Hammond Manufacturing 1447S Catalog Page

1447S Single Door Disconnect Enclosures - NEMA 12, 13
ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex™, Square D
Disconnect
Cutout Detail
Designed to house the following
Wallmount Enclosures
safety disconnect equipment:
ABB Controls flange-mounted
variable depth operating mechanism for disconnect switches and circuit breakers. Also cable version for circuit breakers.
Allen Bradley 1494V variable depth
flange mounted disconnect switches and circuit breaker operators. Will not accept Allen Bradley 1494F disconnect switches, 1494D circuit breaker operators.
C-H Westinghouse C361 flange
mounted variable depth operating mechanism with disconnect switches and C371 flange mounted variable depth operating mechanisms for circuit breakers. Also Flex-Shaft™ handle mechanisms for circuit breakers.
General Electric Type STDA
flange handles and variable depth operating mechanism for disconnect switches and circuit breakers. Also SpectraFlex™ cable operators for circuit breakers.
Siemens I-T-E Max-Flex™ flange
mounted variable depth handles for disconnect switches and circuit breakers.
Square D class 9422 disconnect
switches with flange mounted variable depth operating mechanisms or cable mechanisms and Class 9422 flange-mounted variable depth operating mechanisms or cable mechanisms for circuit breakers. Will not accept Square D Class 9422 bracket­mounted disconnect devices, 9422TG1 or TG2 devices.
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
Standards
UL 508 Type 12, 13
• CSA Type 12, 13
Complies with
NEMA Type 12 and 13
JIC EGP-1-1967
IEC 60529, IP54
• Appropriate components are
• required to maintain these standards.
Construction
Formed 14-gauge steel.
Continuously welded seams.
Larger sizes include door and body stiffeners.
Welded brackets provide for enclosure mounting.
Formed lip on door and enclosure exclude flowing liquids and contaminants.
Cutouts and holes are provided to suit the handle, operating mechanism and door closing mechanism. Continuously hinged doors may be
• removed by pulling the hinge pin. Latch pivots and cover interlock
• brackets are welded to the door. Cover latch bars for door handles
• are provided. Collar studs are provided for
• mounting inner panels.
A removable 12 gauge inner panel is included. Oil resistant gaskets are
• permanently secured and mechanically retained.
A bonding stud is provided on the door and a grounding stud is provided in the enclosure.
A literature pocket is provided.
Note:
Disconnects, operating mechanisms
• and door hardware are not provided with the enclosure, and must be ordered separately from the manufacturer. Enclosures with an "A" dimension
• under 40" require 2 point door closing hardware. Enclosures with an "A" dimension
• 40" or more require 3 point door closing hardware.
Finish
Door and enclosure are
• phosphatized and finished in ANSI 61 gray recoatable powder coating on the outside.
Enclosure interior is finished in white powder coating. Inner panel is finished in white
• powder coating.
Accessories
Additional inner panels...see page 433
• Air conditioners...see page 389
• Blowers...see page 406
• Breather kits...see page 423
• Doorstop kits...see page 447
• Drip shield kits...see page 447
• Enclosure stabilizers...see page 451
• Filter fans...see page 413-414
• Floor stand kits...see page 448
• Heaters...see page 418-420
• Thermostats...see page 421
• Window kits...see page 444
144
Quality Enclosures. Service Excellence.
© Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice
1447S Single Door Disconnect Enclosures - NEMA 12, 13
ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex™, Square D
Disconnect
Wallmount Enclosures
When A= M=
36 9.00 42 9.88 48 11.38 60 14.38
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
Quality Enclosures. Service Excellence.
© Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice
145
1447S Single Door Disconnect Enclosures - NEMA 12, 13
ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex™, Square D
Disconnect
Part No.
1447SA8 1447SB8 1447SC8 1447SD8 1447SE8 1447SF8 1447SG8 1447SH8 1447SJ8 1447SK8 1447SL8 1447SA10 1447SB10 1447SC10 1447SD10 1447SE10 1447SF10
Wallmount Enclosures
1447SG10 1447SH10 1447SJ10 1447SK10 1447SL10 1447SE12 1447SG12 1447SH12 1447SJ12 1447SK12 1447SL12 1447S46L12 1447SG16 1447SK16 1447SL16
2
Center stiffener; N = Not Included I = Included
A B C D E F G
20 21.38 8 17 17 15.38 21.25 51 N 24 21.38 8 21 17 15.38 25.25 60 N 24 25.38 8 21 21 19.38 25.25 71 N 30 21.38 8 27 17 15.38 31.25 74 N 30 25.38 8 27 21 19.38 31.25 87 N 36 25.38 8 33 21 19.38 37.25 98 N 36 31.38 8 33 27 25.38 37.25 121 N 42 31.38 8 39 27 25.38 43.25 135 I 42 37.38 8 39 33 31.38 43.25 154 I 48 37.38 8 45 33 31.38 49.25 172 I 60 37.38 8 57 33 31.38 61.25 248 I 20 21.38 10 17 17 15.38 21.25 52 N 24 21.38 10 21 17 15.38 25.25 63 N 24 25.38 10 21 21 19.38 25.25 71 N 30 21.38 10 27 17 15.38 31.25 80 N 30 25.38 10 27 21 19.38 31.25 90 N 36 25.38 10 33 21 19.38 37.25 100 N 36 31.38 10 33 27 25.38 37.25 126 N 42 31.38 10 39 27 25.38 43.25 143 I 42 37.38 10 39 33 31.38 43.25 193 I 48 37.38 10 45 33 31.38 49.25 180 I 60 37.38 10 57 33 31.38 61.25 255 I 30 25.38 12 27 21 19.38 31.25 100 N 36 31.38 12 33 27 25.38 37.25 130 N 42 31.38 12 39 27 25.38 43.25 150 I 42 37.38 12 39 33 31.38 43.25 200 I 48 37.38 12 45 33 31.38 49.25 220 I 60 37.38 12 57 33 31.38 61.25 265 I 60 37.38 12 57 34.5 31.38 61.25 265 1 36 31.38 16 33 27 25.38 37.25 150 N 48 37.38 16 45 33 31.38 49.25 200 I 60 37.38 16 57 33 31.38 61.25 265 I
Panel Size
Mounting Center
Ship
Wt. lbs
Center
Stiffener
2
146
Space Occupied by Disconnect
Note: "K" = 4.75 when "C" = 8.00 "K" = 7.09 when "C" = 10.00 "K" = 11.62 when "C" = 12.00 "K" = 11.62 when "C" = 16.00 "K" = 18.38 for 1447S46L12 "P" = Wiring Space
Disconnects will occupy space on panel shown by dimensions "K", "L" and "M".
Wiring space "P" is available when disconnect is installed in the enclosure.
*The disconnect information and space occupied tables based on data supplied by disconnect manufacturer’s bulletins. Hammond Manufacturing not responsible for dimensional accuracy.
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
Quality Enclosures. Service Excellence.
© Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice
1447S Single Door Disconnect Enclosures - NEMA 12, 13
Selection Guide
Hammond Series 1447S
ABB Controls
Allen Bradley
Cutler Hammer
General Electric
I-T-E Siemens
Square D
Disconnect Switch
Circuit Breaker
1494V Flange Disconnect Switch
1494V Flange Circuit Breaker
Type C361 Disconnect Switch
Type C371 Circuit Breaker
C-H Westinghouse Circuit Breaker w/FlexShaft
Type STDA Flange Disconnect Switch
Type STDA Flange Circuit Breaker
Circuit Breaker w/SpectraFlex
Max-Flex Flange Disconnect Switch
Max-Flex Flange Circuit Breaker
Class 9422 Disconnect Switch
Class 9422 Circuit Breaker
Class 9422 “T” Disconnect Switch w/ cable mechanism Circuit Breaker w/ cable mechanism
Shaft: 8-12” dp enclosures, use DSFHS-12; 16” dp enclosures, use DSFHS-17
Door Hardware: 2 pt. Latching, use KDH2R; 3 pt. Latching, use KDH3R and FH-3RL
Shaft: 8-12” dp enclosures, use K7FHD-S12; 16” dp enclosures, use K7FHD-S17
Door Hardware: 2 pt. Latching, use FH-DHK; 3 pt. Latching, use FH-DHK and FH-3RL
Handle: Bulletin 1494V-H1 (except for Hammond part # 1447S46L12, use 1494V-H2)
Connecting rod: 8-10” dp enclosures, use 1494V-RA1; 12-16” dp enclosures, use 1494V-RA2
Door Hardware: 2 pt. Latching, use 1494V-L1; 3 pt. Latching, use 1494VL2
Connecting rod: 8-10” dp enclosures, use 1494V-RA1; 12-16” dp enclosures, use 1494V-RA2
Door Hardware: 2 pt. Latching, use 1494V-L1; 3 pt. Latching, use 1494VL2
Door Hardware: 2 pt. Latching, use C361KJ4 or KJ6; 3 pt. Latching,
Handle: 150 amp, use C371H1 or H3; 250-600 amp, use C371H5 or H7
Door Hardware: 2 pt. Latching, use C361KJ4 or KJ6; 3 pt. Latching, use C361KJ4 or KJ6, and C361KR
Door Hardware: 2 pt. Latching, use C361KJ4 or KJ6; 3 pt. Latching, use C361KJ4 or KJ6, and C361KR
Door Hardware: 2 pt. Latching, use TDV-1; 3 pt. Latching, use TDV-1 and TDV-3
Door Hardware: 2 pt. Latching, use TDV-1; 3 pt. Latching, use TDV-1 and TDV-3
Flange Mt. Handle: 150-600 amp, use STDA1; SK1200, use STDA3
Door Hardware: 2 pt. Latching, use TDV-1; 3 pt. Latching, use TDV-1 and TDV-3
Door Hardware: 2 pt. Latching, use DKR2; 3 pt. Latching, use DKR3
Handle: Flange mount FHOH (except for Hammond part # 1447S46L12, use FHOHN)
Door Hardware: 2 pt. Latching, use DKR2; 3 pt. Latching, use DKR3
Door Hardware: 2 pt. Latching, use 9423-M4 or M9; 3 pt. Latching, use 9423-M4 or M9, and 9423-M3
Door Hardware: 2 pt. Latching, use 9423-M4 or M9; 3 pt. Latching, use 9423-M4 or M9, and 9423-M3
Door Hardware: 2 pt. Latching, use 9423-M4; 3 pt. Latching, use 9423-M4 or M9, and 9423-M3
Door Hardware: 2 pt. Latching, use 9423-M4; 3 pt. Latching, use 9423-M4 or M9, and 9423-M3
Flange operated switch (fusible or non-fusible)
Handle: DSFHN-HS12
Circuit breaker: ABB
Operating Mechanism: see ABB chart
Handle: K7FHD-HS12
Disconnect switch and operating mechanism: Bulletin 1494V
(except for Hammond part # 1447S46L12, use 1494V-RB2 (2))
Trailer fuse block kit (if required): Bulletin 1494V
Fuse kit (if required)
Line and load connectors (if required)
Circuit breaker: C-H Westinghouse
Operating mechanism: Bulletin 1494V
Handle: Bulletin 1494V-H11
Disconnect switch and operating mechanism
Handle: C361-H1 or H3
use C361KJ4 or KJ6, and C361KR Circuit breaker: C-H Westinghouse
Operating mechanism
Circuit breaker
Complete Flex-Shaft handle mechanism
Disconnect switch Type QMR or QMW
Handle: STDA1 or STDA2
Fuse kit (if required)
Variable depth operating mechanism
Circuit breaker
Handle: STDA1 or STDA2
Variable depth operating mechanism
Circuit breaker
Breaker mounted mechanism.
Operating cable
Disconnect switch: MCS
Fuse Kit (if required)
Handle: Flange mount FHOHS
Switch operator mechanism
Operating cable (standard 36.0”)
Circuit breaker
Pressure wire connectors
Circuit breaker operator mechanism
Operating cable: 125-600 amp, use 36”; 800 amp, use 48”
Disconnect switch and operating mechanism 9422
Handle: Type A-1
Circuit breaker
Operating mechanism: Class 9422
Handle: Type A-1
Disconnect switch and operating mechanism 9422, Type T
Handle: Type A-1
Cable mechanism: Class 9422 CFT_O - 3, 5, or 10 foot
Circuit breaker: Square D
Handle: Type A-1
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
Disconnect
Wallmount Enclosures
Quality Enclosures. Service Excellence.
© Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice
147
Loading...
+ 9 hidden pages