Ham-Let H-300U SERIES Data Sheet

INTEGRAL-BONNET
NEEDLE VALVES
H-300U SERIES
VALVES & ACTUATORS
FEATURES
Certified for ISO 15848-1:2006(E) Straight and angle pattern Stainless steel and brass construction MAWP 5000 psi (345 bar), MAWT 446°F (230°C) Flow coefficient (Cv) 0.09 to 1.8 Sizes: 1/8" to 3/4" (3mm-12mm) Round plastic, round aluminum, and metal bar handles
MATERIAL OF CONSTRUCTION
No. Component Qty. Material
2 Set Screw 1 St.St.316
3 Packing Bolt 1 St.St.316
4 Belleville Washer 2 St.St.302
5 Gland 2 St.St.316
6 Upper Packing 1 PTFE
7 Bottom Packing 1 PTFE
A Regulating Stem 1 St.St.316 with surface treatment
B V-Stem 1 St.St.316 with surface treatment
8
C Non-Rotatin Stem 1 St.St.316 with surface treatment
D Soft Seat Stem 1 St.St.316 with surface treatment
9 Panel Nut 2 St.St.316
10 Body 1 St.St.316
Variety of stem types
Packing bolt for easy panel mounting, no packing
disassembling is required
Chevron stem packing provides lowest operation torques
Belleville washers to compensate packing wear
Special synthetic, anti-seize stem lubricant for best
resistance to hot media
5
1
2
3
4
6
7
VALVES & ACTUATORS
Packing bolt enables easy mounting with the packing remaining untouched
Belleville washers improve valve sealing, compensate for wear, and reduce the need for packing adjustment.
Chevron packing reduces packing bolt tightening torque, consequentially reducing the Valve operating torque.
Stem diffusion surface hardening provides the best
galling resistance and protection from wear and corrosion.
8
9
10
INTEGRAL-BONNET NEEDLE VALVES H-300U SERIES
236
GENERAL
E
The H-300U Series is an advanced high pressure instrumentation needle valve for
shut-off service, its packing bolt design for easy mounting being the best solution for
instrumentation panels.
This compact valve enables a relatively high level of flow regulation and long-life service.
Special stem surface treatment, based on low temperature carbon diffusion, enables
higher surface hardness with improved wear resistance, resistance to system
contaminations and optimal operational torque.
STANDARD CONFIGURATION DIMENSIONS
Basic Ordering Number
H-300
H-300
H-395
H-300
H-300
H-300
H-310
H-380
H-380
H-395
H-300
H-300
H-300
H-300
H-310
H-380
H-385
H-385
H-395
H-300
H-310
H-310
H-380
H-385
Dimensions are for reference only, and are subject to change without notice.
* Dimensions for metal handle option
Orice
mm (in) S/A
2.0
(0.08)
4.4
(0.172)
6.4
(0.25)
9.5
(0.375)
Cv
Connection Size
Inlet Outlet mm in mm in mm in mm in mm in
3mm LET-LOK®3mm LET-LOK®50.8 2.00 25.4 1.00 25.4 1.00 25.4 1.00 33.4 1.31
0.09
1/8" LET-LOK®1/8" LET-LOK®50.8 2.00 25.4 1.00 25.4 1.00 25.4 1.00 33.4 1.31 1/8" MNPT 1/8" LET-LOK®45.3 1.78 19.9 0.78 25.4 1.00 19.9 0.78 33.4 1.31 1/4" LET-LOK®1/4" LET-LOK®58.8 2.31 29.4 1.16 29.4 1.16 29.4 1.16 37.3 1.47 6mm LET-LOK®6mm LET-LOK®58.8 2.31 29.4 1.16 29.4 1.16 29.4 1.16 37.3 1.47 8mm LET-LOK®8mm LET-LOK®58.8 2.31 29.4 1.16 29.4 1.16 29.4 1.16 37.3 1.47
0.37
1/8" FNPT 1/8" FNPT 1/8" MNPT 1/8" MNPT 1/4" MNPT 1/4" MNPT 1/4" MNPT 1/4" LET-LOK®54.8 2.16 25.4 1.00 29.4 1.16 25.4 1.00 37.3 1.47 3/8" LET-LOK®3/8" LET-LOK®66.0 2.60 33.0 1.30 33.0 1.30 33.0 1.30 49.5 1.95 10mm
C
10mm
LET-LOK®66.4 2.62 33.2 1.31 33.2 1.31 33.2 1.31 49.7 1.96 1/2" LET-LOK®1/2" LET-LOK®71.6 2.82 35.8 1.41 35.8 1.41 35.8 1.41 52.3 2.06 12mm
LET-LOK®12mm
0.73
1/4" FNPT 1/4" FNPT
LET-LOK®71.6 2.82 35.8 1.41 35.8 1.41 35.8 1.41 52.3 2.06
3/8" MNPT 3/8" MNPT 1/4" MNPT 1/4" FNPT 3/8" MNPT 3/8" FNPT 3/8" MNPT 3/8" LET-LOK®61.5 2.42 28.5 1.12 33.0 1.30 28.5 1.12 49.5 1.95 3/4" LET-LOK®3/4" LET-LOK®97.0 3.82 48.5 1.91 48.5 1.91 48.5 1.91 68.5 2.70 3/8" FNPT 3/8" FNPT
1.8
1/2" FNPT 1/2" FNPT 1/2" MNPT 1/2" MNPT 1/2" MNPT 1/2" FNPT 76.2 3.00 38.1 1.50 38.1 1.50
A A1 A2 A3 B C D E F G H T
41.2 1.62 20.6 0.81 20.6 0.81 20.6 0.81 28.5 1.12
50.8 2.00 25.4 1.00 25.4 1.00 25.4 1.00 33.3 1.31
50.8 2.00 25.4 1.00 25.4 1.00 25.4 1.00 33.3 1.31
54.0 2.12 27.0 1.06 27.0 1.06 27.0 1.06 43.5 1.71
57.0 2.24 28.5 1.12 28.5 1.12 28.5 1.12 45.0 1.77
58.5 2.30 31.5 1.24 27.0 1.06 28.5 1.12 43.5 1.71
56.5 2.22 28.5 1.12 28.0 1.10 28.5 1.12 44.5 1.75
76.2 3.00 38.1 1.50 38.1 1.50 38.1 1.50 58.1 2.29
76.2 3.00 38.1 1.50 38.1 1.50 38.1 1.50 58.1 2.29
76.2 3.00 38.1 1.50 38.1 1.50 38.1 1.50 58.1 2.29
38.1 1.50 58.1 2.29
mm
(in)
10.0
(0.39
14.3
(0.56
19.5
(0.77
max
mm
mm
mm
mm
mm
(in)
(in)
(in)
(in)
7.95
35.1
13.0
"
)
(0.31")
(1.38")
50*
(1.97")
16.5
(0.65")
47.8
(1.88")
"
)
65*
(2.56")
20.0
(0.79")
47.8
(1.88")
"
)
65*
(2.56")
(0.51")
20.0
(0.79")
26.0
(1.02")
63.5
(2.50")
56 *
(2.20")
78.4
(3.09")
66.8*
(2.63")
105.6
(4.16")
94*
(3.70")
(in)
15.9
(5/8")
23.8
(15/16")
30.2
(1-3/16")
mm
(in)
10.0
(0.39")
12.0
(0.49")
22.0
(0.87")
VALVES & ACTUATORS
T max PANEL MOUNT THICKNESS
G OPEN
F PANEL
HOLE DRILL
C
A2
D
B
T max
PANEL MOUNT THICKNESS
A3
A1
A
HAM-LET ADVANCED CONTROL TECHNOLOGY
F PANEL HOLE DRILL
A2
G
OPEN
C
D
H
237
STEM OPTIONS
H-300U needle valves are available with a choice of stem tips:
8A Regulating:
Used where some degree of flow control is required.
FLOW DATA:
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
Flow Coefficient (Cv)
0.5
0.4
0.3
0.2
0.1
0
8B V-Stem:
Standard stem tip used for the on/off operation in
FLOW COEFFICIENT VS. HANDLE TURNS
general-purpose liquids and gas service.
8C Non-Rotating Stem:
Typically used in high-cycle applications to extend valve life and prevent stem rotation inside the body tip, a suitable selection for gaseous high pressure applications.
V and Soft-Seat Stem Regulating Stem Non-Rotating Stem
Orifice
Orifice
9.5 mm (0.375")
Orifice
6.4 mm (0.250")
Orifice
4.4 mm (0.172")
Orifice
2.0 mm (0.080")
0 1 2 3 4 5 6 7
9.5 mm (0.375")
Orifice
Orifice
4.4 mm (0.172")
Orifice
2.0 mm (0.080")
6.4 mm (0.250")
Handle Turns
Orifice
8D Soft Seat:
A soft seat tip requires a lower seating torque than a metal stem tip; the best choice for clean gaseous high pressure applications; MAWT is 200°F (93°C).
9.5 mm (0.375")
Orifice
6.4 mm (0.250")
Orifice
4.4 mm (0.172")
Orifice
2.0 mm (0.080")
8 9
VALVES & ACTUATORS
PRESSURE TEMPERATURE RATING
TEMP. (°C)
-51 0 40 90 150 200 260
5500
5000
4500
4000
3500
3000
2500
2000
Pressure (psig)
1500
1000
500
0
-60 32 100 200 300 400 500
TEMP. (°F)
380
345
310
275
240
210
170
140
100
70
35
0
TECHNICAL DATA
The following table contains the temperature and pressure ratings for a standard valve with PTFE packing.
Body
Material
316 St.St.
Brass
* Extreme temperature fluctuations may require packing adjustment.
Notes:
Pressure (bar)
n
The H-300U was designed for high pressure services where moderately
uncontaminated media is used
n
For steam applications, it is recommended to select one of HAM-LET
severe service needle valves
n
For oxygen applications, select the oxygen clean treatment option.
n
For relatively high pressure pure oxygen applications, assure that the selected valve is tested and found to meet the specific application requirements
INTEGRAL-BONNET NEEDLE VALVES H-300U SERIES
238
Stem Type
All St.St. Stems -51°C to 230°C (-60°F to 446°F) 5000 psi
PCTFE -46°C to 93°C (-51°F to 200°F) 5000 psi
Regulating & V-Stem -46°C to 200°C (-51°F to 392°F) 3000 psi
PCTFE -46°C to 93°C (-51°F to 200°F) 3000 psi
Temperature Pressure
Rating
CLEANING & PACKAGING
Every H-300U series needle valve is cleaned in accordance with Standard Cleaning and Packaging (procedure 8184). Oxygen Clean & Lubricant Free Cleaning and packaging, in accordance with Special Cleaning and Packaging (procedure 8185), is available as an option.
Lubricant free cleaned valves have
signicantly higher actuation torque.
H-300U SERIES ORDERING INFORMATION
- - - - - -
H-3
00 U
SS L V 1/4 RS
TESTING
The H-300U Series Needle Valve design has been tested for Proof and Burst. Every H-300U Needle Valve is factory tested with nitrogen at 1000 psi (69 bar). The maximum allowable leakage across the seat is 0.1 std cc/min.
PACKING ADJUSTMENT
Due to the varied service applications of the valve, packing adjustment may occasionally be necessary. Packing is factory adjusted to 1000 psig service. Initial packing adjustment is recommended after installation and prior to start-up. See packing adjustment procedure No.3901882 on the website.
OPTIONAL
Valve Series
Valve Type
00 - LET-LOK® End 10 - Female End 15 -
Female to Male End
80 - Male End 85 - Male to Female End
Male to LET-LOK
95 -
Body
Material
- 316SS
SS B
- Brass
®
End Connection
- LET-LOK
L
- NPT
N
- ISO Tapered
R
-
NPT to LET-LOK
NL
- Single Ferrule
HL
- ISO Parallel
G
- Face Seal Ends
GL
Spare Round-Handle Kits are available for each valve.
SPARE KITS
Series End Size Seal Kit* Handle Kit**
H-380U
Male to Male
H-310U
Female to Female
H-395U
Male to LET-LOK
®
H-385U
Male to Female
H-300U
LET-LOK
*Seal Kit contains packing and packing instructions **Handle Kit contains handle and set screw.
®
1/8, 1/4, 3MM, 6MM, 8MM Z-300U-SK-1/4-P Z-300U-HK-1/4-
1/8, 1/4 Z-300U-SK-1/4-P Z-300U-HK-1/4-
3/8 Z-300U-SK-1/2-P Z-300U-HK-1/2-
1/2, 3/4 Z-300U-SK-3/4-P Z-300U-HK-3/4-
1/8 Z-300U-SK-1/4-P Z-300U-HK-1/4­1/4 Z-300U-SK-1/2-P Z-300U-HK-1/2-
3/8, 1/2 Z-300U-SK-3/4-P Z-300U-HK-3/4- 1/8, 1/4 Z-300U-SK-1/4-P Z-300U-HK-1/4-
3/8 Z-300U-SK-1/2-P Z-300U-HK-1/2­1/4 Z-300U-SK-1/2-P Z-300U-HK-1/2­3/8 Z-300U-SK-1/2-P Z-300U-HK-1/2­1/2 Z-300U-SK-3/4-P Z-300U-HK-3/4-
3/8, 1/2, 10MM, 12MM Z-300U-SK-1/2-P Z-300U-HK-1/2-
3/4 Z-300U-SK-3/4-P Z-300U-HK-3/4-
®
Stem
Designator
V R K
®
NR
- V Stem
- Regulating Stem
-
Soft Seat PCTFE
- Non-Rotating Stem
Stem
End Connection Size
1/8 3MM 1/4 6MM 3/8 8 MM 1/2 10MM 3/4 12MM
Handle Type
-Black Plastic
RS
-Black Aluminum
RAS
-Red Aluminum
RAR
-Blue Aluminum
RAB
-Green Aluminum
RAG
-Yellow Aluminum
RAY
-
Metal Bar SS316
M
Treatment
BLANK - Standard Cleaning &
OC - Oxygen Clean LF - Lubricant Free
Passivation
Handle type per "How to Order"
Pattern
Designat
-
Blank
- Angle
A
or
Straight
VALVES & ACTUATORS
Warning!
The system designer and user have the sole responsibility for selecting products suitable for their special
application requirements, ensuring their safe and trouble-free installation, operation, and maintenance. Application details, material compatibility and product ratings should all be considered for each selected product. Improper selection, installation or use of products can cause property damage or personal injury.
H-300U, Rev.03, January 2015
HAM-LET ADVANCED CONTROL TECHNOLOGY
239
Loading...