Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the instrument.
This manual will provide you with the necessary information for correct
use of the instrument, as well as a more precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at tech@hannainst.com.
These instruments are in compliance with the directives.
WARRANTY
All Hanna Instruments meters are warranted for two years against defects in
workmanship and materials when used for their intended purpose and maintained
according to instructions. Theprobes are warranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accidents, misuse, tampering or lack of prescribed maintenance are
not covered.
If service is required, contact the dealer from whom you purchased the instrument. If
under warranty, report the model number, date of purchase, serial number and the
nature of the failure.
First obtain a Returned Goods Authorization number from the Customer Service department, then return the instrument with the Authorization number included along with
shipment costs prepaid.
If the repair is not covered by the warranty, you will be notified of the charges.
When shipping any instrument, make sure it is properly packaged for complete
Remove the instrument from the packing material and examine it to
make sure that no damage has occurred during shipping. If there is
any damage, notify your dealer or the nearest Hanna Customer
Service Center.
Each meter is supplied complete with:
• 3 x 1.5V AA alkaline batteries
• Instruction manual
Note: Save all packing material until you are sure that the
instrument functions correctly. All defective items must be
returned in the original packing with the supplied accessories.
GENERAL DESCRIPTION
These instruments are powerful and flexible K-type thermocouple
thermometers, which have been designed using the latest microprocessor technology to provide reliable and accurate high resolution
measurements in a wide temperature range.
Standard features include K-type thermocouple measurement, waterproof casing, HOLD function, °C/°F selection, auto-off capability,
remaining battery life indication, low battery detection, long battery
life and two-year warranty.
HI 93531 and HI 93532 model series are equipped with a dual-line
LCD for continuous monitoring and displaying of Low and High
temperature values, and CLR function.
HI 93532, HI 93532N and HI 93532R are two-channel thermom-
eters, ideal for monitoring two samples at once.
HI 93530N, HI 93531N, HI 93531R, HI 93532N and HI 93532R
offer additional features, such as calibration of meter and probe at
0°C, and backlit display.
Moreover, the HI 93531R and HI 93532R models are equipped
with a serial port interface, and provide average and relative
measurements.
All rights are reserved. Reproduction in whole or in part is prohibited without the
written consent of the copyright owner, Hanna Instruments.
Hanna Instruments reserves the right to modify the design, construction and
appearance of its products without advance notice.
32
Page 3
SPECIFICATIONS OF
HI 93530 & HI 93530N
SPECIFICATIONS
Range (*)-200.0 to 999.9°C / 1000 to 1371°C
-328.0 to 999.9°F / 1000 to 2500°F
Resolution0.1°C (-149.9 to 999.9°C)
0.2°C (-200.0 to -150.0°C) / 1°C (outside)
0.1°F (-24.9 to 999.9°F)
0.2°F (-249.9 to -25.0°F)
0.3°F (-328.0 to -250.0°F) / 1°F (outside)
Accuracy±0.5°C (-100.0 to 999.9°C) / ±1°C (outside)
(@20°C/68°F) ±1°F (-148.0 to 999.9°F) / ±1.5°F (outside)
excluding probe error
Typical EMC ±3°C / ±6°F
Deviation with HI 766 K-thermocouple probe
Battery3x1.5V AA (IEC LR6) batteries,
approx. 500 hours of continuous use (BL off)
Auto-offuser selectable: 60 min or disabled
Environment-10 to 60°C (14 to 140°F); RH 100%
Dimensions150 x 80 x 36 mm (5.9 x 3.1 x 1.4")
Weight235 g (8.3 oz.)
(*) Range may be limited by probe.
Main features:
HI 93530HI 93530N
Keyboard Functions:
• Use HI 766 K-thermocouple probes
• Display of temperature in degrees Celsius or Fahrenheit
• Extended range -200 to 1371°C or -328 to 2500°F
• HOLD function
• Remaining battery life indication / low battery detection
• Waterproof casing
• Auto-off capability
• Backlight feature (HI 93530N only)
• User calibration at 0°C (HI 93530N only)
ON/OFF : turn the meter ON and OFF
HOLD : freeze the reading on display
°C/°F : change reading unit (°C or °F)
BL (HI 93530N only) : toggle the backlight ON and OFF
CAL (HI 93530N only) : press and hold for about 5 seconds to
enter the Calibration mode (with reading within ±3°C
range); press to abort the Calibration mode
54
Page 4
SPECIFICATIONS OF
HI 93531 & HI 93531N
SPECIFICATIONS
Range (*)-200.0 to 999.9°C / 1000 to 1371°C
-328.0 to 999.9°F / 1000 to 2500°F
Resolution0.1°C (-149.9 to 999.9°C)
0.2°C (-200.0 to -150.0°C) / 1°C (outside)
0.1°F (-24.9 to 999.9°F)
0.2°F (-249.9 to -25.0°F)
0.3°F (-328.0 to -250.0°F) / 1°F (outside)
Accuracy±0.5°C (-100.0 to 999.9°C) / ±1°C (outside)
(@20°C/68°F) ±1°F (-148.0 to 999.9°F) / ±1.5°F (outside)
excluding probe error
Typical EMC ±3°C / ±6°F
Deviation with HI 766 K-thermocouple probe
Battery3x1.5V AA (IEC LR6) batteries,
approx. 500 hours of continuous use (BL off)
Auto-offuser selectable: 60 min or disabled
Environment-10 to 60°C (14 to 140°F); RH 100%
Dimensions150 x 80 x 36 mm (5.9 x 3.1 x 1.4")
Weight235 g (8.3 oz.)
(*) Range may be limited by probe.
Main features:
HI 93531HI 93531N
Keyboard Functions:
• Use HI 766 K-thermocouple probes
• Display of temperature in degrees Celsius or Fahrenheit
• Extended range -200 to 1371°C or -328 to 2500°F
• HOLD function
• HI & LO (Max & Min) temperature values displayed on the LCD
• Remaining battery life indication / low battery detection
• Waterproof casing
• Auto-off capability
• Backlight feature (HI 93531N only)
• User calibration at 0°C (HI 93531N only)
ON/OFF : turn the meter ON and OFF
HOLD : freeze the reading on display.
°C/°F : change reading unit (°C or °F)
CLR : clear the HI and LO values
BL (HI 93531N only) : toggle the backlight ON and OFF.
CAL (HI 93531N only) : press and hold for about 5 seconds to enter
the Calibration mode (with reading within ±3°C range); press
to abort the Calibration mode
76
Page 5
SPECIFICATIONS OF
HI 93532 & HI 93532N
SPECIFICATIONS
Range (*)-200.0 to 999.9°C / 1000 to 1371°C
-328.0 to 999.9°F / 1000 to 2500°F
Resolution0.1°C (-149.9 to 999.9°C)
0.2°C (-200.0 to -150.0°C) / 1°C (outside)
0.1°F (-24.9 to 999.9°F)
0.2°F (-249.9 to -25.0°F)
0.3°F (-328.0 to -250.0°F) / 1°F (outside)
Accuracy±0.5°C (-100.0 to 999.9°C) / ±1°C (outside)
(@20°C/68°F) ±1°F (-148.0 to 999.9°F) / ±1.5°F (outside)
excluding probe error
Typical EMC ±3°C / ±6°F
Deviation with HI 766 K-thermocouple probe
Battery3x1.5V AA (IEC LR6) batteries,
approx. 500 hours of continuous use (BL off)
Auto-offuser selectable: 60 min or disabled
Environment-10 to 60°C (14 to 140°F); RH 100%
Dimensions150 x 80 x 36 mm (5.9 x 3.1 x 1.4")
Weight235 g (8.3 oz.)
(*) Range may be limited by probe.
Main features:
HI 93532HI 93532N
Keyboard Functions:
• Two independent measurement channels, T1 and T2
• Use HI 766 K-thermocouple probes
• Display of temperature in degrees Celsius or Fahrenheit
• Extended range -200 to 1371°C or -328 to 2500°F
• HOLD function
• HI & LO (Max & Min) temperature values displayed on the LCD
• Remaining battery life indication / low battery detection
• Waterproof casing
• Auto-off capability
• Backlight feature (HI 93532N only)
• User calibration at 0°C (HI 93532N only)
ON/OFF : turn the meter ON and OFF
T1/T2 : select the reading channel (T1, T2 or T1-T2)
HOLD : freeze the reading on display
CLR : clear the HI and LO values
BL (HI 93532N only) : toggle the backlight ON and OFF.
CAL (HI 93532N only) : press and hold for about 5 seconds to enter
the Calibration mode (with reading within ±3°C); press to abort
the Calibration mode
98
Page 6
SPECIFICATIONS OF
HI 93531R & HI 93532R
SPECIFICATIONS
Range (*)-200.0 to 999.9°C / 1000 to 1371°C
-328.0 to 999.9°F / 1000 to 2500°F
Resolution0.1°C (-149.9 to 999.9°C)
0.2°C (-200.0 to -150.0°C) / 1°C (outside)
0.1°F (-24.9 to 999.9°F)
0.2°F (-249.9 to -25.0°F)
0.3°F (-328.0 to -250.0°F) / 1°F (outside)
Accuracy±0.5°C (-100.0 to 999.9°C) / ±1°C (outside)
(@20°C/68°F) ±1°F (-148.0 to 999.9°F) / ±1.5°F (outside)
excluding probe error
Typical EMC ±3°C / ±6°F
Deviation with HI 766 K-thermocouple probe
Battery3x1.5V AA (IEC LR6) batteries,
approx. 500 hours of continuous use (BL off)
Auto-offuser selectable: 8 min, 60 min or disabled
Serial Portunidirectional, 8-bit data, 1200 baud
Communication(see "Serial Communication" section)
Environment-10 to 60°C (14 to 140°F); RH 100%
Dimensions150 x 80 x 36 mm (5.9 x 3.1 x 1.4")
Weight235 g (8.3 oz.)
(*) Range may be limited by probe.
Main features:
• Two independent measurement channels (HI 93532R only)
• Use HI 766 K-thermocouple probes
• Display of temperature in degrees Celsius or Fahrenheit
• Extended range -200 to 1371°C or -328 to 2500°F
• Relative and average measurements
• HOLD function
• HI & LO (Max & Min) temperature values displayed on the LCD
• Remaining battery life indication / low battery detection
• Waterproof casing
• Auto-off capability
• Backlight feature
• User calibration at 0°C
• RS232 serial port communication
HI 93531RHI 93532R
Keyboard Functions:
ON/OFF : turn the meter ON and OFF
T1/T2 (HI 93532R only) : select reading channel (T1, T2 or T1-T2)
HOLD : freeze the reading on display
CLR : clear the HI and LO values
DISP : select Normal, Relative or Average mode.
ALT : enable the second function keys; the "ALT" tag turns on to
indicate that the second functions are enabled
Note: The ALT key can be released before pressing the second
function key for 1-hand operation.
ALT/ CAL : press and hold for about 5 seconds to enter the
Calibration mode (with reading within ±3°C range).
(ALT +) AOFF : set auto power off delay (8 or 60 min, or disabled).
(ALT +) °C/°F : change reading units (°C or °F).
(ALT +) MR : recall memorized value.
(ALT +) BL : toggle the backlight ON and OFF.
1110
Page 7
OPERATIONAL GUIDE
Note: When the reading goes over-range or the probe is removed,
the Hi and Lo values display dashes until cleared.
To switch the instrument ON, press the ON/OFF key.
The thermometer will carry out a self diagnostic test routine, the LCD
will show all segments for a few seconds (or as long as ON/OFF is
held), followed by the percentage indication of the remaining battery
life.
The thermometer then enters normal measurement mode.
If a temperature probe is plugged in, the meter displays the
measured temperature.
If no probe is plugged in, or if reading is
over-range, the display shows flashing dashes.
If a measurement is slightly over the range
of the meter specifications, the display flashes
the closest full-scale value.
To switch the meter OFF, press the ON/OFF key.
Note: The meters are provided with an acoustic signal feature activated
when buttons are pressed, which can be disabled using a switch
located in the battery compartment (see figure on page 12).
HOLD FUNCTION
The HOLD function is activated by pressing the HOLD key.
The measured temperature is held on the
display until HOLD is pressed again. The
"HOLD" tag blinks on the display while in
HOLD mode.
Note: Although the display is frozen, internally the meter continues
measuring and updating Hi/Lo values (not for HI 93530 and
HI 93530N).
CLEAR FUNCTION (not for HI 93530 and HI 93530N)
Upon pressing the CLR key, the High/Low values may be cleared at
any time during measurement and the current reading is assigned to
the highest and lowest temperature values for the displayed channel
only.
°C/°F SELECTION
Measurements can be displayed in either
degrees Celsius or Fahrenheit. The meter is
factory set to °C scale; to change the scale,
press the °C/°F key,
or set the °C/°F switch located in the battery compartment (HI 93532
and HI 93532N only, see figure on page 12).
AUTO SHUT-OFF
To save battery life, these meters are provided with an auto-off
feature, which switches the instrument off after 60 minutes of nonuse.
To disable this feature, all models (except HI 93531R & HI 93532R)
are provided with an internal switch located in the battery compartment (see figure on page 14).
HI 93531R and HI 93532R allow the user to disable the auto-off
feature through the front keyboard; press (ALT+) AOFF to enter the
mode, then set the desired option (auto-off after 8 or 60 minutes, or
disabled) with the ALT key; release all buttons, wait a few seconds
and the meter will return to normal measurement mode.
HIGH/LOW TEMPERATURES
(not for HI 93530 and HI 93530N)
The maximum and minimum temperatures
are continuously monitored and displayed
on the lower portion of the LCD.
1312
Page 8
BACKLIGHT FEATURE
(not for HI 93530, HI 93531 and HI 93532)
The backlight feature can be easily activated through the keyboard
by pressing the BL (or ALT+BL) key.
Note: The backlight automatically shuts off after approximately 1
minute with no buttons pressed.
BATTERY COMPARTMENT
See "Battery replacement" section for back cover removal/installation.
DISP FUNCTION (HI 93531R and HI 93532R)
These models are also provided with the DISP function, which allows
the user to select the information to be displayed.
• While in T1 (or T2, HI 93532R only), pressing DISP switches the
display between normal, relative and average measurement modes.
In the normal mode, the main body of the LCD shows the current
temperature while the lower portion displays the Hi/Lo limits for
that channel.
When the meter enters relative mode, the "REL" tag lights up
and the current temperature for that channel is set as the
reference temperature. Pressing CLR will also set the reference to
the current temperature.
In relative mode, the main body of the LCD shows the difference
from the reference temperature. The lower portion displays the
current temperature for the selected channel.
When average mode is entered, the "AVG" tag lights up and the
current value is set as the new beginning value. The average can
be reset by pressing CLR while in the average mode.
In average mode, the main body of the LCD shows the average
temperature, while the lower portion displays the current temperature for the selected channel.
2-CHANNEL MODELS (HI 93532, HI 93532N & HI 93532R)
HI 93532, HI 93532N and HI 93532R models can monitor two
samples through two independent temperature channels (probes).
The display will show the actual, Hi and Lo values of the selected
channel (T1, T2 or T1-T2). The corresponding tags will light up to
inform the user.
To select the desired channel, use the T1/T2 key.
The average mode will calculate the average for a period of up to
24 hours. If a different mode is selected for that channel, the
average will no longer calculate and the value will be lost.
At the end of the 24 hour period, the "AVG" tag will blink to
indicate that sampling has stopped, and the displayed value is
the last average calculated.
If a probe is removed or over-range is reached while in average
mode, the display shows flashing dashes and blinking "AVG" tag.
1514
Page 9
The average value is lost and will not restore even if the condition
restores. To start the average cycle again, either press CLR or reenter the average mode.
• While in T1-T2 (HI 93532R only), pressing DISP will switch
between 4 displays:
Note: Pressing T1/T2 (HI 93532R only) to change the channel will not
alter the information chosen to be displayed for each channel
(DISP). For example, if T1 is in average mode, the average will
continue to be calculated even if the user press T1/T2 to see T2.
Note: Relative/average modes cannot be entered if dashes are shown
on the primary LCD.
Note: The auto-off time is disabled whenever a channel is set to
average mode.
BATTERY REPLACEMENT
When the battery level is below 5%, the battery symbol will blink on
the LCD to indicate a low battery condition.
If the battery level is low enough to cause erroneous readings, the
Battery Error Prevention System (BEPS) turns the meter off.
Immediately replace the batteries with new ones.
The batteries are accessed by separating the front and the back
halves of the meter: unscrew the 4 screws on the back of the meter
and carefully replace the three batteries located in the battery
compartment, while paying attention to their polarity. Reattach the
back making sure that the gasket is in place and tighten the screws
to ensure a watertight seal.
Battery replacement must only take place in a non-hazardous area
using 1.5V AA (IEC LR6) alkaline batteries.
SERIAL PORT COMMUNICATION
(HI 93531R & HI 93532R only)
HI 93531R and HI 93532R feature an RS232 output for transferring measurement data (once every second for HI 93531R and once
every 2 seconds for HI 93532R) to devices provided with RS232 input
(PC or printer).
The communication protocol has been designed to transmit to the
receiving unit all the displayed information.
The communication is unidirectional (meter to receiving unit only) and
the transmissions consist in a 32-character ASCII string, compatible
with our optional HI 92000 software.
The 32-character data string is structured as follows:
• byte 3measurement mode: Normal (blank), Relative (R),
Average (A), Average done (a)
• byte 4operating mode: Hold (H), Memory recall (M)
• byte 5blank character
• bytes 6-10measurement: reading (XXX.X or blank XXXX),
over-range (OVRG blank), no data (blank ----)
• byte 11temperature unit: C, F
• byte 12blank character
Secondary LCD, left portion
• bytes 13, 14 info description: low temperature (Lo), T1 (T1)
• byte 15blank character
• bytes 16-20measurement: reading (XXX.X or blank XXXX),
over-range (5 blanks), no data (blank ----)
• byte 21blank character
Secondary LCD, right portion
• bytes 22, 23 info description: high temperature (Hi), T2 (T2)
• byte 24blank character
• bytes 25-29measurement: reading (XXX.X or blank XXXX),
over-range (5 blanks), no data (blank ----)
• byte 30<CR>
• byte 31line feed
1716
Page 10
USER CALIBRATION
ACCESSORIES
(Not for HI 93530, HI 93531 and HI 93532 models)
The meters can be calibrated at 0°C by using an ice bath.
• Prepare an ice bath with approximately equal volumes of distilled
water and chopped ice made from distilled water.
• Immerse the temperature probe in the center of the ice bath,
taking care not to touch the ice with the probe tip.
• Ensure that the meter is measuring a temperature within ±3°C.
• To enter the Calibration mode, press and hold the CAL button for
about 5 seconds.
• The CAL tag turns on to indicate that the
Calibration mode has been entered.
Note: If the measurement is outside the
±3°C window, the meter does not
enter Calibration mode.
• When the meter reaches the stability condition, which is detected
when the measurement remains within ±0.2°C for 5 seconds,
the calibration is accepted and the reading becomes 0°C (32°F).
• The meter then automatically returns to normal mode.
Note: To exit the Calibration mode at any time, press the CAL key.
Note: User calibration cannot be entered in T1-T2 mode.
Note: User calibration is only performed on the current channel
displayed (T1 or T2).
FACTORY RECALIBRATION
All Hanna thermometers have been accurately pre-calibrated at the
factory.
It is generally recommended to have all thermometers recalibrated at
least once a year.
For an accurate recalibration, contact your nearest Hanna Customer
Service Center.
Note: To clean the meters, do not use aggressive detergents. It is
recommended to use water.
K-TYPE THERMOCOUPLE PROBES
with integral handle, 1 m (3.3') cable & mini-connector
HI 766ARoller surface probe, max 320°C/600°F
HI 766BSurface probe, max 650°C/1200°F
HI 766B190º surface probe, max 450°C/840°F
HI 766B2Spring-loaded, surface probe, max 900°C/1650°F
HI 766B3Spring-loaded, small surface probe w/insulated shaft
HI 766CPenetration probe, max 900°C/1650°F
HI 766C1Ultra-fast Penetration probe, max 300°C/570°F
HI 766DAir probe, max 300°C/570°F
HI 766E1General purpose probe, max 900°C/1650°F
HI 766FHigh temperature, flexible wire probe without handle
HI 766F1Flexible wire probe w/o handle, max 480°C/900°F
HI 766TR1Penetration probe, max 250°C/482°F
HI 766TR2Penetration long probe, max 250°C/482°F
HI 766TV1Pipe clamp probe, max 200°C/390°F
with detachable handle & mini-connector (to be used in conjunction with the HI 766HD probe handle)
HI 766PARoller surface probe, max 320°C/600°F
HI 766PBSurface probe, max 650°C/1200°F
HI 766PCPenetration probe, max 900°C/1650°F
HI 766PDAir probe, max 300°C/570°F
HI 766PE1General purpose probe, max 900°C/1650°F
grill surface probe
HI 766B4Grill surface probe with 70 cm (27.6’’) cable (protected
with stainless steel jacket), max 250°C/482°F
HI 7664B4SSpare stainless steel sensor for HI 766B4 probe
OTHER ACCESSORIES
HI 710007 / 8Shockproof rubber boot, blue / orange
HI 710018Spare protective case
HI 766EXExtension cable for K-type probes
HI 92000Windows® compatible software
HI 920011Serial cable for PC connection
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the
environment in which they are used. Operation of these instruments in residential
area could cause unacceptable interferences to radio and TV equipments, requiring
the operator to take all necessary steps to correct interferences. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC
performance. To avoid electrical shock, do not use these instruments when voltages
at the measurement surface exceed 24 Vac or 60 Vdc. To avoid damages or burns,
do not perform any measurement in microwave ovens.
1918
Page 11
SALES AND TECHNICAL SERVICE CONTACTS
Australia
Tel. (03) 9769.0666 • Fax (03) 9769.0699
China
Tel. (10) 88570068 • Fax (10) 88570060
Egypt
Tel. & Fax (02) 2758.683
Germany
Tel. (07851) 9129-0 • Fax (07851) 9129-99
Greece
Tel. (210) 823.5192 • Fax (210) 884.0210
Indonesia
Tel. (21) 4584.2941 • Fax (21) 4584.2942
Japan
Tel. (03) 3258.9565 • Fax (03) 3258.9567
Korea
Tel. (02) 2278.5147 • Fax (02) 2264.1729
Malaysia
Tel. (603) 5638.9940 • Fax (603) 5638.9829
Singapore
Tel. 6296.7118 • Fax 6291.6906
South Africa
Tel. (011) 615.6076 • Fax (011) 615.8582
Taiwan
Tel. 886.2.2739.3014 • Fax 886.2.2739.2983
Thailand
Tel. 66.2619.0708 • Fax 66.2619.0061
United Kingdom
Tel. (01525) 850.855 • Fax (01525) 853.668
USA
Tel. (401) 765.7500 • Fax (401) 765.7575
For e-mail contacts and complete list of Sales and
Technical offices, please see www.hannainst.com
20
MANK999R2 06/05