read/write head TNSLR-Q350-H1147
Type code TNSLR-Q350-H1147
Ident no. 7030454
Mounting conditions non-flush Ambient temperature -25…+70 °C
Rectangular, 370x350 mm, height 20
mm
Active face on top
Plastic, PBT-GF30-VO
Powered and operated only via BL ident
interface module
Male M12 x 1, only for use with BL ident
extension cable
Connectors …/S2503
Connectors …/S2500
DC rated operational current Data transfer inductive coupling Operating frequency 13.56 MHz Radio communication and protocol standards ISO 15693 Read/write distance max. 794 mm Output function 4-wire, read/write
Construction rectangular, Q350 Dimensions 370x 350x 20mm Housing material plastic, PBT, black Material active area plastic, Black
Connection male, M12 x 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) IP Rating IP67 MTTF 121 years acc. to SN 29500 (Ed. 99) 40 °C Power-on indication LED green Diagnostic display Functional description of yellow range-restrict-
Edition • 2015-08-27T10:30:40+02:00
1 / 3 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com
ð 150 mA
ed LED: If the read/write head is supplied with voltage, it briefly checks to see whether its resonance frequency is affected by sur­rounding metal. If this is the case, the reso­nant circuit off-tunes its frequency to reach again the (optimum) resonance frequency. However, this is only possible within a cer­tain range. If too much metal is in the envi­ronment, the read/write head cannot re-tune or the surrounding metal takes too much en­ergy from the field and due to the reduced range the communication between the read/ write head and the data carrier is cut off (the orange range-restricted-LED lights up). If the LED is off, this does not mean conversely, that no reduction in range occurs. The lit LED is rather an indication of too much metal in the environment and a greatly reduced range (about 50% less).
Connectors …/S2501
Functional principle
The HF read/write heads operating at a fre­quency of 13.56 MHz form a transmission zone the size of which (0…500 mm) varies, depending on the combination of read/write head and data carrier.
The read/write distances mentioned here on­ly represent standard values measured under laboratory conditions.
The read/write distances of the data carriers for mounting in metal TW-R**-M(MF) were de­termined in metal.
Attainable distances may vary by up to 30 % due to component tolerances, mounting con­ditions, ambient conditions and material quali­ties (especially when mounted in metal)
Testing of the application under real operat­ing conditions is therefore essential, especial­ly with read/write on-the-fly!
read/write head TNSLR-Q350-H1147
Packaged quantity 1
Special features Very long ranges
Edition • 2015-08-27T10:30:40+02:00
2 / 3 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com