HPS PowerPlusTM is your
compact economical solution!
HPS Shielded
Transformer
Type 3R Enclosure
or Stainless Steel
Single Phase Specifications
HPS PowerPlusTM is a convenient pre-wired power center
that saves you time, money, and space. HPS
PowerPlusTM combines a pre-wired primary breaker,
secondary power panel, and dry-type shielded
transformer in a Type 3R enclosure. Simply add the
required secondary breaker and you effortlessly have a
power center that is ready for indoor or outdoor use!
Features
• Type 3R indoor/outdoor enclosure
(optional 316 Stainless Steel enclosure available)
• 480 Primary, 120/240 Secondary
• Single Phase, 60 Hz Frequency
• 5, 7.5, 10, 15, 25 kVA available
• Shielded transformer
• 180° insulation class
• 115° temperature rise
• Primary taps: 2 - 5% FCBN
• Meet NEMA, ANSI, & OSHA standards
• 15 year limited warranty on transformer
• 1 year limited warranty on Mini Power Center
Pad-Lockable
Captive Hardware
Applications
• Industrial locations
• Temporary power at construction sites
• Commercial buildings
• Test equipment
• Plant assembly lines
Secondary Main
Breakers
Conduit
Knockouts
Hinged
Removable
Cover
Primary Main
Breaker (included)
(included)
Branch Circuit
Breakers
(not included)
480 Primary 120/240 Secondary 60 Hz
Max. Secondary
kVA
Rating
5 M1PC005LESF Aluminum 8 4 11.250 7.750 31.938 127
7.5 M1PC007LESF Aluminum 8 4 13.875 11.125 31.938 201
10 M1PC010LESF Aluminum 8 4 13.875 11.125 34.188 210
15 M1PC015LESF Aluminum 12 6 15.125 12.500 34.188 291
25 M1PC025LESF Aluminum 20 10 16.250 13.625 41.563 423
5 M1PC005LESF7 Aluminum 8 4 11.250 7.750 31.938 127
7.5 M1PC007LESF7 Aluminum 8 4 13.875 11.125 31.938 201
10 M1PC010LESF7 Aluminum 8 4 13.875 11.125 34.188 210
15 M1PC015LESF7 Aluminum 12 6 15.125 12.500 34.188 291
25 M1PC025LESF7 Aluminum 20 10 16.250 13.625 41.563 423
*Please contact factory for exact number of secondary circuits available.
Catalog
Number
Winding
Material
316 Stainless Steel Enclosure
Circuits
120 V
(1 Pole)
Type 3R Enclosure
*
240 V
(2 Pole)
Overall Dimensions
Width Depth Height
Weight
Lbs.
Transformer: HPS shielded transformers are
encapsulated for general purpose indoor or outdoor
use within a variety of environments. An electrostatic
shield is placed between the primary and secondary
winding and grounded to reduce electrical
interference and to provide additional protection.
Panel Assembly: The HPS PowerPlusTM assembly
comes fully equipped with a primary & secondary
main circuit breaker. It will hold up to 20 1-pole or
10 2-pole, one inch, common trip, duplex secondary
branch circuit breakers and ground fault circuit
breakers. Once you have established your branch
circuit requirements, contact our local distributor to
obtain your branch circuit breakers.
Connections: HPS PowerPlusTM accepts Aluminum or
Copper conductor.
Protection: The transformer is protected by the
primary main breaker, which handles high
interrupting fault conditions. The N.E.C. requires a
secondary breaker to be between the transformer and
the panel.
Approvals:
HPS PowerPlusTM:
Circuit Breaker Part Numbers
Primary
kVA
Breaker
5 ED42B020 Q225 25
7.5 ED42B025 Q235 35
10 ED42B035 Q250 50
15 ED42B050 Q270 70
25 ED42B090 Q2110 110
10,000 Amps RMS Symmetrical Interrupting Capacity.
Circuit Breakers listed above are Siemens part numbers.
Breakers can be purchased from your local HPS Distributor.
Secondary
Breaker
Max. Rating
Secondary
Breaker

5 kVA 7.5 kVA
10 kVA
25 kVA
CANADA
595 Southgate Drive
Guelph, Ontario N1G 3W6
Tel: (519) 822-2441
Fax: (519) 822-9701
Toll Free: (888) 798-8882
15 kVA
Scan this QR code with your smartphone
USA
1100 Lake Street
Baraboo, Wisconsin 53913-2866
Tel: (608) 356-3921
Fax: (608) 355-7623
Toll Free: (866) 705-4684
to view additional information on the
HPS PowerPlusTM.
www.hammondpowersolutions.com
PWRPLS11