Questions, problems, missing parts? Before returning to the store,
call Hampton Bay Customer Service
8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST Saturday
1-855-HD-HAMPTON
HAMPTONBAY.COM
Visual instruction of how to install this fan:
Visit www.homedepot.com and enter either the Item or Model number to find
this fan and click the link of visual instruction in the product overview section.
THANK YOU
Table of Contents
Table of Contents ..........................................................
Safety Information .........................................................
Service Parts ...............................................................
18
18
18
19
19
21
READ AND SAVE THESE INSTRUCTIONS
2
Safety Information
1. To reduce the risk of electric shock, ensure electricity has
been turned off at the circuit breaker or fuse box before
beginning.
2. All wiring must be in accordance with the National Electrical
Code “ANSI/NFPA 70-1999” and local electrical codes.
Electrical installation should be performed by a qualified
licensed electrician.
3. The outlet box and support structure must be securely
mounted and capable of reliably supporting a minimum of 35
lbs (15.9 kg) or less. Use only UL-listed outlet boxes marked
“FOR FAN SUPPORT.”
4. The fan must be mounted with a minimum of 7 ft (2.1m)
clearance from the trailing edge of the blades to the floor.
5. Avoid placing objects in the path of the blades.
6. To avoid personal injury or damage to the fan and other
items, be cautious when working around or cleaning the fan.
7. Do not use water or detergents when cleaning the fan or fan
blades. A dry dust cloth or lightly dampened cloth will be
suitable for most cleaning.
8. After making electrical connections, spliced conductors
should be turned upward and pushed carefully up into the
outlet box. The wires should be spread apart with the
grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on
the other side of the outlet box.
9. All setscrews must be checked and retightened where
necessary before installation.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
WARNING: To reduce the risk of electrical shock or fire, do
not use this fan with any solid-state fan speed control device.
It will permanently damage the electronic circuitry.
WARNING: To reduce the risk of personal injury, do not
bend the blade arms (also referred to as flanges), when
installing the brackets, balancing the blades or cleaning the
fan.
WARNING: Do not insert foreign objects between rotating
fan blades.
WARNING:To reduce the risk of fire, electric shock or
personal injury, mount the fan to the outlet box marked
acceptable for fan support with the screws provided with the
outlet box.
10. This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.
Warning: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void
the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications.
CAUTION: To reduce the risk of personal injury, use only
the screws provided with the outlet box.
3
HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
SPECIFICATIONS
TOOLS REQUIRED
Warranty
Fan size
Watts
RPM
CFM
Speed
Volts
Amps
N.W.
G.W.
C.F.
We warrant the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a period
of lifetime after the date of purchase by the original purchaser. We also warrant that all other fan parts, excluding any glass or acrylic
blades, to be free from defects in workmanship and material at the time of shipment from the factory for a period of three years after the
date of purchase by the original purchaser. We agree to correct such defects without charge or at our option replace with a comparable or
superior model if the product is returned. To obtain warranty service, you must present a copy of the receipt as proof of purchase. All
costs of removing and reinstalling the product are your responsibility. Damage to any part such as by accident, misuse, improper installation or by affixing any accessories, is not covered by this warranty. Because of varying climatic conditions this warranty does not cover
any changes in brass finish, including rusting, pitting, corroding, tarnishing or peeling. Brass finishes of this type give their longest useful
life when protected from varying weather conditions. A certain amount of “wobble” is normal and should not be considered a defect.
Servicing performed by unauthorized persons shall render the warranty invalid. There is no other express warranty. We hereby disclaim
any and all warranties, including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by
law. The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty.
Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. The retailer shall
not be liable for incidental, consequential, or special damages arising out of or in connection with product use or performance except as
may otherwise be accorded by law. Some states do not allow the exclusion of incidental or consequential damages, so the above
exclusion or limitation may not apply to you. This warranty gives specific legal rights, and you may also have other rights which vary from
state to state. This warranty supersedes all prior warranties. Shipping costs for any return of product as part of a claim on the warranty
must be paid by the customer.
Contact the Customer Service Team at 1-855-HD-HAMPTON or visit www.hamptonbay.com.
Pre-InstallationPre-Installation
SPECIFICATIONS
Fan size
54 in.
NOTE: These are approximate measures. They do not
include amps and wattage used by the light kit.
TOOLS REQUIRED
Phillips
screwdriver
Speed
Low (Speed 4)
Medium (Speed 2)
High (Speed 1)
Volts
120
Flat blade
screwdriver
Amps
0.06
0.21
0.46
Watts
2.06
12.62
31.28
RPM
52
120
154
Step
ladder
CFM
1746
4076
5246
7.5 kg
(16.5 lbs.)
Wire
stripper
N.W.
G.W.
9.35 kg
(20.57 lbs.)
C.F.
2.67 cu. ft.
Electrical
tape
4
Pre-Installation (continued)
HARDWARE INCLUDED
Part
Description
Quantity
HARDWARE INCLUDED
NOTE: Hardware shown to actual size unless noted
otherwise in the table below.
AA
BB
CC
DD
EE
FF
GG
HH
II
JJ
KK
LL
MM
NN
OO
Part
AA
BB
CC
DD
EE
FF
GG
HH
II
JJ
KK
LL
MM
NN
OO
Description
Plastic wire nut (not to scale)
Canopy mounting screw with lock washer (preassembled)
Clevis pin (preassembled)
Cotter pin (preassembled)
Collar setscrew (preassembled)
Collar mounting screw with lock washer (preassembled)
Blade arm screw with lock washer (preassembled)
Light kit mounting plate screw (preassembled)
Light kit mounting screw (preassembled)
Metal nut (preassembled)
Glass cap (preassembled)
Decorative nut (preassembled)
9.5 Watt LED bulb (not to scale)
Pull chain and fob (not to scale)
Plastic plug (not to scale)
5HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
Quantity
5
4
1
1
2
6
10
3
3
1
1
1
2
2
1
PACKAGE CONTENTS
Pre-Installation (continued)
Part
Description
Quantity
Part
Quantity
Description
PACKAGE CONTENTS
A
C
D
E
F
G
H
B
I
J
Part
A
B
C
D
E
F
G
K
L
M
Description
Mounting bracket (preassembled)
Filter (preassembled)
Canopy ring (preassembled)
Canopy
Canopy bottom cover (preassembled)
Hanger ball/downrod assembly
Coupling cover
Quantity
1
1
1
1
1
1
1
Part
H
I
J
K
L
M
Description
Fan motor assembly
Blade
Blade arm
Mounting plate
Light kit
Glass shade
Quantity
1
5
5
1
1
1
6
Pre-Installation (continued)
DUAL MOUNTING INSTRUCTIONS
DUAL MOUNTING INSTRUCTIONS
This ceiling fan is supplied with two types of hanging assemblies: the
standard ceiling installation using the downrod with ball and socket
mounting, and the "close-to-ceiling" mounting. The "close-to-ceiling"
mounting is recommended in rooms with less than 8 ft. ceilings or in
areas where additional space is desired from the floor to the fan blades.
When using the standard downrod installation, the distance from the
ceiling to the bottom of the fan blades will be approximately 12 in. The
"close-to-ceiling" installation reduces the distance from the ceiling to the
bottom of the fan blades to approximately 9 in.
Once you have decided which ceiling installation you will use, refer to the
corresponding sections and procedures during the assembly period.
Where necessary, each section of the instructions will note the different
procedures to follow for the two types of installation.
Standard Ceiling Mounting
Close-to-Ceiling Mounting
7HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
Loading...
+ 15 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.