Handöl 51, 52T, 54, 52, 53 Installation Instructions Manual

...
INSTRUCTIONS
51  52  52T 53  54  54T 
50
GB
Installation
GB
50
Quality approval
The stove has been tested by the Swedish National Testing and Research Institute and meets the applicable regulations for CE approval and the stricter requirements for P marking. Certificate number for P Marking: 22 03 16.
Manufacturer’s assurance
Manufacture of the product has taken place in accordance with those documents which are the basis for the relevant type approval certification and the required manufacturing checks.
Requirements for flue
The chimney must be dimen­sioned for at least 350° C for both top connection directly upwards and connection directly backwards from the rear of the stove.
Handöl 50 is the first cast iron stove in the world to be swan marked
As the premier stove manufacturer in Sweden, we at NIBE Brasvärme are committed to Swan marking our stoves. Choosing to Swan mark our products is one aspect of our vision to be a company of the future with equally high quality standards regarding the environment. Certifcate number 378-001.
Certifierad
Certifikat nr
22 03 16
NOTE! Notify the local building authorities of the new installation
Report installation of a stove to your local authority.
The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector.
Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney­sweeping services.
EU-declaration of conformity
Product covered by this declaration Product type Stove fired by fixed fuel Type designation Handöl 50-series Type acc. to standard SS-EN 13240 Intended for use Heating of living accomodation Fuels Wood logs Special conditions None Manufacturer
Name NIBE AB/NIBE Brasvärme Address Box 134, Skulptörvägen 10, SE-285 23 MARKARYD Place of manufacture Markaryd
Manufacturing check by approved organisation
Name Swedish National Testing and Research Institute AB Address Box 857, SE-501 15 BORÅS Report no / date -/-
Niklas Gunnarsson Business area manager NIBE Stoves
Appendices
• Assembly and Installation Instructions
HAND ÖL
In accordance with standards below marking was affixed: European Standard: SE Quality Certification, P-marked: NO Standard NS 3059: DK Standard: DE and AT Standard DIN 18 891 and Art 15a B-VG: Type: Nominal Output: Fuel: Minimun draught: Flue gas temerature: Energy efficiency: Emission of CO in cumbustion products: Distance to cumbustible wall (mm):
Production number:
Follow the installation instructions. Use only recomended fuels
NIBE AB Box 134 SE-285 23 MARKARYD AWEDEN
2006 EN 13240 Cert no 220316 SINTEF 043-xxx xxxDS/EN 13240 plus
XX-91xxxx H51/H52/H52T 5 kW Wood 12 Pa 275°C 79% 0,13% Behind 150 Beside 500 Corner 150
HAND ÖL
In accordance with standards below marking was affixed: European Standard: SE Quality Certification, P-marked: NO Standard NS 3059: DK Standard: DE and AT Standard DIN 18 891 and Art 15a B-VG: Type: Nominal Output: Fuel: Minimun draught: Flue gas temerature: Energy efficiency: Emission of CO in cumbustion products: Distance to cumbustible wall (mm):
Production number:
Follow the installation instructions. Use only recomended fuels
NIBE AB Box 134 SE-285 23 MARKARYD AWEDEN
2006 EN 13240 Cert no 220316 SINTEF 043-xxx xxxDS/EN 13240 plus
XX-91xxxx H53/H54/H54T 5 kW Wood 12 Pa 275°C 79% 0,13% Behind 150 Beside 470 Corner 150
378
001
N
O
R
D
I
C
E
C
O
L
A
B
E
L
GB
51
TABLE OF CONTENTS
General 52 Installation distance to walls and ceiling 53 Removing the loose components 55 Supply of combustion air 57 Adjusting and connecting H51 58 Adjusting and connecting H52/H52T 59 Adjusting and connecting H53 61 Adjusting and connecting H54/H54T 62 Connection to the chimney 64
DEAR HANDÖL OWNER
We welcome you to the Handöl family and hope that you will
gain much pleasure from your stove. We understand that you
place high demands on both quality and design. As a new
owner of a stove from Handöl you have a stove with timeless
design and a long lifetime.
The stove combustion is also environmentally friendly and
efficient for the best heat production.
Read the installation instructions carefully before you begin
installation and the separate lighting and user instructions
before you light the fire.
WARNING! The stove becomes very hot when lit
During operation, certain surfaces of the stove become very hot and can cause burn injury if touched. Be aware of the strong heat radiated through the hatch glass. Placing flammable material closer than the safe distance indicated may cause a fire. Pyre lighting can cause quick gas ignition with the risk of damage to property and personal injury.
GB
52
General
This manual contains instructions about how the Handöl 50 series must be assembled and installed.
To guarantee the function and safety of the stove we recommend that it is installed by a professional. Our Handöl agents can recommend a suitable installer.
Instructions for lighting and use are also supplied with the stove. Read them carefully and keep them safe for future use.
The stove is type approved and must be connected to a chimney dimensioned for at least 350°C, the external connection diameter is Ø150 mm. Supply air from the open air should be used as combustion air.
Building application
Before installing a stove or erecting a chimney it is necessary for you to apply for planning permission from your local authority. Ask your local authority for advice regarding building regulations and the application.
Structural support
Check that the wood joists are strong enough to bear the weight of the stove and chimney. The stove and chimney can usually be placed on a normal wooden joist in a single occupancy house if the total weight does not exceed 400 kg.
Hearth plate
To protect the floor from any embers the stove must be placed on a hearth plate. If the floor under the stove is flammable, it must be protected by a non-flammable material which covers at least 300 mm to the front and 100 mm on each side. The hearth plate can consist of natural stone, concrete or 0.7 mm metal. As an accessory, the hearth plate is available in painted steel.
Chimney
The stove requires a draft in the chimney of at least –12 Pa. The draught is affected both by the length and area of the chimney, and by how well sealed it is. Minimum recommended chimney length is 3.5 m and a suitable cross section area is 150-200 cm² (140-160 mm in diameter). Carefully check that the chimney is sealed and that there is no leakage around soot hatches and flue connections.
Note that a flue with sharp bends and horizontal routing reduces the draught in the chimney. Maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot hatches must be easily accessible.
Eldstadsbeklädnad
Löstagbart handtag
Rosterreglage
Asklåda
Förbränningsluftsreglage
Brasbegränsare
Typskylt
ANVISNING
51
52
52T
53
54
54T
50
ins talla tion s
Installationsanvisning 2 Installasjonsanvisning
5
Heizinstruktionen
8
Installationinstruction 11
Monteringsveiledning
14
Lämmity
17
Instructions
d’installation
20
Istruzioni
per
l’installazione
23
Installatievoorschriften 26
SE
NO
GB
DK
FI
IT
NL
DE
FR
eldnings
instruktion
H
 50
Eldningsinstruktion 2
Heizinstruktionen 5
Fyringsinstruksjon 8
Fyringsvejledning 11
Istruzioniperl’accension e 14
Instructionsd’allumage 17
Stookinstructies 20
LightingInstructions 23
Lämmity 26
SE
DE
NO
DK
IT
FR
NL
GB
FI
HANDÖL
In accordance with standards below marking was affixed: European Standard: SE Quality Certification, P-marked: NO Standard NS 3059: DK Standard: DE and AT Standard DIN 18 891 and Art 15a B-VG: Type: Nominal Output: Fuel: Minimun draught: Flue gas temerature: Energy efficiency: Emission of CO in cumbustion products: Distance to cumbustible wall (mm):
Production number:
Follow the installation instructions. Use only recomended fuels
NIBE AB Box 134 SE-285 23 MARKARYD AWEDEN
2006 EN 13240 Cert no 220316 SINTEF 043-xxx xxxDS/EN 13240 plus
XX-91xxxx H51/H52/H52T 5 kW Wood 12 Pa 275°C 79% 0,13% Behind 150 Beside 500 Corner 150
Technical data
Output 3-7 kW Nominal output 5 kW Efficiency level 79%
Model 51 52 52T 53 54 54T Weight (kg) 128 135 172 143 149 190 Width (mm) 495 495 495 550 550 550 Depth (mm) 420 420 420 455 455 455 Height (mm) 825 825 875 825 825 875
The connection’s external diameter is Ø150 mm. Type approved in accordance with:
European standard EN-13240 Swedish environmental and quality marking, P-marking cert. no. 22 03 16 Norwegian standard NS 3059, Cert. No xxx-xxx German standard DIN 18.891, XX-xx xx xxx
Fire-box surround
Grate shuttle
Ash-pan
Log guard
Air supply control
Removable handle
Type plate
GB
53
Installation distance to walls and ceiling
295
A 825
495
520
2000
Brännbart tak
420
135
D 20
B 705
C 65
Position the stove on a hearth plate and check that the installation distances given in the diagrams are met. The minimum distance between the stove opening and combustible parts of the building or décor must be at least 1 m.
When top connecting a steel flue please refer to the relevant manufacturer’s installation instructions. Observe the safety distances to combustible material that steel flues require.
390
Brännbar vägg
150
840
735
280
Brännbar vägg
150
500
745
100
200
300
400
80
180
280
380
H51, H52 and H52T
*To prevent the discolouring of painted fire walls, we recommend a side distance the same as for the combustible wall.
290
Brandmur
50
700
635
180
Brandmur
50
140*
385*
A = height from floor to top flue connection, Ø150
B = height from floor to c /c smoke outlet rear
, Ø150
C = distance from back to
top flue (c/c), Ø64
D = distance from back to smoke outlet rear
, Ø150
280
Brännbar vägg
150
500
745
Tillåtet område för brännbart material
100
200
300
400
80
Combustible ceiling
Combustible wall
Fire-retardant wall of brick or concrete
Permit ted area fo r combus tible material.
Combustible wall
Fire-retardant wall of brick or concrete
GB
54
Installation distance to walls and ceiling
295
A 825
550
2000
Brännbart tak
455
165
D 55
B 705
C 100
Position the stove on a hearth plate and check that the installation distances given in the diagrams are met. The minimum distance between the stove opening and combustible parts of the building or décor must be at least 1 m.
When top connecting a steel flue please refer to the relevant manufacturer’s installation instructions. Observe the safety distances to combustible material that steel flues require.
350
Brännbar vägg
150
785
695
315
Brännbar vägg
150
470
745
200
300
400
500
100
200
300
400
100
H53, H54 and H54T
* To prevent the discolouring of painted fire walls, we recommend a side distance the same as for the combustible wall. ** Minimum installation distance when using Handöl 50 base plate, applies when combustion air is obtained from the room
and when connecting outdoor air through the floor. If outdoor air is NOT to be connected through the floor, the stove can be placed 50 mm from fire walls if Nibe’s tear-drop shaped base plate is used.
215
Brandmur
50
110*
385*
245, 350**
Brandmur
50, 150**
635, 785**
590, 695**
A = height from floor to top flue connection, Ø150
B = height from floor to c /c smoke outlet rear
, Ø150
C = distance from back to top flue (c/c)
, Ø64 v
D = distance from back to smoke outlet rear
, Ø150
280
Brännbar vägg
150
500
745
Tillåtet område för brännbart material
100
200
300
400
80
Combustible ceiling
Permit ted area fo r combus tible material.
Combustible wall
Fire-retardant wall of brick or concrete
Combustible wall
Fire-retardant wall of brick or concrete
GB
55
Removing the loose components
Fire bars
Lift the fire bars straight up, clean the ash from the guide groove in the stove base plate before repositioning it in position.
Fire box surround
When sweeping, the smoke baffle must be lifted out, this can be done when one side has been dismantled.
Smoke baffle
GB
56
Stove base plate
The stove base plate is lifted out when all the cladding has been removed.
Fixed or removable handle
The stove handle is fitted on delivery. To make the handle removable, replace the screw for the lock hook with the shorter screw supplied.
GB
57
Supply of combustion air
Combustion air can be provided directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is to be placed. The amount of combustion air used for combustion is approximately 25 m3/h.
Some installation alternatives are shown to the right. On certain models, H54 and H54T, when supply air is retrieved via walls behind, there is a knock out for inserting the combustion air hose, see figure below.
The air duct connection on the stove has an external diameter of Ø64 mm.
In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed using jointing compound. When duct routing for further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected.
A 1 m length of condensation insulated ducting for combustion air is available as an accessory.
HK
HK
HK
HK
30 mm
Cover for H51, H52, H52T and 53
Ducting to cover the outdoor air connection hose is available (accessory). The duct can be installed after the stove is installed.
Knock out on H54 and H54T
To insert the combustion air hose, the knockout in the base is tapped out using a hammer, remember to protect the floor.
GB
58
Adjusting and connecting
Preparations before rear connection
The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around.
• Dismantle the cladding as instructed previously, see
page 55.
• Tap out the knock out in the stove’ s back panel, remember to protect the floor.
• Then unscrew both the connector and the cover.
• Switch places and reinstall the screws.
Handöl 51
Adjusting the stove
• Position the stove on the hearth plate.
• Uninstall the rear sections of the legs.
• Adjust the height of the four adjustable feet until the stove is horizontal.
• When the rear sections have been reinstalled, cover the screws with the plastic plugs supplied.
GB
59
Adjusting and connecting
Preparations before rear connection
The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around.
• Dismantle the cladding as instructed previously, see page 55.
• Tap out the knock out in the stove’ s back panel, remember to protect the floor.
• Then unscrew both the connector and the cover.
• Switch places and reinstall the screws.
Handöl 52 / 52T
Adjusting the stove
• Position the stove on the hearth plate.
• Uninstall the inner covers of the legs.
• Adjust the height of the four adjustable feet until the stove is horizontal.
• When the inner sections have been reinstalled, cover the screws with the plastic plugs supplied.
GB
60
Soapstone installation Handöl 52T
Handle soapstone with care, the edges are susceptible to damage. Soapstone is most easily cleaned using a cloth damp­ened with acetone.
• Remove the upper securing plate.
• Position with the decorative groove downward so that the turned up edge holds the soapstone in place.
• Install and secure the upper securing plate so that panel edge locks the soapstone.
• Do the same on the opposite side and then position the soapstone cap.
• When connecting from behind, position the cover provided over the hole for the top connection.
A hotplate is available as an accessory for installation in the hole in the top plate.
Continue with the section ”Connecting to the chimney” on page 64.
GB
61
Adjusting and connecting
Preparations before rear connection
The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around.
• Dismantle the cladding as instructed previously, see page 55.
• Tap out the knock out in the stove’ s back panel, remember to protect the floor.
• Then unscrew both the connector and the cover.
• Switch places and reinstall the screws.
Handöl 53
Adjusting the stove
• Position the stove on the hearth plate.
• Uninstall the rear sections of the legs.
• Adjust the height of the four adjustable feet until the stove is horizontal.
• When the rear sections have been reinstalled, cover the screws with the plastic plugs supplied.
50
Continue with the section ”Connecting to the chimney” on page 64.
GB
62
Adjusting and connecting
Preparations before rear connection H54
The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around.
• Dismantle the cladding as
instructed
previously, see page 55.
• Tap out the knock out in the stove’ s back panel, remember to protect the floor.
• Then unscrew both the connector and the cover.
• Switch places and reinstall the screws.
Handöl 54 / 54T
Preparations before rear connection H54T
The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around.
• Unscrew both the upper screws and lift off the back.
• Tap out the knock out in the stove’ s back panel, tap from the inside of the back, remember to protect the floor.
• Then unscrew both the connector and the cover.
• Switch places and reinstall the back.
GB
63
Adjusting the stove
Soapstone installation H54T
Handle soapstone with care, the edges are susceptible to damage. Soapstone is most easily cleaned using a cloth dampened with acetone.
• Remove the upper securing plate.
• Position with the decorative groove downward in the lower soapstone holder so that the turned up edge holds the soapstone in place.
• Install and secure the upper securing plate so that panel edge locks the soapstone.
• Do the same on the opposite side and then position the soapstone cap.
• When connecting from behind, position the cover provided over the hole for the top connection.
A hotplate is available as an accessory for installation in the hole in the top plate.
Continue with the section ”Connecting to the chimney” on page 64.
Position the stove on the hearth plate. Unscrew the cover plate.
Twist the cover plate as indicated by the arrow.
Adjust the adjustable feet until the stove is horizontal and then reinstall the cover plate.
GB
64
IAV SE-EX 0718-3 511866
NIBE AB/ NIBE BRASVÄRME · Box 134 · 2 85 23 Mark aryd ww w.han dol.eu
Connection to the chimney
After the stove has been adjusted and positioned according to the installation distances, connec­tion to the chimney is carried out. Select one of the following alternatives.
Top connection to the steel flue
Press the start pipe onto the connection, continue the chimney installation according to the chimney installation
instructions.
LEK
LEK
LEK
Mark out centre for making a hole in the wall to the flue. Check that the connection height in the chimney breast corresponds to the height of the connection pipe from the stove.
Cut a hole approximately 180 mm in diameter.
Then cement in a wall connector with fire proof mortar (not supplied). Let the mortar dry before the stove is connected to the chimney.
LEK
LEK
LEK
Rearwards to a masonry chimney
Connection to a masonry chimney can be the back or the top of the stove.
Install the connection pipe on the connection. Make sure that the gasket does not work loose from its position. Caulk between the connection pipe and the connector in the wall using caulking rope. If further sealing material is required, heat-resistant sealant may be used.
Nibe Brasvärme res erves the right to change colours, materials, dimensions and mo dels at any time without special notice. Your dealer can provide you with t he latest information.