Hansgrohe 15741000, 15760000, 15734400 Instructions For Use And Assembly Instructions

DE Gebrauchsanleitung / Montageanleitung 2 FR Mode d'emploi / Instructions de montage 4 EN Instructions for use / assembly instructions 6 IT Istruzioni per l'uso / Istruzioni per Installazione 8 ES Modo de empleo / Instrucciones de montaje 10 NL Gebruiksaanwijzing / Handleiding 12 DK Brugsanvisning / Monteringsvejledning 14 PT Instruções para uso / Manual de Instalación 16 PL Instrukcja obsługi / Instrukcja montażu 18 CS Návod k použití / Montážní návod 20 SK Návod na použitie / Montážny návod 22 ZH 用户手册/组装说明 24 RU Руководство пользователя / Инструкция
по монтажу 26
HU Használati útmutató / Szerelési útmutató 28 FI Käyttöohje / Asennusohje 30 SV Bruksanvisning / Monteringsanvisning 32 LT Vartotojo instrukcija / Montavimo instrukcijos 34 HR Upute za uporabu / Uputstva za instalaciju 36 TR Kullanım kılavuzu / Montaj kılavuzu 38 RO Manual de utilizare / Instrucţiuni de montare 40 EL Οδηγίες χρήσης / Οδηγία συναρμολόγησης 42 SL Navodilo za uporabo / Navodila za montažo 44 ET Kasutusjuhend / Paigaldusjuhend 46 LV Lietošanas pamācība / Montāžas instrukcija 48 SR Uputstvo za upotrebu / Uputstvo za montažu 50 NO Bruksanvisning / Montasjeveiledning 52 BG Инструкция за употреба / Ръководство
за монтаж 54
SQ Udhëzuesi i përdorimit / Udhëzime rreth montimit 56 AR
 59
°C
40
ShowerSelect S
15741000
°C
40
ShowerSelect
15760000
°C
40
ShowerSelect
English
Safety Notes
 The product may only be used for bathing, hygienic
and body cleaning purposes.
 Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate distance must be kept between the shower and you.
 The product may only be used for bathing, hygienic
and body cleaning purposes.
 The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
Technical Data
Operating pressure: max. 1MPa Recommended operating pressure: 0,1 - 0,5 MPa Test pressure: 1,6 MPa (1 MPa = 10 bar = 147 PSI) Hot water temperature: max. 70°C Recommended hot water temp.: 65°C Thermal disinfection: max. 70°C / 4 min.
Safety against backflow
The product is exclusively designed for drinking water!
This mixer cannot be used in conjunction with hydrauli­cally, electronically or thermally controlled instantaneous heaters.
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 63)
After the installation, the output tempera­ture of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.
Safety Function (see page 64)
The desired maximum temperature for exam­ple max. 42º C can be pre-set thanks to the safety function.
Maintenance (see page 66)
• The mixer is equipped with check valves. The check valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
Dimensions (see page 68)
Flow diagram
(see page 68)
Rate of flow by 0,3 MPa:
6
English
Test certificate (see page 72)Operation (see page 63)
Spare parts (see page 69)
Colors
000 = chrome plated 400 = white/chrome plated 600 = black/chrome plated
Fault Cause Remedy
Insufficient water - Supply pressure inadequate - Check water pressure (If a pump
- Filters are dirty - Clean filter in front of the mixer and
- Shower filter seal dirty - Clean filter seal between shower
Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed Spout temperature does not cor­respond with temperature set
Temperature regulation not possible - Temperature regulator dirty or
Safety stop button not operating - Spring defective - Clean spring and/or button, ex-
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted - Adjust thermostat
- Hot water temperature too low - Increase hot water temperature to
calcified
- For new installations: basic body incorrectly connected (should be: cold right, hot left) or installed with 180º rotation
- Button calcified
Cleaning
see enclosed brochure
has been installed check to see if the pump is working).
on the MTC-thermo cartridge
and hose
change if necessary
42 ºC to 65 ºC
- Clean temperature regulator, ex- change if necessary
- Install function block turned through 180º
change if necessary
Assembly see page 60
7
01800180
1
2 3
1.
4 5
2.
1.
2.
3.
SW 4 mm
5 Nm
SW 5 mm
4.
1 - 2 mm
X
1.
2.
X + 11
60
6 7
0,1 Nm
!
8 9
°C
40
15741000 15760000
!
10a
40
1.
°C
15741000 15760000
2 Nm
SW 3 mm
2.
10b
1.
15734400 15734600
°C
40
!
15734400 15734600
°C
40
SW 3 mm
4 Nm
2.
61
Loading...