Hanna Instruments HI 4104 Instruction Manual

1
Instruction Manual
SENSOR HANDLE
HI
4000-50
HI 4004HI 4004
HI 4004HI 4004
HI 4004 HI 4104HI 4104
HI 4104HI 4104
HI 4104
Selective Electrode
Half-cell
Combination
HI 4104
CALCIUM
COMBINATION
2
HI 4004 Calcium Half-cellHI 4004 Calcium Half-cell
HI 4004 Calcium Half-cellHI 4004 Calcium Half-cell
HI 4004 Calcium Half-cell HI 4104 Calcium Combination ElectrodeHI 4104 Calcium Combination Electrode
HI 4104 Calcium Combination ElectrodeHI 4104 Calcium Combination Electrode
HI 4104 Calcium Combination Electrode
I. I.
I. I.
I.
Introduction:Introduction:
Introduction:Introduction:
Introduction: The Hanna HI 4004 and HI 4104 are ion selective elec­trodes designed for the measurement of calcium ions in aqueous solutions. They utilize a replaceable sensing mod­ule that contains an organic polymer membrane that is sensitive to calcium ions. The HI 4004 is a half-cell elec­trode that requires a separate reference. The HI 4104 is a combination ion selective electrode.
IIII
IIII
II.
SpecificationsSpecifications
SpecificationsSpecifications
Specifications
Type: PVC membrane with
organic ion exchanger
Ion measured: Calcium (Ca
2+
)
Measurement range: 1.0 M to 3 X 10
-6
M
40080 to 0.12 ppm Interference: Organic solvents and cationic detergents must be absent. Ratio of interfering ion to Ca
2+
must be less than the
ratio indicated below:
1500 0 for Na
+
sodium
7000 for Mg3+magnesium 700 for Ni
2+
nickle
30 0 for Fe
2+
ferrous
25 0 for Al
3+
aluminum
200 for NH
4
+
ammonium
35 for Cu
2+
cupric
0.001 for Pb
2+
-
lead Operating Temperature: 0-40°C Operating pH: 4 to 10 pH (see Section
XIII) Dimensions: 12 mm (OD) X 120 mm
nominal insertion
(0.47” X 4.72”) Connection: BN C
3
III. III.
III. III.
III.
Theory of OperationTheory of Operation
Theory of OperationTheory of Operation
Theory of Operation
::
::
: The HI 4004 and HI 4104 calcium electrodes are potentio­metric devices used for the rapid determination of free cal­cium ions in water, sea water and beverages. The electrode functions as a sensor or ionic conductor. The HI 4004 requires a separate reference electrode to complete its elec­trolytic circuit. The HI 4104 is a combination electrode with a Ag/AgCl reference electrode with gel stabilized Cl- electro­lyte in its inner chamber. The external reference chamber is refillable. The PVC membrane used on the sensor is impregnated with the organic ion exchanger. This organic ion exchanger is considered a carrier ionophore in that it is capable of shielding and carrying the charged calcium ion in its polar cage freely through the apolar regions of the membrane. A charge imbalance developes between the test solution and internal cell of the sensor. This voltage changes in response to the sampleís ion activ­ity. When the ionic strength of the sample is fixed, the voltage is proportional to the concentration of nitrate ions in solution. The sensor follows the Nernst Equation:
E = E
a
+ 2.3 RT/nF log A
ion
E = observed potential Ea = Reference and fixed internal voltages R = gas constant (8.314 J/K Mol) n = Charge on ion (2+) A
ion
= ion activity in sample
T = absolute temperature in K F = Faraday constant (9.648 x 104 C/equivalent)
4
IV. IV.
IV. IV.
IV.
Design elements of the HI 4004 and HI 4104Design elements of the HI 4004 and HI 4104
Design elements of the HI 4004 and HI 4104Design elements of the HI 4004 and HI 4104
Design elements of the HI 4004 and HI 4104
electrodeselectrodes
electrodeselectrodes
electrodes
Upper Cap
Spring
O-Ring
Ceramic Junction on Inner Stem
Fill Hole
O-Ring and Plug
Sensing Module
Outer Sleeve
Upper Threads
Liquid junction
SENSO
R
HANDLE
HI
4000-50
Cap
Sensing module
Sensor Handle
O-Ring
5
V. V.
V. V.
V.
Equipment required:Equipment required:
Equipment required:Equipment required:
Equipment required:
The HI 4004 requires the Hanna HI 5315 Double
junction reference electrode with HI 7082 as external electrolyte.
Hanna HI 4222 pH/ISE/mV meter or other suitable
ion or pH/mV meter (Note: log/linear graph paper is useful if an ISE (ion) meter is not available).
Hanna HI 180 magnetic stirrer or equivalent with
magnetic stirring bars (Note: Isolate beakers from stir­rer motor heat by placing insulating material such as foam or cork between them).
Hanna HI 76404 electrode holder or equivalent.
Plastic beakers (HI 740036P) or other suitable mea-
surement vessel.
VI. VI.
VI. VI.
VI.
Solutions RequiredSolutions Required
Solutions RequiredSolutions Required
Solutions Required
Standards for Calcium Measurements
0.1 M calcium standard,500 mL HI 4004-01 Ionic Strength Adjuster ISA, 500 mL HI 4004-00 Conditioning and Storage Solution Calcium storage solution, 500 mL HI 4004-45 Using volumetric pipettes and glassware make dilutions to bracket the concentration of the samples. Store samples in plastic bottles. Standards with concentrations < 10
-3
M should be prepared daily. Two mL of Hanna ISA HI 4004-00 should be added to 100 mL sample or standard.
VIIVII
VIIVII
VII.
General GuidelinesGeneral Guidelines
General GuidelinesGeneral Guidelines
General Guidelines
Ensure the o-ring is installed on modules before
screwing into the sensor handle or inner stem.
O-Ring