Hans Turck and KG TNQ80, TNLRQ80L800, TNLRQ80L400, TNQ14, TNM18 User Manual

...
Page 1
USER­MANUAL RFID SYSTEM
INSTALLATION OF THE
BL IDENT-
SYSTEM
S1583/ 01
Page 2
2
BL ident
Page 3
Safety Instructions!
Before beginning installation work
Disconnect the device from the power supplyEnsure against accidental restartVerify isolation from the supplyCover or close off neighbouring units that are live.The assembly instructions provided for the device are to be
complied with
Only suitably qualified personnel according to EN 50 110-1/-2
(VDE 0105 part 100) are authorised to carry out work on this device/system.
When conducting installation work ensure that you are free of
electrostatic charge before touching the device.
Connection and signal cabl es are to be installed so that any
inductive or capacitive interference does not impair the automation functi ons .
The installation of automation devices and their operating
elements is to be carried out in s uch a way as to prevent unintentional operation.
In order to prevent cable or wire breakage on the signal side
generating undefined states in the automation devices, appropriate safety measures are to be taken for the I/O coupling on the hardware and software side.
The functional earth (FE) must be connected to the protective
earth (PE) or the equipotential bonding. The system installer is responsible for establishing this connection.
Ensure a reliable isolation of the extra-low voltage for the 24 volt
supply. Only those power supply units that comply with IEC 60 364-4-41, i.e. HD 384.4.41 S2 (VDE 0100 part 410) are to be deployed.
Fluctuations or deviations of the mains voltage from the nominal
value should not exceed the tolerance limits specified in the technical data, otherwise malfunctions and dangerous states may occur.
D101583 0207 BL ident 3
Page 4
Devices for mounting in housings or cabinets, desktop or
portable units, are only to be operated and controlled with the housing closed.
Measures are to be taken to ensure the correct restarting of a
program following interruption due to a voltage drop or failure. Dangerous operating conditions, even short term, should not occur as a result. If required an emergency stop should be carried out.
External measures are to be implemented at those locations
where faults in the automation installation could lead to injury to persons or damage to property. These measures must guarantee safe operating conditio ns even in the event of a fault or malfunction (e.g. by means of independent limit switches or mechanical locking devices etc.).
The electrical installation must be carried out in accordance with
the relevant regulations (e.g. in respect of the cable cross sections, fuses and protective earth connections).
All work involving transport, installation, commissioning and
maintenance is to be carried out exclusively by qualified personnel (in accordance with IEC 60 364 i.e. HD 384 or DIN VDE 0100 and national acciden t prevention regulations).
USA Radio Frequency Interference FCC Part 15 Notice:
Changes or modifications not expressly approved by TURCK could void the user's authorit y to operate the equipment
D101583 0207 BL ident4
Page 5
Contents
Contents
About this manual
Documentation concept..............................................................................0 – 2
Description of symbols used ......................................................................0 – 4
Prescribed use ......................................................................................0 – 5
Notes concerning planning / Installation of this product......................0 – 5
1 The TURCK BL ident System – Overview
Schematic representation of the identification system BL ident ................1 – 2
Support for BL ident-projects ...............................................................1 – 2
Networking with BL ident systems........................................................1 – 3
Identification systems with radio frequency technology (RFID)..................1 – 4
Characteristics and fields of application of the BL identsystem.................1 – 5
Degree of protection .............................................................................1 – 5
Service life.............................................................................................1 – 5
Transmission frequency........................................................................1 – 5
Size........................................................................................................1 – 6
Read/write time.....................................................................................1 – 6
Compatibility .........................................................................................1 – 7
Areas of application (examples) ............................................................1 – 7
The BL ident-configurator .....................................................................1 – 8
2 TURCK BL iden t System – Planning
Selection criteria for data carriers and read-write head..............................2 – 2
Transfer zone and read-write distance.......................................................2 – 3
Length of the transfer zone and width offset..............................................2 – 4
Minimum distance of the data carriers to read-write head,
influence of adjacent fields .........................................................................2 – 4
Permissible direction of movement of the data carrier...............................2 – 4
Reading and writing in static operation ......................................................2 – 4
Reading and writing in dynamic operation (on the fly)................................2 – 5
Dwell time of the data carrier Td..................................................................2 – 5
Calculation of the maximum quantity of user data
in dynamic operation...................................................................................2 – 5
Minimum distances between two adjacent data carriers ...........................2 – 6
D101583 0207 BL ident
5
Page 6
Contents
3 Installation guidelines
Overview.....................................................................................................3 – 2
Reduction of metallic influences.................................................................3 – 2
Installation of several read-write heads on metal frames
or metal supports........................................................................................3 – 3
No mounting of the data carrier directly on metal......................................3 – 5
Conclusion – influence on the transfer from metal.....................................3 – 5
4 EMC directives
For whom are the EMC directives intended?............................................. 4 – 2
Dispersion of electromagnetic interference................................................4 – 2
How can RFID be subject to interference?...........................................4 – 3
Coupled interference.............................................................................4 – 3
What does EMC mean?..............................................................................4 – 4
Fundamentals for EMC protection..............................................................4 – 5
Installation in a switch cabinet ..............................................................4 – 6
Avoiding sources of interference ...........................................................4 – 7
Potential equalization............................................................................4 – 7
Shielding the cable................................................................................4 – 7
5 Description of the data carrier
Type overview.............................................................................................5 – 2
Function principle........................................................................................5 – 3
Technical data
TW-R16-B64...............................................................................................5 – 5
TW-R16-B128.............................................................................................7 – 7
TW-R20-B128.............................................................................................9 – 9
TW-R30-B128...........................................................................................5 – 11
TW-R50-B128...........................................................................................5 – 13
TW-R20-K2...............................................................................................5 – 15
TW-R30-K2...............................................................................................5 – 17
TW-R50-K2...............................................................................................5 – 19
TW-R22-HT-B64.......................................................................................5 – 21
6 D101583 0207 BL ident
Page 7
Contents
TW-R50-90-HT-B128................................................................................5 – 23
TW-R50-90-HT-K2................................................................................... 5 – 25
TW-I14-B128.............................................................................................5 – 27
TW-L43-43-F-B128...................................................................................5 – 29
TW-L82-49-P-B128 ..................................................................................5 – 31
6 Description of the read-write heads
Type overview.............................................................................................6 – 2
Function principle........................................................................................6 – 3
Technical data
TB-M18-H1147...........................................................................................6 – 6
TB-M18-H1147/S1126 (optimised for special data carriers)......................6 – 7
TB-EM18WD-H1147 (wash-down)..............................................................6 – 8
TB-EM18WD-H1147/S1126 (wash-down, optimised for special
data carriers) ..............................................................................................6 – 9
TN-M18-H1147.........................................................................................6 – 10
TN-M18-H1147/S1126 (optimised for special data carriers)....................6 – 11
TN-EM18WD-H1147 (wash-down)...........................................................6 – 12
TN-EM18WD-H1147/S1126 (wash-down, optimised for special
data carriers) ............................................................................................6 – 13
TB-M30-H1147.........................................................................................6 – 14
TB-M30-H1147/S1126 (optimised for special data carriers)....................6 – 15
TB-EM30WD-H1147 (wash-down)............................................................6 – 16
TB-EM30WD-H1147/S1126 (wash-down, optimised for special
data carriers) ............................................................................................6 – 17
TN-M30-H1147.........................................................................................6 – 18
TN-M30-H1147/S1126 (optimised for special data carriers)....................6 – 19
TN-EM30WD-H1147 (wash-down)...........................................................6 – 20
TN-EM30WD-H1147/S1126 (wash-down, optimised for special
data carriers) ............................................................................................6 – 21
TN-CK40-H1147.......................................................................................6 – 22
TN-CK40-H1147/S1126 (optimised for special data carriers)..................6 – 23
D101583 0207 BL ident
7
Page 8
Contents
TN-Q80-H1147 .........................................................................................6 – 24
TN-Q80-H1147/S1126 (optimised for special data carriers)....................6 – 25
TNER-Q80-H1147 (increased range)........................................................6 – 26
TNLR-Q80-H1147 (long range).................................................................6 – 27
TNLR-Q80-H1147/S1126 (long range, optimised for special
data carriers).............................................................................................6 – 28
TN-S32XL-H1147......................................................................................6 – 29
Connection of the read-write heads .........................................................6 – 30
7 Description of the read-write heads with corresponding data carriers
Notes for the operating data.......................................................................7 – 5
TB-M18-H1147............................................................................................7 – 3
TB-EM18WD-H1147....................................................................................7 – 3
TB-M18-H1147/S1126................................................................................7 – 4
TB-EM18WD-H1147/S1126 ........................................................................7 – 4
TN-M18-H1147............................................................................................7 – 5
TN-EM18WD-H1147....................................................................................7 – 5
TN-M18-H1147/S1126................................................................................7 – 6
TN-EM18WD-H1147/S1126........................................................................7 – 6
TB-M30-H1147............................................................................................7 – 7
TB-EM30WD-H1147....................................................................................7 – 8
TB-M30-H1147/S1126................................................................................7 – 9
TB-EM30WD-H1147/S1126 ......................................................................7 – 10
TN-M30-H1147..........................................................................................7 – 11
TN-EM30WD-H1147..................................................................................7 – 12
TN-M30-H1147/S1126..............................................................................7 – 13
TN-EM30WD-H1147/S1126......................................................................7 – 14
TN-CK40-H1147........................................................................................7 – 15
TN-CK40-H1147/S1126 ............................................................................7 – 16
TN-Q80-H1147..........................................................................................7 – 17
TN-Q80-H1147/S1126..............................................................................7 – 18
8 D101583 0207 BL ident
Page 9
Contents
TNER-Q80-H1147 .....................................................................................7 – 19
TNLR-Q80-H1147......................................................................................7 – 20
TNLR-Q80-H1147/S1126..........................................................................7 – 21
TN-S32XL-H1147......................................................................................7 – 22
8
Overtravel dista nces of the read-write head s with corresponding da t a carriers
Notes for the overtravel distances..............................................................8 – 3
Overtravel distance read-write head – housing style M18
TN-M18-H1147 with data carrier TW-R16-…B128 ....................................8 – 4
TB-M18-H1147 with data carrier TW-R16-…B128.....................................8 – 4
TN-M18-H1147 with data carrier TW-R20-…B128 ....................................8 – 5
TB-M18-H1147 with data carrier TW-R20-…B128.....................................8 – 5
TN-M18-H1147 with data carrier TW-R30-…B128 ....................................8 – 6
TB-M18-H1147 with data carrier TW-R30-…B128.....................................8 – 6
TN-M18-H1147 with data carrier TW-R50-…B128 ....................................8 – 7
TN-M18-H1147 with data carrier TW-R20-…K2 ........................................8 – 7
TB-M18-H1147 with data carrier TW-R20-…K2.........................................8 – 8
TN-M18-H1147 with data carrier TW-R30-…K2 ........................................8 – 8
TN-M18-H1147 with data carrier TW-R50-…K2 ........................................8 – 9
Overtravel distance read-write head – housing style M30
TN-M30-H1147 with data carrier TW-R16-…B128 ....................................8 – 9
TB-M30-H1147 with data carrier TW-R16-…B128...................................8 – 10
TN-M30-H1147 with data carrier TW-R20-…B128 ..................................8 – 10
TB-M30-H1147 with data carrier TW-R20-…B128...................................8 – 11
TN-M30-H1147 with data carrier TW-R30-…B128 ..................................8 – 11
TB-M30-H1147 with data carrier TW-R30-…B128...................................8 – 12
TN-M30-H1147 with data carrier TW-R50-…B128 ..................................8 – 12
TB-M30-H1147 with data carrier TW-R50-…B128...................................8 – 13
TN-M30-H1147 with data carrier TW-R20-…K2 ......................................8 – 13
TB-M30-H1147 with data carrier TW-R20-…K2.......................................8 – 14
TN-M30-H1147 with data carrier TW-R30-…K2 ......................................8 – 14
D101583 0207 BL ident
9
Page 10
Contents
TB-M30-H1147 with data carrier TW-R30-…K2.......................................8 – 15
TN-M30-H1147 with data carrier TW-R50-…K2 ......................................8 – 15
TB-M30-H1147 with data carrier TW-R50-…K2.......................................8 – 16
Overtravel distance read-write h ead – housing style Q40
TN-CK40-H1147 with data carrier TW-R16-…B128.................................8 – 16
TN-CK40-H1147 with data carrier TW-R20-…B128.................................8 – 17
TN-CK40-H1147 with data carrier TW-R30-…B128.................................8 – 17
TN-CK40-H1147 with data carrier TW-R50-…B128.................................8 – 18
TN-CK40-H1147 with data carrier TW-R20-…K2.....................................8 – 18
TN-CK40-H1147 with data carrier TW-R30-…K2.....................................8 – 19
TN-CK40-H1147 with data carrier TW-R50-…K2.....................................8 – 19
Overtravel distance read-write h ead – housing style Q80
TN-Q80-H1147 with data carrier TW-R16-…B128...................................8 – 20
TN-Q80-H1147 with data carrier TW-R20-…B128...................................8 – 20
TN-Q80-H1147 with data carrier TW-R30-…B128...................................8 – 21
TN-Q80-H1147 with data carrier TW-R50-…B128...................................8 – 21
TN-Q80-H1147 with data carrier TW-R20-…K2.......................................8 – 22
TN-Q80-H1147 with data carrier TW-R30-…K2.......................................8 – 22
TN-Q80-H1147 with data carrier TW-R50-…K2.......................................8 – 23
Overtravel distance read-write head – housing style S32
TN-S32XL-H1147 with data carrier TW-R16-…B128...............................8 – 23
TN-S32XL-H1147 with data carrier TW-R30-…B128...............................8 – 24
TN-S32XL-H1147 with data carrier TW-R50-…B128...............................8 – 24
TN-S32XL-H1147 with data carrier TW-R30-…K2...................................8 – 25
TN-S32XL-H1147 with data carrier TW-R50-…K2...................................8 – 25
9 Accessories
General description of the accessories.......................................................9 – 2
Accessories for Ø 30 mm and Ø 50 mm data carriers
Spacer DS-R30...........................................................................................9 – 3
Spacer DS-R50...........................................................................................9 – 4
10 D101583 0207 BL ident
Page 11
Contents
Accessories for read-write heads of housing style M18
Mounting clip BS18.....................................................................................9 – 5
Mounting clip BSN18..................................................................................9 – 6
Mounting clip with limit stop BST-18B.......................................................9 – 7
Mounting clip without limit stop BST-18N..................................................9 – 8
Quick mounting mounts QM-18.................................................................9 – 9
Cover cap SKN/M18.................................................................................9 – 10
Accessories for cylindrical read-write heads of housing style M30
Mounting clip with limit stop BST-30B.....................................................9 – 11
Mounting clip without limit stop BST-30N................................................9 – 12
Quick mounting mounts QM-30...............................................................9 – 13
Cover cap SKN/M30.................................................................................9 – 14
Common accessories for read-write heads of housing style M18 and M30
Mounting aid for BST mounting clips BST-UH.........................................9 – 15
Mounting aid for BST mounting clips BST-UV .........................................9 – 16
Inscription labels for BST mounting clips BST-BS...................................9 – 17
Accessories for read-write heads of housing style CK40
Protective mounting MF-CK40-1S............................................................9 – 18
Protective mounting MF-CK40-2S............................................................9 – 19
Protective mounting MF-CK40-3S............................................................9 – 20
Protective housing SG40..........................................................................9 – 21
Protective housing SG40/2, temperature resistant...................................9 – 22
Adjustable rail JS 025/037........................................................................9 – 23
Cover cap T-CK40-T-FC...........................................................................9 – 24
Cover capT-CK40-D-FC, temperature resistant.......................................9 – 25
Handheld with accessories
PD-ident....................................................................................................9 – 26
PD-ident-WLAN........................................................................................9 – 27
PD-ident-PF..............................................................................................9 – 27
PD-ident-DS..............................................................................................9 – 27
D101583 0207 BL ident
11
Page 12
Contents
PD-ident-RB..............................................................................................9 – 28
PD-ident-BC..............................................................................................9 – 28
PD-ident-RS..............................................................................................9 – 28
PD-ident-CB..............................................................................................9 – 28
12 D101583 0207 BL ident
Page 13
About this manual
About this manual
Documentation concept....................................................................................2
Description of symbols used ............................................................................4
Prescribed use ........................................................................................... 5
Notes concerning planning / Installation of this product ........................... 5
D101583 0207 BL ident
0 – 1
Page 14
About this manual
Documentation concept
This manual contains all the information necessary for professional installation of the BL ident systems particularly with regard to the data carriers and the read-write heads.
The following chapter provides an overview of the BL ident system, how to plan a BL ident system and indicates the necessary installation guidelines while providing a brief overview of the EMC directives. The manual also describes the functional principle of the data carriers and read-write heads, the technical data and operating data as well as the available accessories.
The manuals for BL67 and BL20 I/O modules contain information concerning the non bus-specific I/O modules of the modular TURCK BL67 and BL20 systems. You can find a short system description, a detailed function description of the I/O modules as well as all the information concerning topics such as mounting/dismounting and inscription. The manuals contain a short description of the I/O­ASSISTANT which is the engineering and configuration software for TURCK I/O products.
Manual BL67 I/O Modules
TURCK documentation number: German D300572/ English D300529
Manual BL20 I/O Modules
TURCK documentation number: German D300716/ English D300717
Also included are manuals concerning the PROFIBUS-DP and DeviceNet™ gateway of the BL67 and BL20 series. These include a short BL67 or BL20 system description and a description of the PROFIBUS-DP or DeviceNet™ fieldbus systems. Besides you will find exact details concerning the function and design of bus-specific gateways as well as all bus-specific information concerning the connection to different automation devices, the maximum system extension, etc.
Manual BL67 PROFIBUS-DP
TURCK documentation number: German D300570/ English D300527
0 – 2 D101583 0207 BL ident
Page 15
About this manual
Manual BL67 DeviceNet™
TURCK documentation number: English D300528
Manual BL20 PROFIBUS-DP
TURCK documentation number: German D300822/ English D300458
Manual BL20 DeviceNet™
TURCK documentation number: English D300460.
Further support can be found in the following manuals for engineering, installation and commissioning:
Manual D101580 - This manual describes the professional
application of BL ident interface modules.
Manual D101578 - This manual includes instructions for
commissioning of a BL ident systems using the function block “Proxy Ident Function Block”. The commissioning example is undertaken using a SIMATIC S7/-300 station (Siemens). SIMATIC STEP 7 standard software is used.
Manual D101606 - This manual contains the software
description for the so-called “Handheld” (programming device) which can be used to read data irrespective of the location.
Manual D101584 - This manual contains the hardware
description for the so-called “Handheld” (programming device) which can be used to read data irrespective of the location.
D101583 0207 BL ident
0 – 3
Page 16
About this manual
Description of symbols used
Warning
This sign can be found next to all notes that indicate a source of hazards. This can refer to danger to personnel or damage to the system (hardware and software).
This sign means for the operator: work with extreme caution.
Attention
This sign can be found next to all notes that indicate a source of potential hazards.
This can refer to possible danger to personnel or damage to the systems (hardware and software) and installations.
Note
This sign can be found next to all general notes that supply important information about one or more operating stages.
These specific notes are intended to make operation easier and avoid unnecessary work due to incorrect operation.
0 – 4 D101583 0207 BL ident
Page 17
About this manual
Attention
Please read this section carefully. Safety aspects cannot be left to chance when dealing with electrical equipment
This manual contains all the necessary information concerning the intended usage of TURCK products. It has been specially developed for qualified personnel who have the required level of expertise.
Prescribed use
Warning
The devices described in this manual must be used only in applications prescribed in this manual or in the respective technical descriptions, and only in connection with components and devices from third party manufacturers that have been certified.
Appropriate transport, storage deployment and mounting as well as careful operating and thorough maintenance guarantee trouble-free and safe operation of these devices.
Notes concerning planning / Installation of this product
Warning
It is imperative that all respective safety measures and accident protection guidelines be adhered to.
D101583 0207 BL ident
0 – 5
Page 18
About this manual
0 – 6 D101583 0207 BL ident
Page 19
The TURCK BL ident System
1 The TURCK BL ident system
Schematic representation of the identification system BL ident .........................2
Support for BL ident projects......................................................................2
Networking with BL ident systems..............................................................3
Identification systems with radio frequency technology (RFID)........................4
Characteristics and fields of application of the BL ident system......................5
Degree of protection ...................................................................................5
Service life ...................................................................................................5
Transmission frequency ..............................................................................5
Size..............................................................................................................6
Read/write time ...........................................................................................6
Compatibility ...............................................................................................7
Areas of application (examples): .................................................................7
The BL ident configurator .................................................................................8
1
D101583 0207 BL ident 1 – 1
Page 20
The TURCK BL ident System
PLC/PC for commissioning
Interface module for integration in the fieldbus systems
Read/write devices
Mobile data carriers
IP20
IP67
Schematic representation of the identification system BL ident
The TURCK BL ident system consists of several levels. Every level offers variation options. An application adapted to the overall system is possible.
Figure: 1 System overview
Support for BL ident projects
Further support can be found in the following software for engineering, installation and commissioning:
For simulation and optimisation of an application a “BL ident
configurator” is available free of charge on the internet at www. turck.com (see page 1 - 8).
D101583 0207 BL ident1 – 2
Page 21
The TURCK BL ident System
Networking with BL ident systems
As it is possible to integrate BL ident systems in (existing) bus systems, networking of several BL ident systems is possible.
The guidelines which relate to the maximum extension of the respective bus systems apply.
A PROFIBUS system can only extend, for example, up to a maximum of 31 stations with 1 master when a repeater is not used.
1
D101583 0207 BL ident 1 – 3
Page 22
The TURCK BL ident System
Identification systems with radio frequency technology (RFID)
RFID is the abbreviation for Radio Frequency Identification.
An RFID system consists of a data carrier, a device for reading the data from the data carrier (read-write head) as well as other devices which perform the transfer and processing of data (interfaces).
The transfer of data from the data carrier to the read-write heads is undertaken using electromagnetic waves. This type of data transfer is non-contact, without a visual contact and is insensitive to dirt and temperature fluctuations.
The data carriers can be attached directly to a product. Further terms used for the data carriers are TAGs or transponders. The data content can consist of production and manufacturing data. Important it that this data identifies the product. This is the origination of the term “Identification System”.
A whole range of possibilities exist as the data content can be changed by writing on the data carrier. Accordingly, the production and manufacturing processes can be traced and monitored. Logistics/distribution can be optimized.
The “Identifications Systems” can be integrated into (existing) fieldbus systems (e.g. PROFIBUS). The integration of the respective fieldbus system is undertaken with suitable interfaces.
Standardized software modules (e.g. the Proxy Ident Function Block for PROFIBUS) enable simple system integration and commissioning with different controls.
D101583 0207 BL ident1 – 4
Page 23
The TURCK BL ident System
Characteristics and fields of application of the BL ident system
In order to comply with the demands presented by different fields of application, TURCK offers the BL ident system with a whole range of combination possibilities of data carriers and read-write heads as well as interfaces for integration into fieldbus systems (e.g. PROFIBUS-DP). Software modules enable simple integration and commissioning.
The characteristics of the TURCK BL ident system are listed in the following:
Degree of protection
All data carriers as well as the suitable write-read heads feature a high mechanical degree of protection (e.g. IP67) and can thus be subject to the most harsh industrial conditions.
The integration into a fieldbus system is implemented with suitable TURCK interface modules. The interface modules are available in degrees of protection IP20 and IP67. TURCK connection cables featuring an adequate degree of protection round off the identification system.
Service life
The service life results from the possible number or read-write operations on the data memory.
FRAM memory features an unlimited number of read operations
10
and 10
write operations.
EEPROM memory features an unlimited number of read operations and 105 write operations.
The data carrier does not require batteries.
1
Transmission frequency
The TURCK BL ident system operates with 13.56 MHz transmission frequency between the data memories and the read/write devices. Systems which operate with these transmission frequencies are practically immune to electromagnetic interference. The 13.56 MHz transmission frequency has developed into a standard in many RFID fields of application.
D101583 0207 BL ident 1 – 5
Page 24
The TURCK BL ident System
Size
TURCK supplies the data carriers with diameters of 16, 20, 30 and 50 mm.
The read-write units are available in different housing styles ranging from cylindrical M18 and M30, to rectangular CK40 and Q80 and ring-shaped S32XL.
Memory capacity
The memory capacity on the data storage device is 64 Bytes or 128 Bytes with an EEPROM memory and 2KBytes with an FRAM
memory. New data carriers are in the design stage.
FRAM: (Ferroelectric Random Access Memory), non-volatile, high service life based on the higher number of write-read operations
10
up to 1011)
(10
EEPROM: (Electrically Erasable Programmable Read Only Memory), non-volatile
Write time/read time (air interface only)
The write and read times depend for all data carriers on the number of bytes which are to be transferred. On FRAM data carriers the read and write time are almost identical and are between 0.7 and 3.4 ms/ byte. On EEPROM data carriers the read time is between 0.7 and 6 ms/byte and the write time is between 3.3 and 7.9 ms/byte.
The write-read distances depend on the corresponding combination of data carrier and read-write head, and can be between 0 and 200 mm. With the BL ident configurator the application variables speed, range and data quantity can be varied and the optimum combination can be selected for the respective application. The configurator is available online at http://www.turck.com/ (also see page 1 - 8).
D101583 0207 BL ident1 – 6
Page 25
The TURCK BL ident System
Compatibility
All technical data relates to the BL ident system, i.e. to the combinations of BL ident data carriers, read-write heads and interface modules. Completely different values may apply for data carriers from other manufacturers. Therefore they may only be used after prior approval by TURCK.
Areas of application (examples):
The characteristics as stated beforehand allow the application of a TURCK BL ident system in the following fields:
Automotive
Transport and handling
Machine (mechanical) engineering
Food and beverages
Chemicals
Pharmaceuticals and petrochemicals.
Possible areas of application are:
Assembly lines
Conveyors
Industrial manufacturing
Warehousing
Logistics
Distribution
Component picking
Transport logistics
1
D101583 0207 BL ident 1 – 7
Page 26
The TURCK BL ident System
The BL ident configurator
The use of sensors and actuators – and even fieldbusses – is state­of-the-art in many industrial fields. When RFID systems are used on the other hand, there are always questions relating to the air­interface, e.g. "How fast and at which distance can I move the data carrier past the write-read heads?". That is to say that there is a certain amount of general uncertainty concerning the range of applications of an RFID system.
General details such as "recommended write-read distance" or "transmission speed = 0.5 ms/ byte" are usually not sufficient for evaluation of the usage of the devices in a determined application, as the application variables such as data quantity, speed and distance are the result of a complex interaction between the read­write heads and data carriers.
With the “BL ident configurator” the respective application can be simulated and the correct preliminary selection can be made.
The setting of applications parameters by "playing" with the values allows the user to easily test the options and limits associated with the respective combinations.
D101583 0207 BL ident1 – 8
Page 27
The TURCK BL ident System
Figure: 2 BL ident configurator
1
The online variants of the configurator (available free on the Internet at www.turck.com) accesses the data in the TURCK product database and always provides the most up-to-date information.. In addition to simulating the application, the configurator also generates the corresponding data sheets and documentation.
D101583 0207 BL ident 1 – 9
Page 28
The TURCK BL ident System
D101583 0207 BL ident1 – 10
Page 29
BL ident System – Planning
2 TURCK-BL ident System – Planning
Selection criteria for data carriers, read-write head and interface module.......2
Transfer zone and read-write distance .............................................................3
Length of the transfer zone and width offset....................................................4
Minimum distance of the data carriers to read-write head,
fields..................................................................................................................4
Permissible direction of movement and alignment of the data carrier.............4
Reading and writing in static operation ............................................................4
Reading and writing in dynamic operation (on the fly)......................................5
Dwell time of the data carrier Td.......................................................................5
Calculation of the maximum quantity of user data in dynamic operation ........5
Minimum distances between two adjacent data carriers.................................6
influence of adjacent
2
D101583 0207 BL ident
2 – 1
Page 30
BL ident System – Planning
Selection criteria for data carriers, read-write head and interface module
The applicatio n should be jud ged using the f ollowing criteria in order to make the correct selection of BL ident system components:
Mechanical dimensionsDistance from data carriers to read-write heads when reading
and writing
Tolerances in the mechanic al guidanceStatic and/or dynamic transfer of dataData quantities to be transferredSpeed with dynamic writing and reading (on the fly)Metal-free areas with data carriers and read-write headsAmbient conditions such as humidity, temperature, chemical
influences, etc.
There are special selection criteria relating to read-write heads:
Mechanical dimensionsRequired transfer zoneSize of the data carrier in use
The following criteria should be considered specially for the use of the interface modules:
Degree of protectionBus typeNumber of channels
2 – 2 D101583 0207 BL ident
Page 31
BL ident System – Planning
S
r
H
L
sr
Transfer zone and read-write distance
Figure 1 Transfer zone
The read-write head generates an alternating inductive field. The recommended read-write distance resul ts from the combination of data carrier and read-write head. The appearance of the distribution of this field depends on the design of the antenna in the data carrier and in the read-write head.
Exchange of data is only possible within the transfer zone (Fig. 1) with the parameters L
= length of the transfer zone and Sr =
sr
recommended write-read distance. The transfer zone reduces when the distance from the data carrier to the read-write head increases and is reduced to a point at the threshold distance H, i.e. as the distance increases less data can be transferred or the speed at which the read-write head moves past the data carrier must be reduced.
2
Note
Using the BL ident configurator at www.turck.com allows the relationships to be simulated.
D101583 0207 BL ident
2 – 3
Page 32
BL ident System – Planning
Length of the transfer zone LSr and width offset
The length of the transfer zone LSr (Fig. 1) is dependent on the combination of data carrier and read-write head.
The width is particularly important for the tolerance of mechanical tracking.
Note
An illustrative representation of this relationship can be found in the BL ident configurator at www.turck.com.
Minimum distance of the data carriers to read-write head, influence of adjacent fields
Adjacent fields are practically always available. Normally th e adjacent fields should not be used for transfer of data, so there must be an minimum distance between data carriers and read-write head. But with the TURCK BL ident system a minimum distance must not be observed.
Permissible direction of movement and alignment of the data carrier
The data carrier can pass over the read-writ e head from any direction.
The data carriers can have any horizontal alignment. They should only be aligned in parall el to the read-write head.
Reading and writing in static operation
In static operation a data exchange is possible up to the range of the threshold distance H. The data carrier must be positioned exactly above the read-write head.
Reading and writing in dynamic operation (on the fly)
In dynamic operation the da ta carriers move past the read-write head. A data exchange is only pos sible within the transfer zone.
2 – 4 D101583 0207 BL ident
Page 33
BL ident System – Planning
Dwell time of the data carrier T
The dwell time Td is the time in wh ich the data carrier is present in the transfer zone of the read-write head as it passes by. The read­write head exchanges data with the data carrier during this time.
The dwell time Td is calculated as follows: Td = LSr / V
Tag
where: LSr:length of the transfer zone
V
:speed of the data carrier in dynamic operation
Tag
In static mode the dwell time can be as long as necessary. The dwell time must be long enough to ensure that communication with the data carrier has been completed.
In dynamic operation the dwell time is defined by the system environment. The dwell time must be matched to the data quantity to be transferred. Conversely, this means that the shorter the dwell time, the lower the quantity of data to be transferred.
Note
At www.turck.com various examples relating to this topic can be examined with the BL ident configurator.
d
2
Calculation of the maximum quantity of user data in dynamic operation
The calculation of the maximum user data quantity is dependent on the read-write head used and the corresponding data carrier.
Example: Read-write head: TB-M18-H1147, Data carrier: TW-R30-K2 Pass speed: 0.5 m/s
D101583 0207 BL ident
2 – 5
Page 34
BL ident System – Planning
The read-write head contacts the data carrier when it is entering
the transfer zone: This takes about 2.7 ms.
With the second contact to the data carrier the read-write head
recognizes the data carrier. A signal is sent to the interface module: Duration about 12 ms.
The interface module sends a read-write command, e.g. read 4
bytes, incl. version and feedback of the data on the interface
module: Duration about 7 ms. This results in total to about 22 ms. Until 4 bytes of data have been processed by the interface module
takes about 5 ms/byte. This means when the data carrier passes the read-write head, a
max. of 8 bytes can be read or written.
Note
With the BL ident configurator at www.turck.c om different operating states in dynamic operation can be simulated and represented.
Minimum distances between two adjacent data carriers
The minimum distance between two data carriers is dependent on the size of the data carrier and the read-write head.
In dynamic operation (on th e fly) the minimum distance is stil l dependent on the data quantity and the bus c ycle time.
Note
Corresponding tests for determination of the minimum distance should be undertaken before commissioning.
2 – 6 D101583 0207 BL ident
Page 35
Installation guidelines
3 Installation guidelines
Overview...........................................................................................................2
Reduction of metallic influences.......................................................................2
Installation of several read-write heads on metal frames
or metal supports.............................. ...... ..... ...... ..... ..........................................3
No mounting of the data carrier directly on metal............................................6
Conclusion – influence on the transfer from metal...........................................7
3
D101583 0207 BL ident
3 – 1
Page 36
Installation guidelines
metal core
data carrier
read/write head
non-metallic spacer
plate
Overview
Because of the inductive operating principle of the data carriers and read-write heads, every type of metal (particularly iron and ferromagnetic materials) should be avoided in proximity of these devices, as they will influence the manner in which they fu nction.
It is necessary to observe the following important poi nts during engineering and installation:
Minimum distance between read-write headsMinimum distance between two adjacent data carriers (see
chapter 2, page 2 - 6)
Metal-free areas with instal lation of read-write heads and data
carriers on metals
Installation of several read-write heads on metal frames or
metal supports.
Reduction of metallic influences
Problem: A metal support is located above the transfer zone of the read-write head. This influences the entire field. Specifically, the transfer zone between read-write head and data carrier is reduced (Fig. 1).
Figure 1 Interfering metal supports.
3 – 2 D101583 0207 BL ident
Page 37
Installation guidelines
metal core
data carrier
read/write head
plate
non-metallic spacer
Remedy: Install the data carriers in a different manner and there will no longer by an influence on the transfer zone (Fig. 2).
Figure 2 Other arrangement of the data carrier
Installation of several read-write heads on metal frames or metal supports
Every read-write head which is mounted on metal couples a part of the field to the metal support . If the minimum distance d and the metal-free zones are observed, there is generally no mutual influence. If however a metal frame should have an unfavourable form an influen ce is s till po ssible . This re sults in lo nger da ta trans fer times and error messages in the interface module.
Problem: Mutual interference of the read-write heads
3
D101583 0207 BL ident
3 – 3
Page 38
Installation guidelines
d
read/write head
additional strunck
Remedy 1: Extend the distance d between both read-write heads (Fig. 3).
Figure 3 Extending the distance
Remedy 2: Fit one or several iron struts which should short-circuit the parasitic fie lds (Fig . 4) .
Figure 4 Fitting iron struts
3 – 4 D101583 0207 BL ident
Page 39
Installation guidelines
non-metallic spacer
Remedy 3: Place a non-metallic intermediary element of 20 to 40 mm thickness between the read-write head and the iron frame. This will significantly reduce the parasitic coupling of the field and the support (Fig. 5).
Figure 5 Addition of a n intermediary non­metallic element
Remedy 4: It is also possible to contact the read-write heads via the function block (PLC) and to use it to switch them on and off. The influence through another read -write head can be avoide d using the selective mode, where the channel in whose transfer window the data is located is active (see manual BL ident Proxy-Ident-Block (PIB), D101578). Using this met hod the adjacent read-write heads do not emit a field and there is no mutu al interference.
3
D101583 0207 BL ident
3 – 5
Page 40
Installation guidelines
h
metal
non-metallic spacer
data carrier
a
No mounting of the data carrier directly on metal
The data carriers (with the exception of h igh temperature data carriers) may not be mounted directly on metal. Non-metallic spacers (see chapter 9, Accessories) enable mounting which does not lead to an interruption of the functions (Fig. 6).
Figure 6 Installat ion with spacers
The data carriers may not be mounted so that the necessary minimum distance to metal and to the data carriers around them is less than the minimum distance. The minimum distance is dependent on the housing de sign of the read-write he ad; a = 10 mm around the data carrier can be assumed (Fig. 7). The high temperature data carrier (see page 5 - 2, table 1) can be constructed so that it can be mounted directly on metal without the need for additional measures.
Figure 7 Installation considering the minimum distance from metal
3 – 6 D101583 0207 BL ident
Page 41
Installation guidelines
Conclusion – influence on the transfer from metal
The following points should be considered with the installation of the BL ident components:
Data carriers (except high temperature data carriers) can not be
mounted directly on metal or suitable accessories must be used
(spacers)
It is important to ensure that no metallic rails (or similar parts)
intersect the transfer zone. The metal rails woul d interfere with
the field data.
Only plastic or stainless steel screws can be used for attachment
of the read-write heads.
3
D101583 0207 BL ident
3 – 7
Page 42
Installation guidelines
3 – 8 D101583 0207 BL ident
Page 43
EMC Directives
4 EMC directives
For whom are the EMC directives intended?................................................... 2
Dispersion of electromagnetic interference ......................................................2
How can RFID be subject to interference? .................................................3
Coupled interference...................................................................................3
What does EMC mean?....................................................................................4
Fundamentals for EMC protection....................................................................5
Installation in a switch cabinet ....................................................................6
Avoiding sources of interference.................................................................7
Potential equalization ..................................................................................7
Shielding the cable......................................................................................7
4
D101583 0207 BL ident
4 – 1
Page 44
EMC Directives
source of interference
e.g. motor
susceptible equipment
e.g. read/write head
link
e.g. cable connector
For whom are the EMC directives intended?
These EMC directives are intended for:
Project engineers and planners who are planning the system
with the RFID modules to be configured.
Installation personnel, service technicians and engineers, who
use this description to correctly lay the connection cables
have to remedy the existing problems during a malfunction.
In this chapter you will learn more about the EMC guidelines, particularly:
Dispersion of electromagnetic interference
What does EMC mean?
Fundamentals for EMC protection
Installation in a switch cabinet
Avoiding sources of interference
Potential equalisation
Shielding the cable
or
Dispersion of electromagnetic interference
Figure 1 Interference components
4 – 2 D101583 0207 BL ident
In a system or installation electromagnetic interference can only occur if the following components are mutually present:
Source of interference
Interference path
Susceptible equipment.
If one of these components is not present (for example the interference path), no interference will occur even if the source of interference sends high levels of interference (Fig. 1):
Page 45
EMC Directives
The measures for prevention of the interference (EMC) are relevant for all three components. The manufacturer is obliged to undertake all possible measures to counter the development of sources of interference.
The installation design must be implemented to ensure that mutual interference of the individual components is avoided or kept to as low a level as possible.
How can RFID be subject to interference?
Problem: interference radiation from the power supply when
switching mode power supplies are used.
Remedy: use of a stabilized power supply
Problem: interference via the serial connection cable.
Remedy: improved cable shielding and/or read-write head
earthing
HF interference via the antenna from another read-write head or
via an external source of interference which operates using the
same frequency.
Remedy: the interference from another read-write head can be
avoided by using the selective mode (see manual
BL ident Proxy-Ident-Block (PIB), D101578).
4
Coupled interference
There are four possibilities for coupled interference:
Galvanic coupled interference
Capacitive coupled interference
Inductive coupled interference
Radiated interference
There are different causes for the radiated interference on the data interface paths:
With cables and wiring:
Incorrect or poorly laid
Missing or incorrectly connected shield
Unfavourable arrangement of the cable
D101583 0207 BL ident
4 – 3
Page 46
EMC Directives
With the switch cabinet or housing:
Missing or incorrectly wired potential equalization wiring
Missing or incorrect earthing
Unfavourable arrangement
Modules which are not mounted in a fixed position
Unfavourable switch cabinet design.
What does EMC mean?
The increasing component density, increased switching speed of power electronics and the continuous rise in switching speeds present more and more sources of interference to electronic elements of a system. The following generally applies: the higher the level of automation, the higher the danger of mutual interference.
Definition of EMC:
“Electromagnetic compatibility (EMC) is the capability of an electrical or electronic device in an electromagnetic environment to function without fault, without influencing or interfering with the environment beyond defined limits.”
The TURCK BL ident devices are subjected to test compliance to the following standards:
EN 61000-4-2 (ESD)
EN 61000-4-3 (Electromagnetic fields)
EN 61000-4-4 (Burst)
EN 61000-4-5 (Surge)
EN 61000-4-6 (immunity to conducted disturbances induced by
radio-frequency fields)
As the RFID modules are only components of an overall system and sources of interferences can result from the combination of different components, the design of a system or installation must be subject to certain guidelines.
In order to obtain an installation which is immune to interference, a whole package of measures must be implemented; where the operator of the system or installation is responsible for the RFI suppression. They must observe and comply with the local and national stipulations and directives. All measures, which have been
4 – 4 D101583 0207 BL ident
Page 47
EMC Directives
undertaken during system design save expensive modifications and elimination of interference at a later date.
Fundamentals for EMC protection
The following elementary rules relating to electromagnetic compatibility (EMC) must be observed:
Shielding by a housing
Protect the device from external sources of interference by the
installation in a switch cabinet or housing. The cabinet or the
housing must be included in the connection to earth.
Shield the electromagnetic fields from inductances by partition
panels of devices. Use shielded data transmission cables with
metallic connector housings.
Large area ground connections
Connect all inductive metal parts over a large area and use a low
resistance for radio frequencies. Establish a large area
connection between the inactive metal parts and the central
earthing point.
Integrate the shield earth into the earthing concept, i.e. the end
of the shield must be connected to a large area to earth.
Planning of the cable routes
Divide the cables into power groups and lay them separately.
Lay the high power cables and the data cables in separate ducts
or bundles.
Introduce the entire cabling into the cabinet only from one side
and on a single level when possible.
Lay the data cables as close to earthed surfaces as possible.
Twist the incoming and outgoing cables of individually laid
conductor pairs.
In many cases an independent cable guidance for the bus cable
is already provided. Ideally this should also be used for laying the
data cables between read-write heads and interface modules.
Shielding of cables
Shield the data transfer cables and apply the shield on gateway
side. Shield the analogue cables and apply the shield at one end,
e.g. on the drive unit.
Always apply the cable shields at the entry to the switch cabinet
to a large area on the grounding bar and attach them with fixing
clamps.
4
D101583 0207 BL ident
4 – 5
Page 48
EMC Directives
Connect the applied shield to the module without interruption.
Use a braided shield and not a metal foil shield.
Mains and signal filter
Use the mains filter with metal housing.
Connect the filter housing on a wide area and with a low radio
frequency resistance to the switch cabinet earth.
Never attach the filter housing to painted surfaces.
Attach the filter at the switch cabinet entry or in the direction of
the interference source.
Installation in a switch cabinet
Metal housings shield susceptible equipment against magnetic and electrical fields as well as electromagnetic waves. The better that the induced interference current can flow, the better that the interference field will weaken itself. It is therefore essential to ensure that all housing panels are connected electrically conducting to each other.
If the switch cabinet panels are insulated from one another, an RF conductive connection using metal braiding and RF clips or RF paste (the greater the surface area of the connection the better) must be possible.
Interference can be avoided by optimum switch cabinet design. The following generally applies:
The effects of the interference generally reduce as the distance
between the susceptible equipment and the source of
interference increases.
An additional reduction in interference can be achieved by
installation of shield panels
Signal cables should keep a minimum distance of at least 10 cm
from high power cables.
External interference induced through the mains is avoided by the installation of mains filters. Ensure that the mains filter is correctly rated and fitted directly at the entry to the switch cabinet.
4 – 6 D101583 0207 BL ident
Page 49
EMC Directives
Avoiding sources of interference
Avoid the installation of sources of interference which occur primarily due to switched inductances.
Interference is generated primarily by relays, contactors, fluorescent lamps in the switch cabinet and valves, and can be avoided by the use of RC combinations, freewheel diodes etc. This also avoids inductive interference in the cables which are laid parallel to the coil cables.
Potential equalisation
If the system sections are subject to a different design and different voltage levels result, potential differences can result between the different sections of the system. Equalization currents then flow via signal cables (potential equalization should not be confused with a protective earth).
Therefore correctly implemented potential equalization is essential. The following points should be observed:
The potential equalization cable must have a sufficient cross-
section (min. 10 mm
2
).
The distance between signal cables and the respective potential
equalization cable must be as small as possible.
A stranded conductor must be used.
If the potential equalization cables are connected to the central
potential equalization bars, the power components and the non-
power components must be combined.
4
Shielding the cable
Signal cables must be shielded in order to avoid coupled interference. Even though the best shielding effect when laying the cables is achieved by using steel ducts, the use of cables with braided shields is usually sufficient. Decisive for the effect of the shield in both cases is however the correct connection, as a non­connected or incorrectly connected shield has no effect.
D101583 0207 BL ident
4 – 7
Page 50
EMC Directives
The following must be observed:
As the interference signals are frequently in a range > 10 kHz, a
large area shield connection is necessary.
The shield bar is very conductive and connected over a large
area with the switch cabinet housing and must be as near as
possible to the cable entry. The cable must be stripped and
connected to the grounding bar with an RF clip or cable tie.
The shielding bar must be connected with the PE bar.
If shielded cables have to be interrupted, the shield must
continue via the corresponding connector housing using
suitable connectors.
If intermediate connectors are used which do not feature a
suitable shield, the shield must be connected via cable clips to
the point where it is interrupted.
4 – 8 D101583 0207 BL ident
Page 51
Description of the data carrier
5 Description of the data carrier
Type overview...................................................................................................2
Function principle..............................................................................................3
Memory module ..................................... .....................................................3
Data carrier electronics...............................................................................4
Data carrier antenna............................... ...... ..... ........................................ ..4
Technical data
TW-R16-B64 ...............................................................................................5
TW-R16-B128 .............................................................................................7
TW-R20-B128 .............................................................................................9
TW-R30-B128 ...........................................................................................11
TW-R50-B128 ...........................................................................................13
TW-R20-K2................................................................................................15
TW-R30-K2................................................................................................17
TW-R50-K2................................................................................................19
TW-R22-HT-B64 .......................................................................................21
TW-R50-90-HT-B128................................................................................23
TW-R50-90-HT-K2....................................................................................25
TW-I14-B128.............................................................................................27
TW-L43-43-F-B128...................................................................................29
TW-L82-49-P-B128...................................................................................31
5
D101583 0207 BL ident
5 – 1
Page 52
Description of the data carrier
Type overview
Table 1: Data carrier type overview
Type Memory
TW-R16-B64 64 Byte EEPROM – TW-R16-B128 128 Byte EEPROM – TW-R20-B128 128 Byte EEPROM – TW-R30-B128 128 Byte EEPROM – TW-R50-B128 128 Byte EEPROM – TW-R20-K2 2 kByte FRAM – TW-R30-K2 2 kByte FRAM – TW-R50-K2 2 kByte FRAM – TW-R22-HT-B64 64 Byte EEPROM
size
Memory type
Highly
emperature
t resistant
TW-R50-90-HT-B128 128 Byte EEPROM TW-R50-90-HT-K2 2 kByte FRAM TW-I14-B128 128 Byte EEPROM – TW-L43-43-F-B128 128 Byte EEPROM – TW-L82-49-P-B128 128 Byte EEPROM
5 – 2 D101583 0207 BL ident
Page 53
Description of the data carrier
U
B
modulator
demodulator
control logicsmemory
read/write
Function principle
The BLident data carriers (TAGs) can be written and read on a non­contact basis using the correspondi ng read-write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. without batteries. If the dat a carriers enter the transfer range of a read-write head, the energy is inductively coupled and the data transfer is initiated.
The achievable distances vary depending on the sizes from 15…200 mm. All housing styles (with the exception of the TW-R16...-B128, EEPROM only) are available both as EEPROM and FRAM memory variants. The BLident data carrier consists of a memory module, electronics and an antenna (see Fig. 1).
Figure 1 Block diagram Data carrier
5
Memory module
The information on the data carrier can be read – and new data can also be added (read/write). The memory size is 64 Bytes, 128 Bytes or 2 KBytes.
The memory consists alternatively of the following compon ents:
EEPROM: unlimited read but limited write cycles are possible
5
). No battery required.
(10
FRAM = ferroelectric memory: unlimited read and almost
unlimited write cycles are possible (10
D101583 0207 BL ident
10
). No battery required.
5 – 3
Page 54
Description of the data carrier
The data retention time of the memory is:
1 year at 85 °C,10 years at 55 °C,120 years at 25 °C.
Electrical fields do not have an influence as they are normally have a frequency which is much too low to erase the memory.
Data carrier electronics
The electronics ensure the communication on the data carrier side with the read-write head.
Data carrier antenna
The antenna is designed as an air coil and is used to transfer data and energy between the data carrier and the read-write head.
5 – 4 D101583 0207 BL ident
Page 55
Description of the data carrier
2,5
16
3
Technical data TW-R16-B64
Figure 2 TW-R16-B64
Table 2: TW-R16-B64
Type
Ident-No.
Memory data
5
TW-R16-B64
6900???
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type EEPROM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C
D101583 0207 BL ident
13.56 MHz 128 Bytes
5
0.5…5 ms/Byte 3…6 ms/Byte
10 mm
5 – 5
Page 56
Description of the data carrier
Table 2: TW-R16-B64
Type
Ident-No. Storage temp er a t u re -25…+120 °C
TW-R16-B64
6900???
+160 °C (1 x 35 h) +220 °C (1 x 30 s)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material Epoxy, plastic-moulded
5 – 6 D101583 0207 BL ident
Page 57
Description of the data carrier
2,5
16
3
Technical data TW-R16-B128
Figure 3 TW-R16-B128
Table 3: TW-R16-B128
Type
Ident-No.
Memory data
5
TW-R16-B128
6900501
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type EEPROM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C
D101583 0207 BL ident
13.56 MHz 128 Bytes
5
0.5…5 ms/Byte 3…6 ms/Byte
10 mm
5 – 7
Page 58
Description of the data carrier
Table 3: TW-R16-B128
Type
Ident-No. Storage temp er a t u re -25…+120 °C
TW-R16-B128
6900501
+160 °C (1 x 35 h) +220 °C (1 x 30 s)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material Epoxy, plastic-moulded
5 – 8 D101583 0207 BL ident
Page 59
Description of the data carrier
1,5
ø 20
2,5
ø 20
Technical data TW-R20-B128
Figure 4 TW-R20-B128
Table 4: TW-R20-B128
Type
Ident-No.
Memory data
5
TW-R20-B128
6900502
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type EEPROM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C
D101583 0207 BL ident
13.56 MHz 128 Bytes
5
0.5…5 ms/Byte 3…6 ms/Byte
10 mm
5 – 9
Page 60
Description of the data carrier
Table 4: TW-R20-B128
Type
Ident-No. Storage temp er a t u re -40…+90 °C
TW-R20-B128
6900502
+140 °C (1 x 100 h)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material PA6
5 – 10 D101583 0207 BL ident
Page 61
Description of the data carrier
1,5
ø 30
ø 3,2
2,5
ø 30
ø 5,2
Technical data TW-R30-B128
Figure 5 TW-R30-B128
Table 5: TW-R30-B128
Type
Ident-No.
Memory data
5
TW-R30-B128
6900503
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type EEPROM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C
D101583 0207 BL ident
13.56 MHz 128 Bytes
5
0.5…5 ms/Byte 3…6 ms/Byte
10 mm
5 – 11
Page 62
Description of the data carrier
Table 5: TW-R30-B128
Type
Ident-No. Storage temp er a t u re -40…+90 °C
TW-R30-B128
6900503
+140 °C (1 x 100 h)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material PA6
5 – 12 D101583 0207 BL ident
Page 63
Description of the data carrier
1,5
ø 50
ø 4,2
3
ø 50
ø 5,2
Technical data TW-R50-B128
Figure 6 TW-R50-B128
Table 6: TW-R50-B128
Type
Ident-No.
Memory data
5
TW-R50-B128
6900504
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type EEPROM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C
D101583 0207 BL ident
13.56 MHz 128 Bytes
5
0.5…5 ms/Byte 3…6 ms/Byte
10 mm
5 – 13
Page 64
Description of the data carrier
Table 6: TW-R50-B128
Type
Ident-No. Storage temp er a t u re -40…+90 °C
TW-R50-B128
6900504
+140 °C (1 x 100 h)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material PA6
5 – 14 D101583 0207 BL ident
Page 65
Description of the data carrier
2,5
ø 20
Technical data TW-R20-K2
Figure 7 TW-R20-K2
Table 7: TW-R20-K2
Type
Ident-No.
Memory data
5
TW-R20-K2
6900505
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type FRAM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -20…+85 °C
D101583 0207 BL ident
13.56 MHz 2 KBytes
10
0.5…5 ms/Byte
0.5…5 ms/Byte
10 mm
5 – 15
Page 66
Description of the data carrier
Table 7: TW-R20-K2
Type
Ident-No. Storage temp er a t u re -20…+85 °C
TW-R20-K2
6900505
+140 °C (1 x 100 h)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material PA6
5 – 16 D101583 0207 BL ident
Page 67
Description of the data carrier
2,5
ø 30
ø 5,2
Technical data TW-R30-K2
Figure 8 TW-R30-K2
Table 8: TW-R30-K2
Type
Ident-No.
Memory data
5
TW-R30-K2
6900506
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type FRAM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -20…+85 °C
D101583 0207 BL ident
13.56 MHz 2 KBytes
10
0.5…5 ms/Byte
0.5…5 ms/Byte
10 mm
5 – 17
Page 68
Description of the data carrier
Table 8: TW-R30-K2
Type
Ident-No. Storage temp er a t u re -20…+85 °C
TW-R30-K2
6900506
+140 °C (1 x 100 h)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material PA6
5 – 18 D101583 0207 BL ident
Page 69
Description of the data carrier
3
ø 50
ø 5,2
Technical data TW-R50-K2
Figure 9 TW-R50-K2
Table 9: TW-R50-K2
Type
Ident-No.
Memory data
5
TW-R50-K2
6900507
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type FRAM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -20…+85 °C
D101583 0207 BL ident
13.56 MHz 2 KBytes
10
0.5…5 ms/Byte
0.5…5 ms/Byte
10 mm
5 – 19
Page 70
Description of the data carrier
Table 9: TW-R50-K2
Type
Ident-No. Storage temp er a t u re -20…+85 °C
TW-R50-K2
6900507
+140 °C (1 x 100 h)
Degree of protection (IEC
IP68
60529/EN 60529) Housing material PA6
5 – 20 D101583 0207 BL ident
Page 71
Description of the data carrier
30
125
10
ø 22
Technical data TW-R22-HT-B64
Figure 10 TW-R22-HT-B64
5
Table 10: TW-R22-HT-B64
Type
Ident-No.
TW-R22-HT-B64
1542323
Memory data
Operating frequency Memory size
13.56 MHz 64 Bytes
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
5
0.5…5 ms/Byte 3…6 ms/Byte
Memory type EEPROM
Installation guidelines
Minimum distances when
10 mm mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C (time-dependent)
D101583 0207 BL ident
5 – 21
Page 72
Description of the data carrier
Table 10: TW-R22-HT-B64
Type
Ident-No.
TW-R22-HT-B64
1542323 Storage temp er a t u re -40…+210 °C Degree of protection (IEC
IP68 60529/EN 60529)
Housing material PA66
5 – 22 D101583 0207 BL ident
Page 73
Description of the data carrier
ø 95
ø 108,5 ø 136,5 ø 125
68
ø 5,5 (3 x 120°)
Technical data TW-R50-90-HT-B 128
Figure 11 TW-R50-90-HT­B128
5
Table 11: TW-R50-90HT­B128
Type
Ident-No.
Memory data
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type EEPROM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C (time-dependent)
D101583 0207 BL ident
TW-R50-90-HT-B128
1542326
13.56 MHz
128 Bytes
5
0.5…5 ms/Byte
3…6 ms/Byte
5 – 23
Page 74
Description of the data carrier
Table 11: TW-R50-90HT­B128
Type
Ident-No.
TW-R50-90-HT-B128
1542326
Storage temp er a t u re -40…+210 °C Degree of protection (IEC
IP67 60529/EN 60529)
Housing material PA66
5 – 24 D101583 0207 BL ident
Page 75
Description of the data carrier
ø 95
ø 108,5 ø 136,5 ø 125
68
ø 5,5 (3 x 120°)
Technical data TW-R50-90-HT-K2
Figure 12 TW-R50-90-HT­K2
5
Table 12: TW-R50-90-HT­K2
Type
Ident-No.
Memory data
Operating frequency Memory size
Number of read operations unlimited Number of write operations 10
Read time (typical) Write time (typical)
Memory type FRAM
Installation guidelines
Minimum distances when mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -20…+85 °C (time-dependent)
D101583 0207 BL ident
TW-R50-90-HT-K2
1542329
13.56 MHz
2 KBytes
10
0.5…5 ms/Byte
0.5…5 ms/Byte
5 – 25
Page 76
Description of the data carrier
Table 12: TW-R50-90-HT­K2
Type
Ident-No.
TW-R50-90-HT-K2
1542329
Storage temp er a t u re -40…+210 °C Degree of protection (IEC
IP68 60529/EN 60529)
Housing material PA66
5 – 26 D101583 0207 BL ident
Page 77
Description of the data carrier
14
Technical data TW-I14-B128
Figure 13 TW-I14-B128
5
Table 13: TW-I14-B128
Type
Ident-No.
TW-I14-B128
6900526
Memory data
Operating frequency Memory size
13.56 MHz
128 Bytes Number of read operations unlimited
Number of write operations 10 Read time (typical) Write time (typical)
5
0.5…5 ms/Byte
3…6 ms/Byte Memory type EEPROM
Installation guidelines
Minimum distances when
10 mm mounting in metal (around the data carrier)
General data
Colour black Ambient temperature -25…+85 °C
D101583 0207 BL ident
5 – 27
Page 78
Description of the data carrier
Table 13: TW-I14-B128
Type
Ident-No.
TW-I14-B128
6900526 Storage temp er a t u re -25…+120 °C
+160 °C (1 x 35 h)
+220 °C ( 1 x 30 s) Degree of protection (IEC
IP10 60529/EN 60529)
Housing material Epoxy foil
5 – 28 D101583 0207 BL ident
Page 79
Description of the data carrier
43
43
Technical data TW-L43-43-F-B128
Figure 14 TW-L43-43-F­B128
5
Table 14: TW-L43-43-F­B128
Type
Ident-No.
TW-L43-43-F-B128
6901344
Memory data
Operating frequency Memory size
13.56 MHz
128 Bytes Number of read operations unlimited
Number of write operations 10 Read time (typical) Write time (typical)
5
0.5…5 ms/Byte
3…6 ms/Byte Memory type EEPROM
Installation guidelines
Minimum distances when
10 mm mounting in metal (around the data carrier)
General data
Colour white Ambient temperature -20…+70 °C
D101583 0207 BL ident
5 – 29
Page 80
Description of the data carrier
Table 14: TW-L43-43-F­B128
Type
Ident-No.
TW-L43-43-F-B128
6901344
Storage temp er a t u re -20…+70 °C Degree of protection (IEC
IP40 60529/EN 60529)
Housing material Foil, self-adhesive
5 – 30 D101583 0207 BL ident
Page 81
Description of the data carrier
49
82
Technical data TW-L82-49-P-B128
Figure 15 TW-L82-49-P­B128
5
Table 15: TW-L82-49-P­B128
Type
Ident-No.
TW-L82-49-P-B128
6901345
Memory data
Operating frequency Memory size
13.56 MHz
128 Bytes Number of read operations unlimited
Number of write operations 10 Read time (typical) Write time (typical)
5
0.5…5 ms/Byte
3…6 ms/Byte Memory type EEPROM
Installation guidelines
Minimum distances when
10 mm mounting in metal (around the data carrier)
General data
Colour white Ambient temperature -20…+70 °C
D101583 0207 BL ident
5 – 31
Page 82
Description of the data carrier
Table 15: TW-L82-49-P­B128
Type
Ident-No.
TW-L82-49-P-B128
6901345
Storage temp er a t u re -20…+70 °C Degree of protection (IEC
IP40 60529/EN 60529)
Housing material Paper, self-adhesive
5 – 32 D101583 0207 BL ident
Page 83
Description of the read-write heads
6 Description of the read-write heads
Type overview......................................................... ..........................................2
Function principle..............................................................................................3
Read-write head electronics ........................................ ... ... .........................3
Read-write head antenna............................................. ... ............................4
Technical data of the read-write heads
TB-M18-H1147............................................................................................6
TB-M18-H1147/S1126 (optimised for special data carriers).......................7
TB-EM18WD-H1147 (wash-down)..............................................................8
TB-EM18WD-H1147/S1126 (wash-down, optimised for special data
carriers) .......................................................................................................9
TN-M18-H1147 .........................................................................................10
TN-M18-H1147/S1126 (optimised for special data carriers)....................11
TN-EM18WD-H1147 (wash-down)..................................................... ... ... .12
TN-EM18WD-H1147/S1126 (wash-down, optimised for special data
carriers)......................................................................................................13
TB-M30-H1147..........................................................................................14
TB-M30-H1147/S1126 (optimised for special data carriers).....................15
TB-EM30WD-H1147 (wash-down)............................................................16
TB-EM30WD-H1147/S1126 (wash-down, optimised for special data
carriers)......................................................................................................17
TN-M30-H1147 .........................................................................................18
TN-M30-H1147/S1126 (optimised for special data carriers)....................19
TN-EM30WD-H1147 (wash-down)..................................................... ... ... .20
TN-EM30WD-H1147/S1126 (wash-down, optimised for special data
carriers)......................................................................................................21
TN-CK40-H1147........................................................................................22
TN-CK40-H1147/S1126 (optimised for special data carriers)...................23
TN-Q80-H1147..........................................................................................24
TN-Q80-H1147/S1126 (optimised for special data carriers).....................25
TNER-Q80-H1147 (increased range).........................................................26
TNLR-Q80-H1147 (long range) .................................................................27
TNLR-Q80-H1147/S1126 (long range, optimised for special
data carriers).................................. ... .......................................... ...............28
TN-S32XL-H1147......................................................................................29
Connection of the read-write heads ...............................................................30
6
D101583 0207 BL ident
6 – 1
Page 84
Description of the read-write heads
Type overview
Table 1: Type overview read-write heads
Type Installa-
tion
onditions
c
Output function
Connec­tion
TB-M18-H1147 TB-M18-H1147/S1126 TB-EM18WD-H1147 TB-EM18WD-H1147/S1126
TN-M18-H1147 TN-M18-H1147/S1126 TN-EM30WD-H1147 TN-EM30WD-H1147/S1126
TB-M30-H1147 TB-M30-H1147/S1126 TB-EM30WD-H1147 TB-EM30WD-H1147/S1126
TN-M30-H1147 TN-M30-H1147/S1126 TN-EM30WD-H1147 TN-EM30WD-H1147/S1126
TN-CK40-H1147 TN-CK40-H1147/S1126
TN-Q80-H1147 TN-Q80-H1147/S1126 TNER-Q80-H1147 TNLR-Q80-H1147 TNLR-Q80-H1147/S1126
flush Read/write via
BLident cable
non­flush
Read/write via
BLident cable
flush Read/write via
BLident cable
non­flush
Read/write via
BLident cable
non­flush, (flush
Read/write via
BLident
cable instal­lation possible)
non­flush, (installatio
Read/write via
BLident
cable n on metal possible)
TN-S32XL-H1147 non-
flush (
installation
Read/write via
BLident
cable on metal possible)
6 – 2 D101583 0207 BL ident
Page 85
Description of the read-write heads
Modulator
Demodulator
Generator
Function principle
The BLident read-write heads (transceivers) are used for non­contact data exchange with the corresponding data carriers (TAGs). They form the so-called air-interface (transfer window), whose size varies depending on the combination of data carrier and transceiver. In this air-interface the data carrier is supplied with energy and the exchange of data is also implemented. The operating frequency is
13.56 MHz. The achievable distances vary depending on the sizes from 15…200 mm. The read-write heads consist of electronics and an antenna. (Figure 1)
Figure 1 Block diagram Read-write head
6
Read-write head electronics
The electronics ensure the communication between the data carrier, the read-write head and the BLident interface module.
D101583 0207 BL ident
6 – 3
Page 86
Description of the read-write heads
Read-write head antenna
The antenna consists of an air coil. It is used to transfer data and energy between the data carrier and the read-write head. The antenna generates an electromagnetic field which is detected by the data carrier within the transfer zone. A data and energy transfer is only possible as long as the data carrier is located in this field (Figure 2).
Figure 2 Transfer zone
6 – 4 D101583 0207 BL ident
Page 87
Description of the read-write heads
24/4
56
72
LED
M18 x 1
9
M12 x 1
Technical data TB-M18-H1147
Figure 3 TB-M18-H1147
Table 2: TB-M18-H1147
Type
Ident-No.
Mounting condition flush
6
TB-M18-H1147
7030001
Ambient temperature
Data transfer
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
D101583 0207 BL ident
-25…+ 70 °C inductive
Threaded barrel, M18 × 1 Metal, CuZn, chrome-plated
55 Hz (1 mm)
6 – 5
Page 88
Description of the read-write heads
24/4
56
72
LED
M18 x 1
9
M12 x 1
Technical data TB-M18-H1147/S1126
Figure 4 TB-M18-H1147/ S1126
Table 3:TB-M18­H1147/S1126
Type
Ident-No.
TB-M18-H1147/S1126
7030212
Mounting condition flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Threaded barrel, M18 × 1 Metal, CuZn, chrome-plated
Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance
55 Hz (1 mm)
Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
6 – 6 D101583 0207 BL ident
Page 89
Description of the read-write heads
24/4
56
72
LED
M18 x 1
9
M12 x 1
Technical data TB-EM18WD-H1147
Figure 5 TB-EM18WD­H1147
6
Table 4:TB­EM18WD-H1147
Type
Ident-No. Mounting condition flush
Ambient temperature
Data transfer
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Active face material Plastic, LCP-GF30 Connection Connector, M12 × 1
Vibration resistance Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
D101583 0207 BL ident
TB-EM18WD-H1147
7030224
-25…+ 70 °C inductive
Threaded barrel, M18 × 1 Metal, A4 1.4404 (AISI 316L)
55 Hz (1 mm)
6 – 7
Page 90
Description of the read-write heads
24/4
56
72
LED
M18 x 1
9
M12 x 1
Technical data TB-EM18WD-H1147/S1126
Figure 6 TB-EM18WD­H1147/S1126
Table 5:TB-EM18 WD-H1147/S1126
Type
Ident-No.
TB-EM18WD-H1147/S1126
7030228
Mounting condition flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Threaded barrel, M18 × 1 Metal, A4 1.4404 (AISI 316L)
Active face material Plastic, LCP-GF30 Connection Connector, M12 × 1
Vibration resistance
55 Hz (1 mm)
Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
6 – 8 D101583 0207 BL ident
Page 91
Description of the read-write heads
24/4
56
72
M18 x 1
9
10
LED
M12 x 1
Technical data TN-M18-H1147
Figure 7 TN-M18-H1147
Table 6: TN-M18-H1147
Type
Ident-No.
Mounting condition non-flush
6
TN-M18-H1147
7030002
Ambient temperature
Data transfer
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
D101583 0207 BL ident
-25…+ 70 °C inductive
Threaded barrel, M18 × 1 Metal, CuZn, chrome-plated
55 Hz (1 mm)
6 – 9
Page 92
Description of the read-write heads
24/4
56
72
M18 x 1
9
10
LED
M12 x 1
Technical data TN-M18-H1147/S1126
Figure 8 TN-M18-H1147/ S1126
Table 7:TN-M18­H1147/S1126
Type
Ident-No.
TN-M18-H1147/S1126
7030213
Mounting condition non-flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Threaded barrel, M18 × 1 Metal, CuZn, chrome-plated
Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance
55 Hz (1 mm)
Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
6 – 10 D101583 0207 BL ident
Page 93
Description of the read-write heads
24/4
56
72
M18 x 1
9
10
LED
M12 x 1
Technical data TN-EM18WD-H1147
Figure 9 TN-EM18WD­H1147
6
Table 8:TN­EM18WD-H1147
Type
Ident-No. Mounting condition non-flush
Ambient temperature
Data transfer
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Active face material Plastic, LCP-GF30 Connection Connector, M12 × 1
Vibration resistance Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
D101583 0207 BL ident
TN-EM18WD-H1147
7030223
-25…+ 70 °C inductive
Threaded barrel, M18 × 1 Metal, A4 1.4404 (AISI 316L)
55 Hz (1 mm)
6 – 11
Page 94
Description of the read-write heads
24/4
56
72
M18 x 1
9
10
LED
M12 x 1
Technical data TN-EM18WD-H1147/S1126
Figure 10 TN-EM18WD­H1147/S1126
Table 9:TN-EM18 WD-H1147/S1126
Type
Ident-No.
TN-EM18WD-H1147/S1126
7030227
Mounting condition non-flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style Housing material
Threaded barrel, M18 × 1 Metal, A4 1.4404 (AISI 316L)
Active face material Plastic, LCP-GF30 Connection Connector, M12 × 1
Vibration resistance
55 Hz (1 mm)
Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
6 – 12 D101583 0207 BL ident
Page 95
Description of the read-write heads
36/5
46
62
LED
M30 x 1,5
9
M12 x 1
Technical data TB-M30-H1147
Figure 11 TB-M30-H1147
Table 10: TB-M30-H1147
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Type
Ident-No.
TB-M30-H1147
7030003
Mounting condition flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style
Threaded barrel, M30 × 1.5
6
Housing material Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
D101583 0207 BL ident
Metal, CuZn, chrome-plated
55 Hz (1 mm)
6 – 13
Page 96
Description of the read-write heads
36/5
46
62
LED
M30 x 1,5
9
M12 x 1
Technical data TB-M30-H1147/S1126
Figure 12 TB-M30-H1147/ S1126
Table 11:TB-M30
-H1147/S1126
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Type
Ident-No.
TB-M30-H1147/S1126
7030214
Mounting condition flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style
Threaded barrel, M30 × 1.5
Housing material
Metal, CuZn, chrome-plated
Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance
55 Hz (1 mm)
Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
6 – 14 D101583 0207 BL ident
Page 97
Description of the read-write heads
36/5
46
62
LED
M30 x 1,5
9
M12 x 1
Technical data TB-EM30WD-H1147
Figure 13 TB-EM30WD­H1147
Table 12:TB­EM30WD-H1147
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Type
Ident-No.
TB-EM30WD-H1147
7030221
Mounting condition flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style
Threaded barrel, M30 × 1.5
6
Housing material Active face material Plastic, LCP-GF30 Connection Connector, M12 × 1
Vibration resistance Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
D101583 0207 BL ident
Metal, A4 1.4404 (AISI 316L)
55 Hz (1 mm)
6 – 15
Page 98
Description of the read-write heads
36/5
46
62
LED
M30 x 1,5
9
M12 x 1
Technical data TB-EM30WD-H1147/S1126
Figure 14 TB-EM30WD­H1147/S1126
Table 13: WD-H1147/S1126
TB-EM30
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Type
Ident-No.
TB-EM30WD-H1147/S1126
7030225
Mounting condition flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style
Threaded barrel, M30 × 1.5
Housing material
Metal, A4 1.4404 (AISI 316L)
Active face material Plastic, LCP-GF30 Connection Connector, M12 × 1
Vibration resistance
55 Hz (1 mm)
Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
6 – 16 D101583 0207 BL ident
Page 99
Description of the read-write heads
36/5
46
62
LED
M30 x 1,5
9
15
M12 x 1
Technical data TN-M30-H1147
Figure 15 TN-M30-H1147
Table 14: TN-M30-H1147
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Type
Ident-No.
TN-M30-H1147
7030004
Mounting condition non-flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style
Threaded barrel, M30 × 1.5
6
Housing material Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
D101583 0207 BL ident
Metal, CuZn, chrome-plated
55 Hz (1 mm)
6 – 17
Page 100
Description of the read-write heads
36/5
46
62
LED
M30 x 1,5
9
15
M12 x 1
Technical data TN-M30-H1147/S1126
Figure 16 TN-M30-H1147/ S1126
Table 15:TN-M30­H1147/S1126
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Type
Ident-No.
TN-M30-H1147/S1126
7030215
Mounting condition non-flush Ambient temperature
Data transfer
-25…+ 70 °C inductive
Output function Read/write Operating frequency 13.56 MHz
Housing style
Threaded barrel, M30 × 1.5
Housing material
Metal, CuZn, chrome-plated
Active face material Plastic, PA12-GF30 Connection Connector, M12 × 1
Vibration resistance
55 Hz (1 mm)
Shock resistance 30 g (11 ms) Degree of protection IP67 Power ON indication Green LED Function display Green LED, flashing
6 – 18 D101583 0207 BL ident