HAMEG HMS3000, HMS3010 User Guide

3GHz Spectrum Analyzer
HMS3000/ HMS3010
1stQuarter
2009
HMS3010
Amplitude measurement range -114dBm…+20dBm
Sweep time 20ms...1000s
Resolution bandwidth 100Hz…1MHz in 1-3 Steps, 200kHz (-3dB)
additional 200Hz, 9kHz, 120kHz, 1MHz (-6dB)
Spectral purity ‹ -100dBc/Hz (@100kHz)
Video bandwidth 10Hz...1MHz in 1-3 steps
Tracking Generator (HMS3010) -20dBm…0dBm in 1dB steps
Integrated AM and FM demodulator (headset output)
Detectors: Auto-, min-, max-peak, sample, RMS, quasi-peak
8 Marker with delta marker, miscellaneous peak functions
Silent operation (no fan)
6.5” TFT color VGA display, DVI output
3 x USB for mass-storage, printer and remote control
optional IEEE-488 (GPIB) or Ethernet/USB Interface
VSWR Test Unit HZ547
3GHz EMI Near Field Probe Set HZ550L
3GHZ Spectrum Analyzer HMS3000 without TG
1GHz Spectrum Analyzer HMS1000, HMS1010 (with TG) 3GHz Spectrum Analyzer HMS3000, HMS3010 (with TG)
All data valid at 23 °C after 30 minute warm-up
Frequency
Frequency range:
HMS1000, HMS1010 100kHz...1GHz
HMS3000, HMS3010 100kHz…3GHz Temperature stability: ± 2ppm (0...30°C) Aging: ± 1ppm/year Frequency counter:
Resolution 1Hz
Accuracy ± (Frequency x failure of reference) Span setting range:
HMS1000, HMS1010 0Hz (zero span) and 1kHz…1GHz
HMS3000, HMS3010 0Hz (zero span) and 100Hz…3GHz Spectral purity, SSB phase noise:
30kHz from carrier
(500MHz, +20°C...30°C) ‹-85dBc/Hz
100kHz from carrier
(500MHz, +20°C...30°C) ‹-100dBc/Hz
1MHz from carrier
(500MHz, +20°C...30°C) ‹-120dBc/Hz
Sweep time:
Span = 0Hz 20ms...100s
Span › 0Hz 20ms...1000s, min. 20ms/600MHz Resolution bandwidths (-3 dB):
HMS1000, HMS1010 1kHz...1MHz in 1–3 steps, 200kHz
HMS3000, HMS3010 100Hz...1MHz in 1–3 steps, 200kHz
Tolerance:
300 kHz ± 5% typ. 1MHz ± 10% typ.
Resolution bandwidths (-6 dB):
HMS1000, HMS1010 9kHz, 120kHz,1MHz
HMS3000, HMS3010 200Hz, 9kHz, 120kHz, 1MHz Video bandwidths: 10Hz...1MHz in 1–3 steps
Amplitude
Display range: Average noise trace up to +20dBm Amplitude measurement range: Typ. -114dBm...+20dBm Max. permissible DC at HF input: 80V Max. power at HF input: 20dBm, 30dBm für max. 3 Min. Intermodulation free range:
IM3 products, 2 x –20dBm
(-10dBm ref. level) 66dB typ. (typ. +13dBm third-order intercept)
(at distance between
signals 2MHz) 60dB typ. (+10dBm TOI)
(at distance between
signals › 2MHz) 66dB typ. (typ. +13dBm TOI) DANL (Displayed average noise level):
(RBW 1kHz, VBW 10Hz,
ref. level –30dBm
10MHz...1GHz resp. 3GHz) -105dBm, typ. -114dBm
With Preamp. -135dBm typ. (100Hz RBW)
Inherent spurious:
(ref. level≤ -20dBm,
f ‹ 30MHz, RBW100kHz) ‹ -80dBm
Input related spurious:
(Mixer level ≤ -40dBm,
carrier offset ›1MHz) -70dBc typ., -55dBc (2…3GHz)
2nd harmonic receive frequency
(mixer level -40dBm): -60dBc typ.
Level display:
Reference level -80dBm...+20dBm in 1dB steps
Display range 80dB, 40dB, 20dB, 10dB, linear
Logarithmic display scaling dBm, dBμV, dBmV
Linear display scaling μV, mV, V, nW, μW, mW, W Measured curves: 1 curve and 1 memory curve Trace Mathematics: A-B (curve-stored curve), B-A Detectors: Auto-, Min-, Max-Peak, Sample, RMS,
Average, Quasi-Peak
Failure of level display: ‹ 1,5dB, typ. 0,5dB
(ref. level to ref. level-50dB, 20°C…30°C)
Marker / Deltamarker
Number of marker: 8 Marker functions: Peak, next peak, minimum, center = marker
frequency, reference level = marker level, all marker on peak
Marker displays: Normal (level), noise marker,
(frequency) counter
Inputs / Outputs
HF Input N socket
Input Impedance: 50Ω VSWR (10MHz…1GHz/ 3GHz): ‹ 1,5 typ.
Output tracking generator:
(HMS1010/HMS3010) N socket Output Impedance: 50Ω Frequency range: 5MHz…1GHz / 3GHz
Output level: -20dBm...0dBm in 1dB steps Trigger and external reference input: BNC socket, switchable
Trigger voltage TTL
Reference frequency 10MHz
Essential level (50Ω) 10dBm Supply output for field probes: 6VDC, max. 100mA (2,5mm DIN jack) Audio output (Phone): 3,5mm DIN jack
Demodulation AM and FM
Miscellaneous
Display: 6,5" TFT Color VGA Display
Save / Recall memory: 10 complete device settings
Trigger: Free run, Video Trigger, external Trigger Interfaces: Dual-Interface USB/RS-232 (HO720),
USB-Stick (frontside), USB-Printer (rear side) from SW 2.0, DVI for ext. monitor
Power supply: 105/253 V, 50/60 Hz, CAT II Power consumption: Max. 40Watt at 230V, 50 Hz Protection class: Safety class I (EN61010-1) Operating temperature: +5°C...+40°C Storage temperature: -20°C...+70°C Max. rel. humidity: 5%...80% (non condensing) Dimensions (W x H x D): 285 x175x 220 mm Weight: 3.6 kg
Accessories supplied:
Line cord, Operating manual, Dual-Interface USB/RS-232 (HO720), CD, HZ21 Adapter plug (N plug to BNC socket)
Optional accessories:
HO3011 Preamplifier -135dBm DANL (100Hz RBW) HO730 Dual-Interface Ethernet/USB HO740 Interface IEEE-488 (GPIB), galvanically isolated HZ547 3GHz VSWR Test Unit for HMS1010, HMS3010 HZ520 Plug-in Antenna with BNC connection HZ530 Near-Field Probe Set 1GHz for EMV diagnostics HZ540 Near-Field Probe Set 3GHz for EMV diagnostics HZ560 Transient limiter HZ575 75/50Ω Converter HZ46 4RU 19'' Rackmount Kit
HM3000/3010E/061108/ce · Subject to alterations · © HAMEG Instruments GmbH®· DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49(0) 6182 800100 · www.hameg.com · info@hameg.com
www.hameg.com
Loading...