Halsey Taylor SW14A-Q User Manual

These water coolers are certified to
NSF/ANSI 61.
GGEENNEERRAALL Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CCAABBIINNEETT Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available.
CCOOOOLLEERR TTOOPP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BBUUBBBBLLEERR Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PPUUSSHHBBUUTTTTOONN AACCTTUUAATTIIOONN MMEECCHHAANNIISSMM Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AAUUTTOOMMAATTIICC SSTTRREEAAMM HHEEIIGGHHTT RREEGGUULLAATTOORR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
IINNLLEETT SSTTRRAAIINNEERR Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TTEEMMPPEERRAATTUURREE
CCOONNTTRROOLL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
SSTTOORRAAGGEE TTAANNKK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
RREEFFRRIIGGEERRAATTIIOONN SSYYSSTTEEMM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and self-lubricated fan cools copper/aluminum condenser. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VVEENNTTIILLAATTIIOONN Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SSUUGGGGEESSTTEEDD SSPPEECCIIFFIICCAATTIIOONNSS Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound­building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
SSttaannddaarrdd nniisshh iiss PPllaattiinnuumm VViinnyyll
OOppttiioonnaall FFiinniisshheess ((nnoo eexxttrraa ccoosstt))
Slate
Almond
OOppttiioonnaall FFiinniisshheess ((eexxttrraa ccoosstt))
All Stainless Steel
OOppttiioonnaall AAcccceessssoorriiee ss ((eexxttrraa ccoosstt))
Glass Filler
Vandal-Resistant Kit
Water Filter
Easy-Flex™Bubbler
Trap and service stop not included.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
C5 / 8-2007
MMOODDEELL:: SSWW44AA--QQ SSWW88AA--QQ
SSWW1144AA--QQ SSWW--LL//RR ((LLeessss RReeffrriiggeerraattiioonn))
Wall-Mounted Cooler
Compact
halseytaylor.com
SSWW SSEERRIIEESS
MMooddee ll GGPPHH CCaappaacciittyy BBaassee FF..LL.. SS hhiippppiinngg RRaatteedd NNoo.. CCoooolleedd ttoo 5500°° FF** RRaattee AA mm pp ss WWeeii gghhtt WWaatttt
AAmmbbii eenntt AAiirr TTeemmpp
CCaapp.. llbb.. UUssaaggee
7700°°FF 8800°°FF 9900°°FF
110000°°FF
SSWW44AA--QQ
4.8 4.4 4.0 3.6 4.0 2.5 60 230
SSWW88AA--QQ
9.2 8.4 7.6 6.8 7.6 4.0 68 370
SSWW1144AA--QQ
16.8 15.4 13.5 12.6 13.5 7.5 70 690
**
With projector service and tap water at 80° F
UL listed and complies with ARI Standard 1010
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
Printed in the U.S.A.
SSWW44AA--QQ,, SSWW88AA--QQ,, SSWW1144AA--QQ,, SSWW--LL//RR
CCoommppaacctt WWaallll--MMoouunntteedd CCoooolleerr
(CONTINUED)
MMOOUUNNTTIINNGG HHEEIIGGHHTT Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height.
MMOOUUNNTTIINNGG IINNSSTTRRUUCCTTIIOONNSS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6
1
/4" from wall face.
Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22
1
/2"
from floor line for conventional adult installation.
PPLLUUMMBBIINNGG CCOONNNNEECCTTIIOONNSS Enter directly into cabinet. Waste 1
1
/4" O.D. slip
connection. Supply
3
/8" tubing.
Trap and service stop not included.
OOPPEERRAATTIINNGG PPRREESSSSUURREESS:: Supply water-105 psi maximum
EELLEECCTTRRIICCAALL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
SSIIDDEE VVIIEEWWFFRROONNTT VVIIEEWW // WWAALL LL LLAAYYOOUUTT
NOTE: Optional holes may be added to back panel to secure bottom of cooler to wall. Minimum wall clearance for air flow is 4 inches (102mm) on either side.
NOTE: A service supply stop must be installed at the cooler inlet line.
*Alternate location for waste outlet provides improved access but requires tailpiece to be shortened.
1-1/4" Drain trap not included.
Loading...