Hans Grohe 06061XX0 User Manual

Installation Instructions / Warranty
ThermoBalance I Trim Kits
C Lever
06061XX0
Solaris² E
04146XX0
31316XX1
C Scroll
06062XX0
Allegro² E
04152XX0
Focus S
31735XX1
C Cross
06063XX0
Metro² E
04158XX0
Talis S
32316XX1
English
These instructions cover these models:
Valve trim Shower set only trim C Lever 06061XX0 06079XX0 C Scroll 06062XX0 06080XX0 C Cross 06063XX0 06081XX0 Solaris² E 04146XX0 04149XX0 Allegro² E 04152XX0 04155XX0 Metro² E 04158XX0 04161XX0 Metris S 31316XX1 31323XX1 Focus S 31735XX1 31771XX1 Talis S 32316XX1 32323XX1 Solaris E 06635XX0 06641XX0 Stratos E 06579XX0 06585XX0 Metro E 06655XX0 06661XX0
06061XX0 06062XX0 06063XX0
These trim kits are for use with the following rough valves:
ThermoBalance I rough valves 06621000, 06622000 ThermoBalance I rough valves with bypass 06300000, 06301000
04146XX0 04152XX0 04158XX0
31316XX1 31735XX1 32316XX1
06635XX0 06579XX0 06655XX0
2
Technical Information
Recommended pressure 45 - 72 psi Max hot water temperature 165 F* Recommended incoming hot water temp. 120° - 140° F* With rough valve 06621000, 06622000 Nominal capacity @ 45 PSI 9.5 gpm Nominal capacity @ 60 PSI 11.5 gpm With rough valve with bypass 06300000, 06301000 Nominal capacity @ 45 PSI 6.0 gpm Nominal capacity @ 60 PSI 6.5 gpm Safety stop 100° F Maximum output temperature 110° F** 1/2” NPT Connections
Listed by UL
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. **The high temperature limit stop may be reset to comply with local plumbing codes. See page 8.
Installation
Turn the water off at the main, or at the stops, before beginning.
Cut the installation box (i-box) so that it extends 1/16” outside the finished wall.
English
Seal the wall around the i-box with waterproof sealant.
Failure to seal the wall can lead to possible water damage.
Remove the label. Cut the support arms that connect the flushing plug to the installation box. Remove the flushing plug. Do not dis-
card the screws.
Be sure that the blue sealing
gasket is removed as well.
Failure to remove the gasket
can result in possible damage to the cartridge and possible water damage.
3
English
Insert the cartridge in the rough. The locator tab on the cartridge goes straight into the notch in the rough*.
notch
positioning pin hole
*Note: The earlier version of the ThermoBalance I rough does
locator tab
not have the notch for the locator tab. See page 6 for cartridge modification instructions.
The positioning pin on the back of the cartridge goes straight into the hole in the rough. Use the reserved screws to connect the cartridge retainer plate to the rough. Tighten the
screws evenly, using a manual screwdriver, in a cross-wise pattern. Do not overtighten
the screws.
Perform the following test to check for damage to the ceramic plates inside the stop unit.
Failure to correctly perform this test can result in possible water damage.
Turn on the water supplies. Grasp the stop unit portion of the cartridge and turn it.
If there is a leak around the cartridge, turn the supplies off, and remove the cartridge. Confirm that the sealing gasket from the flushing plug was removed.
Reinstall the cartridge. Turn the stop unit. If the unit continues to leak, contact Hansgrohe
Customer Service for a replacement cartridge.
4
stop unit
Solaris oval escutcheon only: Install the white spacers on the carrier plate (a). Install two Duotec strips on the spacers (b).
Install the remaining two strips on the back of the escutcheon.
All other models: Install two Duotec strips directly on the carrier plate. Install the remaining two strips on the back of the escutcheon.
Install the carrier plate gasket and carrier plate with the carrier plate screws.
English
a
b
Press the escutcheon very firmly over the carrier plate, so that the strips of Duotec interlock, produc­ing a very firm hold.
Install the handle. Tighten the handle screw with a 3 mm Allen wrench. The handle screw must engage the slot milled into the brass on the cartridge.
Set the high temperature limit stop (optional) -- see page 8.
Justify the handle -- see page 6.
5
English
Modify the cartridge
The current ThermoBalance I cartridge has both a locator tab and a positioning pin. (The positioning pin is located on the back of the cartridge, and is not visible in this picture.)
An older ThermoBalance I/ThermoPlus rough does not have a notch for the locator tab.
Carefully file off the locator tab before install­ing a current cartridge into an old rough.
Justify the handle
Tools required: Thermometer 3 mm Allen wrench (included with trim kit)
locator tab
Turn the valve on. Place the thermometer in the water stream.
Turn the temperature control knob until the water coming out measures 100° on the thermometer.
Turn the water off using the lever part of the handle.
Use a 3 mm Allen wrench to loosen the set screw on the bottom of the handle. Remove the handle from the valve (1).
Hold the lever in one hand. With the other hand, turn the temperature control knob approximately ½ turn clockwise (2a). Then, without pressing inward on it, turn it counter-clockwise until it is positioned vertically and hits the safety stop (2b).
Reinstall the handle and tighten the set screw (3).