USE AND CARE GUIDE
INDUSTRIAL 60-INCH CEILING FAN
Item #690-049
Model #26829
Questions, problems, missing parts? Before returning to the store call
Hampton Bay Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday.
1-855-HD-HAMPTON
HAMPTONBAY.COM
THANK YOU
We appreciate the trust and condence you have placed in Hampton Bay through the purchase of this ceiling fan. We strive to continually create
quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
Thank you for choosing Hampton Bay!

Table of Contents
Table of Contents ................................................................ 2
Safety Information ............................................................... 2
Warranty ............................................................................... 3
Pre-Installation .................................................................... 3
Installation ............................................................................ 6
Safety Information
1. All wiring must be in accordance with the National Electrical
Code ANSI/NFPA 70-1999 and local electrical codes. Electrical
installation should be performed by a qualified licensed
electrician.
2. The outlet box and support structure must be securely mounted
and capable of reliably supporting 35 lbs. (15.9kg). Use only UL
Listed outlet boxes marked “Acceptable for Fan Support of 35
lbs. (15.9kg) or less.””
3. The fan must be mounted with a minimum of 10 ft (3 m)
clearance from the trailing edge of the blades to the oor.
4. Do not operate the reversing switch while the fan blades are
in motion. You must turn the fan off and stop the blades before
you reverse the blade direction.
5. Do not place objects in the path of the blades.
6. Electrical diagrams are for reference only.
7. After making electrical connections, spliced conductors should
be turned upward and pushed carefully up into the outlet box.
The wires should be spread apart with the grounded conductor
and the equipment-grounding conductor on one side of the
outlet box.
8. All set screws must be checked and retightened where
necessary before installation.
Assembly .............................................................................. 7
Operation ........................................................................... 12
Care and Cleaning ............................................................. 13
Troubleshooting ................................................................. 13
WARNING: To reduce the risk of personal injury,
do not bend the blade brackets (also referred to as
anges) during assembly or after installation. Do not
insert objects in the path of the blades.
WARNING: To reduce the risk of re or electric
shock, do not use this fan with any solid-state speed
control device.
WARNING: To avoid possible electrical shock,
turn the electricity off at the main fuse box before
wiring. If you feel you do not have enough electrical
wiring knowledge or experience, contact a licensed
electrician.
WARNING: To reduce the risk of shock, this fan must
be installed with a wall-control/switch.
WARNING: To reduce the risk of re, electric shock
or personal injury, mount to outlet box marked
“Acceptable for fan support of 35lbs. (15.9kg) or
less”, and use screws provided with the outlet box.
WARNING: To reduce the risk of re, electric shock or
personal injury, wire only a single wall-control panel/
switch and ceiling fan unit together. Wiring two or
more ceiling fans to any wall-control panel/switch
may cause the circuitry to fail by overheating. Please
do not attempt to defeat this feature of the ceiling
fan system as doing so will void the warranty, both
explicit and implicit stipulations thereof.
CAUTION: To reduce the risk of personal injury,
use only the screws provided with the outlet box.
CAUTION: To avoid personal injury or damage to the fan
and other items, use caution when working around or
cleaning the fan.
2

Warranty
The supplier warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a lifetime after the date of purchase by the original purchaser. The supplier also warrants that all other fan parts, excluding any glass or acrylic blades,
to be free from defects in workmanship and material at the time of shipment from the factory for a period of two years after the date of purchase
by the original purchaser. We agree to correct such defects without charge or at our option replace with a comparable or superior model if the
product is returned. To obtain warranty service, you must present a copy of the receipt as proof of purchase. All costs of removing and reinstalling
the product are your responsibility. Damage to any part such as by accident or misuse or improper installation or by afxing any accessories, is
not covered by this warranty. Because of varying climatic conditions this warranty does not cover any changes in brass nish, including rusting,
pitting, corroding, tarnishing, or peeling. Brass nishes of this type give their longest useful life when protected from varying weather conditions.
A certain amount of “wobble” is normal and should not be considered a defect. Servicing performed by unauthorized persons shall render the
warranty invalid. There is no other express warranty. Hampton Bay hereby disclaims any and all warranties, including but not limited to those
of merchantability and tness for a particular purpose to the extent permitted by law. The duration of any implied warranty which cannot be
disclaimed is limited to the time period as specied in the express warranty. Some states do not allow a limitation on how long an implied warranty lasts, so the above limitation may not apply to you. The retailer shall not be liable for incidental, consequential, or special damages arising
out of or in connection with product use or performance except as may otherwise be accorded by law. Some states do not allow the exclusion of
incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives specic legal rights, and you
may also have other rights which vary from state to state. This warranty supersedes all prior warranties. Shipping costs for any return of product
as part of a claim on the warranty must be paid by the customer.
Contact the Customer Service Team at 1-855-HD-HAMPTON or visit www.HamptonBay.com
Pre-Installation
SPECIFICATIONS
Size Speed Volts Amps
Low
60 in.
Medium 0.58 32 137 4961 155
High 1 0.87 75 211 7990 106
High 2 0.99 109 247 9602 89
NOTE: Measured according to Energy STAR® approved
Solid State test method.
120
TOOLS REQUIRED
Phillips
screwdriver
Step ladder
Power
Use
(WATT)
0.4 15 89 3208 213
RPM
Flat blade
screwdriver
Airow
CFM
Adjustable
wrench
Airow Efciency
(Higher Is Better)
CFM/WATT
Net
Weight
17.64 lbs
(8 kgs)
Electrical
tape
Gross
Weight
19.82 lbs
(8.99 kgs)
Cube Feet
1.66’
Wire
cutter
3
Please contact 1-855-HD-HAMPTON for further assistance.
HAMPTONBAY.COM

Pre-Installation (continued)
HARDWARE INCLUDED
NOTE: Hardware not shown to actual size.
AA
FF
KK LL MM NN
BB
GG HH II JJ
CC
DD EE
Part Description Quantity
AA J wood screw 1
BB Canopy mounting screw 4
CC Canopy mounting lock washer 4
DD Plastic wire connector 6
EE Hanger bolt 1
FF Flat washer 1
GG Hexagonal nut 1
HH Lockwasher 1
Part Description Quantity
II Control mounting screw 2
JJ Control mounting screw 2
KK Lockwasher 6
LL Flat washer 6
MM Screw 6
NN Split pin 1