5mm Tungste n carbide
5000HV 3mm Diamond
Diameter of impact device: Length of impact device: Weight of impact device:
20mm 86(147)/ 75mm 50g
20mm 162m m 80g
20mm 141mm 75g
30mm 254mm 250g
20mm 155mm 80g
Maximum hardness of test surface
940HV
940HV
1000H V
650HB
1200HV
Average surface roughness of test surface Ra:
1.6μm
1.6μm
0.4μm
6.3μm
1.6μm
Minimum weight of test piece: Can be directly measured Stable support required Dense coupling required
>5kg 2~5kg
0.05~2k g
>5kg 2~ 5kg
0.05~2 kg
>1.5kg
0.5~1.5 kg
0.02~0. 5kg
> 15kg 5~ 15kg
0.5~5kg
>5kg 2~5kg
0.05~2kg
Minimum thickness of test piece Dense coupling
Minimum depth of hardened case
5mm
0. 8mm
5mm ≥0.8mm
1mm
0.2mm
10mm ≥1.2mm
5mm ≥0.8mm
Ball joint indentation size
When the hardness is 300HV
Indentation diameter Indentation depth
0.54mm 24 μm
0.54mm 24 μm
0.38mm 12 μm
1.03mm 53μm
0.54mm 24μm
Hardness 600HV
Hour
Indentation diameter Indentation
0.54mm 17 μm
0.54mm 17 μm
0.32mm 8 μm
0.90mm 41 μm
0.54mm 17 μm
EN
8.3 Attached table 3
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
33
Page 42
Attached table
depth
When the hardness is 800HV
Indentation diameter Indentation depth
0.35mm 10μm
0.35mm 10μm
0.35mm 7 μm
--
--
0.35mm 10 μm
Applicable Scope of impact device
Type DC type for hole or cylinder; Type DL for slot or hole
Type D+15 for groove or concave surface
Type C for light and thin parts and hardene d surface.
Type G for heavy and rough castings and forgings
Type E for material with extremely high hardness
EN
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
34
Page 43
Attached table
Ser ial No
Code
model
Diagram of special­shaped support ring
remarks
1
03-03.7
Z10-15
Measure the external cylindrical surface R10~R15
2
03-03.8
Z14.5-30
Measure the external cylindrical surface R14. 5~R30
3
03-03.9
Z25-50
Measure the external cylindrical surface R25~R50
4
03-03.10
HZ11-13
Measure the internal cylindrical surface R11~R13
5
03-03.11
HZ12.5-17
Measure the internal cylindrical surface R12.5~R17
6
03-03.12
HZ16.5-30
Measure the internal cylindrical surface R16.5~R30
7
03-03.13
K10-15
Measure the external spherical surface SR10~SR15
8
03-03.14
K14.5-30
Measure the external spherical surface SR14.5~SR30
9
03-03.15
HK11-13
Measure the internal spherical surface SR11~SR13
10
03-03.16
HK12.5-17
Measure the internal spherical surface SR12.5~SR17
11
03-03.17
HK16.5-30
Measure the internal spherical surface SR16.5~SR30
12
03-03.18
UN Measure the external cylindrical surface, the radius is adjustable R10~∞
EN
8.4 Attached table 4
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
35
Page 44
Appendix
Order information
Order number
Host model
Leeb hardness tester
HT360
Leeb hardness tester Bluetooth version (+Bluetooth printer)
HT360C
Standard accessories
Power adapter
USB cable
D-type impact device
Nylon brush A
Small support ring
Product certificate
Instrument Kit
Matching
Standard Leeb hardness block
Toolbox
EN
9 Appendix
9.1 Appendix A: Accessories and Options
HT360 series user manual Copyright©Qingdao Hantek Electronics Co.,LTD
36
Page 45
Appendix
EN
9.2 Appendix B: Warranty Summary
Qingdao Hantek Electronics Co., Ltd. (hereinafter referred to as Hantek) promises that the mainframe and accessories of its production instruments will be free from any material and process defects within the product warranty period. During the warranty period, if the product is proved to be defective, Hantek will repair or replace it for free. For detailed warranty regulations, please refer to Hantek's official website or product warranty card. For the full text of the repair service or warranty instructions, please contact the Hantek repair center or local offices. Except for the warranty provided in this summary or other applicable warranty cards, Hantek does not provide any other express or implied warranty, including but not limited to any implied warranty on the product's tradability and applicability for special purposes. In no event shall Hantek be liable for indirect, special or consequential losses.
Copyright©Qingdao Hantek Electronics Co.,LTD HT360 series user manual
37
Page 46
Address: Building 35, Liandong U Gu, No. 780 Baoyuan Road, High tech Zone, Qingdao, Shandong Operator: 400-036-7077 Email: service@hantek.com Tel.: 0532-556787770, 55678772, 55678773 Postal code: 266000 Official website: www.hantek.com Qingdao Hantek Electronics Co., Ltd