DE Gebrauchsanleitung / Montageanleitung 2
FR Mode d‘emploi / Instructions de montage 3
EN Instructions for use / assembly instructions 4
IT Istruzioni per l‘uso / Istruzioni per Installazione 5
ES Modo de empleo / Instrucciones de montaje 6
NL Gebruiksaanwijzing / Handleiding 7
DK Brugsanvisning / Monteringsvejledning 8
PT Instruções para uso / Manual de Instalación 9
PL Instrukcja obsługi / Instrukcja montażu 10
CS Návod k použití / Montážní návod 11
SK Návod na použitie / Montážny návod 12
ZH Ⴆ൫Ҧ / ቄላඨૺ 13
RU Руководство пользователя / Инструкция по
монтажу 14
HU Használati útmutató / Szerelési útmutató 15
FI Käyttöohje / Asennusohje 16
SV Bruksanvisning / Monteringsanvisning 17
LT Vartotojo instrukcija / Montavimo instrukcijos 18
HR Upute za uporabu / Uputstva za instalaciju 19
TR Kullanım kılavuzu / Montaj kılavuzu 20
RO Manual de utilizare / Instrucţiuni de montare 21
EL Οδηγίες χρήσης / Οδηγία συναρμολόγησης 22
SL Navodilo za uporabo / Navodila za montažo 23
ET Kasutusjuhend / Paigaldusjuhend 24
LV Lietošanas pamācība / Montāžas instrukcija 25
SR Uputstvo za upotrebu / Uputstvo za montažu 26
NO Bruksanvisning / Montasjeveiledning 27
BG Инструкция за употреба / Ръководство за
монтаж 28
SQ Udhëzuesi i përdorimit / Udhëzime rreth montimit 29
AR
ǕƸƵƆƄŽȚȝƾƵƸƴƯů /ȳȚNjƈƄŴǽȚǚƸŽȢ 30
Talis Classic
14165XXX
PuraVida
15665XXX
Metris
31675000
Focus S
31763000
Metris
31685000
Metropol S
14665000
Metris S
31665000
Metris Classic
31676XXX
Focus
31965000
Metropol E
14675000
Talis E²
31666000
Focus E
31761000
Talis S / Talis
32675000

English
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
Technical Data
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Thermal disinfection: max. 70°C / 4 min
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 33. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Dimensions (see page 34)
Flow diagram
(see page 35)
Operation (see page 38)
Cleaning
see enclosed brochure.
Spare parts (see page 36)
XXX = Colors
000 = chrome plated
400 = white/chrome plated
820 = brushed nickel
Test certificate (see page 40)
Fault Cause Remedy
Mixer stiff - Cartridge defective, calcified - Exchange cartridge
Mixer dripping - Cartridge defective, sedimentation - Exchange cartridge
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
- Hot water limiter incorrectly set - Set hot water limiter
- Crossflow - Exchange cartridge