Instruction Manual
HI 945005 - HI 945007
Microprocessor-based
K-Thermocouple
Thermometers
http://www.hannainst.com
Dear Customer, Thank you for choosing a Hanna
Instruments Product. Please read this instruction
manual carefully before using the instrument. This manual will pro­vide you with all the necessary information for the correct use of the instrument, as well as a pre­cise idea of its versatility in a wide range of applications.
These instruments are in com­pliance with the directives.
TABLE OF CONTENTS
Preliminary Examination..............3
General Description......................3
Functional Description .................5
Specifications...............................6
Operational Guide........................7
Battery Replacement.................10
Accessories.................................11
CE Declaration of Conformity....15
Warranty.....................................15
Hanna Instruments reserves the right to modify the design, construction and appearance of its products without ad­vance notice.
2
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. If noticeable damage is evident, notify your Dealer.
Each thermometer comes sup­plied with a 9V battery and in­struction manual.
Note: Save all packing material until you are sure that the instru­ment functions correctly. All de­fective items must be returned in the original packing together with the supplied accessories.
GENERAL DESCRIPTION
HI 945005 and HI 945007 are
microprocessor-based thermom­eters designed for food industry.
Temperature measurements are performed by using interchange­able K-type thermocouple probes.
3
Standard features include:
• Interchangeable probes
(Hanna manufactures several K-type thermocouple probes for different applications; see Acccessories section)
• Clear Liquid Crystal Display
• Possibility of switching be­tween the Centigrade and the Fahrenheit scale
• HOLD function that freezes the reading on the display (for HI 945007 only)
• Low battery detection.
All these functions are easily ac­cessible through the keypad.
Self-explanatory symbols are used to remind the user of the operating mode or condition.
HI 945005 and HI945007 are ac­curately pre-calibrated at the fac­tory.
It is generally recommended to have the thermometers recali­brated at least once a year.
For an accurate annual recali­bration, contact your nearest Hanna Service Center.
4
FUNCTIONAL DESCRIPTION
5
SPECIFICATIONS
Low Range -50.0 to 150.0°C
-58.0 to 199.9°F / 200 to 302°F
High Range -50 to 950°C
-58 to 1742°F
Resolution 0.1°C (-50.0 to 150.0°C)
1°C (-50 to 950°C)
0.2°F (-58.0 to 199.9°F) 1°F (-58 to 1742°F)
Accuracy ±0.4°C (low range °C)
±0.8°F (low range °F)
±0.2% f.s. (high range °C/°F)
Typical EMC Deviation ±3°C
±6°F
Probe K-thermocouple
(see pag. 10-13)
Auto-off after 45 minutes, if activated Battery type 1 x 9V alkaline Battery life approx. 500 hours
of continuous use
Environment 0 to 50°C (32 to 122°F);
Dimensions 60 x 30 x 168 mm
Weight (meter only) 165 g (5.84 oz.)
95% RH non-condensing
(2.4 x 1.2 x 6.6'')
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used.
Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance.
To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24VAC or 60 VDC.
To avoid damages or burns, do not perform any measurement in microwave ovens.
6
OPERATIONAL GUIDE
INITIAL PREPARATION
Remove the battery cover on the rear of your thermometer, unwrap the battery and connect it to the clip. Insert the battery in its com­partment and replace the cover. (see "Battery Replacement" at pag.9)
To switch the meter on, press the ON/OFF key.
Your thermom­eter will carry out a self diagnostic test. The LCD shows all the seg­ments at once.
After the test, the thermometer will switch to the measurement mode.
If a temperature probe is plugged in, the unit will display the tem­perature. If the probe is not plugged in, the display will show "Er".
To switch the meter off, press the ON/OFF key twice.
7
MEASURING SCALE (°C/°F)
When the meter is turned on, it automatically defaults to the °C scale. Measurements can be per­formed on either the Centigrade or the Fahrenheit scale.
To change the scale, press the °C/°F key once.
MEASUREMENT RESOLUTION
When switched on, the meters de­fault to 1 degree resolution.
Press the ON/OFF key again to change the resolution to
0.1°C (or 0.2°F).
HOLD MODE (for HI 945007 only)
The reading hold function is acti­vated by the HOLD key.
The temperature is frozen on the display until the HOLD button is pressed a second time.
The blinking symbol "M" appears on the display when HOLD is acti­vated.
Press HOLD again to return to the normal operational mode.
8
LOW BATTERY DETECTION
When the battery is low the user is prompted by the appearance of the word "Eb" to substitute the bat­tery.
AUTO-SHUT OFF
To save battery life, the meter will switch off after 45 minutes.
The switch located in the bat­tery compartment enables this feature. Remove the battery cover and slide the switch to the right. The thermometer's auto-off feature will be disabled. If the switch is to the left, the meter will shut off automatically.
9
BATTERY REPLACEMENT
When the bat­tery is low the user is warned by the word "Eb" on the instrument's display.
Replace immediately the battery.
Battery replacement must only take place in a non hazardous area us­ing a 9V battery.
Remove the battery compartment cover on the rear of the meter and replace the 9V battery with a new one. Make sure the battery con­tact is tight before replacing the cover.
The meter will turn on automati­cally when a new battery is con­nected. You can turn it off by press­ing the ON/OFF key.
10
ACCESSORIES
K-Type Thermocouple Probes with detachable handle & mini-connec­tor (to be plugged into HI 766HD
probe handle):
HI 766PA Roller surface probe, max
320°C/600°F
HI 766PB Surface probe, max 650°C/
1200°F
HI 766PC Penetration probe, max
900°C/1650°F
155mm
6.1"
3mm
0.12"
HI 766PD Air probe, max 300°C/570°F
250mm
9.8"
3mm
0.12"
11
HI 766PE1 General use probe, max
900°C/1650°F
155mm
6.1"
3mm
0.12"
HI 766PE2 General use probe, max
900°C/1650°F
200mm
7.8"
5mm
0.20"
HI 766HD Rugged thermocouple probe
handle with 1 m (3.3' ) cable fitted with a mini-connector
with integral handle, 1 m cable & mini-connector:
HI 766A Roller surface probe, max
320°C/600°F
HI 766B Surface probe, max 650°C/
1200°F
12
HI 766B1 90° surface probe, max 450°C (840°F)
30mm
300mm
11.8"
1.2"
HI 766B2 Surface probe, max 900°C (1650°F)
8mm
0.3"
130mm
5.1"
HI 766B3 Small surface probe with
insulated shaft, max 200°C/ 390°F
5mm
0.2"
130mm
5.1"
HI 766C Penetration probe, max 900°C/
1650°F
HI 766D Air probe, max 300°C/570°F
HI 766E1 General use probe, max
900°C/1650°F
13
HI 766E2 General use probe, max
900°C/1650°F
HI 766F High temperature wire probe
without handle, max 1100°C/2000°F
255mm
10"
1.5mm
0.06"
HI 766F1 Flexible probe without
handle, max 480°C/900°F
2mm
0.08"
3.3’
1m
HI 766TV1 Pipe clamp probe, max
200°C/390°F
35mm
Max.
1.4"
14
CE DECLARATION
OF CONFORMITY
WARRANTY
All Hanna Instruments meters are warranted for two years against defects in workman-
ship and materials when used for their in­tended purpose and maintained according to instructions. The probes are warranted for
a period of six months.
This warranty is limited to repair or replace­ment free of charge. Damages due to acci­dent, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If un­der warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Cus­tomer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly pack­aged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner.
15
07/01
http://www.hannainst.com