Hangzhou Hikvision Digital Technology CP04016401111 User Manual

Hybrid Security Control Panel
(with 3G/4G/GPRS module)
Cellular Network (with 3G/4G/GPRS module)
1, 12V
Lithium battery (-P model)
Installer: 1 A M O
12
–10 °C to 55 °C (-4 °F to +122 °F)
10% to 90% (No condensing)
P
802.11b/g/n
6 W PSK,WPS
AP Mode
Indoor: 50 m Outdoor: 100 m
1, front cover tamper-proof
1, RJ45 10M/100M Ethernet Interface
1, PSTN expander interface
1, extended up to 64 inputs/outputs (with RS-485 module), a
i Hik-Connect (mobile client)
I C DC09: ARC accessible (CID/SIA)
10M/100M Ethernet
S 8
8
4 on-board outputs, and 60 wired/wireless outputs expadable
Supported
S 4
Hybrid Security Control Panel with Plastic Case
Up to 56
Up to 8
1 2 wireless sirens
8, valid operation interval: 3 s
ENGLISH
Diagram References
Appearance
1
Indicators Components
1
AC Power
2
2
Fault
2
3
Link
4
Arm/Disarm
5
Alarm
Note: Remove the rear cover, and some of the components and interfaces are on the rear panel.
2
Wiring and Installaon
1. Loosen the screw on the top, press the lock nut, and open the case of the control panel.
2. Route the cables, and secure the rear cover in the installaon posion with the supplied screws.
3. Fix the SIM card module (should be purchased separately) with four plasc bolts.
4. Fix the telephone module (should be purchased separately) with two plasc bolts.
5. Wire the cables .
Telephone Module Wiring
1 2
Alarm Input/Alarm Output/RS-485 Wiring
21
22
23
Network
3
Power Supply
4
6. Connect the baery to the control panel.
Note: The condion of no SIM card, no baery, AC power off, or network disconnected, will cause Control Panel Fault.
7. Fix the power cables with the cable clip.
8. Close the control panel, and ghten the top screws to complete the installaon. TAMPER Screw
It is compulsory to secure the TAMPER screw.
3
Set Up
Set up via Web Client
Log Into the Web Client
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connecng the network cable with computer directly :192.0.0.64
Input the device IP address in the address bar of the web browser. Create a password to acvate the device and log into the web client.
Add a Camera for the Zone
The funcon varies depends on the model of device.
1. Click System-Network Camera, and you can add cameras for the control panel.
2. Enter the “Device Management” page, select a zone, and select a camera to link with the zone. You can also link a camera with the zone via APP, refer to the Security Control Panel User Manual for details.
You can view the alarm video via APP and email. For detailed sengs, refer to Security
Control Panel User Manual.
Set up via APP
1. Log into the App Store or Google Play and input Hik-Connect to search and install the
mobile client.
2. Log into the APP with Hik-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel(on the lable).
4. Tap Connect to a Network. Select Wireless Connecon (AP) as the connecon mode.
5. Push the AP/STA mode switch to the AP posion, tab Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi , and
click Next.
7. Create a password to acvate the device.
8. Push the AP/STA mode switch to the STA posion.
Note: You need to enter the Verificaon Code (on the device lable which is pasted on the rear panel) before acvaon if you add the device by entering the device serial No.(SN).
Set up via 4200 Client
1. Download and install the iVMS-4200 client.
Note: Get the client soware from the official website:www.hikvision.com.
2. Enter Device Management page, select the device in the Online Device List, click Edit
Network Sengs, change the port as 80, and click Add to Client.
Note: You should acvate the device for the first usage.
Restore Default Sengs
Reboot the device. Boot the device, and hold the reset buon for 5s aer the Fault indictaor
flashes 3 mes. The device will prompt a message to indicates the operaon status.
Power On
System Fault
Panel is added to Hik-connect account Panel is not added to Hik-connect account
Armed
Alarm Occurred No Alarm
Alarm Input Wiring
a.
NC Detector NO Detector
b.
Unoccupied Zone
c. d.
Tamper-proof
Alarm Output Wiring
RS-485 Wiring: Wireless Receiver, keypad, etc.
Power Off
No Fault
Disarmed
Device Tampered
Specification
Model DS-PHA64-W4P
Wireless Detector
Device connection
Alarm input
Alarm output Alarm output
Application & Protocol
Network
Wi-Fi
Interface & Component
User
Others
Note: The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9. The products do not contain the PSTN, 2G, 3G, or 4G funcon, but support the extension module for PSTN, 2G, 3G and 4G.
Wireless Output expander
Siren
Keyfob Partition
Zone
Scheduled arming/disarming SMS notification
Network camera accessing
Application
Protocol
Wired network
Standard
Encryption
Configuration
Distance
TAMPER Switch Network Interface Telephone Interface
RS-485 Terminal
Siren Power Interface Battery Interface
User
Tag Operation Temperature Operation Humidity
Dimension (W × H × D)
wired siren (on-board connection)
on-board zones, and 56 wired/wireless zones expadable
upports up to 8 mobile phone numbers
VMS-4200 (client software)
SAPI: Supports client software and web client
loud P2P: Supports cloud P2P privacy protocol
upports report push- notification to ARC & Cloud
4/128-bit WEP,WPA/
PA2,WPA-PSK/WPA2-
nd 9 wired keypads extendable
dministrator: 1
anufactuer:1
perator: 45
lastic Case: 220 mm (8.6") × 152 mm (6.0") × 31.5 mm(1.2")
2
6
2
7
2
8
2
9
Lock Nut
Power Interface
Wiring
Terminal
Network Interface
2
10
2
11
2
12
2
13
Reset
Buon Baery
Connector
TAMPER Switch
AP&STA Switch
1 2
1 22 23 24 25
2
2827
6
2
29
2
10
2
11
212
APSTA APSTA
213
2
Line
Line
Telephone
Telephone
Telephone
Telephone
220V ~
CON101 L
N
1
Powe r Adapt er
12V
AUX+AUX- D- D+
Telephone Line Cut Off Indicator
Telephone Module
12VD C
G NO/NC2COM2 NO/NC3COM3NO/NC4COM4
485+
485
2
3
OR
……
Keypad
AUX-
Siren
AUX+
Alarm
Alarm
Lamp
Lamp
GG
2
D-
2
D+
C1 PGM1
Dry Contact
Power Indicator
Alarm
Alarm
Lamp
Lamp
2
1
Security Control Panel
Security Control Panel
4
CON101
GND
220 V~
2K2 EOL
N.O
N.C
Z1 G Z2 Z3 G Z4 Z5 G Z6 Z7 G Z8NO/NC1COM112V_AUX12V_BELL
N
NULL
Line
2K2 EOL
N.O
N.C
4
Causc
Line
L
2a
Peripheral Security Detector
2.2K
NC
C
Z
C
2
c 2d
Z
C
3
Set up via APP
25 2
STA
AP
STAAPSTA
AP
The AP mode is only Supported by device with Wi-Fi funcon.
8
STA
AP
21 22
2
THROUGH THE REAR PANEL. DO NOT
ROUTE THE ANTENNA WIRE THROUGH
2K2
2K2
EOL
EOL
N.O
N.O
N.C
N.C
3
CAUTION
CABLES CAN ONLY BE ROUTED
THE ELECTRICAL BOARD
2K2
2K2
2K2
2.2K Ω
2K2
EOL
EOL
N.O
N.O
N.C
N.C
2
b
Peripheral Security Detector
2.2K
TAMPER
2.2K Ω
DE T EC T OR
NO
C
NC
NO
EOL
N.O
N.C
Security Control Panel
Z
C
Z
C
EOL
N.O
N.C
Product Informaon
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd. ALL RIGHTS RESERVED. Any and all informaon, including, among others, wordings, pictures, graphs are the properes of Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinaer referred to be “Hikvision”). This user manual (hereinaer referred to be “the Manual”) cannot be reproduced, changed, translated, or distributed, parally or wholly, by any means, without the prior wrien permission of Hikvision. Unless otherwise spulated, Hikvision does not make any warranes, guarantees or representaons, express or implied, regarding to the Manual.
About this Manual This Manual is applicable to the Axiom Security Control Panel Kit. The Manual includes instrucons for using and managing the product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change, without noce, due to firmware updates or other reasons. Please find the latest version in the company website (hp://overseas.hikvision.com/en/). Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned below are the properes of their respecve owners.
SUITABLE FOR MOUNTING ON
CAUTION
CONCRETE OR OTHER
NON-COMBUSTIBLE SURFACE ONLY
2
6
2
1
3
......
2
7
CAUTION
COPER OR COPER WIRE CANNOT BE
EXPOSED AT THE ELECTRICAL TERMINAL
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the RE Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the LVD Direcve 2014/35/EU, the RoHS Direcve 2011/65/EU
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collecon points. For more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentaon for specific baery informaon. The baery is marked with this symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the baery to your supplier or to a designated collecon point. For more informaon see:www.recyclethis.info
3 24
2
2
5
2
8
CAUTION
A TWO-POLE DISCONNECTED
DEVICE (BREAKER) SHALL BE PROVIDED WHEN INSTALLED
FCC Informaon Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separaon between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Condions This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon
CAUTION
RISK OF EXPLOSION IF
BATTERY IS REPLACED BY AN
INCORRECT TYPE
DISPOSE OF USED BATTERIES
ACCORDING TO THE
INSTRUCTIONS
UD15863B-A
Loading...