Hansen HGV1, HGV1H, HGV2, H7771H, H965 Specifications, Applications, Service Instructions & Parts

...
Bulletin G409d
JAN 2013
Specifications, Applications,
Service Instructions & Parts
GAUGE, PURGE, AND
TRANSDUCER VALVES
1/4" – 1/2" (7mm – 13mm) MPT or FPT Globe & Angle
HGV1: Long Neck
H9490: Transducer Valve
INTRODUCTION
These specially designed refrigerant gauge, purge, and transducer valves feature tough, forged steel bodies, compact size, and polished stainless steel stems. The patented O-ring plus packing dual seal design and polished stainless steel stem virtually eliminates stem seal leakage. Safety stems are designed to be non­removable from the body to avoid dangerous stem "blow out".
APPLICATION
These Hansen-made valves are suitable for ammonia, R22, R134a, CO2 and other approved refrigerants. They are available with seal caps, bar handles or bare stems. They are often used to isolate pressure gauges on regulators and safety relief valves. These valves may also be used for pumpout and purging. They are not recommended for oil drain because the port is too small for viscous oil. The Long Neck® valves provide additional length for insulation and pressure gauge turning clearance. The transducer valve accommodates calibration or device replacement without system pumpdown.
MATERIAL SPECIFICATIONS
Body: Forged steel, ASTM A105, zinc plated
(H9490 not plated)
Stem: Stainless steel, polished, ¼" square flats
Stem Packing: Graphite composite plus
neoprene O-ring
Packing Nut: Steel, zinc plated
Seal Cap: Glass filled polymer
Seal Cap O-ring: Neoprene
Bar Handle: Steel, zinc plated
Safe Working Pressure: 400 psig (28 bar) SWP
600 psig (41 bar) available upon request
Operating Temperature: -60°F to 240°F
(-50°C to +115°C)
KEY FEATURES
OPTIONAL BAR HANDLE
SEAL CAP
NON-REMOVABLE SAFETY STEM
FORGED STEEL BODY
POLISHED STAINLESS STEEL STEM
O-RING PLUS PACKING STEM SEAL
ADDITIONAL FEATURES
Globe and angle valve available
Heavy duty forged steel body
Long Neck gauge valve available
Unique Transducer / Gauge valve
Interchangeable seal caps and bar handles
LONG NECK AVAILABLE
INSTALLATION DIMENSIONS (inches)
MPT X FPT, ANGLEMPT x FPT, LONG NECK
FPT X FPT, ANGLEFPT X FPT, GLOBE
SIZE (mm)
1/4"
3/8"
1/2"
* THE B DIMENSI ON FOR HGV1, HGV1H, & HGV2 IS 3 .25" (83MM)
A A' B C E F G H H' J
2.09
2.57
1.11*
1.2 6
1.0 0
0.59
(7)
(10)
(13)
(53)
2.94 (75)
2.94 (75)
(65)
3.57 (91)
3.57 (91)
(28)
1.4 4 (37)
1.4 4 (37)
(32)
1.8 8 (48)
1.8 8 (48)
(25)
1.6 3 (41)
1.6 3 (41)
2.28
(15)
(58)
0.72
3.22
(18)
(82)
0.72 –
(18)
2.22 (56)
3.07 (78)
TRANSDUCER VALVE
2.71 (69)
3.70 (94)
0.47 (12)
0.59 (15)
ORDERING INFORMATION
DESCRIPTION SE AL
1/4" MPT x FPT, Angle, Long Neck HGV1* HGV1H HGV2 1/4" MPT x FPT, Angle H7771* H7771H H965 1/4" FPT x FPT, Angle H7772 H7772H H967 1/4" FPT x FPT, Globe H957C H957H H957 1/4" MPT x FPT x FPT, Transducer Valve H9490 – 3/8" MPT x FPT, Angle H7773 H7773H – 3/8" FPT x FPT, Angle H7774 H7774H – 3/8" FPT x FPT, Globe H958C H958H – 1/2" MPT x 3/8" FPT, Angle H7777 – 1/2" MPT x 1/4" FPT Angle H7778
LONG NECK VALVES PROVIDE ADDITIONAL LENGTH FOR INSULATION AND
PRESSURE GAUGE TURNING CLEARANCE.
* HGV1 AND H7771, AVAIL ABLE A S WELDE D INLE T VERS IONS, HGV1W AND
H7771W PAINTED BODY.
CAP
TO ORDER: Specify Catalog Number.
BAR
HANDLE
BARE STEM
SERVICE AND MAINTENANCE
Hansen gauge valves require practically no service or maintenance due to the combination of polished stainless steel stem and reliable O-ring stem seal plus graphite composite packing. However, if tightening is ever needed, use a 3/8" open end wrench or an 8" adjustable wrench. Extrusion of some black graphite packing material along the stem is normal.
If the O-ring or the adjustable packing ever needs replacement as evidenced by refrigerant or oil leakage at the stem, isolate valve from the system and evacuate to zero pressure in accordance with appropriate practices.
Seal caps [1/4" (P/N 50–1071), 3/8"–1/2" (P/N 50–1036)] or bar handles [1/4" (P/N 50–1069), 3/8" (P/N 50–1075)] can be easily retro-fitted to valves in the field. All bodies have seal cap threads; simply screw seal cap with O-ring onto these threads. Bar handle kit comes with pin partially installed in handle Place handle on stem and turn clockwise to close valve. Begin to push pin through handle and valve stem using pliers, then tap with hammer to finish.
1/4" Transducer Valve
The H9490 Transducer Valve can be installed wherever
pressure monitoring is desired. Turn stem all the way
in (clockwise) and seat to isolate pressure from both gauge and transducer por ts. Turn stem all the way out (counter-clockwise) and seat to isolate pressure from
the gauge port. With stem in middle position, both
ports are active.
G409d JAN 2013
CAUTION
Hansen valves are for refrigeration systems only. Read these instructions completely before selecting, using, or servicing these valves. Only knowledgeable, trained refrigeration technicians should install, operate, or service these valves. Stated temperature and pressure limits should not be exceeded. Bonnets should not be removed from valves unless the system has been evacuated to zero pressure. See also Safety Precautions in the current List Price Schedule and the Safety Precautions Sheet supplied with the product.
WARRANTY
Hansen valves are guaranteed against defective materials or workmanship for one year F.O.B. our factory. No consequential damages or field labor is included.
Hansen Technologies Corporation 400 Quadrangle Drive, Suite F Bolingbrook, Illinois 60440 USA Tel: 630.325.1565 Fax: 630.325.1572 Toll: 866.4HANSEN Email: sales@hantech.com Web: www.hantech.com
USA ∙ Asia ∙ Europe ∙ India ∙ LatinAmerica ∙ MiddleEast
© 2013 Hansen Technologies Corporation
2
Loading...