Hamilton Beach 5910, 05518C, 5520, 5519, 5920 User Manual

...
Humidifier
840115700
Humidifier Safety............................ 2
Know Your Humidifier.................... 4
How to Assemble and Use............ 5
How to Clean................................ 11
Troubleshooting Guide ................ 14
In USA: 1-800-851-8900
In Canada: 1-800-267-2826
840115700 Ev00.qxd 6/6/03 8:58 AM Page 1
2
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS!
Humidifier Safety
1. Read all instructions before using this humidifier. Save these instructions for reference.
2. Always place the humidifier on a firm, flat, level, water-resistant surface.
3. To reduce the risk of electrical shock, never plug humidifier into an outlet while your hands are wet.
4. Never drop or insert any objects into any openings.
5. Never place the humidifier in a location where it is accessible to children.
6. Do not place the humidifier on or near heat sources such as stoves, radiators, heaters, or in direct sunlight.
7. Never connect the humidifier to any power source other than 120 V AC.
8. Always unplug the humidifier before refilling, cleaning, servicing, or moving.
9. Before each use, check the cord and plug for damage. Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions or is dropped or damaged in any manner. Call our toll-free customer service number for information on examination, repair or electrical or mechanical adjustment.
10. Always unplug and empty humidifier and tank when it is not in use.
11. Never tilt or attempt to move the humidifier or supporting surface while it is operating or full of water. Turn off and unplug the humidifier before removing the water tank and moving the unit.
12. This humidifier requires regular cleaning and maintenance. Refer to the instructions in the “How to Clean” section. Never clean the humidifier in a manner other than described in this manual.
13. Do not immerse fan enclosure in water or other liquids, or allow it to get wet.
14. Never use detergents, household cleaners, or other solvents to clean the humidifier, other than those specified in the Cleaning Instructions provided in this manual.
15. Do not direct output from unit at walls, furniture, or the like.
16. Do not use filters or other replacement parts not recommended or sold by Hamilton Beach/Proctor-Silex, Inc.
17. To disconnect cord, turn the control to OFF, then remove plug from wall outlet.
18. Do not use appliance for other than its intended purpose.
19. Never stand or sit on any part of the humidifier, and never place objects on the humidifier.
READ AND SAVE THESE INSTRUCTIONS.
When using electric appliances, basic safety precautions should always be followed, including the following:
840115700 Ev00.qxd 6/6/03 8:58 AM Page 2
3
Consumer Safety Information
This appliance is intended for household use only.
This appliance is equipped with a polarized plug. This type of plug has one blade wider than the other. The plug will fit into an electrical outlet only one way. This is a safety feature intended to help reduce the risk of electrical shock.
If you are unable to insert the plug into the outlet, try reversing the plug. If the plug should still fail to fit, contact a qualified electrician to replace the obsolete outlet. Do not attempt to defeat the safety purpose of the polarized plug by modifying the plug in any way.
If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier. Care must be taken to arrange the extension cord so that it will not drape over the coun­tertop or tabletop where it can be pulled on by children or accidentally tripped over.
Do Not Over-humidify
Do not over-humidify. The suggested level for the best health benefit is 50%. Some units can be set for desired humidity ranges from 20 to 90%, but care should be taken not to over­humidify, which will be dependent on both the construction of your home and the outside weather conditions.
Do not allow water to condense on walls, floors, or windows as water damage could result. If you see these conditions occur, lower the desired humidity level on the humidifier or turn the unit off. Hamilton Beach/Proctor­Silex, Inc. will not be responsible for damage caused by water.
Before First Use
Be sure to remove all packing materials. Choose a flat, level, water-resistant location for the humidifier that will allow for good air circulation and that is not accessible to children.
Do not place the humidifier where it or its cord presents a tripping or stumbling hazard, or where the air vents are blocked.
840115700 Ev00.qxd 6/6/03 8:58 AM Page 3
4
Know Your Humidifier
Parts and Features
Fan Enclosure
1. Control Panel
2. Exhaust Grille
3. Cord Wrap (see page 6)
4. Air Intake Grilles
Water Tank Assembly
5. Carrying Handle
6. Water Tank
7. Gasket
8. Filler Cap
Base Assembly
9. Filter
10. Water Tray
11. Humidifier Base
840115700 Ev00.qxd 6/6/03 8:58 AM Page 4
DO NOT:
• Do not stand, sit, or place any objects on the humidifier. It is not designed to support additional weight.
• Do not block the air intake and
exhaust grilles. This will cause poor performance and may cause moisture damage and mildew build-up.
• Do not use in a small, enclosed
space or in an area with a humidity level above 50%. Excessive humidity could result.
• Do not place on or near heat sources
such as stoves, radiators, or heaters, or in direct sunlight.
• Never place the humidifier in a
closed room. A closed room may result in excessive humidity.
• To reduce electrical noise and
interference, do not place on or near, or plug into the same outlet as, TVs, baby monitors, or cordless phones.
5
How to Assemble and Use
IMPORTANT: Your Hamilton Beach humidifier is designed for easy use and maintenance. Make sure that the water tray and filter are properly installed before filling the tank and operating the humidifier.
DO NOT USE THE HUMIDIFIER WITHOUT THE FILTER IN PLACE!
Selecting the Proper Location
To prevent the risk of injury or damage to the humidifier and furnishings and provide the best possible performance of your humidifier, follow the placement guidelines below:
DO:
• Place the humidifier on a flat, stable, waterproof surface.
• Place the humidifier along an inside
wall near an electrical outlet where it is out of the way and it and its cord do not present
a tripping hazard.
• Select a location with adequate
air circulation.
• Leave at least six inches (15 cm)
between the humidifier and any walls or furnishings. Failure to do so could cause poor air circulation and mildew or moisture damage to walls or furniture.
• Unplug the humidifier and empty the
water tank and tray if the humidifier is to be moved, or will not be used for several days.
840115700 Ev00.qxd 6/6/03 8:58 AM Page 5
6
1. Insert the water tray into the humidifier
base. Be sure that it is securely seated in the indent in the base.
4. Set the fan enclosure onto the humidifier base. Make sure that the filter lines up with the fan cover.
2. Place the filter on the water tray as shown.
3. Slide the cord through the notch at the bottom of the cord wrap com­partment. Excess cord can be stored in the cord wrap compartment.
Humidifier Assembly
840115700 Ev00.qxd 6/6/03 8:58 AM Page 6
1. Remove the filler cap on the bottom of the tank by turning it counter­clockwise until the UNLOCK arrows line up with the ridges on the tank.
2. Fill the tank with COOL tap water. DO NOT USE HOT WATER. Be sure to keep the tank free of debris.
NOTE: Using distilled or deionized water will prolong the life of the filter.
3. Replace the filler cap and turn clockwise until the LOCK arrows line up with the ridges on the tank opening. Return the tank to an upright
position. When carrying the tank, use the carry handle and support the tank from the other side.
NOTE: Always make sure the filler cap is locked and the gasket is in place before inverting water tank.
7
Filling the Water Tank
Unlocked Position
Locked Position
Filter Tip!
To prolong the life of the filter, it is recommended that you turn over the filter each time you fill the water tank.
840115700 Ev00.qxd 6/6/03 8:58 AM Page 7
8
Placing the Water Tank on the Base
Lower the tank into place until it is
properly seated, using the fan enclosure and the base to align the tank.
IMPORTANT! Never pour water into or allow water to splash into air intake or exhaust grilles.
NOTE: Some water will flow out of the tank and into the water tray when the tank is in position.
CAUTION: Once the humidifier has been filled, do not attempt to tilt or move it. If it is necessary to move the humidifier, make sure it is unplugged and remove the water tank first.
Plugging in the Humidifier
WARNING: To reduce the risk of electrical shock, never plug in the humidifier while your hands are wet!
Once the humidifier has been assembled and placed in its final location, and the tank has been filled, plug the humidifier into a wall outlet.
NOTE: The polarized plug will only fit in one direction—DO NOT try to force the plug! If you are unable to insert the plug into the outlet, try reversing the plug. If the plug still does not fit, contact a qualified electrician to replace the obsolete outlet.
840115700 Ev00.qxd 6/6/03 8:58 AM Page 8
9
Setting the Controls –
2-Speed Humidifier
1. Fan Speed Knob
2. Power On Indicator – lights
when unit is on.
1. Fan Speed Knob
2. Power On Indicator – lights
when unit is on.
3. Desired Humidity Indicator –
lights when desired humidity is reached.
4. Desired Humidity Setting Knob
Setting the Controls –
2-Speed Humidifier with Humidistat
Setting the fan speed
Turn the fan speed knob to the desired setting. To increase the humidity in a room more quickly, set the knob to HI. For quiet, nighttime operation or for a more gradual increase, set the knob to Quietmist™.
Indicator lights
The power on indicator will light to indicate that the humidifier is on.
Setting the fan speed
Turn the fan speed knob to the desired setting. To increase the humidity in a room more quickly, set the knob to HI. For quiet, nighttime operation or for a more gradual increase, set the knob to Quietmist™.
Setting the humidistat
The desired humidity knob allows you to set the humidifier to cycle on and off to maintain a selected humidity level. Turn the knob clockwise for higher humidity, counterclockwise for less. Once the desired humidity level is reached, the desired humidity indicator will light and the fan will turn off (unit is in stand-by mode).
Indicator lights
The power on indicator will light to indicate that the humidifier is on.
Quietmist
For quiet, nighttime operation or for a more gradual increase in the humidity level, set the knob to Quietmist.™
840115700 Ev00.qxd 6/6/03 8:58 AM Page 9
10
Setting the fan speed
Turn the fan speed knob to the desired setting. To increase the humidity in a room more quickly, set the knob to HI. For normal operation, set the knob to MED. For quiet, nighttime operation or for a more gradual increase, set the knob to Quietmist™.
Setting the electronic humidistat
The electronic humidistat allows you to set the humidity within a range from 20% to 90%, in 5% increments. The current room humidity level is displayed in large numbers, while the desired humidity level is displayed in smaller numbers. If the current room humidity level drops below 20%, the display will show LO. If it is higher than 90%, HI will be displayed. Press the ▲ and ▼ buttons to adjust the humidity level. The humidifier will then turn on automatically whenever the current room humidity drops more than 2% below the desired humidity. Once the desired humidity is reached, the fan will turn off and the unit will go into stand-by mode.
Indicator lights
The power on indicator will light to indicate that the humidifier is on.
1. Fan Speed Knob
2. Humidity Setting Buttons (/)
3. Power On Indicator – lights when
unit is on
Digital Display
4. Current Room Humidity Percentage
5. Desired Humidity Percentage
Setting the Controls –
3-Speed Humidifier with Electronic Humidistat
Quietmist
For quiet, nighttime operation or for a more gradual increase in the humidity level, set the knob to Quietmist.™
840115700 Ev00.qxd 6/6/03 8:59 AM Page 10