HAMPTON BAY HB-4190 Installation Manual

Mode: On-Time Works: Day Night
Test 5 Seconds x x Auto 1, 5, or 10 Min x Manual To Dawn* x Accent 3,6 Hr, to Dawn x
Motion Sensing Cast Aluminum Lantern
HB-4190 Series
• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during day­light hours.
Requirements
• The Light Control requires 120 volts AC.
• If you want to use Manual Mode, the con­trol must be wired through a switch.
Some codes require installation by a
qualified electrician.
© 2003 595-5770-01
OPERATION
* resets to Auto Mode at dawn.
Set the ON-TIME switch on the bottom of the cover plate to TEST.
TEST 1510MIN
Set ON-TIME switch to 1, 5 or 10 minutes.
1 Second
OFF
then
...
Manual mode only works at night because daylight re­turns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
... back on.
Mode Switching Summary
Dual Brite® Dimmer Control
Light comes on half bright for selected time after dusk (3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 10 minutes) then returns to dim mode.
This package includes:
• Lantern
• Easy to use universal mounting bracket (X-Bar)
• Mounting hardware
• Wire nuts
ON-TIME Switch at 1,
5, or 10 minutes
Flip light switch
off for one second
then back on*
* If you get confused while switching modes,
turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
MANUAL MODE
AUTO
TEST
Note: When first turned on wait about 1 1/
2
minutes for the circuitry to calibrate.
TEST
AUTO
MANUAL MODE
TEST 1510MIN
2
595-5770-01
INSTALLATION
For best performance, mount the fixture about 6 feet (1.8 m) above the ground.
1. Remove
two nuts.
2. Remove
X-Bar.
Junction
Box
5. Attach X-Bar to
junction box
Due to the size and weight of the fixture, you may find it helpful to have an assistant hold the fixture in place while connecting the wires.
WIRING
One Motion Light
BLACK
WHITE
Two Motion Lights
BLACK
BLACK
WHITE
Recommended Grounding Method
Use a green ground "pigtail" (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the "pigtail" with the GND screw on the X-bar.
Twist the junction box wires and the fix-
ture wires together as shown below. Se­cure with wire connectors. If you have a metal junction box, you may not need the green “pigtail”. If you are unsure about the grounding method, consult your local building code.
CAUTION: DO NOT connect the RED wire
unless you want to control other lights from the motion sensor.
Black to black
White to white
MAX
MIN
3. Tighten screws
finger tight.
SENSITIVITY
Turn power off at the circuit breaker or
fuse.
4. Set sensitivity on
fixture back to the
mid-position.
3
595-5770-01
Wiring to Motion Light &
Standard Fixture
BLACK
WHITE
BLACK
(Standard)
When wiring to additional standard
fixture only: Strip the motion sensor's red wire and connect to the standard
light's black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A.).
NOTE: All wiring between fixtures should be
run in accordance with the National Elec­trical Code (Canadian Electrical Code in Canada) through conduit or another ac­ceptable means. Contact a qualified
electrician if there is any question as to the suitability of the system.
This fixture is provided with a sensor rated
for 360 Watts. Since the fixture is only rated 100 Watts (180 Watts candelabra), 260 Watts (180 Watts candelabra) of additional load may be controlled by this sensor.
When determining what a fixture is rated
for, do not simply look at the rating on the lamp in the fixture. Look at the marking which specifies the maximum lamp watt­age for which the fixture is suitable.
Once you have selected the fixtures to be
connected and determined their maxi­mum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respec­tively, you have a total load of 325 Watts.
RED
WHITE
BLACK
BLACK
Master
Slave
Wiring to Control One Motion Sensing
Lantern (Slave) from Another (Master)
RED
OPTIONAL WIRING
4
595-5770-01
COMPLETE THE INSTALLATION
Stuff the wires into the junction box. Make
sure none of the wires get pinched.
Slide the fixture onto the
mounting screws and
tighten nuts.
Install one 100 Watt max. light bulb, or
three 60 Watt bulbs in candelabra style.
Install the fixture top. Secure with
decorative screws.
After completing the tests on page 5,
caulk fixture mounting surface with silicone weather sealant.
Junction
Box
Model 4193 Glass Installation
Model 4193 only: install the six pieces of
glass by sliding them down as shown. The glass panels should rest upon the corner guides on each side, and against the rubber bumpers at the bottom.
Note: As with any glass, handle with care.
Corner Guides
Rubber Bumpers
5
595-5770-01
TESTING
Turn on the circuit breaker and light
switch.
The detector is less sensitive to motion directly towards it and more sensitive to across motion.
Sensor
Motion
Least Sensitive Most Sensitive
Walk through the coverage area noting
where you are when the lights turn on.
If you need to change the sensitivity,
temporarily remove the fixture and make the adjustment. Too much sensitivity may increase false triggering.
Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5 or 10 minutes).
Set the amount of time after dusk you
want the lights on accent level.
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 30 ft. (9.1 m)
[varies with surrounding
temperature].
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . Up to 100 Watt
Maximum
Incandescent, Up
to (3) 60 Watt
Maximum
Candelabra.
Sensor Capacity . . . . . Up to 360 Watt (3.0
A.) Maximum Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and
MANUAL MODE
Time Delay . . . . . . . . . 1 , 5, 10 minutes
Dual Brite® timer . . . . . 3, 6 hrs, Dusk-to-
Dawn The Hampton Bay Lighting Company re-
serves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
NOTE: Sensor has a 1 1/2 minute warm up
period before it will detect motion. When first turned on, wait 1 1/2 minutes.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
• Objects that change temperature rapidly,
such as heating vents and air condition- ers. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the
control.
Nearby large, light-colored objects
reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
30 ft.
(9.1 m)
Maximum Range Maximum
Coverage Angle
6 ft.
(1.8 m)
180°
Motion
Switch the on-time to TEST position and
Dual Brite® switch to the OFF position.
6
595-5770-01
SYMPTOM Light comes
on for no ap­parent reason.
Light stays on continu­ously.
Light flashes on and off.
POSSIBLE CAUSE
1. Light Control may be sens­ing small animals or auto­mobile traffic
(Reduce sen-
sitivity)
.
1. The sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface.
(Reduce sensitivity.)
1. Light Control is in the Test mode and warming up.
(Flashing is normal under these conditions)
.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect
(recheck after dark)
.
5. Incorrect circuit wiring, if this is a new installation.
1. Light Control may be in­stalled in a relatively dark location.
2. Light Control is in Test.
(Set control switch to an ON­TIME position.)
SYMPTOM
Light will not come on.
Light comes on in daylight.
TROUBLESHOOTING GUIDE
If you experience a problem, follow this guide.