HAMPTON BAY H15-NG10, H15-LP10 Owners & Installation Manual

H15 Direct Vent Gas Fireplace
MODELS: H15-NG10 Natural Gas H15-LP10 Propane
Owners &
Installation Manual
www.hampton-re.com
WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building. Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency or the gas supplier.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-446d
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
04.26.17
2
|
HAMPTON
®
Direct Vent Freestanding Gas Stove
To the New Owner:
Congratulations! You are the owner of a state-of-the-art Hampton® Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The H15-10 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood
replace at the ick of a switch. The model H15-10 has been approved by Warnock Hersey/Intertek for both safety and e󰀩ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your
Hampton® Stove.
2 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
dimensions
|
3
Dimensions
Unit Dimensions with horizontal vent.............................4
Unit Dimensions with vertical vent ................................. 5
Installation
Important Message ......................................................8
Specications ................................................................8
Mobile / Manufactured Homes After First Sale ..............8
Before You Start ............................................................8
General Safety Information............................................9
Installation Checklist ......................................................9
Clearances to Combustibles........................................10
Locating Your Gas Stove ............................................. 10
Manufactured Mobile Home Additional Requirements 10
Combustion and .........................................................10
Ventilation Air ...............................................................10
Accent light bulb install ................................................10
Optional Fan Installation .............................................. 11
Glass Door ..................................................................12
Removal/Installation ....................................................12
Wall Thermostat Installation ........................................12
Venting Introduction .....................................................13
Installation Precautions ...............................................13
Safety Precautions for the Installer..............................13
Vent Restrictor Position ...............................................13
Rotating Elbow ............................................................13
Exterior Vent Terminal Locations ................................. 14
4” x 6-5/8” Rigid Pipe ..................................................15
Cross Reference Chart ................................................15
Rigid Pipe Venting Systems ........................................17
Venting Arrangements .................................................20
Vertical Termination with Co-linear Flex System .........21
DV Stove Horizontal Vent Kit .......................................22
Residential and Manufactured Homes /
Mobile Homes .............................................................24
Minimum Horizontal Termination Installations .............24
Dura-Vent Termination Kit ............................................25
Horizontal terminations ................................................26
Vertical Terminations ...................................................27
Converting Class-A Metal Chimney to Direct Vent
System.........................................................................29
Cathedral Ceilings .......................................................30
High Elevation .............................................................30
Gas Connection ...........................................................30
Aeration Adjustment ....................................................31
Gas Pipe Pressure Testing .......................................... 31
885 S.I.T. Valve Description .........................................31
Conversion from Ng to LP ...........................................32
Log Set Installation ......................................................33
Optional Wall Thermostat ...........................................35
Back up battery............................................................35
Remote/Receiver coding .............................................35
Manual operation(no remote) ......................................35
Final Check..................................................................35
Wiring Diagram Without Thermostat ...........................36
Wiring Diagram With Thermostat ................................37
Lighting Procedure ......................................................38
First Fire ......................................................................38
Operating Instructions
Operating Instructions .................................................38
Lighting Procedure ......................................................39
Shutdown Procedure ...................................................39
Copy of the Lighting Plate Instructions ....................... 40
Normal Operating Sounds of Gas Appliances .............41
Maintenance Instructions.............................................41
Pilot Adjustment ...........................................................41
General Vent ...............................................................42
Maintenance
Maintenance ................................................................42
Log Replacement ........................................................42
Glass Replacement .....................................................42
Fan Maintenance .........................................................42
Safety screen replacement ..........................................43
Accent light bulb replacement .....................................43
Valve assembly Replacement .....................................44
Parts
Main Assembly ............................................................45
Burner & Log Assembly ...............................................46
Warranty
Warranty ......................................................................48
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 3
4
22-7/8"
19-3/8"
24-11/16"
20-11/16"
17-13/16"
19-1/8"
14-1/4
13-5/8"
21-1/4"
19-1/8"
(525mm)
(451mm)
(485mm)
(540mm)
(626mm)
(581mm)
(492mm)
(345mm)
(485mm)
(361mm)
|
dimensions
UNIT DIMENSIONS WITH HORIZONTAL VENT
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
4 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
UNIT DIMENSIONS WITH VERTICAL VENT
dimensions
|
5
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 5
6
Fabriqué au Canada
919-447a
|
safety decal
This is a copy of the label that accompanies each Direct Vent Freestanding Gas Stove. We have printed a copy of the contents here for your review.
®
NOTE: Hampton
units are constantly being im­proved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
DUPLICATE SERIAL NO.
Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION Certified for/Certifi e pour: CANADA and U.S.A.é Tested to: CAN/CGA-2.17-M91(R2009)
4001172
NATURAL GAS STOVE: Model H15-NG10
L
Minimum supply pressure
Model/Modele:
H15-NG10
Manifold pressure High Manifold pressure Low
Maximum Input Minimum Input Orifice size Altitude
PROPANE GAS STOVE: Model H15-LP10
L
Minimum supply pressure
Model/Modele:
H15-LP10
Manifold pressure High Manifold pressure Low
Maximum Input Minimum Input Orifice size Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1. This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. Optional Fan Kit (Part # 382-917) Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA­B149.1 en vigueur. Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles. Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only. À utiliser uniquement avec les portes vitrées certifiées avec l'appareil.
For Use Only with Barrier (Part # 382-005) Follow installation instructions. Utiliser uniquement avec l’écran de sécurité (pièce n°382-005). Suivre les consignes d'installation.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
ANSI Z21.88-2014Conforms to:
CSA 2.33-2014Certified to:
5" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
18,000 Btu/h (5.28 Kw/h) 12,700 Btu/h (3.72 Kw/h) #47 DMS 0-4500 ft/pi (0-1372m)
11" WC/C.E. (2.74 kPa) 10" WC/C.E. (2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
18,000 Btu/h (5.28 Kw/h) 15,500 Btu/h (4.54 Kw/h) #55 DMS 0-4500 ft/pi (610-1372m)
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
APPAREIL FONCTIONNANT AU GAZ NATUREL Modèle H15-NG10
Pression d’alimentation minimum Pression manifold - lev e é é Pression - basse manifold
D bit calorifique maximumé D bit calorifique minimumé Taille de l'orifice Altitude
APPAREIL FONCTIONNANT AU PROPANE Modèle H15-LP10
Pression d'alimentation minimum Pression manifold - lev e é é Pression manifold - basse
D bit calorifique maximumé D bit calorifique minimumé Taille de l'orifice Altitude
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Minimum Clearances to Combustibles /
aux matériaux combustibles
Horizontal
Minimum ceiling height from top of unit:24"/610mm Hateur min plafond depuis le haut de l'appareil: 24"/610mm
A 6" / 150mm B 0" / 0mm
See Manual for details / Voir manuel pour plus de détails
Minimum clearance of Vent Terminal
to Outside Corner & Inside Corner:
with Dura-Vent Cap 12"/300mm
ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE: 115V_60HZ less than/moins de 2 AMP
FPI Fireplace Products International Ltd.
Made in Canada/
301
Serial No./ No de série
301
Dégagements minimaux
Left Side Wall
Pipe
Right Side Wall
with AstroCap 6"/150mm
Delta, BC, Canada
Left Side Wall
Vertical
Pipe
Right Side Wall
C 2" / 50mm E 2" / 50mm
For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back
up in the same room where the gas appliance is installed.
6 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
requirements
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
|
7
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 7
8
|
installation
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having juris­diction to determine the need for a permit prior to starting the installation.
Note: Failure to follow the instructions could
cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void your re insurance and/ or warranty.
Note: These instructions take precedence
over Simpson Dura-Vent instructions.
SPECIFICATIONS
Fuels: H15-NG10 is approved for use with
natural gas.
H15-LP10 is approved for use with
liquefied petroleum gases (propane).
Electrical: 120V A.C. system.
Optional Circulation Fan:
Variable speed, 125/75.
Log Sets: Ceramic fibre, 4 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner
liner) rigid flue and termination cap.
MOBILE / MANUFACTURED HOMES AFTER FIRST SALE
This Hampton® product has been tested and listed by ITS Testing Services as a Direct Vent Room Heater to the following standards: CGA-2.17-M91, and ANSI Z21.88-2014/CSA
2.33-2014.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home In­stallations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes fol­low the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code
ANSI/NFPA 70 in the U.S.A., and the current CAN/ CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This Hampton® Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.
This Hampton® Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 18 gauge copper wire from the steel chassis ground must be attached.
This appliance may only be installed in an aftermarket permanently located, manu­factured (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
BEFORE YOU START
Safe installation and operation of this appliance re­quires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE­CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE­FULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLI­ANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSICAL BARRIERS IS RECOMMEND­ED IF THERE ARE AT RISK INDIVIDUAL IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INSTALLED FOR THE PROTECTION OF CHILDREN AND OTHER AT-RISK INDIVIDUALS
IF THE BARRIER BECOMES DAMAGED, THE BARRIER SHALL BE REPLACED WITH THE MANUFACTURER'S BARRIER FOR THIS APPLIANCE.
ANY SAFETY SCREEN, GUARD, OR BARRIER REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.
8 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
installation
|
9
1) Provide adequate clearances for servicing, proper operation and around the air openings into the combustion chamber.
2) The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or it can be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, tile, wood flooring or other combustible material, because the appliance's base extends the full width and depth of the appliance. The Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.
3) The Direct Vent Freestanding Gas Stove is approved for alcove installations, which meet the clearances listed in the "Clearance to Combustibles" section. This unit is approved for manufactured home installations, see the "Manufactured Mobile Home Additional Re­quirements" and "Rigid Pipe Venting Systems" sections for the required vent arrangements. If installed into a manufactured home the unit must be bolted down to the floor.
4) This appliance is Listed for bedroom instal­lations when used with a Listed Millivolt Ther­mostat. Some areas may have further require­ments, check local codes before installation.
cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.
4) See general construction and assembly in­structions. The appliance and vent should be enclosed when installed in or passing through a living area, where children may come in contact with it.
5) This appliance must be connected to the speci­fied vent and termination cap to the outside of the building envelope.Never vent to another room or inside a building. Make sure that the vent is fitted as per the instructions starting in the "Exterior Vent Terminal Locations" section.
6) Inspect the venting system annually for block­age and any signs of deterioration.
7) Venting terminals shall not be recessed into a wall or siding.
8) Any safety glass removed for servicing must be replaced prior to operating the appliance.
9) To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.
INSTALLATION CHECKLIST
a. Log Set Installation b. Wall Thermostat c. Remote Control
9) Final check. Refer to the "Final Check" section.
Before leaving this unit with the customer, the installer must ensure that the appliance is firing cor­rectly and operation fully explained to customer.
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting or carboning that results in dam­age is not the responsibility of the manufacturer.
5) This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as fol­lows, minimum width of 32-1/2" (825mm), a maximum depth of 36" (914mm), and minimum height of 24" (610mm) from top of unit to ceiling.
6) We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualified building inspector review your plans before installation.
GENERAL SAFETY INFORMATION
1) The appliance installation must conform with local Canadian Electrical Code.
2) The appliance when installed, must be electri­cally grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.
3) The appliance should be inspected for shipping damage before use and serviced annually by a professional service person. More frequent
Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
1) Locate your gas appliance. Refer to the following sections:
a. Locating Your Gas Stove b. Clearances to Combustibles c. "Venting Introduction" to "Exterior Vent
Terminal Locations" sections.
2) Install Optional Fan. Refer to the "Optional Fan Installation" section.
3) Set vent restrictor. Refer to the "Vent Restrictor Position" section.
4) Install venting: Check all venting requirements. See "Venting Introduction" to "Dura-Vent Verti­cal Termination" sections.
5) Make gas connections. Refer to the "Gas Con­nection" section.
If converting to Propane, make changes prior
as instructed in the "Conversion from Natural Gas to Propane" section.
6) Install 3 AAA batteries into Remote transmit­ter and pair with the IFC board (see Remote Control section).
7) Test Gas Pressure. Refer to the "Gas Pipe Pressure Testing" section.
8) Install standard and optional features. Refer to the following sections where applicable:
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 9
10
|
installation
CLEARANCES TO COMBUSTIBLES
The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide.
For example, if the appliance is set as indicated in one of the figures but the connector is too close, move the stove until the correct clearance to the connector is obtained.
This appliance may be installed only with the clearances as shown in the situations pictured.
Do not combine clearances from one type of installation with another in order to achieve closer clearances.
This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl.
Use the minimum clearances shown in the dia­grams below:
H15-NG10 & H15-LP10 Clearances
A Left Side Wall to Unit* 6" / 150 mm
*B Back Wall to Unit 0" / 0 mm
C Vertical Vent Pipe to Back Wall
2" / 50 mm
E Unit Corner to Wall 2" / 50 mm
Unit Top to Alcove Ceiling 24" / 610 mm
Minimum ceiling height is 24" /610 mm from top
of unit.
*IMPORTANT
It is recommended that unit is moved away from
the wall, if installing the blower option, so the fan
can be easily installed and/or serviced.
LOCATING YOUR
GAS STOVE
When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation. A) Cross Corner
* 12' max. only if vertical height is achieved.
B) Room Divider C) Island D) Flat on Wall E) Flat on Wall Corner F) Flush with Wall/Alcove
For Vent Termination requirements, see the "Exterior Vent Terminal Locations" section.
MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS
1) Ensure that structural members are not cut or weakened during installation.
2) Ensure proper grounding using the #8 ground lug provided.
3) Appliance must be anchored to the floor with the supplied anchoring methods.
ACCENT LIGHT BULB INSTALL
Accent light bulb is packed in the manual pack.
1. Lift off cast top and place on a soft surface.
2. Loosen bolts securing cast front–slide light as-
sembly bracket upward to release.
3. Remove one (1) screw to remove bulb housing.
10 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
COMBUSTION AND
VENTILATION AIR
The combustion air from this appliance is drawn from outside the building through the outer flue.
Extra provision for combustion air inside the room is not required.
Lift light assy bracket o bolts to install
bulb
Remove one screw in location shown
4. Install bulb.
Note: Oils from hands will shorten the life of the bulbs,
do not handle bulbs with bare hands.
5. Reverse steps.
H15
OPTIONAL FAN INSTALLATION
Lift Rear Panel o of the 2 top bolts.
bolt
1. Remove the rear access panel on the back of
the stove by removing 2 bolts at the bottom of the panel. Lift panel up and away to remove.
2. Place a grommet on wiring from fan to be plugged
into the receiver.
3. Remove left side access panel (when
facing front) by removing one screw.
4. Undo wire clip to release red and black
fan wires. Remove cap ends from the
wire spades and plug in fan wires - black to black and red to red.
5. Tuck the fan assembly in behind the legs
as shown. On either side of the unit there will be slits located on the body of the stove. Slide the fan up into the slits until the mounting holes line up with the holes located on the fan assembly. Secure with one screw per side (leave right side screw loose).
6. Eliminate any slack from fan wire by pulling into the unit and securing with wire clip.
7. Tighten screw on right side.
8. Reinstall back access panel.
9. Plug the fan into the nearest outlet
10. To remove fan - reverse steps.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged (grounding) plug for your protec­tion against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
Cap ends
Thermostat (Optional)
(Millivolt)
OPTIONAL FAN INSTALLATION
installation
|
11
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 11
12
|
installation
GLASS FRONT
REMOVAL / INSTALLATION
1. Turn off stove and allow to return to room tem­perature.
2. Lift off cast top and place on a soft surface.
3. Remove 2 bolts and lift off cast front - place front
carefully on a soft surface.
5. Lift both latches securing glass door and remove door.
6. To reinstall–reverse steps.
WALL THERMOSTAT INSTALLATION
1. Open the front panel and remove the cover plate by removing two screws.
2. Disconnect one of the wires from the switch as shown, connect this wire to the thermostat.
4. Slide the light assembly bracket out of the way.
3. Ensure switch is set to <ON> position.
4. Reinstall front panel.
12 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
installation
|
13
VENTING INTRODUCTION
The Horizontal Termination Kit and the Simpson Dura-Vent Direct Vent venting systems, in com­bination with the Direct Vent Freestanding Gas Stoves, H15-NG10, and H15-LP10, have been tested and listed as direct vent heater systems by Warnock Hersey.
These units use the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
Note: These ue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
IMPORTANT
Read all instructions carefully before starting the installation. Failure to follow these instructions may create a fire or other safety hazard, and will void the warranty. Be sure to check the venting and clear­ance to combustible requirements. Consult your local building codes before beginning installation.
The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" section.
INSTALLATION PRECAUTIONS
These venting systems are engineered products that have been designed and tested for use with the H15-NG10, and H15-LP10. The warranty will be voided and serious fire, health or other safety hazards may result from any of the following actions:
1) Installation of any damaged Rigid Pipe com­ponent.
2) Unauthorized modification of any Rigid Pipe System.
3) Installation other than as instructed by Simpson Dura-Vent and FPI Fireplace Products Interna­tional Ltd.
Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a re hazard. Do not ll air spaces with insulation.
Be sure to check the vent termination clearance requirements from decks, windows, soffits, gas regulators, air supply inlets and public walkways as specified in the "Exterior Vent Terminal Locations" section and in your local building codes.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance.
Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
SAFETY PRECAUTIONS FOR THE INSTALLER
1) Wear gloves and safety glasses for protec­tion.
2) Exercise extreme caution when using lad­ders or on roof tops.
3) Be aware of electrical wiring locations in walls and ceilings.
VENT RESTRICTOR
POSITION
To set the Vent restriction as indicated in the Venting Arrangement diagrams in the "Rigid Pipe Venting System" section, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws. This will be located inside the firebox.
ROTATING ELBOW
1) Remove top casting.
2) Remove all 4 screws that secure
the elbow to the unit using a 1/4" magnetic nut driver.
Remove all 4 screws
and washers
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 13
3) Rotate the elbow 180
4) Secure the elbow by securing
it with the 4 screws.
o
14
|
installation
EXTERIOR VENT TERMINAL LOCATIONS
1
Minimum Clearance Requirements
A
Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm)
B
Clearance to window or door that may be opened 12"(30cm) 9" (23cm)
C
Clearance to permanently closed window * *
D
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal (check with the local code)
E
Clearance to unventilated soffit 12"(30cm) 12"(30cm)
F
Clearance to outside corner: with AstroCap and Vent Riser Termination Cap 6"(15cm) 6"(15cm)
Clearance to outside corner: with all other approved Termination Caps. 12"(30cm) 12"(30cm)
G
Clearance to inside corner: with AstroCap and Vent Riser Termination Cap 6"(15cm) 6"(15cm)
Clearance to inside corner: with all other approved Termination Caps 12"(30cm) 12"(30cm)
H
Clearance to each side of center line extended above meter/regulator assembly 36"(90cm)
J
Clearance to service regulator vent outlet 36"(90cm) *
K
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(30cm) 9" (23cm)
L
Clearance to a mechanical air supply inlet #3' (91cm) above if within 10' (3m) horizontally.
M
Clearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)
N
Clearance under veranda, porch, deck, or balcony 12"(30cm)
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Clearance in accordance with local installation codes and the requirements of the gas supplier
*
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
Canada
22"(56cm) 22"(56cm)
a
72"(1.8m) 36"(90cm)
USA
*
*
*
2
b
14 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
installation
4” X 6-5/8RIGID PIPE CROSS REFERENCE CHART
Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
|
15
Description
6” Pipe Length-Galvanized 46DVA-06 4DT-6 N/A 4D6 SV4L6 TC-4DL6 VDV-0406
6” Pipe Length-Black 46DVA-06B 4DT-6B N/A 4D6B SV4LB6 TC-4DL6B VDVB-0406
7” Pipe Length-Galvanized N/A N/A 4D7 N/A N/A N/A N/A
7” Pipe Length-Black N/A N/A 4D7B N/A N/A N/A N/A
9” Pipe Length-Galvanized 46DVA-09 4DT-9 N/A N/A N/A TC-4DL9 VDV-0409
9” Pipe Length-Black 46DVA-09B 4DT-9B N/A N/A N/A TC-4DL9B VDVB-0409
12” Pipe Length-Galvanized 46DVA-12 4DT-12 4D12 4D12 SV4L12 TC-4DL1 VDV-0412
12” Pipe Length-Black 46DVA-12B 4DT-12B 4D12B 4D12B SV4LB12 TC-4DL1B VDVB-0412
18” Pipe Length-Galvanized 46DVA-18 4DT-18 4D18 4D18 SV4LA TC-4DL18 VDV-0418
18” Pipe Length-Black 46DVA-18B 4DT-18B 4D18B 4D18B SV4LA TC-4DL18B VDVB-0418
24” Pipe Length-Galvanized 46DVA-24 4DT-24 4D24 4D24 SV4L24 TC-4DL2 VDV-0424
24” Pipe Length-Black 46DVA-24B 4DT-24B 4D24B 4D24B SV4LB24 TC-4DL2B VDVB-0424
36” Pipe Length-Galvanized 46DVA-36 4DT-36 4D36 4D36 SV4L36 TC-4DL3 VDV-0436
36” Pipe Length-Black 46DVA-36B 4DT-36B 4D36B 4D36B SV4LB36 TC-4DL3B VDVCB-0436
48” Pipe Length-Galvanized 46DVA-48 4DT-48 4D48 4D48 SV4L48 TC-4DL4 VDV-0448
48” Pipe Length-Black 46DVA-48B 4DT-48B 4D48B 4D48B SV4LB48 TC-4DL4B VDVB-0448
60” Pipe Length-Galvanized 46DVA-60 4DT-60 N/A N/A N/A N/A N/A
60” Pipe Length-Black 46DVA-60B 4DT-60B N/A N/A N/A N/A N/A
Adjustable Length 3”-10”-Galvanized N/A N/A N/A 4DAL N/A TC-4DLT N/A
Adjustable Length 3”-10”-Black N/A N/A N/A 4DALB N/A TC-4DLTB N/A
Adjustable Length 7”-Galvanized N/A N/A 4D7A N/A N/A N/A N/A
Adjustable Length 7”-Black N/A N/A 4D7AB N/A N/A N/A N/A
Extension Pipe 8-1/2”-Galvanized 46DVA-08A N/A N/A N/A N/A N/A N/A
Extension Pipe 8-1/2”-Black 46DVA-08AB N/A N/A N/A N/A N/A N/A
Adjustable Length 12”-Galvanized N/A N/A 4D12A N/A SV4LA12 TC-4dLSI N/A
Adjustable Length 12”-Black N/A N/A 4D12A N/A SV4LBA12 TC-4dLSIB N/A
Extension Pipe 16”-Galvanized 46DVA-16A N/A N/A N/A N/A N/A N/A
Extension Pipe 16”-Black 46DVA-16AB N/A N/A N/A N/A N/A N/A
Simpson
Direct Vent Pro
®
Selkirk
Direct Temp™
American Metal Products®
Amerivent Direct
Metal-Fab™
Sure Seal
Security
Secure- Vent®
ICC Excel
Direct
Olympia Ventis DV*
45º Elbow-Galvanized 46DVA-E45 4DT-EL45 4D45L N/A N/A TE-4DE45 VDV-EL0445
45º Elbow-Black 46DVA-E45B 4DT-EL45B 4DT-EL45B N/A N/A TE-4DE45B VDVB-EL0445
45º Elbow Swivel-Galvanized See 46DVA-E45 N/A N/A 4D45L SV4E45 N/A N/A
45º Elbow Swivel-Black See 46DVA-E45B N/A N/A 4D45LB SV4EB45 N/A N/A
90º Elbow-Galvanized 46DVA-E90 4DT-EL90S 4DT-EL90S N/A N/A TE-4DE90 VDV-EL0445
90º Elbow-Black 46DVA-E90B 4DT-EL90SB 4DT-EL90SB N/A SV4EBR90-1 TE-4DE90B VDVB-EL0445
90º Elbow, Swivel-Galvanized See 46DVA-E90 N/A N/A 4D90L SV4E90-1 N/A N/A
90º Elbow, Swivel-Black See 46DVA-E90B N/A N/A 4D90LB SV4EB90-1 N/A N/A
90º Starter Elbow, Swivel-Galvanized
Adaptor* N/A N/A N/A 4D90L N/A N/A VDV- UAA04
Ceiling Support N/A 4DT-CS 4DSP 4DFSP SV4SD TM4-RDS VDV-SCR04
Cathedral Support Box 46DVA-CS 4DT-CSS 4DRSB 4DRS SV4CSB TM4-SDS VDV-CSS04
Wall Support/Band 46DVA-WS 4DT-WS/B 4DWS 4DWS SV4BM TM-SWS VDV-WS04
Offset Support46
Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM N/A VDV-WPT04
Wal
l Thimble Support/Ceiling Support 46DVA-DC N/A N/A N/A SV4PF N/A N/A
Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS VDV-FS04
Tr im Plate-Black N/A 4DT-TP 4DFPB 4DcP SV4LA TM-4TP VDV-WTC04
N/A N/A N/A 4D90A N/A N/A N/A
DVA-ES - N/A
from FPI
4DT-OS N/A N/A SV4SU TM-SOS N/A
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 15
16
|
installation
Description
Attic Insulation Shield 12” 46DVA-IS
Attic Insulation Shield - Cold Climates 36”
Basic Horizontal Termination Kit (A) Disc. 4DT-HKA 4DHTK2 4DHTKA SV-SHK TM4-HTK VDV-KW04
Horizontal Termination Kit (B) 46DVA-KHA
Ver tical Termination Kit Disc. 4DT-VKC 4DHTK 4DHTK SV-FK N/A N/A
High Wind Vertical Cap 46DVA-VCH N/A N/A N/A N/A TM-4VT VDV-VCHW04
High Wind Horizontal Cap 46DVA-HC N/A N/A N/A N/A TM-4DHT N/A
Horizontal Square Termination Cap 46DVA-HC 4DT-HHC 4DHC 4DHT SV4CHC-1 TM-4HT VDV-HC04
Ver tical Termination Cap 46DVA-VC 4DT-HVC 4DVC 4DVT SV4CGV-1 N/A N/A
Storm Collar 46DVA-08A 4DT-SC 4DSC 4DSC SV4FC TM-SC VDV-SC04
Adjustable Flashing 0/12-6/12 46DVA-F6 4DT-ST14 4D12S 4DST14 SV4STC14 TF-4FAVDV-F0406
Adjustable Flashing 6/12-12/12 46DVA-F12 4DT-ST36 4D36S 4DST36 SV4STC36 TF-4FB VDV-SSO
Vinyl Siding Standoff 46DVA-VSS 4DT-VS N/A 4DVS SV4VS TM-VSS N/A
Vinyl Siding Shield Plate N/A 4DT-VSP N/A N/A SV4VS N/A N/A
Snorkel Termination 14” 46DVA-SNK14 N/A N/A N/A N/A TM-4ST14 N/A
Snorkel Termination 36” N/A N/A N/A N/A N/A TM-4ST36 N/A
Restrictor Disk N/A N/A N/A N/A N/A TM-4DS N/A
Extended Vertical Te rmination Cap N/A N/A N/A N/A N/A N/A N/A
Chimney Conversion Kit A (USA only) 46DVA-KCA N/A N/A N/A N/A TM-4CA6 N/A
Chimney Conversion Kit B (USA only) 46DVA-KCB N/A N/A N/A N/A TM-4CA7 N/A
Chimney Conversion Kit C (USA only)
Wall Firestop 46DVA-WFS N/A N/A N/A N/A TM-4TR VDV-FS04
Colinear Flex Connectors 46DVA-ADF N/A N/A N/A N/A N/A N/A
Simpson
Direct Vent Pro
N/A@ FPI
N/A N/A 4DAIS12 N/A N/A TM-4AS N/A
(Changed Components)
46DVA-KCC N/A N/A N/A N/A TM-4CA8 N/A
Selkirk
®
Direct Temp™
N/A 4DAIS12 N/A SV4RSA N/A VDV-AIS04
4DT-HKB 4DHTK1 4DHTKB SV-HK TM4-HTK VDV-K04
American Metal Products®
Amerivent Direct
Metal-Fab™
Sure Seal
Security
Secure- Vent®
ICC Excel
Direct
Olympia Ventis DV*
* Olympia Ventis DV applicable for the following units only: B36XTE, B36XTCE, B41XTE, B41XTCE, P36, P36E
FPI
946-506/P Vent Guard (Optional) for AstroCap 946-205 Vinyl Siding Shield for Riser Vent Te rminal
510-994 Rigid Pipe Adaptor (Must use with all rigid piping) 946-208/P Vent Guard (Optional) for Riser Vent Terminal
640-530/P Riser Vent Terminal 946-523/P AstroCap Horizontal Cap
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
0” (0mm) 4-7/8” (124mm) 13-7/8” (340mm) Simpson Direct Vent Pro: www.duravent.com
6” (152mm) 8” (203mm) 16-1/2” (419mm) Selkirk Direct-Temp: www.selkirkcorp.com
9” (229mm) 10-1/8” (257mm) 18-5/8” (473mm) American Metal Products: www.amer icanmetalproducts.com
12” (305mm) 12-1/4” (311mm) 20-3/4” (527mm) Metal-Fab Sure Seal: www.mtlfab.com
24” (610mm) 20-5/8” (524mm) 29-1/8” (740mm) Security Secure Vent: www.securitychimneys.com
36” (914mm) 29” (737mm) 37-1/2” (953mm) Industrial Chimney Company: www.icc-rsf.com
48” (1219mm) 37-7/16” (951mm) 45-15/16” (1167mm)
4” x 6-5/8” Venting For specifi c instructions on venting components - visit the
Run (X) Rise (Y)
16 | Hampton® H15-10 Direct Vent Freestanding Gas Stove
946-206 Vinyl Siding Standoff for AstroCap
manufacturers website listed below.
Pipe Length
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
24" Pipe
Length
Adj.Pipe Length
11"-14-5/8"
90 Elbow
o
Horizontal
Termination
Cap
Wall Thimble
Vinyl Siding
Standoff (Optional)
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
Alternate
Horizontal Termination
Caps
Max.
installation
|
17
WARNING:
Do not combine venting components from different venting systems.
However use of the the AstroCapTM and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct venting and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.
The FPI AstroCap American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
TM
and FPI Riser Vent terminal are cer tified for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent,
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Hampton® H15-10 Direct Vent Freestanding Gas Stove | 17