Hantek HDP135V6A, HDP135V6S User guide

Page 1
HDP135V6 DC Power Supply User Manual
digits
HDP135V6
1
35.2V/6.2A
4
None
115/230VAC
HDP135V6A
1
35.2V/6.2A
4
None
230VAC
HDP135V6B
1
35.2V/6.2A
4
None
115VAC
HDP135V6S
1
35.2V/6.2A
4
Yes
115/230VAC
Voltage
Load Regulation
≤0.1% + 5mV
Line Regulation
≤0.01% + 5mV
Set Resolution
10mV
Set Accuracy
≤0.1% + 1 digits
Resolution
Readback Accuracy
≤0.1% + 1 digits
Ripple
10mVrms
Current
Load Regulation
≤0.2% + 3mA
Line Regulation
≤0.2% + 3mA
Set Resolution
1mA
Set Accuracy
≤0.2% + 3mA
Resolution
Readback Accuracy
≤0.2% + 3 digits
Ripple
5mArms
OVP
0 ~ 35.2V ± 0.2%FS
Maximum Voltage
35.2V ± 0.2%
OCP
0 ~ 6.2A ± 0.2%FS
Maximum Current
6.2A ± 0.2%
Quick Charge
Output Voltage Range
Output Power
Maximum: 18W
DCP (Apple, Samsung and BC1.2), Qualcomm QC2.0/QC3.0, Huawei Quick Charge Protocol FCP, Samsung Quick Charge Protocol AFC
General Features
No parity check
230 VAC ± 10%,
50/60Hz
Relative Humidity ≤ 80%
Relative Humidity ≤ 80%
Cooling
Air cooling
Weight
2.2 Kg
Size
85 * 150 * 230 (mm)
I. Product Introduction
HDP135V6 power supply is a high quality, cost-effectiveDC power supply. It has four-digit LED voltage and current display. It also has over voltage protection (OVP), over current protection (OCP), over temperature protection (O TP) an d USB quick charging functions.
5V ~ 12V
Supported Quick Charging Protocol
II. Product Model
Model CH Output V/A
LCD
RS232 AC input
III. PerformanceSpecifications
1 Rated Working Condition
AC input: 115 VAC ± 10%, 230 VAC ± 10%, 50/60Hz Working Conditions: Temperature -10~40
Relative humidity ≤80%
Storage Conditions: Temperature -20~60
Relative humidity ≤80%
2 Specifications
All technical specifications can only be guaranteed when the instrument is operat ed cont inuous ly for more than 30 minutes at the specified oper ating temper ature (18℃ to 28℃).
Remote Interface
AC Input
Working Conditions
Storage Conditions
IV.Front Panel
RS232 (Optional) Baud rate: 2400 Data bit: 8 Stop bit: 1
115 VAC ± 10%,
Temperature -10 to 40
Temperature -20 to 60
Readback
Readback
10mV
1mA
1 Voltage Display 2 Current Display 3 Save and Recall Keys M1 ~ M10
M1 ~ M4: Press [M*] once, and the indicator lights up to display the group settings.Use the voltag e and current adjustment knobs to adjust the settings that need to be saved, and then long press the [M*]key until the indicator lights up , the set tings will be save d in the [M*] position. M5 ~ M10: To use M5 ~ M10 to save and recall, use it in conjunction with the [Shift] key.TakingM5 as an example, press the [Shift]key and the [Shift]
1
Page 2
indicator will light up. Press the [M1]key below M5 once again and the [M1] indicator will light up to display the group settings of M5.Use the voltage and current adjustment knobsto adjust the settings that need to be saved. Press the [Shift]key and the
[Shift] indicator will light up. Then long press the [M1]key below M5 until the [M1] indicator lights up and the settings will be saved in the M5 position.
4 Shift Key
Some keys provide texts above them.This indicates that the key has a function that you can access by pressing and releasing the [Shift] key before pressing this key.For example, if you press and release [Shift] before pressing [M1], you will access
M5 function:
5 ON/OFF: Enables or disables output. 6 Output Terminal
Positive output terminal (red): Connect to the positive terminal of the load. Negative output terminal (black): Connect to the negative terminal of the load. Ground terminal (green): Connect to the chassis or ground cable (ground ter m inal of power cable).
7 USB Quick Charge Port
The output voltage of USB quick charge rang es fro m 5V to 12V, providing a maximum output power of 18 W. The USB quick charge automatically adjusts the output voltage and current accordi ng to the identified quick charge protocol. Typical output voltagesand currents are 5V@3.4A, 9V@2.0A, and 12V@1.5A. When charging an electronic device that does not have quick charging function, charging will be provided at standard 5V. USB quick charge provides input overvoltage and undervoltage protection, output overcurrent, overvoltage, undervoltage, short circuit protection and other functions. The quick charge indicator lights up when the quick charge request voltage is not 5V, that is, it lights up when the request voltage is high er or low er than 5V.
8 Keyboard Lock: Pr ess the key, the indicator will light
up, and except this key and [ON/OFF]key,all keys and knobs are disabled. Press the key again and all keys and knobs are restoredto use.
9 Current Adjustment Knob
Press down the knob to enter the setting mode with
the digit flashing.Press the knob several times in succession to change the flashing digit.Turn the knob clockwise to increase the value, and turn the knob counterclockwise t o decr ease the value.
10 OCP (Over Current Protection)
Press the [OCP]key to turn on the OCP function, and the indicator will be on. Press the [OCP]key again to turn off the OCP function, and the indicator will be off.Long press the [OCP]key to enter the setting mode and use the current adjustment knob to change the OCP setting value.When the actual output current is higher than the OCP setting value, the protection function is triggered, the screen displa ys " ", and the output is forcibly turned off. However, the [ON/OFF] indicator is not turned off, you can press the [ON/OFF]key to clear the error and turn off the indicator.
11 Voltage Adjustment Knob: The same as the
current adjustment knob.
12 OVP (Over Voltage Protection)
Press the [OVP]key to turn on the OVP function, and the indicator light will be on. Press the [OVP]key again to turn off the OVP function, and the indicator light will be off.Lo ng pres s the [OVP]key to ent er the setting mode and use the voltage adjustment knob to change the OVP setting value.When the actual output voltage is higher than theOVP setting value, the protection function is triggered, the screen displa ys " ", and the output is forcibly turned off, but the [ON/OFF] indicator is not turned off. Pr ess the [ON/OFF]key to clear the error and turn off the
indicator. 13 CC (Constant Current Output): In the constant current output state, the CC in di c at or l ight is on. 14 Keyboard Lock Sign: Press theKeyboard Lock
key, the light will be on.In keyboardlock mode,
except Keyboard Lock key and [ON/OFF] key, all
keys and knobs are disabled. Press Keyboard Loc k
key again and all keys and knobs are restored to
use. 15 CV (Constant Voltage Output): In the constant
voltage output state, t he CV indicator light is on.
V. Rear Panel
2
Page 3
VI. Safety Instructions
1 Check the AC Voltage Gear
The HDP135V6 power supply supports two specifications of AC powerinputs(115VAC or 230VAC).Before use, the user should check the gear of the AC voltage selector on the rear panel of the power supply, and the input voltage should be with in the range allowed by the gear (±10%).
2 Check the Fuse
The instrument has been installed with fuse of specified specification at delivery.Before use, please check whether the fuse model matches the AC voltage gear.If the fuse does not match or is blown, replace the fuse accordin g t o t he specification.
Procedure for replacing a f us e:
1. Turn off the power supply and remove the power cable.
2. Take out the fuse holder.
3. Remove the fuse and install a new one.
4. Take the fuse holder back into the slot.
3 Connect the AC Power Supply
Use the power cable provided in the accessories to connect the instrument to the properly grounded AC power supply. To avoid electric shock, please make sure that the instrument is properly grounded.
4 Startup
Press the power switch to start the instrument. The display screen will be lightened up.
VII. RS232 Remote Control
Only HDP135V6S supports RS 232 communication.
To use RS232 for remote control, please log in to the following website to downl oad:
http://hantek.com/products/detail/17189
Or scan the QR code below to ent er t he website:
VIII. Troubleshooting
1 If the AC power supply voltage is normal and the display screen does not light after th e startup, it may be a fuse blown or other faults.Turn off the instrument, disconnect the power cable, replace the fuse, or ask a professional for inspection and repair. 2 For constant voltage output, if the output voltage is less than the setting value and the CC light is on, which indicates that the instrument is in current protection. Itwill automatically switch to constant current output state. At this time, check the load or increase the maximum current accord ing to the use situation. 3 For constant current output, if the output current is less than the setting value and the CV light is on, which indicates that the instrument is in open circuit vo ltage protection. It will automatically switch to constant voltage output state. At this time, check the load or increase the maximum voltage according to the use situation. 4 If the fault persists, please contact Hantek.