manual carefully before using the
instrument. This manual will provide you with all the necessary
information for the correct use of
the instrument, as well as a precise idea of its versatility in a
wide range of applications.
These instruments are in compliance with the directives.
TABLE OF CONTENTS
Preliminary Examination..............3
General Description......................3
Functional Description .................5
Specifications...............................6
Operational Guide........................7
Battery Replacement.................10
Accessories.................................11
CE Declaration of Conformity....15
Warranty.....................................15
Hanna Instruments reserves the right
to modify the design, construction and
appearance of its products without advance notice.
2
PRELIMINARY EXAMINATION
Remove the instrument from the
packing material and examine it
carefully to make sure that no
damage has occurred during
shipment. If noticeable damage
is evident, notify your Dealer.
Each thermometer comes supplied with a 9V battery and instruction manual.
Note: Save all packing material
until you are sure that the instrument functions correctly. All defective items must be returned
in the original packing together
with the supplied accessories.
GENERAL DESCRIPTION
HI 945005 and HI 945007 are
microprocessor-based thermometers designed for food industry.
Temperature measurements are
performed by using interchangeable K-type thermocouple probes.
The non-linearity of the temperature probe is linearized by the
built-in microprocessor, in order
to achieve high degree accuracy
and resolution. It also permits
accurate compensation for drifts
in the reference junction.
3
Standard features include:
• Interchangeable probes
(Hanna manufactures several
K-type thermocouple probes
for different applications; see
Acccessories section)
• Clear Liquid Crystal Display
• Possibility of switching between the Centigrade and the
Fahrenheit scale
• HOLD function that freezes
the reading on the display (for
HI 945007 only)
• Low battery detection.
All these functions are easily accessible through the keypad.
Self-explanatory symbols are
used to remind the user of the
operating mode or condition.
HI 945005 and HI945007 are accurately pre-calibrated at the factory.
It is generally recommended to
have the thermometers recalibrated at least once a year.
For an accurate annual recalibration, contact your nearest
Hanna Service Center.
4
FUNCTIONAL DESCRIPTION
5
SPECIFICATIONS
Low Range-50.0 to 150.0°C
-58.0 to 199.9°F / 200 to 302°F
High Range-50 to 950°C
-58 to 1742°F
Resolution0.1°C (-50.0 to 150.0°C)
1°C (-50 to 950°C)
0.2°F (-58.0 to 199.9°F)
1°F (-58 to 1742°F)
Accuracy±0.4°C (low range °C)
±0.8°F (low range °F)
±0.2% f.s. (high range °C/°F)
Typical EMC Deviation±3°C
±6°F
ProbeK-thermocouple
(see pag. 10-13)
Auto-offafter 45 minutes, if activated
Battery type1 x 9V alkaline
Battery lifeapprox. 500 hours
of continuous use
Environment0 to 50°C (32 to 122°F);
Dimensions60 x 30 x 168 mm
Weight (meter only)165 g (5.84 oz.)
95% RH non-condensing
(2.4 x 1.2 x 6.6'')
Recommendations for Users
Before using these products, make sure that they are entirely
suitable for the environment in which they are used.
Operation of these instruments in residential area could cause
unacceptable interferences to radio and TV equipments, requiring
the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment
may degrade the instruments' EMC performance.
To avoid electrical shock, do not use these instruments when
voltages at the measurement surface exceed 24VAC or 60 VDC.
To avoid damages or burns, do not perform any measurement in
microwave ovens.
6
OPERATIONAL GUIDE
INITIAL PREPARATION
Remove the battery cover on the
rear of your thermometer, unwrap
the battery and connect it to the
clip. Insert the battery in its compartment and replace the cover.
(see "Battery Replacement" at
pag.9)
To switch the
meter on, press
the ON/OFF key.
Your thermometer will carry out
a self diagnostic
test. The LCD
shows all the segments at once.
After the test, the thermometer will
switch to the measurement mode.
If a temperature probe is plugged
in, the unit will display the temperature.
If the probe is not
plugged in, the
display will show
"Er".
To switch the
meter off, press
the ON/OFF key
twice.
7
MEASURING SCALE (°C/°F)
When the meter is turned on, it
automatically defaults to the °C
scale. Measurements can be performed on either the Centigrade or
the Fahrenheit scale.
To change the scale,
press the °C/°F key
once.
MEASUREMENT RESOLUTION
When switched on, the meters default to 1 degree resolution.
Press the ON/OFF
key again to change
the resolution to
0.1°C (or 0.2°F).
HOLD MODE (for HI 945007 only)
The reading hold function is activated by the HOLD key.
The temperature is frozen on the
display until the HOLD button is
pressed a second time.
The blinking symbol "M" appears
on the display when HOLD is activated.
Press HOLD again to
return to the normal
operational mode.
8
LOW BATTERY DETECTION
When the battery
is low the user is
prompted by the
appearance of
the word "Eb" to
substitute the battery.
AUTO-SHUT OFF
To save battery life, the meter
will switch off after 45 minutes.
The switch located in the battery compartment enables this
feature. Remove the battery
cover and slide the switch to
the right. The thermometer's
auto-off feature will be disabled.
If the switch is to the left, the
meter will shut off automatically.
9
BATTERY REPLACEMENT
When the battery is low the
user is warned
by the word
"Eb" on the
instrument's display.
Replace immediately the battery.
Battery replacement must only take
place in a non hazardous area using a 9V battery.
Remove the battery compartment
cover on the rear of the meter and
replace the 9V battery with a new
one. Make sure the battery contact is tight before replacing the
cover.
The meter will turn on automatically when a new battery is connected. You can turn it off by pressing the ON/OFF key.
10
ACCESSORIES
K-Type Thermocouple Probes with
detachable handle & mini-connector (to be plugged into HI 766HD
probe handle):
HI 766PA Roller surface probe, max
320°C/600°F
HI 766PB Surface probe, max 650°C/
1200°F
HI 766PC Penetration probe, max
900°C/1650°F
155mm
6.1"
3mm
0.12"
HI 766PD Air probe, max 300°C/570°F
250mm
9.8"
3mm
0.12"
11
HI 766PE1 General use probe, max
900°C/1650°F
155mm
6.1"
3mm
0.12"
HI 766PE2 General use probe, max
900°C/1650°F
200mm
7.8"
5mm
0.20"
HI 766HD Rugged thermocouple probe
handle with 1 m (3.3' ) cable
fitted with a mini-connector
with integral handle, 1 m cable
& mini-connector:
HI 766A Roller surface probe, max
320°C/600°F
HI 766B Surface probe, max 650°C/
1200°F
12
HI 766B1 90° surface probe, max 450°C
(840°F)
30mm
300mm
11.8"
1.2"
HI 766B2 Surface probe, max 900°C
(1650°F)
8mm
0.3"
130mm
5.1"
HI 766B3 Small surface probe with
insulated shaft, max 200°C/
390°F
5mm
0.2"
130mm
5.1"
HI 766C Penetration probe, max 900°C/
1650°F
HI 766D Air probe, max 300°C/570°F
HI 766E1 General use probe, max
900°C/1650°F
13
HI 766E2 General use probe, max
900°C/1650°F
HI 766F High temperature wire probe
without handle, max
1100°C/2000°F
255mm
10"
1.5mm
0.06"
HI 766F1 Flexible probe without
handle, max 480°C/900°F
2mm
0.08"
3.3’
1m
HI 766TV1 Pipe clamp probe, max
200°C/390°F
35mm
Max.
1.4"
14
CE DECLARATION
OF CONFORMITY
WARRANTY
All Hanna Instruments meters are warranted
for two years against defects in workman-
ship and materials when used for their intended purpose and maintained according to
instructions. The probes are warranted for
a period of six months.
This warranty is limited to repair or replacement free of charge. Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact the dealer from
whom you purchased the instrument. If under warranty, report the model number, date
of purchase, serial number and the nature of
the failure. If the repair is not covered by the
warranty, you will be notified of the charges
incurred. If the instrument is to be returned
to Hanna Instruments, first obtain a Returned
Goods Authorization Number from the Customer Service department and then send it
with shipment costs prepaid. When shipping
any instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return
the enclosed warranty card within 14 days
from the date of purchase.
All rights are reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
15
07/01
http://www.hannainst.com
16
MANK94R1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.