Halsey Taylor SJ8 Installation Manual

LAG BOLTS OR SCREWS (10 REQ’D) (NOT PROVIDED)
HOOK RODS (2) P/N 101567443730
WOOD SCREWS (NOT PROVIDED)
SJ8 MOUNTING FRAME INSTRUCTIONS
WOOD FOR STEEL FRAME (NOT PROVIDED)
CHILLER SHELF P/N 401567343730
ELECTRICAL INLET LOCATION ON CHILLER
FLOOR LINE
1. Cut a rectangular wall opening 18 3/4" (476mm) W x 23 3/8" (594mm) H and 4 1/2" (min.) (1 14mm) above the floor line.
NOTE: Building construction must allow for adequate air flow on both sides and top of remote chiller unit. Minimum of 4" (102mm) is required.
2. Install plumbing and electrical rough-ins. A junction box for a (3) wire, 10 amp branch circuit is provided on the inside of the chiller. (S t andard 120 V olts, 60 Hz and single phase)
NOTE: Be sure that frame is squared in location. Do not use less than the required screw quantity .