Safety Rules - Read and Save These Instructions
WARNING
WARNING
To reduce t he risk of ele ctric shoc k, insure el ectricit y has been
turn ed off at the circ uit breake r or fuse box be fore begin ning.
All wir ing must be in a ccordanc e with the Nat ional Elec trical
Code “ ANSI/NFPA 70-199 9” and local e lectrica l codes . Ele ctric al
inst allation s hould be per formed by a qu alified li censed
elec trician.
WARNING: To reduce the r isk of elect rical shoc k or fire, do no t
use th is fan with an y solid-st ate fan spee d control de vice. It wil l
perm anently da mage the ele ctronic ci rcuitry.
CAUT ION: To reduce th e risk of pers onal injur y, use onl y the
scre ws provide d with the out let box.
The ou tlet box and s upport str ucture mus t be securel y mounted an d
capa ble of relia bly suppor ting a minim um of 35 pound s. Use only
UL Listed ou tlet boxes m arked “FOR FAN SU PPORT”.
The fa n must be moun ted with a min imum of 7 feet c learance f rom
the tr ailing edg e of the blade s to the floor.
Avoid pla cing objec ts in path of th e blades.
To avoid pe rsonal inj ury or damag e to the fan and o ther items , be
caut ious when wo rking arou nd or cleani ng the fan.
Do not u se water or de tergents whe n cleaning t he fan or fan bl ades.
A dry dus t cloth or lig htly dampe ned cloth wi ll be suitab le for most
clea ning.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Afte r making ele ctrical co nnection s, spliced c onductor s should be
turn ed upward an d pushed car efully up in to outlet bo x. The wires
shou ld be spread a part with th e grounded c onductor a nd the
equi pment-gr ounding co nductor on o ne side of the o utlet box an d
ungr ounded con ductor on th e other side o f the outlet b ox.
All se t screws mus t be checked a nd retight ened where n ecessary
befo re install ation.
10.
11.
TO RE DUCE THE RISK O F PE RSONAL INJ URY, DO NO T BEND THE
BLADE ARM S (A LSO REFER RE D TO AS FLANG ES ), WHE N
INSTAL LING THE BRACKE TS , BALANCI NG THE B LADES OR
CLEANI NG THE FAN. DO NO T INSE RT FORE IG N OBJECTS I N –
BETWEE N RO TATING FAN BLADES.
TO RE DUCE THE RISK O F FI RE, ELECT RI C SHOCK OR PE RS ONAL
INJURY, MOUNT FAN TO O UT LET BO X MARKED ACC EP TABLE F OR
FAN SU PPORT WITH THE SCRE WS P ROVID ED WIT H THE OU TL ET
BOX.
1