Hangzhou Hikvision Digital Technology CP04016403111 User Manual

Hybrid Security Control Panel
A
Dimension (W × H × D)
8 8
DS-PHA64-W4M
8
6 W P
AP Mode
4
10M/100M Ethernet
I C DC09: ARC accessible (CID/SIA)
iVMS-4200 (client software) Hik-Connect (mobile client)
S Supported
4 on-board outputs, and 60 wired/wireless outputs expadable
1, 12V
1 a
1, PSTN expander interface
1, RJ45 10M/100M Ethernet Interface
1, front cover tamper-proof
S
I O
Metal Case: 351.4 mm (13.8") × 261.4 mm (10.3") × 93.3 mm (3.7")
10% to 90% (No condensing)
–10 °C to 55 °C (-4 °F to +122 °F)
12
I A M O
Storage battery (-M model)
U
O
W
I C
A P
N A
Model
Hybrid Security Control Panel with Metal Case
D c
Up to 56
Up to 8
1 2 wireless sirens
8, valid operation interval: 3 s
ENGLISH
Diagram References
1
Wiring and Installaon
1. Unlock the front cover with the supplied key, open the case of the control panel.
2. Fix the control panel case on the required place with three supplied screws.
3. Fix the SIM card module (Sold separately) with four plasc bolts.
4. Install the telephone module (Sold separately) with two plasc bolts.
5. Wire the cables.
1
Antenna Wiring (Wi-Fi and 3G/4G/GPRS Antenna)
1. Connect the pin of the pedestal to the terminal on the board or module.
2. Rotate and fix the antenna on the pedestal.
2
Network Wiring
3
Alarm Input/Alarm Output/RS-485/Power Supply Wiring
Power down the control panel before connecng and disconnecng accessories and peripherals.
21
Alarm Input Wiring
a.
NC Detector NO Detector
b.
Unoccupied Zone
c.
d.
Tamper-proof
22
Alarm Output Wiring
2
3
RS-485 Wiring: Wireless Receiver, keypad, etc.
2
4
Power Supply Wiring
Telephone Module Wiring
4
6. Close the case of the control panel. Lock the front cover with the supplied key.
2
Set Up
Set up via Web Client
Log Into the Web Client
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connecng the network cable with computer directly :192.0.0.64
Input the device IP address in the address bar of the web browser. Create a password to acvate the device and log into the web client.
Add a Camera for the Zone
The funcon varies depending on the model of device.
1. Click System-Network Camera, and you can add cameras for the control panel.
2. Enter the “Device Management” page, select a zone, and select a camera to link with the zone. You can also link a camera with the zone via APP, refer to the Security Control Panel User Manual for details.
Configure Video-Push
You can view the alarm video via APP and email. For detailed sengs, refer to Security
Control Panel User Manual.
Set up via APP
1. Log into the App Store and input Hik-Connect to search and install the mobile client.
2. Log into the APP with Hik-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel (on the lable).
4. Tap Connect to a Network. Select Wireless Connecon (AP) as the connecon mode.
5. Push the AP/STA mode switch to the AP posion, tap Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi, and click Next.
7. Create a password to acvate the device.
8. Push the AP/STA mode switch to the STA posion.
Note: You need to enter the Verificaon Code (on the device lable which is pasted on the rear panel) before acvaon if you add the device by entering the device serial No.(SN).
Set up via iVMS-4200 Client Soware
Note: Get the client soware from the official website:www.hikvision.com.
2. Enter Device Management page, select the device in the Online Device List, click Edit Network Sengs, change the port as 80, and click Add to Client.
Note: You should acvate the device for the first usage.
Specification
1
2
1
2
1
Security Control Panel
2
2
2
23
4
CAUTION
SUITABLE FOR MOUNTING ON
CONCRETE OR OTHER
NON-COMBUSTIBLE SURFACE ONLY
Z1 C Z2 Z3 C Z4 Z5 C Z6 Z7 C Z8 C1 PGM1 AUX+ BELL+ D+ DC+ BAT+C2 PGM2 C3 PGM3 C4 PGM4 AUX BELL D BATDC
N.C
N.C
N.O
N.O
2K2
2K2
EOL
EOL
2a
Peripheral Security Detector
Z
C
2.2K
N.C
N.C
N.O
N.O
2K2
2K2
EOL
EOL
NC
C
N.C
N.O
2K2 EOL
Only for device with
8 on-board zones
Security Control Panel
Z
C
N.C
N.O
2K2 EOL
2
b
Peripheral Security Detector
N.C
N.O
2K2 EOL
2.2K
N.C
N.O
2K2 EOL
NO
C
Alarm Lamp
2
2
Alarm Lamp
C1 PGM1
Alarm Lamp
Only for device with
8 on-board zones
Alarm Lamp
AUX+AUX- D- D+
2
3
OR
Siren
RS-485
AUX-
AUX+
D-
Power Adapter
D+
15VDC
2
4
2
5
Lead-acid
DC- DC+
Wi-Fi
GPRS
CN1
3G/4G
MAIN
AUX
1
2
Battery
2
3
......
4
Wireless Detector
evice
onnection
larm input
larm output Alarm output
pplication &
rotocol
etwork
i-Fi
nterface &
omponent
ser
thers
Note: The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9. The products do not contain the PSTN, 2G, 3G, or 4G funcon, but support the extension module for PSTN, 2G, 3G and 4G.
Wireless Output expander
Siren
Keyfob
Partition
Zone
Scheduled arming/disarming
SMS notification (with 3G/4G/GPRS module)
Network camera accessing
Application
Protocol
Wired network
Cellular Network (with 3G/4G/GPRS module)
Standard
Encryption
Configuration
Distance
TAMPER Switch Network Interface Telephone Interface
RS-485 Terminal
Siren Power Interface Battery Interface
User
Tag Operation Temperature Operation Humidity
wired siren (on-board connection)
on-board zones, and 56 wired/wireless zones expadable
upports up to 8 mobile phone numbers
SAPI: Supports client software and web client
loud P2P: Supports cloud P2P privacy protocol
upports report push- notification to ARC & Cloud
02.11b/g/n
4/128-bit WEP,WPA/
PA2,WPA-PSK/WPA2-
SK,WPS
ndoor: 50 m
utdoor: 100 m
, extended up to 64 inputs/outputs (with RS-485 module), nd 9 wired keypads extendable
nstaller: 1
dministrator: 1
anufactuer:1 perator: 45
2
c 2d
Security Control Panel
Z
C
Z
C
2
AP STA AP STA
The AP mode is only Supported by device with Wi-Fi funcon.
2.2K Ω
TAMPER
NC
2.2
D ET EC T OR
NO
Set up via APP
25 2
AP STA AP STA
8
Dry Contact
……
COPER OR COPER WIRE CANNOT BE
EXPOSED AT THE ELECTRICAL TERMINAL
CAUTION
Product Informaon
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED. Any and all informaon, including, among others, wordings, pictures, graphs are the properes of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinaer referred to be “Hikvision”). This user manual (hereinaer referred to be “the Manual”) cannot be reproduced, changed, translated, or distributed, parally or wholly, by any means, without the prior wrien permission of Hikvision. Unless otherwise spulated, Hikvision does not make any warranes, guarantees or representaons, express or implied, regarding to the Manual.
About this Manual This Manual is applicable to the Axiom Security Control Panel Kit. The Manual includes instrucons for using and managing the product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change, without noce, due to firmware updates or other reasons. Please find the latest version in the company website (hp://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned below are the properes of their respecve owners.
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the RE Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the LVD Direcve 2014/35/EU, the RoHS Direcve 2011/65/EU
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collecon points. For more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentaon for specific baery informaon. The baery is marked with this symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the baery to your supplier or to a designated collecon point. For more informaon see:www.recyclethis.info
Line
Line
Telephone
Telephone
Telephone
Telephone
Telephone Line Cut Off Indicator
Power Indicator
Telephone Module
FCC Informaon Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separaon between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Condions This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon
UD15862B