Technical data
Hole size in deck Spout: min.1 1/4"
max.1 5/8"
Hole size in deck Valve: min.1 1/8"
max. 1 1/4"
Steel
35033801
Operating pressure: max. 147 psi
Recommended operating press.:14.7 - 72.5 psi
Test pressure: 232 psi
Hot water temperature: max. 176° F
Recommended hot water temp.: 149° F
Assembly
1. Flush pipe lines thoroughly.
2. Mount spout and valves onto lavatory. The
hot water supply (red point on valve) should
be connected to the LHS and the cold on
the RHS.
3. Screw pop-up rod onto the pop-up rod
extending from faucet.
4. Starck/Allegroh:
Attach compression "Y" onto bottom of
spout fitting. Screw in stainless steel flex
hose connectors into "Y" and onto side
outlet of hot and cold valves.
Carlton/Phoenix/Terrano/Steel:
Connect flex hose with valves.
5. Attach handle trim and connect pop-up
assembly.
6. Turn on supply stops and check function of
faucet.
7. Check all connections for leakage.
Major pressure differences between
cold and hot water in supply should be
avoided and balanced.
3