HighArc Bar Faucets
06688XX0 Solaris E
06696XX0 Stratos E
06699XX0 Metro E
06857XX0 Talis S
Allegro E 14801XX1
see page 5
Technical Specification
Recommended water pressure 14.7 - 72.5 PSI
Recommended hot water temp. 120° - 140° F*
Hole size in mounting surface 1-1/2”
Max. mounting surface thickness 2 3/8”
Max. flow rate 1.5 GPM
*Please know and follow all applicable local codes when setting the temperature on the water heater.
Installation Considerations
For best results, Hansgrohe recommends that this unit be installed by a licensed, profes-
•
sional plumber.
Please read over these instructions thoroughly before beginning installation. Make sure
•
that you have all tools and supplies needed to complete the installation.
The hot and cold supply hoses connect to the stops with 3/8” compression fittings
•
(included).
Flush the hot and cold supplies thoroughly before installing this faucet. Debris in the
•
water line may damage the ceramic cartridge.
2
Installation
Push the spout into place on the faucet. Tighten
the spout set screw.
Place the faucet and sealing washer on the mounting surface.
English
If the mounting surface is less than 1 3/8”, install
the plastic washer, fiber washer, friction washer,
and mounting nut.
If the mounting surface is greater than 1 3/8”,
omit the plastic washer.
Tighten the mounting nut. Tighten the tensioning
screws.
Install the hot and cold supply lines to the stops
with 3/8” compression fittings (included).
Use two wrenches, as shown, to prevent the supply
hoses from twisting.
Do not allow either hose to twist.
Twisting the supply hose may cause
it to loosen from the faucet, which
may cause water damage.
For proper operation of the faucet, the hot supply
should be on the left, and the cold supply should
be on the right.
Turn on the water and check all connections for
leaks.
3
English
Install the handle
Install the handle screw on the cartridge stem.
Tighten only 4 turns.
Place the handle over the stem and handle screw.
Press it firmly into place.
Use a 4 mm Allen wrench to finish tightening the
screw.
Install the screw cover.
User Instructions
Push the handle to the right to turn the water on. Push it back to the left to turn the water off.
Swivel the handle forward for cooler water, backward for warmer water.
If the flow of water diminishes, remove and clean the aerator.
Faucet “Lay Down” Function
To provide clearance for opening a window, or for
ease of cleaning, the faucet can be laid down on
the counter without uninstalling it. Pull up on the
faucet body, then gently lay the faucet down on
the countertop. Do not pull the faucet by the neck!
When replacing the faucet, make sure that the pin
on the bottom of the faucet goes into the hole on
the base. Push the faucet down firmly against the
base.
4
Allegro E Bar Faucet
14801XX1
English
Technical Specification
Recommended water pressure 14.7 - 72.5 PSI
Recommended hot water temp. 120° - 140° F*
Hole size in mounting surface 1-1/2”
Max. mounting surface thickness 2 3/8”
Max. flow rate 1.5 GPM
*Please know and follow all applicable local codes when setting the temperature on the water heater.
Installation Considerations
For best results, Hansgrohe recommends that this unit be installed by a licensed, profes-
•
sional plumber.
Please read over these instructions thoroughly before beginning installation. Make sure
•
that you have all tools and supplies needed to complete the installation.
The hot and cold supply hoses connect to the stops with 3/8” compression fittings
•
(included).
Flush the hot and cold supplies thoroughly before installing this faucet. Debris in the
•
water line may damage the ceramic cartridge.