WARNING:
If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
918-838
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.hampton-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
11/09/09
WARNING
HOT GLASS
CAUSE BURNS
DO NOT TOUCH
UNTIL COOLED
NEVER
TO TOUCH GLASS
CHILDREN AND ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE GLASS, AND SHOULD
ST AY AWA Y TO AVOID BURNS OR CLOTHING IGNITION.
ALLOW CHILDREN
WILL
GLASS
HAMPTON
®
Direct Vent Freestanding Gas Stove
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Hampton
The H35-2 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood
fi replace at the fl ick of a switch. The model H35-2 has been approved by Warnock Hersey for both safety and effi ciency.
As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years
to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your
Hampton® Stove.
®
Gas Stove by REGENCY FIREPLACE PRODUCTS .
UNIT DIMENSIONS
* Unit shown with optional side shelves.
38-1/4” (972mm)
26-7/8” (683mm)
21” (533mm)
28” (711mm)
25” (835mm)
16-3/4” (425mm)
15-3/8” (391mm)
26-1/4” (667mm)
2Hampton® H35-2 Direct Vent Freestanding Gas Stove
TABLE OF CONTENTS
UNIT DIMENSIONS
Unit Dimensions ............................................................2
SAFETY LABEL
Copy of Safety Label .....................................................4
Pression d'allimentation minimum
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
Dimensions de l’orifi ce
L’altitude
Pression d'allimentation minimum
Pression à la tubulure d'échappement élevée
Pression à la tubulure d'échappement basse
Débit Calorifi que maximum
Débit Calorifi que minimum
Dimensions de l’orifi ce
L’altitude
FACTORY EQUIPPED FOR NATURAL GAS
Model:H35-NG2
Convertible to 30,000
Orifi ce Size
Maximum Input
Minimum Input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas
and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24
CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifi ée est fournie.
This vented gas fi replace heater is not for use with air fi lters. Ne pas utiliser de fi ltre à air avec ce foyer au gaz à é v a c u a t i on .
For use with glass doors certifi ed with the appliance only Pour utilisation uniquement avec les portes en verre certifi ées avec l'appareil
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE
FPI Fireplace Products International Ltd. Delta, BC, Canada Made in Canada/Fabrique au Canada 918-840
Minimum Clearances to Combustibles/Degagement
Minimum De Materiaux Combustibles
Minimum ceiling height from top of unit:36”/914mm
Minimum plafond hauteur en haut de l’appareil:
A 6-1/2”/165mm
B 6”/152mm
Minimum clearance of Vent Terminal to Outside Corner & Inside Corner:
with AstroCap 6"/150mm with Dura-Vent Cap 12"/300mm
This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.
COPY OF SAFETY LABEL
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
4Hampton® H35-2 Direct Vent Freestanding Gas Stove
Left Side Wall
A
Horizontal
Pipe
A
Right Side Wall
NOTE: Hampton® units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
Left Side Wall
A
Vertical
Pipe
A
Right Side Wall
C
E
B
E
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
Hampton® H35-2 Direct Vent Freestanding Gas Stove
5
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The Direct Vent Freestanding Gas Stove must be
installed in accordance with these instructions.
Carefully read all the instructions in this manual
fi rst. Consult the building authority having
jurisdiction to determine the need for a permit
prior to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or property
damage. Failure to follow these
instructions may also void your fi re
insurance and/or warranty.
liner) rigid fl ue and termination cap.
The effi ciency rating of the appliance is a
product thermal effi ciency rating determined
under continuous operating conditions and
was determined independent of any installed
system.
INFORMATION FOR
MOBILE /
MANUFACTURED
HOMES
AFTER FIRST SALE
This Hampton® product has been tested and
listed by ITS Testing Services as a Direct Vent
Wall Furnace to the following standards:
CGA-2.17-M91, and ANSI Z21.88b-2007/CSA
2.33b-2007.
This Direct Vent System Appliance must be
installed in accordance with the manufacturer's
installation instructions and the Manufactured
Home Construction and Safety Standard, Title
24 CFR, Part 3280, or the current Standard
of Fire Safety Criteria for Manufactured
Home Installations, Sites, and Communities
ANSI/NFPA 501A, and with CAN/CSA Z240-MH
Mobile Home Standard in Canada.
This appliance installation must comply with
the manufacturer's installation instructions and
local codes, if any. In the absence of local codes
follow the current National Fuel Gas Code, ANSI
Z223.1 and the current National Electrical Code
ANSI/NFPA 70 in the U.S.A., and the current
CAN/CSA B149.1 Gas Installation Code and
the current Canadian Electrical Code CSA
C22.1 in Canada.
This Hampton® Mobile/Manufactured
Home Listed appliance comes factory
equipped with a means to secure the
unit.
This Hampton® Mobile/Manufactured
Home listed appliance comes equipped
with a dedicated #8 ground lug to which
an 18 gauge copper wire from the steel
chassis ground must be attached.
This appliance may only be installed in
an aftermarket permanently located,
manufactured (USA only )or mobile
home, where not prohibited by local
codes.
This appliance is only for use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other gases,
unless a certifi ed kit is used.
BEFORE YOU ST ART
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
INSTALLATION AND REPAIRS SHOULD
BE DONE BY A QUALIFIED SERVICE
PERSON. THIS APPLIANCE SHOULD BE
INSTALLED, REPAIRED, INSPECTED BEFORE USE AND A T LEAST ANNUALL Y BY
A QUALIFIED SERVICE PERSON. MORE
FREQUENT CLEANING MAY BE REQUIRED
DUE TO EXCESSIVE LINT FROM CARPETING, ETC. IT IS IMPERATIVE THAT THE
CONTROL COMPARTMENT, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERA TURES, THE APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERA TURES, ESPECIALLY
THE FIREPLACE GLASS, AND SHOULD
STA Y A WA Y TO A VOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULL Y SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
1) Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor , or it can be
raised up on a platform to enhance its visual
impact. The appliance may be installed on
carpeting, tile, wood fl ooring or other com-
bustible material, because the appliance's
base extends the full width and depth of the
appliance. The Direct Vent Freestanding
Gas Stove can be installed in a wide variety
of ways and will fi t nearly any room layout.
It may be installed in a recessed position,
framed out into the room, or across a corner.
3) The Direct Vent Freestanding Gas Stove
is approved for alcove installations, which
meet the clearances listed in the "Clearance to Combustibles" section. This unit is
approved for manufactured home installations, see the "Manufactured Mobile Home
Additional Requirements" section and the
"Venting Arrangement" section for the required vent arrangements. If installed into a
manufactured home the unit must be bolted
down to the fl oor.
4) This appliance is Listed for bedroom installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
5) This appliance is Listed for Alcove installations, maintain minimum Alcove clearances
as follows, minimum width of 40" (1016mm),
a maximum depth of 36" (914mm), and
minimum ceiling height of 64" (1626mm)
from fl oor to ceiling.
6) We recommend that you plan your installation on paper using exact measurements
for clearances and fl oor protection before
actually installing this appliance. Have a
qualifi ed building inspector review your plans
before installation.
6Hampton® H35-2 Direct Vent Freestanding Gas Stove
INSTALLATION
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform with
local Canadian Electrical Code.
2) The appliance when installed, must be
electrically grounded in accordance with
local codes, or in the absence of local codes
with the current National Electrical Code,
ANSI/NFPA 70 or CSA C22.1 Canadian
Electrical Code.
3) The appliance should be inspected for
shipping damage before use and serv-
iced annually by a professional service
person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, etc. It is imperative
that control compartments, and circulating
air passageways of the appliance be kept
clean and free from excessive lint from
carpeting.
4) See general construction and assembly
instructions. The appliance and vent should
be enclosed when installed in or passing
through a living area, where children may
come in contact with it.
5) This appliance must be connected to the
specifi ed vent and termination cap to the
outside of the building envelope. Never
vent to another room or inside a building.
Make sure that the vent is fi tted as per the
instructions starting in the "Exterior Vent
Terminal Locations" section.
6) Inspect the venting system annually for
blockage and any signs of deterioration.
7) Venting terminals shall not be recessed into
a wall or siding.
8) Any safety glass removed for servicing
must be replaced prior to operating the appliance.
9) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fi replace.
Emissions from burning wood or gas could
contain chemicals known to the State of California to cause cancer, birth defects or other
reproductive harm.
INSTALLATION
CHECKLIST
1) Locate your appliance. Refer to the following
sections:
Introduction" to "Venting Arrangements"
Section.
2) Install Optional Fan. Refer to the "Optional
Fan Installation" section.
3) Set vent restrictors. Refer to the "Vent Restrictor Position" section.
4) Install venting. Refer to the following sections
where applicable:
a. Check all venting requirements.
See "Venting Introduction" to "Venting
Arrangements" sections.
b. Vertical Termination with Co-linear Flex
System
c. DV Stove Horizontal Vent Kit
d. Dura-Vent Termination Kit.
5) Make gas connections. Refer to the "Gas
Connection" section
Test the pilot. Must be as per diagram in the
"Maintenance Instruction" section.
If converting to Propane, make changes
prior see the "Conversion from Natural Gas
to Propane" section.
6) Test Gas Pressure. Refer to the "Gas Pipe
Pressure Testing" section.
7) Install standard and optional features. Refer
to the following sections where applicable:
a. Brick Panels
b. Log Set Installation
c. Wall Thermostat
d. Remote Control
e. Optional Side Shelves
8) Final check. Refer to the "Final Check" section.
Before leaving this unit with the customer,
the installer must ensure that the appliance is fi ring correctly and operation fully
explained to customer.
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
CLEARANCES TO
COMBUSTIBLES
The clearances listed are MINIMUM distances.
Measure the clearance to both the appliance
and the chimney connector. The farthest
distance is correct if the two clearances do
not coincide.
For example, if the appliance is set as indicated
in one of the fi gures but the connector is too
close, move the stove until the correct clearance
to the connector is obtained.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances.
This unit can be installed on a solid combustible
surface like a wood fl oor. This unit can also be
installed directly on carpeting or vinyl.
Use the minimum clearances shown in the
diagrams below:
H35-NG2 & H35-LP2 Clearances
A Side Wall to Unit 6-1/2" / 165 mm
B Back Wall to Unit 6" / 152 mm
C Vertical Vent Pipe to Back Wall
2" / 50 mm
E Unit Corner to Wall 2" / 50 mm
Unit Top to Alcove Ceiling 36" / 914 mm
Minimum ceiling height is 36" /914 mm from
top of unit.
a. Clearances to combustibles
b. Locating Your Gas Stove
c. For venting requirements, see "Venting
Hampton® H35-2 Direct Vent Freestanding Gas Stove
7
INSTALLATION
LOCATING YOUR
GAS STOVE
When selecting a location for your stove, ensure
that the clearances listed above are met as well
as ensuring that there is adequate accessibility
for servicing and proper operation.
A) Cross Corner
B) Room Divider
C) Island
D) Flat on Wall
E) Flat on Wall Corner
F) Flush with Wall/Alcove
For Vent Termination requirements, see the
"Exterior Vent Terminal Locations" section.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided.
OPTIONAL FAN INSTALLATION
Fan Kit Contains:
Qty. Description
1 Fan Speed Controller with nut, and
knob.
1 Fan Assembly c/w green wire
attached
1 Power cord
1 Plastic locking grommet
1) Remove the Top Control Panel Assembly
by removing the three screws. Diagram 1.
Diagram 1
2) Remove the nylon hole plug from the control
panel.
3) Install the fan speed controller onto the
control panel and secure with nut. Connect
remaining wire harness wires to speed
control. NOTE: Speed control wires must
be in the down position when control panel
is in place.
4) Push black knob onto speed control.
5) Remove the rear access panel on the back
of the stove by removing the 6 screws. Install
the fan onto pins as per Diagram 2.
7) Install locking grommet to power cord and
push through hole in the rear panel and give
a 1/4 turn to secure.
NOTE: When running wires, keep them clear
of valve assembly and tubing to avoid
tangling of wires and valve.
NOTE: Be careful not to cut wires when pass-
ing through holes in the fi rebox.
8) Run green ground wire from fan and connect
to grounding lug.
9) Connect green power cord ground wire to
grounding lug.
10) Run the neutral black wire from power cord
and connect to fan motor.
11) Run the live black wire from power cord and
connect to speed control wire.
12) Connect the white wire of the wire harness
to the fan terminal.
NOTE: Pull excess wire next to fan to
avoid excessive heat from the fi rebox.
13) Ensure all wires are pulled away from fi rebox
to avoid excessive heat and secure with
stick-on wire clip.
3) Appliance must be anchored to the fl oor
with the supplied anchoring methods.
COMBUSTION AND
VENTILA TION AIR
The combustion air from this appliance is drawn
from outside the building through the outer fl ue.
Extra provision for combustion air inside the
room is not required.
8Hampton® H35-2 Direct Vent Freestanding Gas Stove
Diagram 2
NOTE: Do NOT damage, cut or remove
the 3" aluminum air intake pipes.
Hint for pushing fan down onto pins - rub a
bit of dish soap on the pins so the grommets
will slide down more easily. Check to make
sure the fan is seated properly on the pins
- try to move the fan back and forth.
6) Push power cord through hole in the rear
panel 14" - 16" and tie a loose knot in the
cord on the inside to prevent the power cord
from being pulled out. Diagram 2.
14) Re-attach control panel with 3 screws, reversing step 1. Re-attach rear access panel
with 6 screws, reversing step 5.
NOTE: When power cord is plugged in, speed
control is in the ON position and stove is
burning, allow 10 - 15 minutes for the thermodisc (temperature switch) to activate and
turn on the Fan automatically.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.
INSTALLATION
INSTALLATION
PRECAUTIONS
These venting systems are engineered products
that have been designed and tested for use
with the H35-NG2, and H35-LP2. The warranty
will be voided and serious fi re, health or other
safety hazards may result from any of the following actions:
1) Installation of any damaged Direct Vent
component
2) Unauthorized modifi cation of the Direct Vent
System
3) Installation of any component part not
approved by FPI - Fireplace Products
International Ltd.
4) Installation other than as instructed by the
approved rigid pipe manufacturers and FPI
Fireplace Products International Ltd.
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire
hazard. Do not fi ll air spaces with
insulation.
Be sure to check the vent termination clearance
requirements from decks, windows, soffi ts,
gas regulators, air supply inlets and public
walkways as specifi ed in the "Exterior Vent
Terminal Locations" section and in your local
building codes.
The gas appliance and vent system must be
vented directly to the outside of the building,
and never be attached to a chimney serving
a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use
it's own separate vent system. Common vent
systems are prohibited.
VENTING
INTRODUCTION
The Horizontal Termination Kit and the rigid
pipe venting systems, in combination with the
Direct Vent Freestanding Gas Stoves, H35-NG2
and H35-LP2, have been tested and listed as
direct vent heater systems by Warnock Hersey .
These units use the "balanced fl ue" technology
Co-Axial system. The inner liner vents products
of combustion to the outside while the outer pipe
draws outside combustion air into the combustion chamber thereby eliminating the need to
use heated room air for combustion and losing
warm room air up the chimney.
Note: These fl ue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be
vented directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas burning appliance.
Each direct vent gas appliance must use it's own
separate vent system. Common vent systems
are prohibited.
IMPORTANT
Read all instructions carefully before starting
the installation. Failure to follow these instructions may create a fi re or other safety hazard,
and will void the warranty. Be sure to check the
venting and clearance to combustible requirements. Consult your local building codes before
beginning installation.
The location of the termination cap must conform
to the requirements in the "Exterior Vent T erminal
Locations" section.
VENT RESTRICTOR
POSITION
Vent restriction is required for certain venting
installations, see the diagrams in "Venting
Arrangement" section to determine if they are
required for your installation.
To set the Vent restriction as indicated in the
diagrams in the "Venting Arrangement" section,
simply loosen the screws and push the vent
restrictor plate to the correct position. Tighten
the screws.
Horizontal Termination:
Vent Restrictor setting at 36,000 Btu/h
Vertical Termination:
Vent Restrictor setting at 36,000 Btu/h
SAFETY PRECAUTIONS
FOR THE INSTALLER
1) Wear gloves and safety glasses for protec-
tion.
2) Exercise extreme caution when using ladders or on roof tops.
3) Be aware of electrical wiring locations in
walls and ceilings.
Hampton® H35-2 Direct Vent Freestanding Gas Stove
9
INSTALLATION
EXTERIOR VENT TERMINAL LOCATIONS
1
Minimum Clearance Requirements
AClearance above grade, veranda, porch, deck, or balcony12"(30cm)12"(30cm)
BClearance to window or door that may be opened 12"(30cm)9" (23cm)
CClearance to permanently closed window**
DVertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm)
from the center line of the terminal (check with the local code)
EClearance to unventilated soffi t12"(30cm)12"(30cm)
FClearance to outside corner: with AstroCap and Vent Riser Termination Caps 6"(15cm)6"(15cm)
Clearance to outside corner: with all other approved Termination Caps12"(30cm)12"(30cm)
GClearance to inside corner: with AstroCap and Vent Riser Termination Caps 6"(15cm) 6"(15cm)
Clearance to inside corner: with all other approved Termination Caps12"(30cm)12"(30cm)
HClearance to each side of center line extended above meter/regulator assembly 36"(90cm)
JClearance to service regulator vent outlet36"(90cm)*
KClearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance12"(30cm)9" (23cm)
LClearance to a mechanical air supply inlet
#3' (91cm) above if within 10' (3m) horizontally.
MClearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)
NClearance under veranda, porch, deck, or balcony 12"(30cm)
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
┼
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor
Clearance in accordance with local installation codes and the requirements of the gas supplier
*
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
Canada
22"(56cm)22"(56cm)
a
72"(1.8m)36"(90cm)
┼
‡
USA
*
*
*
2
b
10Hampton® H35-2 Direct Vent Freestanding Gas Stove
INSTALLATION
4” X 6-5/8” RIGID PIPE
CROSS REFERENCE CHART ONLY
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
Chimney Conversion Kit A (USA only)46DVA-KCAN/AN/AN/AN/ATM-4CA6
Chimney Conversion Kit B (USA only)46DVA-KCBN/AN/AN/AN/ATM-4CA7
Chimney Conversion Kit C (USA only)46DVA-KCCN/AN/AN/AN/ATM-4CA8
Chimney Conversion Kit Masonry
(USA only)
Wall Firestop46DVA-WFSN/AN/AN/AN/ATM-4TR
Colinear Flex Connectors46DVA-ADFN/AN/AN/AN/AN/A
FPI
946-506/PVent Guard (Optional) for AstroCap946-205Vinyl Siding Shield for Riser Vent Terminal
510-994Rigid Pipe Adaptor (Must use with all rigid piping)946-208/PVent Guard (Optional) for Riser Vent Terminal
640-530/PRiser Vent Terminal946-523/PAstroCap Horizontal Cap
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
0” (0mm)4-7/8” (124mm)13-7/8” (340mm)Simpson Direct Vent Pro: www.duravent.com
Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
4” x 6-5/8” VentingFor specifi c instructions on venting components - visit the
Run (X)Rise (Y)
46DVA-KMCN/AN/AN/AN/AN/A
946-206Vinyl Siding Standoff for AstroCap
manufacturers website listed below.
12Hampton® H35-2 Direct Vent Freestanding Gas Stove
Alternate
Horizontal
Termination
Caps
INSTALLATION
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCapTM and FPI
Riser is acceptable with all systems.
This product has been evaluated by Intertek
for use with Duravent Direct-Vent Pro, Selkirk
Direct-Temp, Ameri Vent Direct venting and
Security Secure Vent systems.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap
American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace
Products International Ltd. Dura-Vent® and Direct Vent Pro are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent Pro,
Hampton® H35-2 Direct Vent Freestanding Gas Stove
13
INSTALLATION
ROTATING 45O ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS
1) Remove all 4 screws that secure
the elbow to the unit using a 1/4"
magnetic nut driver.
Remove all 4 screws
and washers
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below show
all allowable combinations of vertical runs with
horizontal terminations. Maximum one 90O
elbow (two 45o elbows equal one 90o elbow).
All approved caps listed on page 12 - may
be used.
Propane and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
2) Rotate the elbow 180
3) Secure the elbow by securing
it with the 4 screws.
o
VENTING ARRANGEMENTS
Vertical Terminations Systems for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight vertical
and offset to vertical runs with vertical terminations. Maximum two 45o elbows.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Offset to Vertical Terminations
The venting arrangements diagrammed below,
have a min. of 75% (fl ue loss) effi ciency with Fan
Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
NOTE: See "Vent Restrictor Position" section for
installation instructions for the Vent Restrictor
Position.
14Hampton® H35-2 Direct Vent Freestanding Gas Stove