Hanna Instruments HI 3833 User Manual

Instruction Manual
Specifications
ReferencesInstructions
HI 3833
Phosphate
Test Kit
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
www.hannainst.com
Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction manual carefully before using
the chemical test kit. It will provide you with the necessary information for correct use of the kit.
Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately.
Each kit is supplied with:
• 1 beaker (20 mL);
• 1 color comparator cube;
• HI 3833-0 powder reagent (50 pcs).
SPECIFICATIONSSPECIFICATIONS
Range 0 to 5 mg/L (ppm) PO Smallest Increment 1 mg/L (ppm) PO Analysis Method Colorimetric Sample Size 10 mL Number of Tests 50 Case Dimensions 220x145x55 mm (8.7x5.7x2.1") Shipping Weight 160 g (6 oz.)
3–
4 3– 4
Significance and Use
At high levels, phosphates stimulate the growth of photosynthetic organisms which may contribute to eutrophication of lakes, rivers, and ponds. This makes it important to monitor and control phosphate discharges into the environment.
Phosphates can be classified as ortho, condensed or organically bound. As with existing test kits on the market, the Hanna Phosphate Test Kit will only determine ortho phosphate levels.
NOTE: mg/L is equivalent to ppm (parts per million).
Chemical Reaction
The orthosphosphate level in mg/L (or ppm) is determined by a colorimetric method. Ammonium molybdate and potassium antimonyl tartrate react in acid medium with orthophosphate to form a phosphomolybdate complex, that is reduced to intensely colored molybdenum blue by ascorbic acid. The color intensity of the solution determines the phosphate concentration.
READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT
• Remove the cap from the plastic vessel. Rinse the plastic vessel with water sample, fill it to 10 mL mark.
• Add 1 packet of reagent HI 3833-0.
• Replace the cap and mix solution until solids dissolve.
• Remove the cap and transfer the solution into the color comparator cube. Let set for 1 minute.
• Determine which color matches the solution in the cube and record the result as mg/L (ppm) of phosphate
3-
(PO
).
4
• 1987 Annual Book of ASTM Standard, Volume 11.01 Water (1). Pages 651-652.
• Standard Methods for the Examination of Water and Wastewater, 16th Edition, 1985, Pages 445-446.
Health and Safety data Sheets
The chemicals contained in this kit may be hazardous if improperly handled. Read Health and Safety Data Sheet before performing this test.
Note: Any damaged or defective item must be returned in