SJ32W-1D
HALSEY T A YLOR OWNERS MANUAL
SJ32W
Refrigeration Package
INSTALLATION
1. This unit is intended for remote installation only. It is important to insure proper ventilation. A minimum of 6 inches
(152mm) to the front must be maintained, and 6 inches (152mm) to the rear of the unit.
2. This chiller has been designed for use with potable water and includes an o-ring seal on the drain plug. This
fitting should be replaced if the unit is to be used with more aggressive fluids.
3. Installer to provide air gap at condenser water outlet to comply with local plumbing specifications.
4. Connecting lines to be made of copper. Thoroughly flush all lines to remove all foreign matter before connecting to
cooler. If flushing does not remove all particles, a water strainer should be installed in the supply line.
5. Connect cooler to building supply with a shut-off valve and install a union connection between the valve and the
cooler.
6. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate.
NOTICE: This water cooler must be connected to the water supply using a dielectric coupling.
Never wire the compressor directly to the power supply.
LEGEND
A = 3/8" O.D. TUBE W A TER INLET
B = 3/8" O.D. TUBE WA TER OUT
C = TEMPERATURE ADJUSTMENT
D = ELECTRICAL
E = 3/8" O.D. TUBE T ANK DRAIN
F = 3/8" O.D. TUBE CONDENSER WA TER OUTLET
G = 3/8" O.D. TUBE CONDENSER WA TER INLET
H = FREEZE CONTROL
98471C (Rev. A - 9/08)
PARTS LIST
ITEM NO.
10
11
*12
13
14
15
16
18
19
20
21
22
23
24
25
26
27
28
29
30
*INCLUDES COMPRESSOR, CSIR BOX ASSY & OVERLOAD. IF UNDER
WARRANTY REPLACE WITH SAME COMPRESSOR USED IN
ORIGINAL ASSEMBL Y .
NOTE: ALL CORRESPONDENCE PERTAINING TO AN Y OF THE ABOVE
WATER COOLERS OR ORDERS FOR REP AIR P ARTS MUST INCLUDE
MODEL NO. AND SERIAL NO. OF COOLER, NAME AND P ART NO. OF
REPLACEMENT PAR T .
NOTE: FOR USE WITH PHOTO PROCESSING APPLICA TIONS,
ADJUST THERMOSTA T T O WARMER SETTINGS.
PART NO.
1
2
3
4
5
6
7
8
9
28165C
28218C
28166C
28032C
23158C
26701C
34783005
35882C
66633C
36252C
30768C
36251C
35984C
35989C
35988C
35990C
50196C
66624C
70772C
66621C
70020C
30039C
66623C
30040C
36045C
70482C
70274C
70483C
35895C
BOX - INSULATION
BASE ASSY
PANEL
PANEL - FRONT/REAR
COVER - INSULATION BOX
CABINET
WASHER - LOCK
CONTROL - COLD
CONDENSER ASSY
CSIR BOX ASSY
SOLENOID VAL VE
COMPRESSOR SERVICE PAK
OVERLOAD
GASKET - TERM COVER
OVERLOAD SPRING
BALE STRAP
GROMMET - COMPRESSOR MTG
EVAPORATOR ASSY
EVAPORATOR DRAIN PLUG
DRIER
NUT
ELECTRICAL BOX
HEAT EXCHANGER
ELECTRICAL BOX COVER
OVERLOAD COVER
MALE CONNECTOR FITTING
SLEEVE-COMPRESSOR
ELBOW FITTING
FREEZE CONTROL
DESCRIPTION
SJ32W-1D
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which
cooler is connected. A steady stream flow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
IMPORTANT! INSTALLER PLEASE NOTE:
The grounding of electrical equipment such as telephone, computers, etc., to water
lines is a common procedure. This grounding may be in the building, or may occur
away from the building. This grounding can cause electrical feedback into a water
chiller, creating an electrolysis which causes a metallic taste or an increase in the
metal content of the water. This condition is avoidable by using the proper materials
indicated below. Drain fittings which are provided by the installer should be plastic to
electrically isolate the chiller from the building plumbing system.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set for 50°F water under normal conditions. To
adjust water temperature, turn screw on Item No. 8 clockwise for colder, counter
clockwise for warmer.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with
a brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no
cold water and compressor cycling on the overload protector.
Lubrication: Motors are lifetime lubricated.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free plug
which utilizes an o-ring seal. To remove plug from cooler, relieve water pressure,
pull the collar towards the fitting and pull the fitting off the tube. To install plug,
push fitting straight onto tubing until it reaches a positive stop, approximately 3/4”.
7, 22, 19
13, 14,15, 16, 26
3
10
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
24
20
30
23, 25
5
1
2
8
18, 28
12
21
11
27, 29
4
6
9
PRINTED IN U.S.A.
98471C (Rev. A - 9/08)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620