HANMI TECHWIN TDP-BM-100 Operating Manual

TDP-BM-100
Battery Status Monitor
OPERATING MANUAL
TEL: +82-31-498-9270
FAX: +82-31-498-9275
Battery Status Monitor TDP-BM-100
1
Contents
2
2
2
2
3
4 4
6 6
6
7
1. Introduction
2. Characteristics
3. Purpose
4. Basic Specification
5. Configuration and Operation Principle
6. Displaying data and Setting
6-1 Displaying data 6-2 Setting
7. Wiring for terminal block
7-1 Outside view of terminal block 7-2 Explanation of terminal block
8. Electrical wiring
9. Outside dimension
TDP-BM-100 Battery Status Monitor
2
1. Introduction
TDP-BM-100 is the device of emergency monitoring battery status for
magnet system. Emergency battery installed 9 to 18 in series due to output
voltage; therefore, it is difficult to check each battery status.
TDP-BM-100, which is possible to check battery individually, is to find poor
battery to show graph of battery status. In addition, it could be measured
current of charging and discharging to calculate internal resistance value, and
battery manages stably with alarming if set voltage dropped blow setting
level.
2. Characteristics
Realtime monitoring for battery status.
Battery voltage checks intuitive to show as bar graph.
It could distinct battery voltage with bar graph which color changes.
Easy to set with touch panel.
It has function to display status of charging and discharging.
It is possible to measure internal resistance value for each battery.
Output alarm for poor battery.
It could select integral type and discrete type due to installation
condition.
3. Purpose
Status of industrial battery monitoring device.
4. Basic Specification
Input voltage : AC 80 ~ 240[V] single phase or Specific battery
Touch panel : K600+ LCM
Signal output : WARNING (RELAY contact : AC250V/DC30V, 5A)
Quantity for monitoring battery : 19EA (Industrial 12V battery)
Panel communication : RS-422 (discrete type)
Temperature range for operation : -20~85[℃]
Battery Status Monitor TDP-BM-100
3
5. Configuration and Operation Principle TDP-BM-100 consists as blow picture. MCU as a key component consists
easily to check display data on touch panel as a graph type about battery status such as voltage of each voltage, total voltage of battery in series, and charging current. As well as, fault alarm will occurs to prevent negligent accident when battery has trouble.
TB
MCU
POWER
Touch
Panel
COM
Amp.
ON/
OFF
A/D
NC NO
Warning Output
Hall CT
Battery Input Current Input
[Pic1] Block diagram
[Photo1] Main board