Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information
for the correct operation of the meter. Please read it carefully before using the meter.
If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com.
These instruments are in compliance with the directives.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and exam­ine it carefully to make sure that no damage has occurred during shipment. If there is any damage, notify your Dealer.
Each instrument is supplied complete with battery and in­structions.
Note: Conserve all packing material until the instrument has
been observed to function correctly. Any defective item must be returned in its original packing.
FUNCTIONAL DESCRIPTION SPECIFICATIONS
HI 99550-00 HI 99550-01 Range -10 to 300 °C 14 to 572 °F Resolution 1 °C 1 °F Accuracy ±2% of reading or
±2°C ±3°F
Typical EMC Deviation
±2 °C ±4 °F
Emissivity 0.95 Wave Length 6 to 14 µm Typical Response Time 1 second Optic Coefficient 3 : 1
(ratio of distance to diameter of target diameter);
minimum distance 30 mm (1.2’’)
Battery Type 1 x 9V Battery Life approx. 150 hours of continuous use Environement 0 to 50 °C (32 to 122 °F);
RH max 95%
Dimensions 143 x 80 x 38 mm (5.6 x 3.2 x 1.5”) Weight 320 g (11.3 oz.)
WARRANTY
HI 99550 is warranted for two years against defects in workman­ship and materials when used for its intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge.
If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner.
Hanna Instruments reserves the right to modify the design, construction
and appearance of its products without advance notice.
GENERAL DESCRIPTION
Infrared radiation emitted from an object depends on its tem­perature. The HI 99550 infrared thermometer employs this tech- nology to measure the surface temperature. Infrared measure­ments are extremely practical with an instantaneous response time. The non-intrusive nature of the measurements can trans­late itself into substantial savings in industries where products are sealed or pre-wrapped. This type of non-intrusive measure­ment is also useful when the surface temperature is high, for difficult-to-reach places or due to hygiene requirements. In order to measure the temperature, simply point to the product or the spot and hold down the measurement key. The measured value will be immediately displayed on the LCD. HI 99550 is designed with a wrist-strap and ergonomic shape for greater ease of use. The fast response time and the HOLD function make this infrared meter particularly attractive for repetitive tests in the factory or on the production line. Two models are available for measurement in degree Celsius or Fahreneit (HI 99550-00 and HI 99550-01).
1. Infrared sensor
2. Liquid Crystal Display (LCD)
3. ON/OFF and hold button
4. Wrist-strap
ACCESSORIES
HI 710004 Soft carrying case HI 710007 Blue shockproof rubber boot HI 710008 Orange shockproof rubber boot HI 721316 Rugged carrying case HI 731318 Wiping tissue (4 pcs) HI 740016 Battery cover HI 740123 Wrist-strap
IST99550R3 07/05
OPERATIONAL GUIDE
Temperature Measurement
To obtain the temperature of an object, simply aim the sen­sor in the direction of the object. Keep the “ON/OFF” button pressed for a few sec­onds until the reading stabilizes.
The instrument will continue reading the temperature, while the “ON/OFF” button is pressed. When released, the instrument freezes the read­ing for a few seconds and then switches off automati­cally.
Reading Distance
The distance between the sensor and the object is an important factor in the infrared measurement.
The relation between “distance/object area” of the instrument is 3:1. This means that the diameter of the measured area is one third of the distance between the sensor and the object.
For example, if the sensor is 15 cm away from the object, the instrument measures the temperature of an area with a 5 cm diameter.
To measure substances that have a polished surface and are very reflective, the emissivity needs to be compensated.
It is advisable to cover the object with black paint or black adhesive tape to compensate for the reflectivity.
Precaution
To avoid damage, do not hold the sensor too close to a heat source, for a long period.
Sensor Cleaning
To maintain the instrument’s accuracy, it is important that the sensor lens is kept clean.
To clean the sensor gently pass a humid and non-abrasive cloth (HI 731318) on the lens.
Low Battery
A blinking “V” on the display indicates a low battery level.
It is recommended to replace the battery soon.
BATTERY REPLACEMENT
Battery replacement must only take place in a safe area and using a 9V alkaline battery.
Simply slide off the battery cover on the back of the meter, detach the battery from the terminals and attach a new 9V battery, while paying attention to the correct polarity.
CE DECLARATION OF CONFORMITY
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used.
Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance.
To avoid damages or burns, do not perform any measurement in microwave ovens.
SALES & TECHNICAL SERVICE CONTACTS
Australia
Tel. (03) 9769.0666 • Fax (03) 9769.0699
China
Tel. (10) 88570068 • Fax (10) 88570060
Egypt
Tel. & Fax (02) 2758.683
Germany
Tel. (07851) 9129-0 • Fax (07851) 9129-99
Greece
Tel. (210) 823.5192 • Fax (210) 884.0210
Indonesia
Tel. (21) 4584.2941 • Fax (21) 4584.2942
Japan
Tel. (03) 3258.9565 • Fax (03) 3258.9567
Korea
Tel. (02) 2278.5147 • Fax (02) 2264.1729
Malaysia
Tel. (603) 5638.9940 • Fax (603) 5638.9829
Singapore
Tel. 6296.7118 • Fax 6291.6906
South Africa
Tel. (011) 615.6076 • Fax (011) 615.8582
Taiwan
Tel. 886.2.2739.3014 • Fax
886.2.2739.2983
Thailand
Tel. 66.2619.0708 • Fax 66.2619.0061
United Kingdom
Tel. (01525) 850.855 • Fax (01525) 853.668
USA
Tel. (401) 765.7500 • Fax (401) 765.7575
Emissivity
The instrument measures the temperature of objects with an emissivity of 0.95, which is the characteristic of most sub­stances such as organic material, water, plastic, fabrics, etc.
Replace the battery cover.