HAMPTON BAY Devereaux II, Sussex II, Trusseau, Trusseau 324-683, Devereaux II 321-977 Owner's Manual

Devereaux II 52
in Ceiling Fan
Owner’s Manual
Devereaux II Ventilador de Techo de 1,32
Manual del Propietario
321-977
Devereaux II by Hampton Bay
®
52” Devereaux II
Ceiling Fan by Hampton Bay
Date Purchased
Store Purchased
Model No.
Serial No.
Vendor No.
UPC
Thank you for purchasing our ceiling fan. This product has been manufactured with the highest standards of safety and quality.
Table of Contents
Safety Rules . . . . . . . . . . . . . . . . . . . . 1
Unpacking Your Fan . . . . . . . . . . . . . . 2
Installing Your Fan . . . . . . . . . . . . . . . 3
Installing the Light Kit. . . . . . . . . . . . . 10
Operating Your Transmitter . . . . . . . . . . . 11
Care of Your Fan . . . . . . . . . . . . . . . . 13
Troubleshooting . . . . . . . . . . . . . . . . . 13
Specifications . . . . . . . . . . . . . . . . . . 14
Warranty Information . . . . . . . . . . . . 15
321-977
792145355960
219032
Safety Rules - Read and Save These Instructions
To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.
All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-1999” and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
WARNING: To reduce the risk of electrical shock or fire, do not use this fan with any solid-state fan speed control device. It will permanently damage the electronic circuitry.
CAUTION: To reduce the risk of personal injury, use only the screws provided with the outlet box.
The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds, Use only UL Listed outlet boxes marked “FOR FAN SUPPORT”.
The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
Avoid placing objects in the path of the blades.
To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
After making electrical connections, spliced conductors should be turned upward and pushed carefully up into outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
All set screws must be checked and retightened where necessary before installation.
1
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
WARNING
TO REDUCE THE RISK OF PERSONALL INJURY, DO NOT BEND THE BLADE ARMS (ALSO REFERRED TO AS FLANGES), WHEN INSTALLING THE BRACKETS, BALANCING THE BLADES OR CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS IN– BETWEEN ROTATING FAN BLADES.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE OUTLET BOX.
ATTENTION
FAN INCLUDES A 190W LIMITER TO COMPLY WITH THE DEPARTMENT OF ENERGY 2009 REGULATION. LAMPING THIS PRODUCT OVER 190W WILL CAUSE THIS FAN TO NOT LIGHT. PLEASE USE BULBS WITH A TOTAL WATTAGE UNDER THE 190W REGULATION.
2
Unpacking Your Fan
Unpack your fan and check the contents. You should have the following items:
AB
C
1
2
3
4
5
6
7
8
5
9
10
12
11
14
13
Set of blades (5) Canopy assembly Ball/downrod assembly Coupling cover Fan motor assembly Blade arms (5)
1.
2.
3.
4.
5.
6.
Mounting plate Light kit assembly Glass shade Glass frame 40 Watt E12 candelabra bulbs (3) Receiver with 6 wire nuts Transmitter+holder+2 mounting screws 12V MN21/A23 battery
7.
8.
9.
10.
11.
12.
13.
14.
Blade Attachment Hardware (16 Screws with Fiber Washers)
Electrical Hardware (3 Plastic Wire Nuts)
Balance Kit
A.
B.
C.
WARNING
DO NOT INSTALL OR USE FAN IF ANY
PART IS DAMAGED OR MISSING.
CALL TOLL FREE 1-877-902-5588.
3
Installing Your Fan
Figures 1~3 are examples of different ways to mount the outlet box.
If there isn't an existing UL listed mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers.
Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the moving weight of the fan (at least 35 lbs). Do not use plastic outlet boxes.
Tools Required
Mounting Options
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN ONLY TO AN OULET BOX MARKED ACCEPT­ABLE FOR FAN SUPPORT AND USE THE MOUNTING SCREWS PROVIDED WITH THE OULET BOX. OUTLET BOX COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURE MAY NOT BE ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.
Outlet Box
Outlet Box
Outlet Box
Figure 2
Figure 1
Note: You may need a longer downrod to maintain proper blade clearance when installing on a steep, sloped ceiling. The maximum angle allowable is 19°. If the canopy touches downrod, remove the decorative canopy bottom cover and turn the canopy 180° before attaching the canopy to the mounting plate.
To hang your fan where there is an existing fixture but no ceiling joist, you may need an installation hanger bar as shown in Figure 4 (available at any Home Depot store).
Ceiling Mounting Plate
Provide Strong Support
Recessed Outlet Box
Figure 3
Figure 4
Phillips screwdriver, straight slot screwdriver, step ladder and wire cutters.
Loading...
+ 12 hidden pages