Valve trim Shower set
only trim
C Lever 06061XX0 06079XX0
C Scroll 06062XX0 06080XX0
C Cross 06063XX0 06081XX0
Solaris² E 04146XX0 04149XX0
Allegro² E 04152XX0 04155XX0
Metro² E 04158XX0 04161XX0
Metris S 31316XX1 31323XX1
Focus S 31735XX1 31771XX1
Talis S 32316XX1 32323XX1
Solaris E 06635XX0 06641XX0
Stratos E 06579XX0 06585XX0
Metro E 06655XX0 06661XX0
06061XX006062XX006063XX0
These trim kits are for use with
the following rough valves:
ThermoBalance I rough valves
06621000, 06622000
ThermoBalance I rough valves with
bypass 06300000, 06301000
04146XX004152XX004158XX0
31316XX131735XX132316XX1
06635XX006579XX006655XX0
2
Technical Information
Recommended pressure 45 - 72 psi
Max hot water temperature 165 F*
Recommended incoming hot water temp. 120° - 140° F*
With rough valve 06621000, 06622000
Nominal capacity @ 45 PSI 9.5 gpm
Nominal capacity @ 60 PSI 11.5 gpm
With rough valve with bypass 06300000, 06301000
Nominal capacity @ 45 PSI 6.0 gpm
Nominal capacity @ 60 PSI 6.5 gpm
Safety stop 100° F
Maximum output temperature 110° F**
1/2” NPT Connections
Listed by UL
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
**The high temperature limit stop may be reset to comply with local plumbing codes. See page 8.
Installation
Turn the water off at the main, or at the stops, before beginning.
Cut the installation box (i-box) so that it extends
1/16” outside the finished wall.
English
Seal the wall around the i-box with
waterproof sealant.
Failure to seal the wall can lead to possible
water damage.
Remove the label. Cut the support arms that
connect the flushing plug to the installation
box. Remove the flushing plug. Do not dis-
card the screws.
Be sure that the blue sealing
gasket is removed as well.
Failure to remove the gasket
can result in possible damage
to the cartridge and possible
water damage.
3
English
Insert the cartridge in the rough. The locator tab
on the cartridge goes straight into the notch in the
rough*.
notch
positioning
pin hole
*Note: The earlier version of
the ThermoBalance I rough does
locator tab
not have the notch for the locator
tab. See page 6 for cartridge
modification instructions.
The positioning pin on the back of the cartridge goes straight into the hole in the rough.
Use the reserved screws to connect the cartridge retainer plate to the rough. Tighten the
screws evenly, using a manual screwdriver, in a cross-wise pattern. Do not overtighten
the screws.
Perform the following test to check for damage to the ceramic
plates inside the stop unit.
Failure to correctly perform this test can result in possible water
damage.
Turn on the water supplies. Grasp the stop unit
portion of the cartridge and turn it.
If there is a leak around the cartridge, turn the
supplies off, and remove the cartridge. Confirm
that the sealing gasket from the flushing plug was
removed.
Reinstall the cartridge. Turn the stop unit.
If the unit continues to leak, contact Hansgrohe
Customer Service for a replacement cartridge.
4
stop unit
Solaris oval escutcheon only: Install the
white spacers on the carrier plate (a). Install two
Duotec strips on the spacers (b).
Install the remaining two strips on the back of the
escutcheon.
All other models: Install two Duotec strips
directly on the carrier plate. Install the remaining
two strips on the back of the escutcheon.
Install the carrier plate gasket and carrier plate
with the carrier plate screws.
English
a
b
Press the escutcheon very firmly over the carrier
plate, so that the strips of Duotec interlock, producing a very firm hold.
Install the handle. Tighten the handle screw
with a 3 mm Allen wrench. The handle screw
must engage the slot milled into the brass on the
cartridge.
Set the high temperature limit stop (optional) -- see
page 8.
Justify the handle -- see page 6.
5
English
Modify the cartridge
The current ThermoBalance I cartridge has
both a locator tab and a positioning pin. (The
positioning pin is located on the back of the
cartridge, and is not visible in this picture.)
An older ThermoBalance I/ThermoPlus rough
does not have a notch for the locator tab.
Carefully file off the locator tab before installing a current cartridge into an old rough.
Justify the handle
Tools required:
Thermometer
3 mm Allen wrench (included with trim kit)
locator tab
Turn the valve on. Place the thermometer in the
water stream.
Turn the temperature control knob until the water
coming out measures 100° on the thermometer.
Turn the water off using the lever part of the
handle.
Use a 3 mm Allen wrench to loosen the set screw
on the bottom of the handle. Remove the handle
from the valve (1).
Hold the lever in one hand. With the other hand,
turn the temperature control knob approximately
½ turn clockwise (2a). Then, without pressing
inward on it, turn it counter-clockwise until it is
positioned vertically and hits the safety stop (2b).
Reinstall the handle and tighten the set screw (3).
6
2
a
b