2
Technical Data
Operating pressure: max. 145 psi
Recommended operating pressure:
14.5 - 72 psi
Hot water temperature: max. 176° F*
Recommended hot water temperature:
120°F - 140°F*
Center distance: 6
3/4
“ ± 1
3/4
“
Connections ½" female: cold right
hot left
Tub filler flow rate @ 45 psi
approx. 5.8 gpm
Flow rate for handshower 2.5 gpm
Backflow prevention provided by check valve.
This unit is not anti-scald. If required by local plum
-
bing code, install with remote pressure balance valve
13418181.
*Know and follow all applicable local plumbing codes when setting the
temperature on the water heater.
Montreux
Wall-Mount Tub Filler 16540XX1
Wall-Mount Shower Mixer 16560XX1
16540XX1 16560XX1
3
Installation
During rough-in, install two 1/2” female threaded
fittings, recessed 3/16” behind the surface of the
finished wall. The fittings should be 6 3/4” apart on
center.
Flush the hot and cold supplies thoroughly.
Wrap the threads on the offset adapters with
Teflon
TM
thread tape. Screw the adapers into the
female fittings. The adapters should extend 1
7/16” - 1 5/8” outside the surface of the finished
wall.
Adjust the offset adapters so that the distance
between the centers is 6 3/4”, and they are level.
Seal the wall around the adapters with waterproof bathroom sealant.
1 7/16” - 1 5/8”